BS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable
BS 6708 Type 830 is a heavy-duty 6.35/11 kV AC (25 kV routine test voltage) flexible mining trailing power cable built for large underground and open-pit mining machinery. Featuring three IEC 60228 Class 5 flexible tinned copper phase conductors (50 mm² to 150 mm²), 7.5 mm radial EPR insulation, composite tinned-copper and nylon braided individual phase screens laid up in direct contact (with an additional 16 mm² central bare copper earth on 120 and 150 mm² sizes) and a thick 7.4–9.1 mm heavy-duty chloroprene rubber outer sheath.
BS 6708 Type 830 is a 6.35/11 kV (25 kV AC test) three-core individually screened flexible mining trailing cable engineered to British Standard BS 6708 for high-horsepower underground longwall substations, continuous miners, draglines, electric rope shovels and mobile quarry crushers.
Operating at 11 kV dramatically lowers trailing-cable current and voltage drop over long mine headings compared with 1.1 kV or 3.3 kV feeders, but demands uncompromising earth-fault containment and mechanical tear resistance. BS 6708 Type 830 pairs extra-flexible IEC 60228 Class 5 tinned electrolytic copper conductors (396 to 756 fine strands per phase) with a generous 7.5 mm EPR elastomer insulation wall. Each phase core is enclosed in a composite tinned-copper wire and nylon yarn braided screen; all three screened cores are laid up in intimate mutual contact—and around a 16 mm² bare copper central earth core on 3×120 and 3×150 mm² sizes—so any rock-fall penetration hits grounded screen before reaching live 11 kV copper. A 7.4 to 9.1 mm heavy-duty black chloroprene rubber sheath provides rugged abrasion, oil and flame resistance.
Specify BS 6708 Type 830 for 6.35/11 kV British-standard underground and open-pit trailing machinery; choose BS 6708 Type 62/63/64 for 640/1,100 V pliable armoured feeders, or German DIN VDE 0250-813 NTSCGEWÖU-TR / (N)TMCGEH3S where semiconductive-screened DIN/VDE MV trailing cables are specified. Minimum order 50 m; lead time 7 to 45 working days.
Explore the mining and tunneling cable range for related configurations.
BS 6708 Type 830 6.35/11 kV EPR & Composite-Screen Construction
Heavy-duty 6.35/11 kV BS 6708 trailing architecture combining Class 5 tinned copper, 7.5 mm EPR dielectric, composite tinned-copper/nylon braided individual phase screens, optional central earth and 7.4–9.1 mm PCP sheath.

| Component | Material and construction |
|---|---|
| 1. Class 5 Flexible Tinned Copper Phase Conductors | IEC 60228 Class 5 finely stranded tinned electrolytic copper (50, 70, 95, 120 and 150 mm²) resisting underground sulfurous moisture corrosion. |
| 2. 7.5 mm Radial EPR High-Voltage Insulation | High-dielectric cross-linked ethylene-propylene rubber sized for 6.35/11 kV AC service and 25 kV AC factory routine withstand testing. |
| 3. Composite Tinned-Copper / Nylon Braided Individual Phase Screens | Flexible hybrid metallic-textile braid over each insulated phase core provides continuous symmetrical earth-fault screening without work-hardening fracture. |
| 4. Contact Lay-Up & Central Bare Copper Earth (120–150 mm²) | All three composite-screened phase cores laid tightly in contact (and around a 1×16 mm² bare Class 5 copper central earth core on 120 and 150 mm² sizes). |
| 5. 7.4–9.1 mm Heavy-Duty Chloroprene Rubber Outer Sheath | Extra-thick tear-, abrasion-, oil- and flame-resistant black polychloroprene rubber (PCP) engineered for underground mine roadways and open-pit benches. |
BS 6708 Type 830 Specification & Core-Layout Breakdown
- BS 6708: British Standard specification for flexible elastomer trailing cables in coal mines and quarries
- Type 830: 6.35/11 kV individually composite-screened 3-core trailing cable construction (25 kV AC test)
- Class 5 Tinned Cu: Finely stranded flexible tinned electrolytic copper resisting mine humidity and flexing fatigue
- Composite Screen: Tinned copper wire + nylon yarn individual braid screens laid in direct mutual earth contact
- +16 Central Earth: 1×16 mm² bare copper central earth core integrated on 3×120+16 and 3×150+16 mm² sizes
BS 6708 Type 830 Deep-Mine & Open-Pit Trailing Applications
Engineered for 6.35/11 kV mobile and semi-mobile power delivery across deep underground mines and heavy surface excavations.

