M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Marine VFD Motor Cable

M2XCH-VFD (symmetrical 3 phase + 3 split earth conductors) and M2XCH-EMC (100% overlapping copper tape plus 90% bare copper wire braid dual shield) are halogen-free marine VFD motor cables in 0.6/1 kV and 1.8/3 (3.6) kV AC voltage classes. Engineered to IEC 60092-353 with low-capacitance 90 °C XLPE insulation and black SHF1 halogen-free sheathing, they suppress high-frequency PWM switching harmonics, shaft bearing currents and radiated EMI on shipboard thrusters, winches and electric propulsion drives.

Product information
SKU
TF-M2X-VFD-3KV
Brand
TEBAOFLEX
Product overview

M2XCH-VFD and M2XCH-EMC (rated 0.6/1 kV and 1.8/3 (3.6) kV AC) are double-screened, halogen-free shipboard variable-frequency drive (VFD) motor supply cables built to IEC 60092-353 and IEC 60092-350/360 for modern diesel-electric and hybrid vessels.

Conventional asymmetrical 4-core shipboard cables create unbalanced ground impedances when driven by fast-switching IGBT marine inverters—injecting high-frequency shaft voltages that pit thruster bearings and radiating broadband EMI into sensitive bridge navigation electronics. M2XCH-VFD eliminates both failure modes by splitting the protective earth into three equal conductors positioned symmetrically at 120-degree valleys around the three XLPE phase cores, wrapped beneath an overlapping copper foil/tape plus a minimum 90% bare copper wire braid. For 690 V AC drives with long inverter-to-motor cable runs, the 1.8/3 (3.6) kV insulation wall provides critical dielectric margin against reflected PWM peak surges.

Choose M2XCH-VFD or M2XCH-EMC for commercial shipboard electric propulsion, bow/stern thrusters, HVAC chillers and winch drives; step up to NEK 606 BFOU VFD 1.8/3 kV where offshore drilling-mud resistance (SHF2) and fire survival are mandatory, or MVCECH for 3.6/6 kV to 12/20 kV medium-voltage propulsion feeders. Minimum order 50 m; standard lead time 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

M2XCH-VFD & M2XCH-EMC Symmetrical Dual-Screen Construction

Symmetrical 3+3 low-capacitance XLPE power core with overlapping copper-tape plus 90% copper-braid dual EMC screen and black SHF1 halogen-free jacket.

Clean 2D technical cross-section of symmetrical 3+3 M2XCH-VFD marine EMC motor cable showing black SHF1 outer sheath, overlapping copper tape plus copper braid dual screen, three brown black grey XLPE phase cores and three small yellow-green earth cores in valleys
Symmetrical 3+3 M2XCH-VFD cross-section balancing ground impedance under dual copper-tape and copper-braid EMC shielding.
M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Marine VFD Motor Cable construction
ComponentMaterial and construction
1. Stranded Electrolytic Copper Phase & Split Earth ConductorsIEC 60228 Class 2 or flexible Class 5 annealed copper (tinned on request); 3 equal phase cores paired with 3 symmetrically placed split earth cores (3+3E).
2. Low-Capacitance 90 °C XLPE Insulation (0.6/1 kV or 1.8/3 kV)Cross-linked polyethylene dielectric minimizing charging current and withstanding fast IGBT dv/dt switching reflections.
3. Halogen-Free Extruded Inner Covering & Separator FoilCompact halogen-free bedding maintains tight symmetrical core positioning and clean concentric screen contact.
4. Dual EMC Screen: Overlapping Copper Tape + Minimum 90% Copper Braid100% overlapping bare copper tape (or Al/Cu foil) backed by a dense bare copper wire braid achieves ultra-low high-frequency transfer impedance.
5. Black SHF1 Halogen-Free Flame-Retardant Outer SheathUV- and oil-resistant SHF1 thermoplastic polyolefin jacket rated -40 °C to +90 °C (minimum -15 °C installation) per IEC 60092-360.

M2XCH-VFD & M2XCH-EMC Designation Breakdown

  • M2X: Marine shipboard cable (M) with low-capacitance 90 °C XLPE (2X) insulation
  • C: Dual EMC copper shield: 100% overlapping copper tape plus minimum 90% bare copper wire braid
  • H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath
  • -VFD / -EMC: -VFD = symmetrical 3-phase + 3-split-earth (3+3E) geometry; -EMC = improved dual-screened 1–4 core EMC build
  • 0.6/1 kV / 1.8/3 kV: Rated AC voltage class (3.5 kV test for 0.6/1 kV; 6.5 kV test for 1.8/3 kV high-dv/dt drives)
Applications

M2XCH-VFD & M2XCH-EMC Marine Propulsion & Thruster Applications

Engineered for inverter-controlled AC motors and high-EMI power electronics across marine engine rooms, thruster spaces and deck machinery.

