MGCG, FMGCG, MGG & MGCH (-FFR) DIN 89158 / 89159 / 89160 Marine Cable
MGCG, FMGCG, MGG, MGH, MGCH and FMGCH (-FFR) cover the classic German DIN 89158, DIN 89159 and DIN 89160 shipboard elastomer cable family: oil-resistant chloroprene rubber-sheathed MGG, MGCG (90% copper braid) and FMGCG (communication pairs), alongside halogen-free SHF1-sheathed MGH, MGCH, FMGCH, FMGCCH and mica fire-resistant -FFR builds—combining Class 2 or Class 5 stranded copper with 85–90 °C HEPR rubber insulation for European vessel refits and heavy machinery decks.
MGCG, FMGCG, MGG, MGH, MGCH and FMGCH (-FFR) bring together the complete German DIN 89158, DIN 89159 and DIN 89160 marine shipboard elastomer cable series: MGG (unscreened rubber power), MGCG and MGCG(EMC) (90% copper-braided rubber power), MGH and MGCH (halogen-free SHF1 power), FMGCG / FMGCH / FMGCCH (copper-braided twisted-pair marine signal and communication cables) and -FFR mica fire-resistant safety editions.
Across European-built commercial fleets, dredgers, ferries, naval support ships and older offshore platforms, vessel drawings continue to call out DIN 'MG' designations because HF HEPR (high-modulus ethylene-propylene rubber) insulation offers superior tear resistance, mechanical vibration damping and cold-weather flexibility during dry-dock refits. Choosing the outer sheath letter tailors the cable to each compartment: 'G' (MGG, MGCG, FMGCG) specifies heavy black chloroprene rubber (SE1) for aggressive engine-room oil, fuel and bilge exposure, while 'H' (MGH, MGCH, FMGCH) upgrades the outer jacket to zero-halogen, low-smoke SHF1 for passenger zones and modern enclosed decks.
Specify MGCG, MGCH or FMGCG whenever shipyard drawings, refit BOMs or marine superintendents require exact DIN 89158/89159/89160 HEPR elastomer equivalents; choose M2XH / M2XCH for slimmer modern XLPE-insulated IEC 60092-353 builds, or NEK 606 RFOU/BFOU for mud-resistant offshore drilling units. Minimum order 50 m; lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
MGCG, FMGCG, MGG & MGCH DIN 89158–89160 Construction
Classic DIN 89158/89159/89160 shipboard elastomer design pairing stranded copper with HF HEPR rubber insulation, 90% copper braid screen and SE1 chloroprene rubber or SHF1 halogen-free sheath.

| Component | Material and construction |
|---|---|
| 1. Stranded Electrolytic Copper Conductor (Class 2 or Class 5) | Annealed plain copper per IEC 60228 Class 2 (flexible Class 5 and/or tinned copper on request) from 0.75 mm² to 300 mm². |
| 2. HF HEPR Rubber Insulation (+ Optional Mica Tape on -FFR) | Halogen-free high-modulus EPR elastomer rated 0.6/1 kV (power) or 150/250 V (communication pairs), with overlapping mica glass tape on -FFR versions. |
| 3. Elastomer / Halogen-Free Bedding & Separator Foil | Rubber filler bedding (G series) or halogen-free bedding (H series) cushioning the core against shipboard deck vibration. |
| 4. 90% Bare Copper Wire Braid Screen (+ 100% Copper Tape on EMC) | Electrolytic copper wire braid (minimum 90% coverage) on MGCG, MGCH, FMGCG and FMGCH; MGCG(EMC) and MGCH(EMC) add an overlapping copper tape layer. |
| 5. Black Chloroprene Rubber (SE1) or Halogen-Free SHF1 Outer Sheath | Oil- and flame-retardant black polychloroprene rubber (G series) or zero-halogen low-smoke SHF1 compound (H series) rated -30 °C to +85 °C / +90 °C. |
MGCG / FMGCG / MGG DIN 89158–89160 Letter-Code Breakdown
- F / (blank): F = telecommunication / signal pair cable (DIN 89159, 150/250 V); blank = 0.6/1 kV power cable
- MG: Marine shipboard cable (M) with HF HEPR rubber elastomer insulation (G)
- C / CC / (blank): C = 90% overall copper wire braid; CC = individual + overall braid; blank = unscreened (MGG/MGH)
- G / H: Outer sheath chemistry: G = oil-resistant SE1 chloroprene rubber; H = zero-halogen low-smoke SHF1
- (EMC) / -FFR: (EMC) adds 100% overlapping copper tape over braid; -FFR adds mica fire-barrier tape per IEC 60331
MGCG, MGCH & FMGCG European Shipyard & Refit Applications
Trusted across European dry-dock refits, inland/coastal vessels, dredgers, workboats and ocean-going machinery rooms.

- Direct 1:1 replacement and dry-dock refits on European-built ships originally wired to DIN 89158, DIN 89159 and DIN 89160.
- Engine-room auxiliary machinery, fuel-purifier modules, bilge areas and open-deck winches needing oil-resistant SE1 chloroprene rubber (MGG / MGCG).