- 6.35/11 kV main trailing supply to high-capacity underground mobile substations, roadheaders and longwall shearer power packs.
- Open-pit electric mining shovels, bucket-wheel excavators, blast-hole drills and mobile primary crushers using British BS 6708 electrical grids.
- Deep underground mine roadways with explosive methane gas or coal dust where individual earth-screened phase containment is mandatory.
- Heavy quarry and aggregate plant portable 11 kV power distribution between transportable switchgear skids.
BS 6708 Type 830 (11 kV) vs Type 62–64 vs NTSCGEWÖU-TR
| Mining Cable Series | Rated Voltage | Screen & Armour Build | Primary Mine Deployment |
|---|---|---|---|
| BS 6708 Type 830 (this page) | 6.35/11 kV (25 kV test) | Composite Cu/nylon phase braids + heavy PCP | UK/Commonwealth 11 kV underground & open-pit trailing machines |
| BS 6708 Type 62 / 63 / 64 | 640/1,100 V | Pliable galvanized steel wire strand armour | 1.1 kV underground roadway feeders & portable coal machinery |
| NTSCGEWÖU-TR (DIN VDE 0250) | 3.6/6 to 18/30 kV | Semicon screens + split earth + 5GM5 rubber | High-voltage open-pit draglines, shovels & mobile crushers |
| (N)TMCGEH3S 6/10 kV | 6/10 kV | Concentric Cu screen + heavy elastomer | 6/10 kV tunneling & underground hard-rock trailing feeders |
Always confirm coupler/plug gland OD tolerance (75.0 to 103.0 mm) and earth-continuity protection settings when ordering 11 kV Type 830 assemblies.
BS 6708 Type 830 11 kV Mining Cable RFQ Checklist
- Exact BS 6708 Type 830 size: 3×50, 3×70, 3×95, 3×120+16 or 3×150+16 mm².
- Installation environment (deep underground roadway vs surface open-pit bench) and required high-visibility sheath color (black standard, yellow/red on request).
- Required continuous cut lengths per drum (MOQ 50 m) and cable-coupler gland diameter clearance.
- Factory routine 25 kV AC HV withstand and conductor/screen DC resistance documentation (lead time 7 to 45 working days).
Related selection resources
- Explore BS 6708 Type 62 / 63 / 64 640/1,100 V Armoured Mining Cables
- Compare NTSCGEWÖU-TR 3.6/6–18/30 kV Open-Pit Shovel Trailing Cables
- Compare (N)TMCGEH3S 6/10 kV Underground Mining Trailing Cables
- Explore UGF & UGEFP High-Voltage Open-Pit Mining Cables
- Browse Complete Mining & Tunneling Cable Catalog
- Explore Mining & Tunneling Cable Engineering Solutions
BS 6708 Type 830 6.35/11 kV Mining Trailing Cable FAQ
What voltage and routine test level does BS 6708 Type 830 carry?
6.35/11 kV AC (6,350/11,000 V) rated voltage with a 25 kV AC factory routine test voltage and 7.5 mm nominal EPR insulation thickness across all five cross-sections.
Why does BS 6708 Type 830 use composite tinned-copper and nylon braided phase screens?
Weaving fine tinned copper wires with high-tensile nylon yarn prevents metallic screen fracture during repeated mining-floor bends while maintaining continuous 0.26 to 0.68 Ω/km earth-fault paths around all three phases.
Which BS 6708 Type 830 sizes include a central bare copper earth conductor?
The two largest sizes—3×120+16 mm² and 3×150+16 mm²—incorporate a 1×16 mm² (126/0.40 mm) bare copper central earth core laid up in direct contact with all three composite phase screens.
Can BS 6708 Type 830 be deployed in both underground and surface open-pit mines?
Yes. Its 7.4 to 9.1 mm heavy-duty chloroprene rubber sheath and individually screened phase geometry are designed for both deep underground explosive-gas/dust roadways and rugged surface mining benches.
What is the MOQ and production lead time for BS 6708 Type 830 cables?
50 m minimum order per size, custom-manufactured and 25 kV routine HV tested in 7 to 45 working days.