Modern ship electric propulsion drive room with black screened M2XCH-VFD marine motor cables running neatly from inverter cabinets to azimuth thruster motors
Shipboard electric-propulsion variable-frequency drive installation wired with symmetrical dual-screened M2XCH-VFD cables.
  • Variable-frequency azimuth thrusters, bow/stern tunnel thrusters and main electric-propulsion motors on ferries, tugs and OSVs.
  • Shipboard cargo pumps, LNG/LPG booster pumps, ballast-water treatment drives and engine-room cooling-water VFD fans.
  • Deck crane, anchor windlass and offshore winch inverter cabinets routing alongside bridge radar, sonar and autopilot trays.
  • 690 V AC high-power marine inverter drives where 1.8/3 (3.6) kV insulation eliminates premature partial-discharge aging.

M2XCH-VFD vs Standard M2XCH vs BFOU VFD vs MVCECH

M2XCH-VFD (0.6/1 & 1.8/3 kV) vs Standard M2XCH vs BFOU VFD 1.8/3 kV vs MVCECH 6/10 kV
Cable FamilyCore Geometry & ScreenVoltage ClassTarget Propulsion / Drive Scope
M2XCH-VFD / EMC (this page)3+3 Sym. + Cu Tape + Braid0.6/1 kV & 1.8/3 kVShipboard 400–690 V AC VFD thrusters, pumps & winches
M2XCH Standard3C / 4C + Cu Braid only0.6/1 kVFixed-frequency marine motors & general distribution
NEK 606 BFOU VFD3+3 Sym. + Mica + SHF21.8/3 kVOffshore drilling rigs needing mud resistance & fire survival
MVCECH MV Marine3C Semicon-Screened XLPE3.6/6–12/20 kVMedium-voltage shipboard main propulsion switchboards

Upgrade from 0.6/1 kV to 1.8/3 kV M2XCH-VFD whenever 690 V marine drives exceed 30–50 m run length or operate without output dV/dt filters.

M2XCH-VFD & M2XCH-EMC Marine VFD Cable RFQ Checklist

  • Voltage class: 0.6/1 kV (400–480 V drives) or 1.8/3 (3.6) kV (690–1,000 V marine propulsion / thruster VFD drives).
  • Symmetrical 3+3E layout (M2XCH-VFD) or standard 3C/4C dual-shielded layout (M2XCH-EMC) and exact phase/earth cross-sections.
  • Conductor class (Class 2 or flexible Class 5, bare or tinned copper) and optional 360-degree EMC gland compatibility OD window.
  • Order length per size (MOQ 50 m; standard delivery 7 to 45 working days).

Related selection resources

M2XCH-VFD & M2XCH-EMC Marine VFD Cable FAQ

Why do marine VFD drives require 3+3 symmetrical M2XCH-VFD instead of standard 4-core M2XCH?

A single oversized earth core inside a 4-core cable creates geometric asymmetry that induces circulating currents and shaft voltages on variable-frequency motors. Splitting the earth into three equal conductors spaced symmetrically around the three phases balances magnetic flux and protects thruster bearings.

When should I choose 1.8/3 kV M2XCH-VFD over 0.6/1 kV for a 690 V shipboard drive?

PWM inverters on 690 V marine buses generate rapid rise-time voltage reflections reaching 1,800 to 2,200 V peak at the motor terminals. Selecting 1.8/3 (3.6) kV XLPE insulation provides higher corona inception voltage and longer insulation life without mandatory sinusoidal output filters.

What is the difference between M2XCH-VFD and M2XCH-EMC?

Both use dual copper-tape plus 90% copper-wire-braid shielding for low RF transfer impedance; M2XCH-VFD specifically pairs that dual screen with a symmetrical 3-phase plus 3-split-earth (3+3E) geometry for inverter motors, while M2XCH-EMC covers general 1- to 4-core high-EMI feeders.

Can M2XCH-VFD be supplied with tinned copper conductors and flexible Class 5 stranding?

Yes. Both bare and tinned IEC 60228 Class 2 or flexible Class 5 copper strands are available across 3×1.5+3G through 3×240+3G mm².

What is the minimum order quantity and delivery lead time for M2XCH-VFD?

50 m minimum order per size, manufactured to order in 7 to 45 working days with factory routine HV and conductor resistance test reports.

