High Temperature Cables TEBAOFLEX

YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)

YGC, extra-flexible YGCR, copper-braid-screened YGCP and double-steel-tape-armoured YGC22 (TF-YGC-YGCR-1KV) are 0.6/1 kV heavy-duty metallurgical silicone rubber power cables rated from -60 °C to +180 °C continuous (+200 °C short-term). Built with IEC 60228 Class 2 or Class 5 copper conductors from 1×4 mm² up to 4×185 mm² and 3×185+1×95 mm² for steelworks, EAF bays, coking plants and cement kilns.

Product information
SKU
TF-YGC-YGCR-1KV
Brand
TEBAOFLEX
Product overview

YGC, extra-flexible YGCR, tinned-copper-screened YGCP and double-steel-tape-armoured YGC22 0.6/1 kV silicone rubber power cables deliver three-phase 380–690 V AC motor power across -60 °C to +180 °C metallurgical hot zones, spanning 1×4 mm² furnace leads up to 3×185+1×95 mm² and 4×185 mm² main feeders (outer diameters 6.2 mm to 72.0 mm).

Standard XLPE, EPR or polychloroprene power cables embrittle and crack within months along continuous-casting run-out tables, EAF transformer galleries, blast-furnace bustle pipes, rotary cement kilns and aluminum potlines, while European 300/500 V SiHF cables top out at light control cross-sections. Combining IEC 60228 copper conductors with thick-wall 0.6/1 kV silicone insulation, alkali-free E-glass thermal bedding and tear-modified silicone rubber outer sheathing preserves dielectric integrity and mechanical flexibility under cyclic thermal shock.

Specify Class 5 extra-flexible YGCR (6× OD minimum bend radius) for mobile transfer bogies, furnace doors and overhead C-track loops; specify YGCP (>= 80 % tinned-copper braid) for VFD-driven hot-gas fans and roller tables; specify YGC22 (helical galvanized steel-tape armour) for cable trenches, catwalks and crush-prone floors; or choose TF-PYRO-SM when direct +1,090 °C molten slag splash hits the cable route. Supplied from a 50 m minimum order quantity (100 m on <= 6 mm²) in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

YGC, YGCR, YGCP & YGC22 0.6/1 kV Silicone Construction

Constructed to 0.6/1 kV metallurgical power cable geometry (JB/T 8735 / GB/T 12706.1 reference and IEC 60228 conductor classes) for continuous +180 °C thermal endurance.

Clean 2D engineering cross-section of YGC22 0.6/1 kV silicone rubber power cable showing reddish-brown silicone outer sheath, concentric galvanized steel tape armour, fiberglass bedding and 3 phase cores plus 1 reduced earth core
3+1 core YGC22 0.6/1 kV cross-section: stranded copper conductors, thick-wall silicone insulation, thermal fiberglass bedding, double steel-tape armour and silicone jacket.
YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C) construction
ComponentMaterial and construction
1. Flexible Bare or Tinned Copper Conductors (IEC 60228)Multi-wire stranded copper on fixed/semi-mobile YGC and YGC22, or extra-fine Class 5 rope-lay bare/tinned annealed copper (0.20–0.50 mm strands) on mobile YGCR and YGCP.
2. 0.6/1 kV Extruded Silicone Rubber Core InsulationHigh-dielectric methyl-vinyl silicone elastomer colour-coded or numbered for phase and protective-earth identification; forms protective non-conductive SiO2 ash under flame.
3. E-Glass Thermal Bedding, Optional EMC Braid (YGCP) or Steel Tape Armour (YGC22)Non-hygroscopic fiberglass fillers and binder tape; >= 80 % tinned-copper braid screen on YGCP, or double helical galvanized steel-tape armour over silicone inner sheath on YGC22.
4. Heavy-Duty Tear-Resistant Silicone Rubber Outer SheathVulcanized brick-red / oxide-red (or black) tear-propagating-resistant silicone rubber jacket resisting +180 °C radiant heat, ozone, UV and industrial furnace fumes.