- Passenger decks, bridge consoles and accommodation power/signal trunks specifying zero-halogen HEPR/SHF1 constructions (MGH / MGCH / FMGCH).
- Emergency power and steering-gear refits utilizing mica-taped MGH-FFR and MGCH-FFR fire-survival DIN cables.
MGCG / MGCH (DIN 89158) vs M2XCH vs NEK 606 RFOU
| Cable Family | Insulation / Sheath | Key Advantage | Best Selection Scenario |
|---|---|---|---|
| MGCG / FMGCG (this page) | HEPR / SE1 Chloroprene | Heavy oil & mechanical rubber toughness | European ship refits, engine rooms & oily bilge zones |
| MGCH / FMGCH (this page) | HEPR / SHF1 LSZH | Flexible HEPR core + zero-halogen sheath | DIN 89158 vessels upgrading to halogen-free safety |
| M2XH / M2XCH / M2XSH | XLPE / SHF1 LSZH | Lighter weight & slimmer tray diameter | Modern IEC 60092-353 new-build vessels & ferries |
| NEK 606 RFOU / BFOU | EPR / SHF2 Mud-Res. | Drilling-mud immersion resistance | Offshore oil/gas drilling rigs & FPSO process modules |
Need an exact drop-in for legacy DIN 89158/89159 drawings? Match MGCG (oil-resistant SE1) or MGCH (halogen-free SHF1) directly to preserve gland OD compatibility.
MGCG, MGCH & FMGCG Marine Cable RFQ Checklist
- Exact DIN designation: MGG, MGCG, MGCG(EMC), MGH, MGCH, MGCH-FFR, FMGCG, FMGCH or FMGCCH.
- Sheath requirement: oil-resistant SE1 chloroprene rubber (G) vs halogen-free low-smoke SHF1 (H).
- Core or pair count and cross-section (0.75–300 mm²) plus conductor class (Class 2 or Class 5, bare or tinned).
- Order length per item (MOQ 50 m) and any vessel refit cut-length or inspection requirements (lead time 7 to 45 working days).
Related selection resources
- Compare Slimmer XLPE-Insulated M2XH / M2XCH / M2XSH Shipboard Cables
- Compare XLPE-Insulated FM2XCH / FM2XAAH Marine Communication Cables
- Explore M2XH-FFR & M2XCH-FFR IEC 60331 Fire-Resistant Marine Cables
- Explore German Naval VG 95218-28 Lightweight Shipboard Cables
- Browse Complete Marine & Offshore Shipboard Cable Catalog
- Explore Shipboard & Offshore Marine Cable Solutions Hub
MGCG, FMGCG, MGG & MGCH DIN 89158 Marine Cable FAQ
What is the difference between MGCG and MGCH shipboard power cables?
Both share HF HEPR rubber insulation and a 90% copper wire braid screen per DIN 89158, but MGCG uses an oil-resistant black chloroprene rubber (SE1) outer sheath whereas MGCH uses a zero-halogen, low-smoke SHF1 outer sheath for enclosed passenger and modern vessel spaces.
How do DIN 89158, DIN 89159 and DIN 89160 map to MGCG, FMGCG and MGG?
DIN 89158 covers copper-braid-screened marine power cables (MGCG / MGCH), DIN 89159 covers copper-screened marine telecommunication and signal cables (FMGCG / FMGCH / FMGCCH), and DIN 89160 covers unscreened marine power cables (MGG / MGH).
How does MGCG compare with M2XCH for a new shipboard installation?
MGCG uses resilient HEPR rubber insulation and SE1 chloroprene rubber sheathing (slightly heavier and highly oil-tough for refits), while M2XCH uses lighter XLPE insulation and SHF1 halogen-free sheathing per modern IEC 60092-353 designs.
Are MGH and MGCH available in fire-resistant -FFR versions?
Yes. MGH-FFR and MGCH-FFR incorporate overlapping phlogopite mica glass fire-barrier tapes over every copper conductor to support IEC 60331 emergency circuit integrity.
What is the MOQ and delivery lead time for MGCG, MGCH and FMGCG marine cables?
50 m minimum order per size, custom-manufactured to DIN 89158/89159/89160 specifications in 7 to 45 working days.