Specifications

M2XCH-VFD 0.6/1 kV & 1.8/3 kV Dimension Schedule

M2XCH-VFD Electrical, EMC & Thermal Summary

  • Symmetrical 3+3 earth geometry (M2XCH-VFD): Three split earth cores nestled in the phase interstices cancel common-mode circulating currents and protect motor bearings
  • Dual copper tape + 90% copper braid EMC shield: Low transfer-impedance 360-degree RF screen suppresses PWM carrier noise near bridge radar, GPS and automation buses
  • Dual voltage tiers: 0.6/1 kV & 1.8/3 (3.6) kV: Thickened 1.8/3 kV XLPE insulation withstands high-dv/dt inverter voltage spikes on 690 V to 1,000 V marine drives
  • -40 °C to +90 °C SHF1 halogen-free safety: IEC 60332-3-22 Cat. A flame retardant, zero-halogen (IEC 60754), low smoke (IEC 61034) and UV/oil-resistant jacket
  • 50 m MOQ across 3×1.5+3G to 3×240+3G: Class 2 or flexible Class 5 bare/tinned copper conductors custom-manufactured in 7 to 45 working days
M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Marine VFD Motor Cable technical data
ParameterValue
Rated voltage0.6/1 kV AC (3.5 kV test) and 1.8/3 (3.6) kV AC (6.5 kV test) per IEC 60092-353
EMC shielding architectureOverlapping copper tape plus minimum 90% bare copper wire braid with symmetrical 3+3 split earth layout
Operating temperature range-40 °C to +90 °C fixed service (-15 °C minimum installation; 250 °C short-circuit)
Minimum bending radius6 × D for 0.6/1 kV M2XCH-VFD / EMC; 6 × D to 8 × D for 1.8/3 kV heavy sections
Size range and conductor class3×1.5+3G to 3×240+3G mm² (M2XCH-EMC also 1–4 core) in Class 2 or Class 5 bare/tinned copper
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Dimension Schedule

M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Symmetrical Marine VFD Size Schedule
Model & Core Layout (mm²)Voltage ClassDual EMC ScreenNominal OD (mm)Approx. Weight (kg/km)Test VoltageOrder MOQNext step
M2XCH-VFD 3×4+3G0.75 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid15.23653.5 kV AC50 mRequest this size
M2XCH-VFD 3×10+3G1.5 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid19.06353.5 kV AC50 mRequest this size
M2XCH-VFD 3×25+3G4 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid25.41,2903.5 kV AC50 mRequest this size
M2XCH-VFD 3×50+3G10 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid33.22,3903.5 kV AC50 mRequest this size
M2XCH-VFD 3×95+3G16 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid43.54,2403.5 kV AC50 mRequest this size
M2XCH-VFD 3×150+3G25 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid53.26,5203.5 kV AC50 mRequest this size
M2XCH-VFD 3×16+3G2.5 (3 kV)1.8/3 kVCu Tape + 90% Cu Braid24.81,0206.5 kV AC50 mRequest this size
M2XCH-VFD 3×35+3G6 (3 kV)1.8/3 kVCu Tape + 90% Cu Braid31.21,8506.5 kV AC50 mRequest this size
M2XCH-VFD 3×70+3G16 (3 kV)1.8/3 kVCu Tape + 90% Cu Braid40.43,3806.5 kV AC50 mRequest this size
M2XCH-VFD 3×120+3G25 (3 kV)1.8/3 kVCu Tape + 90% Cu Braid49.65,4606.5 kV AC50 mRequest this size
M2XCH-VFD 3×185+3G35 (3 kV)1.8/3 kVCu Tape + 90% Cu Braid60.58,2506.5 kV AC50 mRequest this size
M2XCH-EMC 4×16 (1 kV)0.6/1 kVCu Tape + 90% Cu Braid21.89103.5 kV AC50 mRequest this size

360-degree EMC cable glands bonded directly onto the copper braid at both the inverter cabinet and motor terminal box are essential to realize full transfer-impedance shielding performance.

ASCII part references for BOM and ERP entry: M2XCH-VFD-1KV-3x4, M2XCH-VFD-1KV-3x10, M2XCH-VFD-1KV-3x25, M2XCH-VFD-1KV-3x50, M2XCH-VFD-1KV-3x95, M2XCH-VFD-1KV-3x150, M2XCH-VFD-3KV-3x16, M2XCH-VFD-3KV-3x35, M2XCH-VFD-3KV-3x70, M2XCH-VFD-3KV-3x120, M2XCH-VFD-3KV-3x185, M2XCH-EMC-1KV-4x16.

Standards

M2XCH-VFD & M2XCH-EMC IEC 60092-353 Marine Drive Standards

M2XCH-VFD & M2XCH-EMC 0.6/1 kV & 1.8/3 kV Marine VFD Motor Cable standards and test references
Standard or specificationApplication
IEC 60092-353 & IEC 60092-350 / -360Construction reference for 0.6/1 kV and 1.8/3 (3.6) kV XLPE-insulated, SHF1-sheathed marine drive cables.
IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2Shipboard bunched flame-spread, halogen-free gas toxicity and low-smoke safety reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and routine electrical QA records

IEC 60092-353 — Electrical Installations in Ships: Power Cables for 1 kV and 3 kV

IEC 60332-3-22 — Bunched Cable Vertical Flame Spread Test (Category A)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.