MINING & TUNNELING CABLES TEBAOFLEX

BS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable

BS 6708 Type 830 is a heavy-duty 6.35/11 kV AC (25 kV routine test voltage) flexible mining trailing power cable built for large underground and open-pit mining machinery. Featuring three IEC 60228 Class 5 flexible tinned copper phase conductors (50 mm² to 150 mm²), 7.5 mm radial EPR insulation, composite tinned-copper and nylon braided individual phase screens laid up in direct contact (with an additional 16 mm² central bare copper earth on 120 and 150 mm² sizes) and a thick 7.4–9.1 mm heavy-duty chloroprene rubber outer sheath.

Product information
SKU
TF-BS6708-830
Brand
TEBAOFLEX
Product overview

BS 6708 Type 830 is a 6.35/11 kV (25 kV AC test) three-core individually screened flexible mining trailing cable engineered to British Standard BS 6708 for high-horsepower underground longwall substations, continuous miners, draglines, electric rope shovels and mobile quarry crushers.

Operating at 11 kV dramatically lowers trailing-cable current and voltage drop over long mine headings compared with 1.1 kV or 3.3 kV feeders, but demands uncompromising earth-fault containment and mechanical tear resistance. BS 6708 Type 830 pairs extra-flexible IEC 60228 Class 5 tinned electrolytic copper conductors (396 to 756 fine strands per phase) with a generous 7.5 mm EPR elastomer insulation wall. Each phase core is enclosed in a composite tinned-copper wire and nylon yarn braided screen; all three screened cores are laid up in intimate mutual contact—and around a 16 mm² bare copper central earth core on 3×120 and 3×150 mm² sizes—so any rock-fall penetration hits grounded screen before reaching live 11 kV copper. A 7.4 to 9.1 mm heavy-duty black chloroprene rubber sheath provides rugged abrasion, oil and flame resistance.

Specify BS 6708 Type 830 for 6.35/11 kV British-standard underground and open-pit trailing machinery; choose BS 6708 Type 62/63/64 for 640/1,100 V pliable armoured feeders, or German DIN VDE 0250-813 NTSCGEWÖU-TR / (N)TMCGEH3S where semiconductive-screened DIN/VDE MV trailing cables are specified. Minimum order 50 m; lead time 7 to 45 working days.

Explore the mining and tunneling cable range for related configurations.

Construction

BS 6708 Type 830 6.35/11 kV EPR & Composite-Screen Construction

Heavy-duty 6.35/11 kV BS 6708 trailing architecture combining Class 5 tinned copper, 7.5 mm EPR dielectric, composite tinned-copper/nylon braided individual phase screens, optional central earth and 7.4–9.1 mm PCP sheath.

Clean 2D technical cross-section of BS 6708 Type 830 6.35/11 kV mining trailing cable showing thick black PCP outer sheath, three large white EPR cores wrapped in silvery composite copper nylon braid screens around a central bare copper earth core
BS 6708 Type 830 cross-section showing three touching composite-screened EPR phase cores around a central bare copper earth inside a 7.4–9.1 mm PCP sheath.
BS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable construction
ComponentMaterial and construction
1. Class 5 Flexible Tinned Copper Phase ConductorsIEC 60228 Class 5 finely stranded tinned electrolytic copper (50, 70, 95, 120 and 150 mm²) resisting underground sulfurous moisture corrosion.
2. 7.5 mm Radial EPR High-Voltage InsulationHigh-dielectric cross-linked ethylene-propylene rubber sized for 6.35/11 kV AC service and 25 kV AC factory routine withstand testing.
3. Composite Tinned-Copper / Nylon Braided Individual Phase ScreensFlexible hybrid metallic-textile braid over each insulated phase core provides continuous symmetrical earth-fault screening without work-hardening fracture.
4. Contact Lay-Up & Central Bare Copper Earth (120–150 mm²)All three composite-screened phase cores laid tightly in contact (and around a 1×16 mm² bare Class 5 copper central earth core on 120 and 150 mm² sizes).
5. 7.4–9.1 mm Heavy-Duty Chloroprene Rubber Outer SheathExtra-thick tear-, abrasion-, oil- and flame-resistant black polychloroprene rubber (PCP) engineered for underground mine roadways and open-pit benches.