MGCG, FMGCG, MGG, MGH & MGCH Dimension Schedule
MGCG / MGCH Electrical, Elastomer & Shielding Ratings
- Two outer-sheath chemistries (G vs H): G-suffix (MGG/MGCG/FMGCG) uses tough oil-resistant chloroprene rubber (SE1); H-suffix (MGH/MGCH/FMGCH) uses zero-halogen SHF1
- 90% bare copper braid + EMC copper tape option: MGCG, MGCH, FMGCG and FMGCH feature minimum 90% electrolytic copper braiding; MGCG(EMC) / MGCH(EMC) add 100% copper tape
- HF HEPR thermoset rubber insulation: Resilient ethylene-propylene rubber dielectric absorbs shipboard hull vibration, oil mist and thermal shock better than stiff thermoplastics
- Power (0.6/1 kV) & signal (150/250 V) + -FFR: Unified DIN 89158/89159/89160 coverage from 0.75 mm² communication pairs up to 300 mm² power feeders, with optional mica -FFR
- 50 m MOQ for refit & new-build compatibility: Exact dimensional drop-in for European shipyards and fleet maintenance managers, delivered in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (3.5 kV test) for MGG/MGCG/MGH/MGCH power; 150/250 V AC (1.5 kV test) for FMGCG/FMGCH/FMGCCH |
| Insulation and outer sheath | HF HEPR rubber insulation with black oil-resistant SE1 chloroprene rubber (G) or halogen-free SHF1 (H) outer jacket |
| EMC shielding coverage | Minimum 90% bare copper wire braid on C-types; additional 100% overlapping copper tape on (EMC) versions |
| Operating temperature range | -30 °C to +85 °C / +90 °C fixed service (-15 °C minimum installation; 4 × D to 6 × D bending radius) |
| Standard design lineage | DIN 89158 (MGCG/MGCH power), DIN 89159 (FMGCG/FMGCH communication), DIN 89160 (MGG/MGH unscreened) and IEC 60092 |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
MGCG, FMGCG, MGG, MGH & MGCH DIN 89158–89160 Dimension Schedule
| Model & Size (mm²) | Voltage Rating | Insulation / Sheath | Screen & Fire Tier | Nominal OD (mm) | Approx. Weight (kg/km) | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| MGG 3×2.5 | 0.6/1 kV | HEPR / SE1 Rubber | Unscreened | 12.4 | 225 | 50 m | Request this size |
| MGCG 3×1.5 | 0.6/1 kV | HEPR / SE1 Rubber | 90% Cu Braid | 12.2 | 220 | 50 m | Request this size |
| MGCG 4×10 | 0.6/1 kV | HEPR / SE1 Rubber | 90% Cu Braid | 20.2 | 745 | 50 m | Request this size |
| MGCG 3×35 | 0.6/1 kV | HEPR / SE1 Rubber | 90% Cu Braid | 28.2 | 1,690 | 50 m | Request this size |
| MGCG (EMC) 3×50 | 0.6/1 kV | HEPR / SE1 Rubber | Cu Tape + 90% Braid | 33.6 | 2,420 | 50 m | Request this size |
| MGH 4×16 | 0.6/1 kV | HEPR / SHF1 LSZH | Unscreened | 21.4 | 865 | 50 m | Request this size |
| MGCH 3×25 | 0.6/1 kV | HEPR / SHF1 LSZH | 90% Cu Braid | 25.0 | 1,310 | 50 m | Request this size |
| MGCH 3×95 | 0.6/1 kV | HEPR / SHF1 LSZH | 90% Cu Braid | 42.4 | 4,080 | 50 m | Request this size |
| MGCH-FFR 3×16 | 0.6/1 kV | Mica+HEPR / SHF1 | Mica + 90% Cu Braid | 22.8 | 960 | 50 m | Request this size |
| FMGCG 4×2×0.75 | 150/250 V | HEPR / SE1 Rubber | 90% Cu Braid | 14.8 | 295 | 50 m | Request this size |
| FMGCH 7×2×0.75 | 150/250 V | HEPR / SHF1 LSZH | 90% Cu Braid | 17.4 | 415 | 50 m | Request this size |
| FMGCCH 4×2×0.75 | 150/250 V | HEPR / SHF1 LSZH | Ind. + Overall Braid | 16.8 | 395 | 50 m | Request this size |
Both Class 2 standard shipboard stranding and Class 5 flexible conductors (bare or tinned copper) are produced across 1-core to 37-core power and 1-pair to 37-pair communication layouts. Specify MGCG(EMC) or MGCH(EMC) when an additional 100% copper tape is needed for VFD or high-EMI zones.
ASCII part references for BOM and ERP entry: MGG-3x2.5, MGCG-3x1.5, MGCG-4x10, MGCG-3x35, MGCG-EMC-3x50, MGH-4x16, MGCH-3x25, MGCH-3x95, MGCH-FFR-3x16, FMGCG-4x2x0.75, FMGCH-7x2x0.75, FMGCCH-4x2x0.75.
MGCG / FMGCG DIN 89158–89160 & IEC 60092 Marine Standards
| Standard or specification | Application |
|---|---|
| DIN 89158, DIN 89159 & DIN 89160 | German marine cable construction standards for copper-screened power (MGCG/MGCH), communication (FMGCG/FMGCH) and unscreened power (MGG/MGH) cables. |
| IEC 60092-353 / -376 & IEC 60332-3-22 Cat. A | Shipboard power/control design and bunched vertical flame-propagation reference (with IEC 60754 & IEC 61034 on H halogen-free versions). |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing and routine electrical QA records
DIN 89158 — Electric Cables for Ships and Offshore Units: Screened Power Cables (MGCG / MGCH)
IEC 60092-353 — Electrical Installations in Ships: Power Cables for 1 kV and 3 kV
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
M2XH, M2XCH & M2XSH 0.6/1 kV Halogen-Free Shipboard Power Cable (IEC 60092-353)
A related cable option for a different application or duty profile.
View productFM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable
A related cable option for a different application or duty profile.
View productM2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.