YGC, YGCR, YGCP & YGC22 Type Designation Breakdown

  • Y: Mobile / heavy-duty industrial power cable series
  • G + C: Silicone rubber core insulation (G) + heavy-duty tear-resistant silicone outer sheath (C)
  • R (in YGCR): Extra-flexible IEC 60228 Class 5 fine-stranded copper conductor for mobile festoon and trolley duty
  • P (in YGCP): Tinned-copper wire braid electromagnetic screen (>= 80 % optical coverage) for VFD motor feeders
  • 22 (in YGC22): Double helical galvanized steel-tape armour with outer silicone protective oversheath
Applications

YGC & YGC22 Steelworks, EAF Bay & Rotary Kiln Feeder Duty

Engineered for 380 V / 400 V / 480 V / 690 V AC three-phase power feeders in metallurgical, glass, cement, coking and power-generation plants.

Reddish-brown YGC22 and YGCR 0.6/1 kV heavy-duty silicone power cables routed along steel trays into a hot-zone roller-table motor junction box inside a steelworks continuous-casting bay
Hot-zone 380–690 V AC continuous-casting roller-table and ladle-bay motor feeders wired with YGC22 and YGCR silicone power cables.
  • Electric arc furnace (EAF) roof-swing auxiliaries, ladle-refining bay blowers, continuous-casting run-out roller tables and billet reheat furnace pushers.
  • Coking-plant pusher/quenching car fixed catwalks, blast-furnace hot-blast stove valve actuators, sinter cooler fans and pelletizing induration grates.
  • Rotary cement kiln shell blowers, clinker cooler drives, float-glass annealing lehr circulation motors and aluminum smelter anode baking furnaces.
  • Overseas EPC steelworks and non-ferrous smelter projects specifying Chinese/IEC BOM codes YGC, YGCR, YGCP, YGC22, JGGF or JGGR.

YGC / YGC22 (0.6/1 kV) vs SiHF vs FEP-GSWB vs Reeling Cable

YGC / YGCR / YGC22 (0.6/1 kV) vs SiHF-J (300/500 V) vs FEP/PFA-GSWB vs Ladle Reeling Cable
Cable FamilyVoltage & Section SpanProtection & Duty EnvelopeWhen to Specify
YGC / YGCR / YGCP / YGC22 (this page)0.6/1 kV; 1.5–185 mm² (1–5C)-60 to +180 °C heavy silicone; optional EMC braid or steel-tape armourMain 380–690 V hot-zone motor feeders, furnace trays, trenches & festoons
SiHF / SiHF-J & SiHF-P300/500 V; 0.75–16 mm²-60 to +180 °C EN 50525-2-83 light silicone (unarmoured or GSWB)European 230/400 V light auxiliary drives, heaters and luminaire drops
FEP/PFA-GSWB / PFA-SSWB0.6/1 kV; 1.5–35 mm²-60 to +260 °C fluoropolymer + steel wire braidHot ester hydraulic oil, acid pickling tanks or >+180 °C chemical splash
Ladle Transfer Car Reeling Cable0.6/1 kV; 4–95 mm²Aramid anti-torsion braid + high-tension motorized drum reeling sheathConstant spring/motorized drum reeling on floor ladle transfer bogies

Do not install standard YGC or YGCR on high-tension motorized cable reels; specify dedicated aramid-reinforced Ladle Transfer Car Reeling Cable for continuous drum winding.

YGC, YGCR, YGCP & YGC22 Silicone Power Cable RFQ Checklist

  • Exact model code (YGC fixed, YGCR Class 5 mobile, YGCP copper-screened, or YGC22 steel-tape armoured) and core × mm² size.
  • Conductor finish preference: bare copper (standard) or tinned copper (recommended for sulfurous coking/pickling atmospheres).
  • Installation mode (fixed tray/trench, C-track festoon, or short flexible machine loop) and maximum ambient radiant temperature (°C).
  • Total meterage and individual drum cut lengths (MOQ 50 m on >= 10 mm², 100 m on <= 6 mm²; 7 to 45 working days).

Related selection resources

YGC, YGCR, YGCP & YGC22 Silicone Power Cable FAQ

What is the difference between YGC, YGCR, YGCP and YGC22 silicone power cables?

YGC uses standard flexible stranded copper for fixed hot-zone trays and short machine drops; YGCR upgrades to extra-fine IEC 60228 Class 5 copper (6× OD bend radius) for mobile trolleys and furnace doors; YGCP adds an >= 80 % tinned-copper EMC braid for VFD motor drives; and YGC22 adds double galvanized steel-tape armour for crush and rodent protection in trenches.

When do I need 0.6/1 kV YGC / YGCR instead of 300/500 V SiHF silicone cable?