BS 6708 Type 830 Specification & Core-Layout Breakdown

  • BS 6708: British Standard specification for flexible elastomer trailing cables in coal mines and quarries
  • Type 830: 6.35/11 kV individually composite-screened 3-core trailing cable construction (25 kV AC test)
  • Class 5 Tinned Cu: Finely stranded flexible tinned electrolytic copper resisting mine humidity and flexing fatigue
  • Composite Screen: Tinned copper wire + nylon yarn individual braid screens laid in direct mutual earth contact
  • +16 Central Earth: 1×16 mm² bare copper central earth core integrated on 3×120+16 and 3×150+16 mm² sizes
Applications

BS 6708 Type 830 Deep-Mine & Open-Pit Trailing Applications

Engineered for 6.35/11 kV mobile and semi-mobile power delivery across deep underground mines and heavy surface excavations.

Heavy underground mine roadway with thick black BS 6708 Type 830 11 kV high-voltage mining trailing cable suspended on insulated hooks supplying an electric mining machine
Underground and surface mining 11 kV power delivery using heavy-duty flexible BS 6708 Type 830 trailing cables.
  • 6.35/11 kV main trailing supply to high-capacity underground mobile substations, roadheaders and longwall shearer power packs.
  • Open-pit electric mining shovels, bucket-wheel excavators, blast-hole drills and mobile primary crushers using British BS 6708 electrical grids.
  • Deep underground mine roadways with explosive methane gas or coal dust where individual earth-screened phase containment is mandatory.
  • Heavy quarry and aggregate plant portable 11 kV power distribution between transportable switchgear skids.

BS 6708 Type 830 (11 kV) vs Type 62–64 vs NTSCGEWÖU-TR

BS 6708 Type 830 (11 kV) vs BS 6708 Type 62–64 (1.1 kV) vs DIN NTSCGEWÖU-TR (6–30 kV)
Mining Cable SeriesRated VoltageScreen & Armour BuildPrimary Mine Deployment
BS 6708 Type 830 (this page)6.35/11 kV (25 kV test)Composite Cu/nylon phase braids + heavy PCPUK/Commonwealth 11 kV underground & open-pit trailing machines
BS 6708 Type 62 / 63 / 64640/1,100 VPliable galvanized steel wire strand armour1.1 kV underground roadway feeders & portable coal machinery
NTSCGEWÖU-TR (DIN VDE 0250)3.6/6 to 18/30 kVSemicon screens + split earth + 5GM5 rubberHigh-voltage open-pit draglines, shovels & mobile crushers
(N)TMCGEH3S 6/10 kV6/10 kVConcentric Cu screen + heavy elastomer6/10 kV tunneling & underground hard-rock trailing feeders

Always confirm coupler/plug gland OD tolerance (75.0 to 103.0 mm) and earth-continuity protection settings when ordering 11 kV Type 830 assemblies.

BS 6708 Type 830 11 kV Mining Cable RFQ Checklist

  • Exact BS 6708 Type 830 size: 3×50, 3×70, 3×95, 3×120+16 or 3×150+16 mm².
  • Installation environment (deep underground roadway vs surface open-pit bench) and required high-visibility sheath color (black standard, yellow/red on request).
  • Required continuous cut lengths per drum (MOQ 50 m) and cable-coupler gland diameter clearance.
  • Factory routine 25 kV AC HV withstand and conductor/screen DC resistance documentation (lead time 7 to 45 working days).

Related selection resources

BS 6708 Type 830 6.35/11 kV Mining Trailing Cable FAQ

What voltage and routine test level does BS 6708 Type 830 carry?

6.35/11 kV AC (6,350/11,000 V) rated voltage with a 25 kV AC factory routine test voltage and 7.5 mm nominal EPR insulation thickness across all five cross-sections.

Why does BS 6708 Type 830 use composite tinned-copper and nylon braided phase screens?

Weaving fine tinned copper wires with high-tensile nylon yarn prevents metallic screen fracture during repeated mining-floor bends while maintaining continuous 0.26 to 0.68 Ω/km earth-fault paths around all three phases.

Which BS 6708 Type 830 sizes include a central bare copper earth conductor?

The two largest sizes—3×120+16 mm² and 3×150+16 mm²—incorporate a 1×16 mm² (126/0.40 mm) bare copper central earth core laid up in direct contact with all three composite phase screens.

Can BS 6708 Type 830 be deployed in both underground and surface open-pit mines?

Yes. Its 7.4 to 9.1 mm heavy-duty chloroprene rubber sheath and individually screened phase geometry are designed for both deep underground explosive-gas/dust roadways and rugged surface mining benches.

