NTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable
NTSCGEWÖU-TR (NTSCGEWOEU-TR) is a medium-voltage open-pit trailing cable built with reference to DIN VDE 0250-813 across six voltage classes from 3.6/6 kV up to 18/30 kV (3×25+3×25/3 to 3×185+3×95/3 mm²), featuring an embedded tear-resistant reinforcing grid tape between heavy-duty black 5GM5 rubber sheaths for ±100 °/m torsion and -35 °C flexible (-50 °C fixed) bench dragging.
NTSCGEWÖU-TR / NTSCGEWOEU-TR open-pit trailing cable supplies 3.6/6 kV through 18/30 kV power (Umax up to 20.8/36 kV AC) to electric rope shovels, walking draglines, hydraulic face excavators and mobile pit crushers, combining class 5 tinned-copper 3GI3 EPR phases, three semiconductive-elastomer split earth cores, a tear-resistant reinforcing grid tape and a black 5GM5 rubber sheath.
When a 70 to 100 mm medium-voltage cable is dragged across blasted granite, iron-ore or overburden benches by cable-handler tractors or slewing shovel booms, sharp rock edges initiate surface nicks that propagate rapidly under ±100 °/m torsional twist and 8 kN drawbar pull. Unlike unreinforced trailing builds where a rock gash can peel open the outer jacket, NTSCGEWÖU-TR bonds a high-tenacity reinforcing grid tape between the inner and outer 5GM5 elastomer layers. The open-mesh grid locks both rubber sheaths into one composite wall, arresting longitudinal tear propagation and preventing core corkscrewing without sacrificing cold-weather flexibility down to -35 °C dynamic (-50 °C fixed).
Specify NTSCGEWÖU-TR whenever medium-voltage cables are dragged directly on rough pit floors or hauled on slewing excavators. For motorised bucket-wheel excavator or crane drums use R-(N)TSCGEWÖU reeling cable, for North American metallic-shielded couplers use SHD-GC, and for underground monorail festoons use (N)TSKCGECWÖU-FN.
Explore the mining and tunneling cable range for related configurations.
NTSCGEWÖU-TR Grid-Reinforced Trailing Cable Construction
NTSCGEWÖU-TR is manufactured on catenary continuous vulcanization (CCV) triple-extrusion and heavy-sheath lines with reference to DIN VDE 0250-813.

| Component | Material and construction |
|---|---|
| 1. Phase conductors | Finely stranded tinned copper wires, class 5 to IEC 60228 (25 to 185 mm²). |
| 2. MV stress control & insulation | Co-extruded inner semiconductive layer, EPR compound type 3GI3 to DIN VDE 0207-20, and outer semiconductive insulation shield. |
| 3. Split protective earth | Three class 5 tinned copper earth conductors enclosed in semiconductive rubber, laid symmetrically in the three outer interstices. |
| 4. Inner sheath | Heavy-duty rubber compound type 5GM5 to DIN VDE 0207-21. |
| 5. Anti-tear grid reinforcement | High-strength tear-resistant reinforcing grid tape locking the inner and outer sheaths against transverse cuts and axial sheath creep. |
| 6. Outer sheath | Abrasion- and tear-enhanced black 5GM5 rubber sheath to DIN VDE 0207-21 (LOI above 29), oil, UV and ozone resistant, inkjet marked. |
NTSCGEWÖU-TR Designation Breakdown
- NT: Flexible medium-voltage rubber trailing cable built with reference to DIN VDE 0250-813
- SC: Semiconductive elastomer field-control screens over the phase insulation and split earth cores
- GE: 3GI3 ethylene-propylene rubber (EPR) medium-voltage core insulation
- WÖU: Weather, oil (Ö) and flame-retardant (U) heavy-duty 5GM5 rubber sheath
- -TR: Tear-resistant open-pit design with reinforcing grid tape embedded between inner and outer sheaths
NTSCGEWÖU-TR Open-Pit Shovel and Dragline Applications
NTSCGEWÖU-TR is built for extreme mechanical dragging, rock abrasion and sub-zero ambient conditions in surface mines.

- Bench-trailing feeder cables for electric rope shovels, walking draglines and heavy hydraulic mining excavators (3.6/6 to 18/30 kV).
- Open-pit copper, iron-ore, gold, coal and lignite mines using skid substations and tire-mounted cable-handling equipment.