Specify 0.6/1 kV YGC or YGCR whenever supplying three-phase 380–690 V AC industrial motors above 4–10 kW, long melt-shop feeder runs from 16 mm² to 185 mm², or circuits requiring a 3,500 V AC 5-minute dielectric test where 300/500 V SiHF insulation walls are under-rated.

Can YGC or YGCR be used on motorized steel-mill ladle transfer car cable drums?

No — standard silicone rubber sheaths tear under continuous high-tension drum reeling and guide-roller torsion; YGCR suits C-track festoons and free-hanging loops, whereas motorized ladle car reels require TEBAOFLEX aramid-reinforced Ladle Transfer Car High-Temperature Reeling Cable.

Does YGC22 steel-tape armoured silicone cable survive direct molten steel or slag splash?

YGC22 withstands +180 °C continuous ambient heat (+200 °C short peaks) and heavy mechanical crushing, but prolonged > +1,000 °C molten slag contact will char exposed silicone; for direct EAF or tundish splash zones, specify TF-PYRO-SM integral pyrojacketed cable.

What is the minimum order quantity and lead time for YGC, YGCR and YGC22 cables?

50 m per cross-section on 10 mm² through 185 mm² power sizes (100 m on 1.5 mm² to 6 mm² auxiliary sizes), custom-manufactured and 3,500 V AC tested in 7 to 45 working days.

Specifications

YGC, YGCR, YGCP & YGC22 Dimensional & Ampacity Schedule

YGC & YGC22 0.6/1 kV Voltage, Temperature & Drum Summary

  • Full 0.6/1 kV heavy feeder section: 3,500 V AC 5-minute dielectric withstand rating across 1.5 mm² to 185 mm² multi-core feeders where 300/500 V SiHF cables cannot carry motor load
  • Four metallurgical sub-models: Standard flexible YGC, Class 5 mobile festoon/bogie YGCR, tinned-copper EMC-screened YGCP for VFD drives, and steel-tape armoured YGC22 for trenches
  • Tear-resistant methyl-vinyl silicone: Heavy-wall silicone insulation and oxide-red tear-resistant silicone outer sheath remain elastic from -60 °C winter yards to +180 °C furnace galleries
  • Verified ampacity & geometry: Engineered to JB/T 8735 and IEC 60502-1 voltage geometry with transparent +100 °C hot-ambient current derating for melt-shop sizing
  • 50 m / 100 m EPC drum supply: Manufactured in 50 m minimum order cut lengths on >= 10 mm² power sections (100 m on <= 6 mm²) with 7 to 45 working days export delivery
YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C) technical data
ParameterValue
Rated voltage0.6/1 kV AC (600/1000 V, Um 1.2 kV) with 3500 V AC 5-minute routine dielectric withstand test
Conductor and core range1x4 mm2 to 1x185 mm2, 2C to 5C, 3+1C and 3+2C up to 3x185+1x95 mm2 and 4x185 mm2 in IEC 60228 bare or tinned copper
Series variantsYGC (standard heavy silicone), YGCR (Class 5 extra-flexible mobile), YGCP (tinned-copper EMC braid) and YGC22 (double galvanized steel-tape armoured)
Operating temperature and bend radius-60 C to +180 C continuous (+200 C short-term peak); minimum bend radius 6x OD (YGCR), 10x OD (YGC and YGCP) and 12x OD (YGC22)
Minimum order and lead time50 m per cross-section on 10 mm2 and above (100 m on 1.5 to 6 mm2), manufactured in 7 to 45 working days
Halogen-free and flame behaviourHalogen-free per IEC 60754-1 and flame-retardant per IEC 60332-1-2 with SiO2 ceramic ash retention
Insulation resistanceAt least 100 MOhm*km at +20 C and stable dielectric strength across continuous +180 C thermal cycling

