UGF & UGEFP High-Voltage Open-Pit Mining Trailing Cable (3.6/6–6/10 kV)
High-voltage flexible rubber trailing cables (UGF 3.6/6 kV, UGF 6/10 kV, UGEFP 3.6/6 kV and UGEFP 6/10 kV) engineered for open-pit mining electric rope shovels, hydraulic excavators, bucket-wheel excavators, rotary blast-hole drills and mobile transformers. Built with Class 5 tinned copper conductors, triple-extruded +90 °C EPR insulation, semiconductive or tinned-copper composite phase shields, an interstitial grounding core and a weather-, oil- and cold-resistant (-40 °C) chloroprene/CPE outer sheath.
UGF and UGEFP high-voltage mining trailing cables are designed for surface and open-pit mining machinery operating on 3.6/6 kV and 6/10 kV three-phase distribution networks.Dragged over blasted haul-road rock, wound onto mobile cable skids or guided over boom sheaves on electric rope shovels and large blast-hole drills, these cables combine medium-voltage dielectric integrity with extreme mechanical impact, abrasion and cold-bend resilience.
In the standard UGF construction (3+1 cores, 16 mm² to 150 mm²), three Class 5 flexible tinned-copper power cores are insulated with +90 °C ethylene-propylene rubber (EPR) between extruded inner and outer semiconductive elastomer screens, laid up around a semiconductive rubber center cradle with an uninsulated flexible tinned-copper earth conductor in direct contact with the three phase screens.
In the metallic-shielded UGEFP construction, each power core adds an individual tinned-copper wire and synthetic-fibre composite metallic shield over the outer semiconductive layer, providing enhanced fault-current capacity and electrostatic screening for long open-pit feeder runs and variable-frequency shovel drives. Standard and cold-climate formulations operate across ambient temperatures down to -40 °C while resisting solar UV, ozone, oil and acid pit water.
Provide the rated voltage (3.6/6 kV or 6/10 kV), model (UGF or UGEFP), conductor cross-section, minimum ambient site temperature and coupler requirement with your enquiry. TEBAOFLEX manufactures custom lengths from a 50 m minimum order quantity with a standard lead time of 7–45 working days.
Explore the mining and tunneling cable range for related configurations.
For North American ICEA S-75-381 and Chinese MT 818 medium-voltage mining trailing cables, compare these constructions: SHD-GC Cable 2kV-25kV Mining Power Cable (for 2 kV to 25 kV braided-copper-shielded portable power feeds on open-pit shovels and draglines); MYPTJ Monitored Medium-Voltage Mining Trailing Cable (3.6/6–8.7/10 kV) (for 3.6/6 kV to 8.7/10 kV underground coal mining trailing service with semi-conductive screening and ground monitoring). Confirm rated voltage, minimum ambient operating temperature (-25°C vs -40°C), and earth-check architecture before ordering.
Construction
The representative construction illustrates UGEFP 6/10 kV 3×70 + 1×25 mm²: three equal Class 5 flexible tinned-copper power cores with inner semiconductive screen, +90 °C EPR medium-voltage insulation, outer semiconductive screen and tinned-copper composite metallic shield, plus one flexible tinned-copper earth conductor in the interstitial valley, cabled around a semiconductive profile center and enclosed in a light-grey inner bedding, reinforcing braid and heavy-duty black cold- and weather-resistant chloroprene/CPE outer sheath.

| Component | Material and construction |
|---|---|
| Power conductors | Three Class 5 flexible rope-lay stranded tinned copper conductors per GB/T 3956 / IEC 60228 (16 mm² to 150 mm²). |
| Conductor & insulation screens | Extruded inner and outer semiconductive elastomer layers vulcanized integrally with the EPR dielectric. |
| High-voltage insulation | Ozone- and corona-resistant +90 °C ethylene-propylene rubber (EPR), 4.5 mm nominal wall thickness for 3.6/6 kV and 5.5 mm for 6/10 kV. |
| Phase shield (UGF vs. UGEFP) | UGF: semiconductive elastomer phase screen in continuous contact with the interstitial earth conductor. UGEFP: tinned-copper wire and synthetic-yarn composite metallic shield over each power core. |
| Earth / grounding conductor | One flexible stranded tinned-copper grounding conductor (10 mm² to 50 mm²) laid in the interstitial valley. |
| Reinforcement & outer jacket | Elastomeric inner bedding, open-weave reinforcing braid and heavy-duty black polychloroprene (PCP/CR) or chlorinated polyethylene (CPE) outer jacket rated for -40 °C to +90 °C open-pit service. |
Applications
Choose UGF for standard semiconductive-screened open-pit trailing service or UGEFP where individual metallic phase shielding is required by high-voltage earth-fault protection relays.

- Open-pit mining electric rope shovels, walking draglines and large hydraulic face shovels operating at 6 kV or 10 kV.
- High-voltage rotary blast-hole drill rigs, bucket-wheel excavators and mobile crusher units on surface mine benches.
- Mobile skid-mounted substations and open-pit ring-main trailing feeders dragged across rock benches and haul-road cable bridges.
- Cold-region surface mining operations down to -40 °C ambient temperature with minimum dynamic bending radius of 6 × D (UGF) to 10 × D (UGEFP).