- Mobile in-pit crushing and conveying (IPCC) hoppers, blast-hole drills and overburden spreaders.
- Cold-climate surface mines requiring -35 °C flexible trailing and -50 °C fixed cold withstand.
NTSCGEWÖU-TR vs Reeling, Conveyor and SHD-GC Cables
| Cable family | Mechanical duty | Reinforcement & earth screen | Voltage span |
|---|---|---|---|
| NTSCGEWÖU-TR (this page) | Open-pit shovel & dragline bench trailing (±100 °/m) | Anti-tear grid tape + 3 semiconductive split earths | 3.6/6 to 18/30 kV |
| R-(N)TSCGEWÖU | Motorised reeling drums on BWEs & stackers | Anti-torsion textile braid between sheaths | 3.6/6 to 18/30 kV |
| F-(N)TSCGEWÖU | Shiftable pit conveyors & semi-fixed feeders | Standard trailing sheath without grid reinforcement | 3.6/6 to 18/30 kV |
| Type SHD-GC (ICEA) | North American coupler-connected shovel trailing | Metallic copper braid/tape phase shields + ground-check | 2 kV to 25 kV |
ASCII search equivalents: NTSCGEWOEU-TR 6/10 kV 3x70+3x35/3; (N)TSCGEWOEU-TR 8.7/15 kV; NTSCGEWOU-TR 12/20 kV; NTSCGEWOEU-TR 18/30 kV shovel cable.
NTSCGEWÖU-TR Open-Pit Trailing Cable RFQ Checklist
- Rated voltage class (3.6/6, 6/10, 8.7/15, 12/20, 14/25 or 18/30 kV) and system maximum voltage.
- Phase and split-earth cross-section (3x25+3x25/3 up to 3x185+3x95/3 mm², including 3x50+3x50/3 or 3x150+3x50/3 options).
- Equipment type (rope shovel, dragline, hydraulic excavator, drill) and coupler gland entry diameter range.
- Minimum winter bench ambient temperature, altitude and continuous pit-piece length per reel.
- Total order quantity and delivery target (MOQ 50 m; manufacturing lead time 7 to 45 working days).
Related selection resources
- Mining and tunneling cable catalog
- Mining and tunneling cable solutions by equipment
- Engineering guide: medium-voltage mining cable selection (3.3 to 35 kV)
- Engineering guide: tear and abrasion resistant sheaths for mobile mining cables
- R-(N)TSCGEWÖU 3.6/6–18/30 kV motorised drum reeling cable
- F-(N)TSCGEWÖU 3.6/6–18/30 kV shiftable conveyor mining cable
- NTSCGEWOEU-W 3.6/6–18/30 kV water-resistant mining cable
- Field guide: mining trailing cable damage modes and protection
NTSCGEWÖU-TR Trailing Cable FAQ
What does the -TR suffix add to NTSCGEWÖU-TR?
1 embedded high-strength tear-resistant reinforcing grid tape between the inner and outer 5GM5 rubber sheaths, stopping rock cuts from tearing open the jacket and rated for ±100 °/m torsion.
Which voltage ratings are covered by NTSCGEWÖU-TR?
6 medium-voltage ratings: 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 14/25 kV and 18/30 kV (with 50 Hz factory AC test voltages of 11, 17, 24, 29, 36 and 43 kV).
How cold can NTSCGEWÖU-TR operate in open-pit mines?
-35 °C to +80 °C during flexible trailing movement and -50 °C to +90 °C in fixed installation, with a 90 °C continuous conductor rating.
Does NTSCGEWÖU-TR use metallic phase screens or semiconductive elastomer screens?
3 semiconductive elastomer phase insulation shields in radial contact with 3 semiconductive-covered tinned-copper earth cores in the interstices, per DIN VDE 0250-813.
What are the MOQ and lead time for NTSCGEWÖU-TR?
50 m minimum order quantity across all 6 voltage classes, with a factory lead time of 7 to 45 working days.
