Case 23 · Oman · Industrial MV Motor Overhaul · 5 kV 200 °C Silicone Motor Lead

5 kV 200 °C 1×150 mm² Cross-Linked Silicone Rubber Motor Lead Cable for Industrial Motor Overhaul in Oman

An electromechanical motor overhaul and rewinding facility in Oman required a flexible 5 kV, +200 °C single-core 1 × 150 mm² stator motor lead cable capable of routing tightly from internal stator coil connections through underside metallic compression glands to external terminal lugs. TEBAOFLEX manufactured the custom dual-layer cross-linked silicone rubber construction—pairing finely stranded annealed bare copper, a non-hygroscopic polyester separator, 2.00 mm yellow cross-linked silicone primary insulation and a 1.90 mm smooth white cross-linked silicone outer sheath (26.15 mm nominal OD)—and shipped the lagged wooden export drum to Oman, where the leads were terminated and installed onto the overhauled motor.

Medium-voltage industrial motor in Oman fitted with coiled white TEBAOFLEX 5 kV 200 °C 1×150 mm² cross-linked silicone rubber motor lead cable and crimped copper compression lug
Workshop completion photo from Oman: overhauled medium-voltage industrial motor fitted with white TEBAOFLEX 5 kV 200 °C 1×150 mm² cross-linked silicone motor leads, heat-shrink stress sleeves and crimped copper compression lugs.

Project at a glance

This Oman industrial motor project supplied TEBAOFLEX 5 kV +200 °C 1 × 150 mm² flexible single-core motor lead cable built with finely stranded annealed bare copper, a polyester separator tape, 2.00 mm yellow cross-linked silicone insulation and a 1.90 mm braidless white cross-linked silicone outer sheath at 26.15 mm nominal outside diameter.

Summary of the Oman 5 kV 200 °C 1×150 mm² cross-linked silicone motor lead cable order
Order itemVerified engineering detail
Destination & applicationOman — medium-voltage industrial motor stator-to-terminal lead connection and workshop overhaul
Supplied designationTEBAOFLEX 5 kV 200 °C Silicone Motor Lead Cable, 1 × 150 mm² (single-core braidless dual-wall elastomer)
Conductor & separator150 mm² finely stranded annealed electrolytic bare copper (IEC 60228 flexible stranding) + non-hygroscopic polyester separator tape
Dual cross-linked silicone wallPrimary insulation: 2.00 mm yellow cross-linked silicone rubber · Outer sheath: 1.90 mm smooth white cross-linked silicone rubber
Nominal OD & cable mass26.15 mm nominal outside diameter · 1,739 kg/km nominal cable weight
Thermal & environmental ratingContinuous conductor stability up to +200 °C; low-temperature flexibility down to −60 °C / −70 °C; ozone-, grease-, moisture- and weak-acid-resistant
Sheath markingTEBAOFLEX 5KV 200°C SILICONE CABLE 1Cx150mm² + sequential metre mark
Export drum packageFully lagged wooden export drum (740 × 740 × 700 mm, 108 kg gross weight) strapped on heat-treated pallet with moisture-sealed end caps
Scope note. This engineering record documents the dual-wall cross-linked silicone construction, bare-copper 200 °C metallurgy, compression-gland sealing geometry and Oman workshop installation feedback. Customer organization name, end-plant identity and commercial contract values are omitted under confidentiality.

Why did the Oman motor overhaul require braidless dual-wall 200 °C silicone leads?

Medium-voltage stator leads conduct heat directly out of Class F (155 °C) and Class H (180 °C) motor windings while operating in 45 °C to 50 °C Gulf ambient air. Using a 200 °C cross-linked silicone primary insulation beneath a smooth cross-linked silicone outer sheath avoids both thermal embrittlement and fiberglass-braid gland leakage.