When evaluating shielded high-voltage trailing cables for surface mines and quarries, consult these pages: What Does Type SHD Mean in Mining Cables? (for metallic shield construction, ground-check conductor placement, and voltage stress control principles); Type SHD-CGC 5 kV Shielded Portable Mining Power Cable (for 5 kV heavy-duty portable mining power feeds with a central ground-check conductor). Verify drag tension, rock impact exposure, and splice kit compatibility for your pit layout.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage (U0/U) | 3.6/6 kV and 6/10 kV |
| Maximum continuous conductor temperature | +90 °C (+250 °C short-circuit, 5 s max.) |
| Ambient operating temperature range | -40 °C to +50 °C (cold-resistant open-pit compound) |
| Core configuration | 3 screened power cores + 1 interstitial grounding core (3+1) |
| Power frequency AC test voltage | 11 kV / 5 min (3.6/6 kV); 15 kV / 5 min (6/10 kV) |
| Minimum dynamic bending radius | 6 × cable outside diameter (UGF); 10 × cable outside diameter (UGEFP) |
| Sunlight, ozone and oil resistance | UV-stabilized, ozone-resistant and mineral-oil-resistant heavy-duty thermosetting rubber outer sheath |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7–45 working days |
| Model & voltage rating | Nominal cross-section (power + earth, mm²) | Nominal EPR insulation thickness (mm) | Nominal outer sheath thickness (mm) | Nominal outside diameter min–max (mm) | Continuous ampacity at 25 °C ambient (A) | Approx. weight — UGF / UGEFP (kg/km) |
|---|---|---|---|---|---|---|
| UGF / UGEFP-3.6/6 kV | 3×16 + 1×10 | 4.5 | 4.5 | 40.2 – 44.5 | 85 | 2,180 / 2,390 |
| UGF / UGEFP-3.6/6 kV | 3×25 + 1×16 | 4.5 | 4.5 | 43.6 – 48.2 | 113 | 2,720 / 2,960 |
| UGF / UGEFP-3.6/6 kV | 3×35 + 1×16 | 4.5 | 4.5 | 46.2 – 51.0 | 138 | 3,210 / 3,480 |
| UGF / UGEFP-3.6/6 kV | 3×50 + 1×16 | 4.5 | 5.0 | 50.8 – 56.0 | 173 | 4,020 / 4,340 |
| UGF / UGEFP-3.6/6 kV | 3×70 + 1×25 | 4.5 | 5.0 | 55.2 – 60.8 | 215 | 5,040 / 5,410 |
| UGF / UGEFP-3.6/6 kV | 3×95 + 1×25 | 4.5 | 5.5 | 60.8 – 66.8 | 260 | 6,280 / 6,710 |
| UGF / UGEFP-3.6/6 kV | 3×120 + 1×35 | 4.5 | 5.5 | 64.6 – 71.0 | 300 | 7,450 / 7,920 |
| UGF / UGEFP-3.6/6 kV | 3×150 + 1×50 | 4.5 | 6.0 | 70.2 – 77.0 | 345 | 8,960 / 9,490 |
| UGF / UGEFP-6/10 kV | 3×16 + 1×10 | 5.5 | 5.0 | 45.4 – 50.2 | 85 | 2,640 / 2,880 |
| UGF / UGEFP-6/10 kV | 3×25 + 1×16 | 5.5 | 5.0 | 48.8 – 53.8 | 113 | 3,210 / 3,490 |
| UGF / UGEFP-6/10 kV | 3×35 + 1×16 | 5.5 | 5.0 | 51.4 – 56.6 | 138 | 3,740 / 4,050 |
| UGF / UGEFP-6/10 kV | 3×50 + 1×16 | 5.5 | 5.5 | 56.2 – 61.8 | 173 | 4,610 / 4,960 |
| UGF / UGEFP-6/10 kV | 3×70 + 1×25 | 5.5 | 5.5 | 60.6 – 66.6 | 215 | 5,680 / 6,090 |
| UGF / UGEFP-6/10 kV | 3×95 + 1×25 | 5.5 | 6.0 | 66.2 – 72.8 | 260 | 6,980 / 7,450 |
| UGF / UGEFP-6/10 kV | 3×120 + 1×35 | 5.5 | 6.0 | 70.0 – 77.0 | 300 | 8,190 / 8,710 |
| UGF / UGEFP-6/10 kV | 3×150 + 1×50 | 5.5 | 6.5 | 75.6 – 83.2 | 345 | 9,780 / 10,360 |
Continuous ampacities are stated for +90 °C conductor temperature at +25 °C ambient air; apply ambient temperature and solar radiation derating for exposed summer bench runs.
When UGF or UGEFP cables are operated on multi-layer mobile cable reels, apply standard wound-layer ampacity derating factors.
Custom split-earth (3+3) or integrated pilot-core variants can be manufactured to project specification.
Standards
| Standard or specification | Application |
|---|---|
| JB/T 8137 / GB/T 12972 | High-voltage flexible rubber-sheathed trailing cables for open-pit mining shovels and mobile machinery (Types UGF and UGEFP). |
| GB/T 3956 / IEC 60228 | Class 5 flexible tinned copper conductors for mobile trailing cables. |
| IEC 60502-2 | Extruded solid dielectric (EPR) and semiconductive screening system reference for 6 kV and 10 kV cables. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
SHD-GC Cable 2kV-25kV Mining Power Cable
A related cable option for a different application or duty profile.
View productDrilling Mast Cable 600–2000 V — Blast-Hole Drill Power and Control Cable
A related cable option for a different application or duty profile.
View productMYPTJ Monitored Medium-Voltage Mining Trailing Cable (3.6/6–8.7/10 kV)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.