M2XH, M2XCH & M2XSH 0.6/1 kV Halogen-Free Shipboard Power Cable (IEC 60092-353)
M2XH, M2XCH and M2XSH form the European DIN/IEC 60092-353 0.6/1 kV halogen-free shipboard power cable triad: M2XH (unscreened), M2XCH (90% copper-wire braided EMC screen) and M2XSH (90% galvanized steel-wire braided mechanical armour), supplied in both FI (extruded halogen-free inner bedding) and NOFI (taped) builds with Class 2 or Class 5 stranded copper conductors, XLPE 90 °C insulation and black SHF1 flame-retardant outer sheath for -40 °C to +90 °C fixed marine installations.
M2XH, M2XCH and M2XSH (in both FI and NOFI variants) constitute a 0.6/1 kV (1.2 kV Um) halogen-free, flame-retardant shipboard power and control cable family engineered to IEC 60092-353 and IEC 60092-350/360 for commercial vessels, passenger ferries, tugs, dredgers and offshore support ships.
Modern shipyards specify the M2X designation family to match each compartment's electromagnetic and mechanical risk without changing insulation chemistry. Every variant pairs stranded electrolytic copper (IEC 60228 Class 2 standard, Class 5 flexible or tinned copper on request) with 90 °C cross-linked polyethylene (XLPE) insulation and a UV-stabilized black SHF1 thermoplastic halogen-free outer sheath rated from -40 °C to +90 °C. M2XH delivers the lightest unscreened routing for accommodation and dry lighting trunks; M2XCH adds a 90% minimum bare copper wire braid screen to suppress electromagnetic interference near bridge electronics and frequency drives; and M2XSH substitutes a 90% minimum galvanized steel wire braid for exposed open-deck mechanical crush and impact protection.
Choose M2XH, M2XCH or M2XSH for standard halogen-free shipboard power distribution; step up to M2XH-FFR / M2XCH-FFR where IEC 60331 circuit integrity during fire is mandatory, M2XCH-VFD for symmetrical 3+3 propulsion drives, or NEK 606 RFOU/BFOU where drilling-mud resistance (SHF2) is required. Minimum order 50 m per size; standard lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
M2XH, M2XCH & M2XSH XLPE / SHF1 Shipboard Construction
Concentric halogen-free shipboard build combining IEC 60228 Class 2 or Class 5 copper, 90 °C XLPE insulation, FI/NOFI bedding, optional 90% copper or steel braid and black SHF1 sheath.

| Component | Material and construction |
|---|---|
| 1. Stranded Electrolytic Copper Conductor | Annealed plain copper per IEC 60228 Class 2 (flexible Class 5 and/or tinned copper on request) from 1.0 mm² to 300 mm² for single-core and multi-core layouts. |
| 2. 90 °C Cross-Linked Polyethylene (XLPE) Insulation | Halogen-free thermoset XLPE rated 0.6/1 kV (1.2 kV Um) with 250 °C short-circuit capability and IEC 60092-353 core color or number identification. |
| 3. Halogen-Free Inner Bedding (FI) or Separator Tape (NOFI) | Extruded non-hygroscopic halogen-free bedding (FI) for circular cable-gland compression, or compact polyester binder tape (NOFI) for reduced tray diameter. |
| 4. Optional 90% Copper Braid (M2XCH) or Galvanized Steel Braid (M2XSH) | M2XCH incorporates a minimum 90% bare copper wire braid for EMC shielding; M2XSH incorporates a minimum 90% galvanized steel wire braid for deck mechanical armouring. |
| 5. Black SHF1 Halogen-Free Flame-Retardant Outer Sheath | Low-smoke zero-halogen thermoplastic polyolefin compound (SHF1 to IEC 60092-360), oil- and UV-resistant (ISO 4892-2/-3), rated -40 °C to +90 °C. |
M2XH, M2XCH & M2XSH Designation & FI/NOFI Code Breakdown
- M: Marine shipboard cable design conforming to European DIN / IEC 60092-353 nomenclature
- 2X: 90 °C cross-linked polyethylene (XLPE) thermoset core insulation
- C / S / (blank): C = 90% bare copper wire braid EMC screen; S = 90% galvanized steel wire braid armour; blank = unscreened
- H: Halogen-free, low-smoke, flame-retardant thermoplastic SHF1 outer sheath
- FI / NOFI: FI = extruded halogen-free inner bedding; NOFI = tape-wrapped compact bedding; Class 2 or Class 5 conductor
M2XH, M2XCH & M2XSH Engine-Room, Deck & Switchboard Applications
Engineered for fixed power, lighting, auxiliary machinery and control circuits across below-deck and open-deck shipboard zones.

- Main and auxiliary 0.6/1 kV shipboard power feeders in engine rooms, pump rooms, cargo holds and accommodation blocks.
- EMC-sensitive bridge, steering-gear, winch control and automation circuits requiring M2XCH 90% copper wire braid shielding.