BS 6708 Type 830 Dimensional & Electrical Schedule
BS 6708 Type 830 Voltage, Ampacity & Resistance Ratings
- Top-tier 6.35/11 kV BS 6708 rating: 25 kV AC routine test voltage with 7.5 mm nominal EPR dielectric wall engineered for 11 kV mine feeders and trailing reels
- Composite tinned-copper / nylon phase screens: Individual braided phase screens laid in mutual contact equalize earth-fault paths and resist flex fatigue during constant dragging
- Central bare copper earth on 120–150 mm²: 3×120+16 and 3×150+16 mm² constructions integrate a 16 mm² central bare copper earth conductor in parallel with all three phase screens
- Heavy-duty 7.4–9.1 mm chloroprene sheath: Tear-, oil-, abrasion- and flame-resistant heavy polychloroprene rubber outer jacket built for wet roadways and explosive-dust mines
- 50 m MOQ across 3×50 to 3×150+16 mm²: Class 5 flexible tinned copper strands (170 A to 320 A at 25 °C ambient), custom-manufactured in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 6.35/11 kV AC (6,350/11,000 V), 25 kV AC routine withstand test voltage per BS 6708 |
| Conductor and insulation | IEC 60228 Class 5 flexible tinned copper (3×50 to 3×150+16 mm²) with 7.5 mm nominal EPR insulation |
| Phase screen and earth system | Composite tinned-copper/nylon braided individual phase screens in contact plus 1×16 mm² central bare earth on 120 and 150 mm² |
| Outer sheath and diameter range | 7.4 to 9.1 mm heavy-duty chloroprene rubber (PCP) outer sheath, overall diameter 75.0 to 103.0 mm |
| Continuous current and bending | 170 A to 320 A continuous at 25 °C ambient; minimum bending radius 830 to 1,030 mm (10 × D) |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
BS 6708 Type 830 6.35/11 kV Dimensional & Electrical Schedule
| Model & Size (mm²) | Phase Stranding / Dia (mm) | Sheath Wall (mm) | Overall OD Min–Max (mm) | Approx. Weight (kg/km) | Current @25 °C (A) | Max DC R @20 °C (Ω/km) | Next step |
|---|---|---|---|---|---|---|---|
| BS 6708 Type 830 3×50 | 396/0.40 · Ø 10.1 | 7.4 | 75.0–83.0 | 7,600 | 170 | 0.393 | Request this size |
| BS 6708 Type 830 3×70 | 360/0.50 · Ø 11.9 | 7.9 | 80.6–86.0 | 9,150 | 205 | 0.277 | Request this size |
| BS 6708 Type 830 3×95 | 475/0.50 · Ø 13.9 | 8.3 | 85.9–91.0 | 10,700 | 250 | 0.210 | Request this size |
| BS 6708 Type 830 3×120+16 | 608/0.50 · Ø 15.5 (+16E) | 8.7 | 89.9–96.5 | 12,400 | 295 | 0.164 | Request this size |
| BS 6708 Type 830 3×150+16 | 756/0.50 · Ø 17.2 (+16E) | 9.1 | 93.3–103.0 | 13,600 | 320 | 0.132 | Request this size |
All five Type 830 sizes feature 7.5 mm nominal EPR insulation, 25 kV AC factory test voltage, 10 × D minimum bending radius (830–1,030 mm) and parallel screen/earth DC resistance of 0.68, 0.55, 0.42, 0.32 and 0.26 Ω/km respectively. Minimum order 50 m per size.
ASCII part references for BOM and ERP entry: BS6708-TYPE830-3x50, BS6708-TYPE830-3x70, BS6708-TYPE830-3x95, BS6708-TYPE830-3x120+16, BS6708-TYPE830-3x150+16.
BS 6708 & IEC 60228 Mining Trailing Standards
| Standard or specification | Application |
|---|---|
| BS 6708 | British Standard specification for flexible trailing cables for use in coal mines and quarries (Type 830, 6.35/11 kV). |
| IEC 60228 Class 5 & IEC 60332-1-2 | Flexible tinned copper conductor stranding resistance and single-cable vertical flame-retardance reference. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing QA and routine 25 kV HV test records
BSI — BS 6708 Flexible Trailing Cables for Mines and Quarries
IEC 60228 — Conductors of Insulated Cables (Class 5 Flexible Copper)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
BS 6708 Type 62 / 63 / 64 Armoured Cable 640/1100 V
A related cable option for a different application or duty profile.
View productNTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable
A related cable option for a different application or duty profile.
View product(N)TMCGEH3S 6/10 kV Mining Trailing Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.