During heavy industrial motor rewinds and stator overhauls, the short single-core jumper between the stator coil knuckle and the main terminal box experiences harsher thermal and mechanical stress than the incoming plant feeder cable. Conventional 90 °C EPR or XLPE power cores stiffen inside compact terminal housings and transmit lever forces onto stator bushings during shaft vibration. Conversely, glass-braided high-temperature leads—such as our 2GTL 180 °C fiberglass-braided silicone motor lead cable—excel in dry ventilated air ducts up to 13.9/15 kV, but woven glass braid cannot seal gas- or oil-tight inside a round elastomer compression gland.

On this Oman motor frame, the two single-core 1 × 150 mm² leads exit the bottom of the stator casing through threaded metallic compression glands before coiling to the terminal lug position. Selecting a smooth, braidless cross-linked silicone outer jacket—aligned with our 5 kV 200 °C braidless single-core silicone rubber cable architecture—solved three workshop constraints simultaneously:

  • 360-degree compression-gland sealing: The concentric 1.90 mm white silicone rubber sheath compresses evenly inside metallic cable glands, blocking desert dust, washdown moisture and bearing-oil mist from entering the stator enclosure.
  • Bare electrolytic copper stability at 200 °C: Because peroxide/addition cross-linked silicone contains zero sulfur vulcanizing agents, finely stranded annealed bare copper (IEC 60228) stays bright without tin plating—avoiding the accelerated copper-tin intermetallic growth that degrades tinned wires above 150 °C (explained in our tinned copper vs bare copper temperature ceiling guide and high-temperature wire insulation ratings guide).
  • Supple coiling in tight terminal envelopes: Fine stranding plus low-modulus silicone elastomer allowed technicians to dress and tie compact service loops right beside the motor shaft without springing back against the compression lugs.
White TEBAOFLEX 5 kV 200 °C 1×150 mm² braidless cross-linked silicone motor leads sealed through twin metallic compression cable glands on the underside of an overhauled industrial motor in Oman
Client workshop photo in Oman: twin white 5 kV 200 °C 1×150 mm² cross-linked silicone leads routed cleanly through underside metallic compression glands on the overhauled motor frame.
Cut-end cross-section of TEBAOFLEX 5 kV 200 °C 1×150 mm² motor lead cable showing finely stranded bare copper conductor, polyester separator tape, 2.0 mm yellow cross-linked silicone insulation and 1.9 mm white silicone outer sheath
Factory cut-end cross-section prior to dispatch: finely stranded 150 mm² bare copper core, polyester separator tape, 2.00 mm yellow primary silicone insulation and 1.90 mm white silicone sheath.

Inside the 5 kV 1×150 mm² yellow/white dual silicone wall and voltage series

At 150 mm² conductor cross-section, the 5 kV 200 °C motor lead series balances a 2.00 mm yellow cross-linked silicone insulation wall with a 1.90 mm white cross-linked silicone outer sheath (3.90 mm total elastomer radial wall, 26.15 mm nominal OD, 1,739 kg/km), sitting between the 3 kV (24.55 mm) and 7 kV (27.75 mm) wall classes.