- Exposed weather-deck, thruster compartment and cargo-handling pathways requiring M2XSH galvanized steel wire braid mechanical protection.
- Shipyard refits and new-build European/international vessels standardizing on Class 5 flexible FI halogen-free cable trays.
M2XH / M2XCH / M2XSH vs M2XCH-FFR vs NEK 606 RFOU
| Cable Family | Insulation & Sheath | Protection Tier | Primary Marine Selection |
|---|---|---|---|
| M2XH / M2XCH / M2XSH (this page) | XLPE / SHF1 LSZH | Unscreened, 90% Cu braid or 90% GSWB | Standard 0.6/1 kV commercial shipboard power & control |
| M2XH-FFR / M2XCH-FFR | Mica + XLPE / SHF1 | IEC 60331 circuit integrity during fire | Emergency pumps, fire alarms, steering & muster lighting |
| M2XCH-VFD / M2XCH-EMC | XLPE / SHF1 (3+3) | Copper tape + braid dual EMC screen | Variable-frequency marine propulsion & thruster drives |
| NEK 606 RFOU / BFOU | EPR / SHF2 Mud-Res. | Tinned copper braid + drilling-mud sheath | Offshore drilling rigs, FPSO process decks & mud rooms |
Select M2XH/M2XCH/M2XSH for standard merchant vessels and SHF1 shipyards; specify NEK 606 RFOU/BFOU only where SHF2 mud resistance is mandated.
M2XH / M2XCH / M2XSH Marine Cable RFQ Checklist
- Exact designation tier: M2XH (unscreened), M2XCH (90% copper braid EMC) or M2XSH (90% galvanized steel braid armour).
- Bedding preference (FI extruded inner bedding for marine barrier glands vs NOFI compact tape wrap) and conductor class (Class 2 or flexible Class 5, bare or tinned).
- Core count and cross-section (e.g. 3×35 mm², 4×16 mm², 12×1.5 mm²) plus core identification preference (color-coded or white-numbered).
- Required length per size (MOQ 50 m), drum packaging and any requested factory routine or third-party witnessed inspection.
Related selection resources
- Upgrade to M2XH-FFR & M2XCH-FFR IEC 60331 Fire-Resistant Shipboard Power Cables
- Explore M2XCH-VFD & M2XCH-EMC Symmetrical Marine Drive Cables
- Specify MVCECH 3.6/6–12/20 kV Medium-Voltage Marine Power Cables
- Compare MGCG / MGCH DIN 89158 Rubber & LSZH Marine Cables
- Browse Complete Marine & Offshore Shipboard Cable Catalog
- Explore Shipboard & Offshore Marine Cable Solutions Hub
M2XH, M2XCH & M2XSH Shipboard Power Cable FAQ
What is the difference between M2XH, M2XCH and M2XSH shipboard power cables?
M2XH is an unscreened 0.6/1 kV XLPE/SHF1 halogen-free marine power cable, M2XCH adds a 90% bare copper wire braid screen for EMC interference suppression, and M2XSH replaces the copper braid with a 90% galvanized steel wire braid for mechanical crush protection on open decks.
What do FI and NOFI mean on M2XH and M2XCH marine cable drawings?
FI specifies an extruded halogen-free inner bedding (typically 0.8 to 2.2 mm thicker than NOFI) to keep the cable circular for watertight compression glands, while NOFI uses a polyester separator tape to minimize outer diameter and weight in dense shipboard trays.
Are M2XH, M2XCH and M2XSH cables available with Class 5 flexible conductors?
Yes. All three constructions are manufactured with either IEC 60228 Class 2 stranded copper for straight bulk runs or flexible Class 5 bare/tinned copper for tight engine-room bends and compact switchgear terminations.
When should a shipyard choose M2XCH over NEK 606 RFOU?
Choose M2XCH (0.6/1 kV SHF1 thermoplastic halogen-free sheath) for commercial ships, ferries, dredgers and naval auxiliary trays where drilling-mud immersion is absent—lowering diameter, weight and cost—and reserve NEK 606 RFOU (SHF2) for offshore rigs and mud-exposed process decks.
What is the MOQ and lead time for custom M2XH, M2XCH and M2XSH marine cables?
50 m minimum order per size, manufactured to IEC 60092-353 specifications in 7 to 45 working days with factory routine electrical and dimensional test records.