NTSCGEWÖU-TR 3.6/6–18/30 kV Technical Data and Size Schedule
NTSCGEWÖU-TR Key Voltage, Torsion and Sub-Zero Ratings
- 6 MV voltage classes: Full schedule covering 3.6/6, 6/10, 8.7/15, 12/20, 14/25 and 18/30 kV (AC test 11 to 43 kV)
- Tear-resistant grid (-TR): Reinforcing grid tape embedded between the inner and outer 5GM5 sheaths stops transverse cuts and sheath slip
- ±100 °/m torsional rating: Withstands ±100 °/m twist plus 15 N/mm² phase pull when dragged behind slewing electric rope shovels and draglines
- Sub-zero bench service: -35 °C to +80 °C flexible operation and -50 °C to +90 °C fixed installation with UV, ozone and oil resistance
- Custom pit lengths: 3x25 to 3x185 mm² across all 6 voltage levels manufactured from MOQ 50 m in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 14/25 kV and 18/30 kV U0/U |
| Conductor range | 3x25+3x25/3 mm² to 3x185+3x95/3 mm² class 5 tinned copper |
| Reinforcement and sheath | Tear-resistant reinforcing grid tape between black 5GM5 inner and outer rubber sheaths |
| Torsion and tension | Up to 100 deg/m bidirectional torsion and 15 N/mm² phase tensile load (1,125 to 8,325 N) |
| Temperature envelope | -35 °C to +80 °C flexible trailing, -50 °C to +90 °C fixed, 90 °C conductor (250 °C short-circuit) |
| AC test voltages | 11 kV (3.6/6), 17 kV (6/10), 24 kV (8.7/15), 29 kV (12/20), 36 kV (14/25), 43 kV (18/30 kV) |
| Supply terms | MOQ 50 m; manufacturing lead time 7 to 45 working days |
NTSCGEWÖU-TR 3.6/6 kV to 18/30 kV Multi-Voltage Schedule
| Model, voltage and size | Rated U0/U | Outer diameter min–max (mm) | Max. DC resistance at 20 °C (Ω/km) | Current at 30 °C (A) | Approx. weight (kg/km) | Max. tensile load (N) | Next step |
|---|---|---|---|---|---|---|---|
| NTSCGEWOEU-TR 3.6/6 kV 3x25+3x25/3 | 3.6/6 kV | 44–47 | 0.795 | 131 | 2,855 | 1,125 | Request this size |
| NTSCGEWOEU-TR 3.6/6 kV 3x50+3x25/3 | 3.6/6 kV | 51–54 | 0.393 | 202 | 3,963 | 2,250 | Request this size |
| NTSCGEWOEU-TR 3.6/6 kV 3x95+3x50/3 | 3.6/6 kV | 60–63 | 0.210 | 301 | 6,214 | 4,275 | Request this size |
| NTSCGEWOEU-TR 3.6/6 kV 3x150+3x70/3 | 3.6/6 kV | 68–71 | 0.132 | 404 | 8,484 | 6,750 | Request this size |
| NTSCGEWOEU-TR 6/10 kV 3x35+3x25/3 | 6/10 kV | 49–52 | 0.565 | 162 | 3,503 | 1,575 | Request this size |
| NTSCGEWOEU-TR 6/10 kV 3x70+3x35/3 | 6/10 kV | 58–61 | 0.277 | 250 | 5,370 | 3,150 | Request this size |
| NTSCGEWOEU-TR 6/10 kV 3x120+3x70/3 | 6/10 kV | 65–68 | 0.164 | 352 | 7,592 | 5,400 | Request this size |
| NTSCGEWOEU-TR 6/10 kV 3x185+3x95/3 | 6/10 kV | 76–79 | 0.108 | 461 | 10,621 | 8,325 | Request this size |
| NTSCGEWOEU-TR 8.7/15 kV 3x35+3x25/3 | 8.7/15 kV | 54–57 | 0.565 | 172 | 4,113 | 1,575 | Request this size |
| NTSCGEWOEU-TR 8.7/15 kV 3x70+3x35/3 | 8.7/15 kV | 63–66 | 0.277 | 265 | 6,086 | 3,150 | Request this size |
| NTSCGEWOEU-TR 8.7/15 kV 3x120+3x70/3 | 8.7/15 kV | 71–74 | 0.164 | 371 | 8,426 | 5,400 | Request this size |
| NTSCGEWOEU-TR 8.7/15 kV 3x185+3x95/3 | 8.7/15 kV | 82–85 | 0.108 | 488 | 11,591 | 8,325 | Request this size |
| NTSCGEWOEU-TR 12/20 kV 3x35+3x25/3 | 12/20 kV | 60–63 | 0.565 | 172 | 4,762 | 1,575 | Request this size |