Schematic cross-section of TEBAOFLEX 5 kV 200 °C 1×150 mm² cross-linked silicone rubber motor lead cable1234
  1. Conductor: 1 × 150 mm² finely stranded annealed electrolytic bare copper (IEC 60228 flexible class; ≤ 0.132 Ω/km Class 5 / ≤ 0.129 Ω/km Class 4 at 20 °C)
  2. Separator layer: non-hygroscopic polyester tape preventing silicone compound intrusion between fine copper strands for clean lug stripping
  3. Primary insulation: 2.00 mm nominal wall yellow cross-linked silicone rubber rated for 5 kV service and +200 °C thermal stability
  4. Outer sheath: 1.90 mm nominal wall white cross-linked silicone rubber (26.15 mm nominal OD; smooth braidless surface for compression gland sealing)
Schematic cross-section of the TEBAOFLEX 5 kV 200 °C 1×150 mm² dual-wall cross-linked silicone motor lead cable supplied to Oman (not to scale).
Dimensional comparison across 3 kV, 5 kV and 7 kV 200 °C 1×150 mm² dual-silicone motor leads vs fiberglass-braided 2GTL
Voltage class & sizeYellow silicone insulation wallWhite silicone sheath wallNominal outside ØNominal massChoose this when
3 kV · 1 × 150 mm²1.50 mm1.60 mm24.55 mm1,664 kg/km2.3 kV to 3.3 kV Class F/H motor stator leads where gland entry bore is restricted below 25 mm
5 kV · 1 × 150 mm² (Oman order)2.00 mm1.90 mm26.15 mm1,739 kg/km3.3 kV to 4.16 kV / 5 kV industrial motors needing sealed compression-gland entry and 200 °C thermal margin
7 kV · 1 × 150 mm²2.50 mm2.20 mm27.75 mm1,820 kg/km6.0 kV to 6.6 kV unshielded internal motor jumpers routed on insulated cleats with extra radial wall margin
2GTL 6.6/7.2 kV · 1 × 150 mm²Silicone + semi-con tapeRubber + glass-fibre braidProject scheduleProject schedule6.6 kV to 13.9/15 kV motors needing semi-conductive stress control and dry external abrasion braid rather than elastomer gland sealing

Two practical shop-floor details stand out in this yellow-inner / white-outer construction. First, placing a non-hygroscopic polyester tape over the 150 mm² flexible copper bundle stops uncured silicone rubber from locking into the outer wire interstices during extrusion, so mechanics in Oman could strip clean, bright copper ends for hydraulic lug crimping without nicking outer strands. Second, contrasting yellow insulation beneath a white jacket acts as a built-in inspection witness if a lead rubs against a motor baseplate or terminal flange. For lower-voltage multi-core 0.6/1 kV high-temperature power feeders in steelworks or kiln zones, compare our YGC / YGCR / YGC22 silicone rubber power cable series.

Sheath marking, factory inspection and 108 kg lagged wooden drum export

Prior to palletizing at our Taicang factory, every metre of the white silicone jacket was ink-marked TEBAOFLEX 5KV 200°C SILICONE CABLE 1Cx150mm² with sequential length numbers, checked for conductor DC resistance and AC dielectric integrity, and enclosed in a 740 × 740 × 700 mm (108 kg gross) lagged wooden export drum.

TEBAOFLEX 5KV 200°C SILICONE CABLE 1Cx150mm² 04M

Black ink-jet sheath marking on white cross-linked silicone jacket reading TEBAOFLEX 5KV 200°C SILICONE CABLE 1Cx150mm² 04M
High-contrast black surface print on the smooth white cross-linked silicone outer sheath verifying voltage class (5 kV), thermal rating (200 °C), 1C×150 mm² cross-section and metre count.
White TEBAOFLEX 5 kV 200 °C 1×150 mm² flexible cross-linked silicone rubber motor lead cable wound smoothly onto a wooden factory reel prior to protective lagging
Finished 5 kV 200 °C 1×150 mm² cross-linked silicone motor lead cable wound onto the factory wooden drum before outer batten lagging.
Fully lagged wooden export drum (740 × 740 × 700 mm, 108 kg gross weight) strapped on a fumigated pallet with green moisture-sealed cable end cap ready for dispatch to Oman
Completed export package (740 × 740 × 700 mm, 108 kg gross weight): steel-strapped wooden batten lagging on a heat-treated pallet with green moisture-sealed end cap.

Every drum release follows the routine verification steps outlined in our cable factory acceptance test (FAT) guide—checking 20 °C conductor DC resistance, concentric insulation/sheath minimum point thickness, surface print legibility and high-voltage AC withstand before capping both ends against sea-freight humidity.

What to specify when ordering 5 kV 200 °C silicone motor lead cables

To match your stator terminal bore, lug barrel and voltage stress requirements on the first quotation, share rated motor voltage, conductor cross-section (1.0 mm² to 240 mm²), gland clamping diameter range, bare vs tinned copper preference and cut reel length.