M2XH, M2XCH & M2XSH Dimension & Weight Schedule
M2XH / M2XCH / M2XSH Electrical & Thermal Ratings
- Three mechanical and EMC tiers: M2XH unscreened, M2XCH copper-wire braided (minimum 90% EMC coverage) and M2XSH galvanized steel-wire braided armour
- FI and NOFI bedding constructions: Supplied with extruded halogen-free inner covering (FI) for gas-tight gland sealing or compact tape-wrapped (NOFI) profiles
- IEC 60092-353 0.6/1 (1.2) kV rating: 3.5 kV AC routine test voltage, 90 °C continuous XLPE insulation, -40 °C to +90 °C fixed temperature range (-15 °C installation)
- Zero-halogen SHF1 safety compliance: Designed to IEC 60332-3-22 Cat. A flame propagation, IEC 60754-1/-2 acid gas and IEC 61034-1/-2 low smoke density
- 50 m MOQ and custom conductor options: 1 to 37 cores across 1.0 mm² to 300 mm² in Class 2 or flexible Class 5 bare/tinned copper, delivered in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (1.2 kV Um), 3.5 kV AC routine test voltage per IEC 60092-353 |
| Operating temperature range | -40 °C to +90 °C fixed service (-15 °C minimum recommended installation temperature; 250 °C short-circuit) |
| Minimum bending radius | 4 × D for M2XH up to 25 mm OD (6 × D above 25 mm OD); 6 × D for braided M2XCH and M2XSH |
| Conductor and insulation | IEC 60228 Class 2 or Class 5 bare/tinned copper (1.0–300 mm², 1–37 cores) with 90 °C XLPE insulation |
| Screen, armour and outer sheath | Unscreened (M2XH), 90% copper braid (M2XCH) or 90% galvanized steel braid (M2XSH) under black SHF1 halogen-free sheath |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
M2XH, M2XCH & M2XSH 0.6/1 kV Dimension & Weight Schedule
| Designation & Build | Cores × Size (mm²) | Screen / Armour | Nominal OD (mm) | Approx. Weight (kg/km) | Min. Bend Radius | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| M2XH (FI) 1×95 | 1 × 95 | Unscreened | 18.8 | 1,020 | 4 × D | 50 m | Request this size |
| M2XH (FI) 3×1.5 | 3 × 1.5 | Unscreened | 10.0 | 135 | 4 × D | 50 m | Request this size |
| M2XH (FI) 3×16 | 3 × 16 | Unscreened | 18.6 | 670 | 4 × D | 50 m | Request this size |
| M2XH (FI) 4×50 | 4 × 50 | Unscreened | 32.5 | 2,410 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 2×1.5 | 2 × 1.5 | 90% Cu Braid | 10.6 | 165 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 3×2.5 | 3 × 2.5 | 90% Cu Braid | 12.0 | 225 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 4×10 | 4 × 10 | 90% Cu Braid | 18.9 | 680 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 3×35 | 3 × 35 | 90% Cu Braid | 26.4 | 1,560 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 3×95 | 3 × 95 | 90% Cu Braid | 40.2 | 3,790 | 6 × D | 50 m | Request this size |
| M2XCH (FI) 12×1.5 | 12 × 1.5 | 90% Cu Braid | 18.2 | 495 | 6 × D | 50 m | Request this size |
| M2XSH 3×16 | 3 × 16 | 90% GSWB | 21.8 | 960 | 6 × D | 50 m | Request this size |
| M2XSH 4×25 | 4 × 25 | 90% GSWB | 27.6 | 1,650 | 6 × D | 50 m | Request this size |
| M2XSH 3×70 | 3 × 70 | 90% GSWB | 37.8 | 3,180 | 6 × D | 50 m | Request this size |
Nominal diameters and weights correspond to Class 5 flexible FI builds (NOFI taped builds run 0.8 to 2.2 mm slimmer; Class 2 solid-strand equivalents and additional 1-core to 37-core sizes up to 300 mm² are built to order). Third-party witnessed factory testing is available per purchase order.
ASCII part references for BOM and ERP entry: M2XH-FI-1x95, M2XH-FI-3x1.5, M2XH-FI-3x16, M2XH-FI-4x50, M2XCH-FI-2x1.5, M2XCH-FI-3x2.5, M2XCH-FI-4x10, M2XCH-FI-3x35, M2XCH-FI-3x95, M2XCH-FI-12x1.5, M2XSH-3x16, M2XSH-4x25, M2XSH-3x70.
M2XH / M2XCH / M2XSH IEC 60092-353 Flame & Halogen-Free Standards
| Standard or specification | Application |
|---|---|
| IEC 60092-353 & IEC 60092-350 / -360 | Design reference for 0.6/1 kV XLPE-insulated, SHF1 halogen-free sheathed shipboard power cables. |
| IEC 60332-1-2 & IEC 60332-3-22 Cat. A | Vertical single-cable and bunched-cable flame-propagation test design reference. |
| IEC 60754-1/-2 & IEC 61034-1/-2 | Zero-halogen corrosive gas emission and low smoke optical density design reference for enclosed ship compartments. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 production quality management and routine test records
IEC 60092-353 — Electrical Installations in Ships: Power Cables for Rated Voltages 1 kV and 3 kV
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331)
A related cable option for a different application or duty profile.
View productM2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Marine VFD Motor Cable
A related cable option for a different application or duty profile.
View productMVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable (IEC 60092-354)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.