| NTSCGEWOEU-TR 12/20 kV 3x70+3x35/3 | 12/20 kV | 69–72 | 0.277 | 265 | 6,836 | 3,150 | Request this size |
| NTSCGEWOEU-TR 12/20 kV 3x120+3x70/3 | 12/20 kV | 76–79 | 0.164 | 371 | 9,226 | 5,400 | Request this size |
| NTSCGEWOEU-TR 12/20 kV 3x185+3x95/3 | 12/20 kV | 87–90 | 0.108 | 488 | 12,473 | 8,325 | Request this size |
| NTSCGEWOEU-TR 14/25 kV 3x50+3x25/3 | 14/25 kV | 71–74 | 0.393 | 215 | 6,553 | 2,250 | Request this size |
| NTSCGEWOEU-TR 14/25 kV 3x95+3x50/3 | 14/25 kV | 80–83 | 0.210 | 319 | 9,204 | 4,275 | Request this size |
| NTSCGEWOEU-TR 14/25 kV 3x150+3x70/3 | 14/25 kV | 88–91 | 0.132 | 428 | 11,802 | 6,750 | Request this size |
| NTSCGEWOEU-TR 18/30 kV 3x35+3x25/3 | 18/30 kV | 72–75 | 0.565 | 172 | 6,533 | 1,575 | Request this size |
| NTSCGEWOEU-TR 18/30 kV 3x70+3x35/3 | 18/30 kV | 81–84 | 0.277 | 265 | 8,847 | 3,150 | Request this size |
| NTSCGEWOEU-TR 18/30 kV 3x120+3x70/3 | 18/30 kV | 89–92 | 0.164 | 371 | 11,431 | 5,400 | Request this size |
| NTSCGEWOEU-TR 18/30 kV 3x185+3x95/3 | 18/30 kV | 100–103 | 0.108 | 488 | 15,014 | 8,325 | Request this size |
All eight phase cross-sections (25, 35, 50, 70, 95, 120, 150 and 185 mm², plus 3x50+3x50/3, 3x150+3x50/3 and 3x185+3x50/3 in 6/10 kV) are manufactured across every voltage class from 3.6/6 kV to 18/30 kV.
1-second phase short-circuit current ratings are 3.20 kA (25 mm²), 4.48 kA (35 mm²), 6.40 kA (50 mm²), 8.96 kA (70 mm²), 12.16 kA (95 mm²), 15.36 kA (120 mm²), 19.20 kA (150 mm²) and 23.68 kA (185 mm²).
ASCII part references: NTSCGEWOEU-TR 3.6/6 kV 3x50+3x25/3; NTSCGEWOEU-TR 6/10 kV 3x70+3x35/3; NTSCGEWOEU-TR 8.7/15 kV 3x120+3x70/3; NTSCGEWOEU-TR 12/20 kV; NTSCGEWOEU-TR 18/30 kV 3x185+3x95/3.
NTSCGEWÖU-TR Standards and Test References
| Standard or specification | Application |
|---|---|
| DIN VDE 0250-813 (reference) | Construction and high-voltage AC withstand test reference (11 kV to 43 kV) for MV trailing cables. |
| IEC 60228 | Class 5 finely stranded tinned copper phase and split protective-earth conductors. |
| DIN VDE 0207-20 / 0207-21 | 3GI3 EPR MV dielectric and tear-improved 5GM5 inner/outer heavy rubber compounds. |
| DIN EN / IEC 60332-1-2 | Flame retardance verification (sheath oxygen index LOI above 29). |
| DIN EN / IEC 60811-404 | Oil resistance test for elastomer outer sheaths. |
| DIN VDE 0298-3 / 0298-4 | Minimum trailing bend radius and ambient/drum current derating tables. |
Certifications and document support
TEBAOFLEX ISO quality assurance and routine factory test reports
DIN Media — DIN VDE 0250-813 / 0298-3 / 0298-4 standards reference
IEC Webstore — IEC 60228 conductor, IEC 60332 flame and IEC 60811 oil test references
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
R-(N)TSCGEWÖU Medium Voltage Reeling Cable 3.6/6–18/30 kV
For continuous drum reeling and higher dynamic movement.
View productF-(N)TSCGEWÖU Medium Voltage Conveyor & Mining Cable 3.6/6–18/30 kV
For festoon and conveyor routes with repeated travel.
View product3.6/6kV to 18/30kV NTSCGEWOEU-W Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.