Send these motor lead parameters for an engineering review before production:
  • Motor nameplate voltage (e.g. 3.3 kV, 4.16 kV, 5 kV, 6.6 kV or 11 kV) and whether semi-conductive stress control is required
  • Conductor cross-section (mm² or AWG/kcmil) and bare electrolytic copper (up to 200 °C) vs tinned copper preference
  • Outer surface requirement: smooth cross-linked silicone sheath (for compression cable glands) vs fiberglass braid (2GTL dry abrasion service)
  • Cable gland clamping ID range (mm), compression lug barrel inside diameter and minimum routing bend radius inside the terminal box
  • Required continuous drum length (from 50 m MOQ), colour coding (such as yellow inner / white outer, red or black) and destination port

As of November 2026, TEBAOFLEX manufactures custom high-temperature silicone and fluoropolymer motor lead cables at our Taicang factory from a 50 m minimum order quantity, with a standard lead time of 7 to 45 working days depending on conductor stranding and extrusion schedule. Explore selection frameworks on our high-temperature wire and cable solutions page or browse all constructions in our high-temperature cables catalogue.

Request a 5 kV 200 °C silicone motor lead quote & datasheet →

Frequently asked questions on 5 kV 200 °C 1×150 mm² silicone motor lead cables

Why use a 200 °C cross-linked silicone motor lead cable instead of 90 °C EPR or XLPE on medium-voltage motors in Oman?

Inside stator terminal housings and frame lead ports on heavy industrial motors in Oman, 45 °C to 50 °C Gulf ambient air combines with Class F (155 °C) or Class H (180 °C) stator winding heat conduction. Standard 90 °C XLPE or EPR leads stiffen and thermally age near the stator exit, whereas cross-linked silicone rubber maintains dielectric integrity and supple bending stability continuously up to +200 °C (and down to −60 °C / −70 °C).

Why did this 5 kV 1×150 mm² build use a smooth white silicone outer sheath instead of an outer fiberglass braid?

As shown in the workshop installation photographs, the two single-core 1×150 mm² stator leads exit the underside of the motor frame through threaded metallic compression cable glands. A woven fiberglass outer braid (such as on 2GTL cables) cannot form an oil- and dust-tight seal under an elastomeric gland compression ring and can wick moisture along glass yarns, whereas a concentric 1.90 mm smooth white cross-linked silicone sheath seals cleanly and wipes free of workshop grease.

Why does this 200 °C silicone motor lead use bare copper instead of tinned copper?

Cross-linked silicone rubber is cured without elemental sulfur, so bare copper strands do not suffer vulcanization sulfide blackening. Furthermore, above 150 °C continuous conductor temperature, tin plating on fine copper wires gradually forms brittle copper-tin intermetallic layers that raise contact resistance; bare electrolytic copper remains stable up to 200 °C when paired with proper compression lugs.

What is the purpose of pairing yellow inner silicone insulation with a white outer silicone sheath?

Extruding a 2.00 mm yellow cross-linked silicone primary dielectric beneath a 1.90 mm white cross-linked silicone outer jacket (3.90 mm combined radial elastomer wall, 26.15 mm nominal OD) gives motor rewinders and maintenance inspectors an immediate visual cut-depth gauge: if mechanical chafing against a terminal box edge exposes yellow compound, crews can replace or sleeve the lead before the primary 5 kV insulation is compromised.

What minimum order quantity and documentation apply to custom 5 kV 200 °C silicone motor lead cables?

As of November 2026, TEBAOFLEX manufactures custom single-core 3 kV, 5 kV and 7 kV 200 °C cross-linked silicone motor lead cables from 1.0 mm² through 240 mm² starting at a 50 m minimum order quantity (MOQ), with standard production lead times of 7 to 45 working days. Factory routine DC resistance, AC dielectric withstand and dimensional inspection records accompany each export drum.