What is the MOQ and production lead time for BS 6708 Type 830 cables?

50 m minimum order per size, custom-manufactured and 25 kV routine HV tested in 7 to 45 working days.

Specifications

BS 6708 Type 830 Dimensional & Electrical Schedule

BS 6708 Type 830 Voltage, Ampacity & Resistance Ratings

  • Top-tier 6.35/11 kV BS 6708 rating: 25 kV AC routine test voltage with 7.5 mm nominal EPR dielectric wall engineered for 11 kV mine feeders and trailing reels
  • Composite tinned-copper / nylon phase screens: Individual braided phase screens laid in mutual contact equalize earth-fault paths and resist flex fatigue during constant dragging
  • Central bare copper earth on 120–150 mm²: 3×120+16 and 3×150+16 mm² constructions integrate a 16 mm² central bare copper earth conductor in parallel with all three phase screens
  • Heavy-duty 7.4–9.1 mm chloroprene sheath: Tear-, oil-, abrasion- and flame-resistant heavy polychloroprene rubber outer jacket built for wet roadways and explosive-dust mines
  • 50 m MOQ across 3×50 to 3×150+16 mm²: Class 5 flexible tinned copper strands (170 A to 320 A at 25 °C ambient), custom-manufactured in 7 to 45 working days
BS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable technical data
ParameterValue
Rated voltage6.35/11 kV AC (6,350/11,000 V), 25 kV AC routine withstand test voltage per BS 6708
Conductor and insulationIEC 60228 Class 5 flexible tinned copper (3×50 to 3×150+16 mm²) with 7.5 mm nominal EPR insulation
Phase screen and earth systemComposite tinned-copper/nylon braided individual phase screens in contact plus 1×16 mm² central bare earth on 120 and 150 mm²
Outer sheath and diameter range7.4 to 9.1 mm heavy-duty chloroprene rubber (PCP) outer sheath, overall diameter 75.0 to 103.0 mm
Continuous current and bending170 A to 320 A continuous at 25 °C ambient; minimum bending radius 830 to 1,030 mm (10 × D)
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

BS 6708 Type 830 6.35/11 kV Dimensional & Electrical Schedule

BS 6708 Type 830 6.35/11 kV Mining Trailing Cable Exact Dimensional & Electrical Schedule
Model & Size (mm²)Phase Stranding / Dia (mm)Sheath Wall (mm)Overall OD Min–Max (mm)Approx. Weight (kg/km)Current @25 °C (A)Max DC R @20 °C (Ω/km)Next step
BS 6708 Type 830 3×50396/0.40 · Ø 10.17.475.0–83.07,6001700.393Request this size
BS 6708 Type 830 3×70360/0.50 · Ø 11.97.980.6–86.09,1502050.277Request this size
BS 6708 Type 830 3×95475/0.50 · Ø 13.98.385.9–91.010,7002500.210Request this size
BS 6708 Type 830 3×120+16608/0.50 · Ø 15.5 (+16E)8.789.9–96.512,4002950.164Request this size
BS 6708 Type 830 3×150+16756/0.50 · Ø 17.2 (+16E)9.193.3–103.013,6003200.132Request this size

All five Type 830 sizes feature 7.5 mm nominal EPR insulation, 25 kV AC factory test voltage, 10 × D minimum bending radius (830–1,030 mm) and parallel screen/earth DC resistance of 0.68, 0.55, 0.42, 0.32 and 0.26 Ω/km respectively. Minimum order 50 m per size.

ASCII part references for BOM and ERP entry: BS6708-TYPE830-3x50, BS6708-TYPE830-3x70, BS6708-TYPE830-3x95, BS6708-TYPE830-3x120+16, BS6708-TYPE830-3x150+16.

Standards

BS 6708 & IEC 60228 Mining Trailing Standards

BS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable standards and test references
Standard or specificationApplication
BS 6708British Standard specification for flexible trailing cables for use in coal mines and quarries (Type 830, 6.35/11 kV).
IEC 60228 Class 5 & IEC 60332-1-2Flexible tinned copper conductor stranding resistance and single-cable vertical flame-retardance reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing QA and routine 25 kV HV test records

BSI — BS 6708 Flexible Trailing Cables for Mines and Quarries

IEC 60228 — Conductors of Insulated Cables (Class 5 Flexible Copper)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.