YGC & YGCR 0.6/1 kV Unarmoured Flexible Silicone Power Cable Schedule

YGC & YGCR 0.6/1 kV Heavy-Duty Unarmoured Flexible Silicone Rubber Power Cable — Dimensional & Hot-Zone Ampacity Schedule
Model & Cross-SectionClass 5 YGCR Stranding (No. × Ø mm)Max. R at 20 °C (Ω/km)Nom. OD YGC / YGCR (mm)Ref. Current at +100 °C Air (A)Approx. Weight (kg/km)Drum MOQNext step
YGCR 1×6 mm²120 × 0.253.306.4 / 6.84684100 mRequest this size
YGCR 1×16 mm²320 × 0.251.219.0 / 9.68819850 mRequest this size
YGCR 1×35 mm²700 × 0.250.55412.2 / 12.814841250 mRequest this size
YGCR 1×70 mm²356 × 0.500.27216.6 / 17.523277550 mRequest this size
YGCR 1×120 mm²608 × 0.500.16121.0 / 22.23351,29550 mRequest this size
YGCR 3×2.5+1×1.5 mm²50 × 0.25 / 30 × 0.257.9812.4 / 13.022235100 mRequest this size
YGCR 3×4+1×2.5 mm²80 × 0.25 / 50 × 0.254.9514.4 / 15.230328100 mRequest this size
YGCR 3×6+1×4 mm²120 × 0.25 / 80 × 0.253.3016.2 / 17.439438100 mRequest this size
YGCR 3×10+1×6 mm²200 × 0.25 / 120 × 0.251.9120.2 / 21.65565550 mRequest this size
YGCR 3×16+1×10 mm²320 × 0.25 / 200 × 0.251.2123.0 / 24.67492550 mRequest this size
YGCR 3×25+1×16 mm²500 × 0.25 / 320 × 0.250.78027.2 / 29.0981,39050 mRequest this size
YGCR 3×35+1×16 mm²700 × 0.25 / 320 × 0.250.55431.4 / 33.21221,74050 mRequest this size
YGCR 3×50+1×25 mm²254 × 0.50 / 500 × 0.250.38635.8 / 37.81522,32050 mRequest this size
YGCR 3×95+1×50 mm²484 × 0.50 / 254 × 0.500.20646.0 / 48.52364,18050 mRequest this size
YGCR 4×16 mm²320 × 0.251.2124.2 / 25.87498550 mRequest this size
YGCR 4×50 mm²254 × 0.500.38638.2 / 40.41522,56050 mRequest this size

YGCP Screened & YGC22 Steel-Tape Armoured 0.6/1 kV Schedule

YGCP (EMC Copper-Braid Screened) & YGC22 (Double Steel-Tape Armoured) 0.6/1 kV Metallurgical Silicone Power Cable Schedule
Model & Cross-SectionShield / Armour LayerNom. OD (mm)Ref. Current at +100 °C Air (A)Min. Bend RadiusApprox. Weight (kg/km)Drum MOQNext step
YGCP 4×4 mm² (EMC Screened)>=80% Tinned Cu Braid15.83010× OD415100 mRequest this size
YGCP 4×10 mm² (EMC Screened)>=80% Tinned Cu Braid23.25510× OD79550 mRequest this size
YGCP 3×25+1×16 mm² (VFD)>=80% Tinned Cu Braid29.49810× OD1,56050 mRequest this size
YGCP 3×50+1×25 mm² (VFD)>=80% Tinned Cu Braid38.415210× OD2,58050 mRequest this size
YGC22 3×6+1×4 mm² (Armoured)Double Galv. Steel Tape18.23812× OD605100 mRequest this size
YGC22 3×16+1×10 mm² (Armoured)Double Galv. Steel Tape25.47212× OD1,25050 mRequest this size
YGC22 3×35+1×16 mm² (Armoured)Double Galv. Steel Tape34.811812× OD2,12050 mRequest this size
YGC22 3×50+1×25 mm² (Armoured)Double Galv. Steel Tape39.614812× OD2,79050 mRequest this size
YGC22 3×70+1×35 mm² (Armoured)Double Galv. Steel Tape44.218612× OD3,62050 mRequest this size
YGC22 3×95+1×50 mm² (Armoured)Double Galv. Steel Tape51.523012× OD4,76050 mRequest this size
YGC22 3×150+1×70 mm² (Armoured)Double Galv. Steel Tape60.430212× OD6,89050 mRequest this size
YGC22 3×185+1×95 mm² (Armoured)Double Galv. Steel Tape68.534812× OD8,42050 mRequest this size

Reference current values are calculated for a +180 °C maximum conductor temperature at +100 °C hot steel-mill ambient air (single circuit on perforated tray); at +60 °C ambient multiply by 1.32, and at +150 °C ambient multiply by 0.61. Final dimensions and derating are confirmed on the quotation drawing.

Additional core configurations including 2C, 3C, 5C (3+2C) and flat crane festoon YGCB / SiHF-FL profiles up to 240 mm² are manufactured to order.

ASCII part references for BOM and ERP entry: TF-YGC-3X16+1X10, TF-YGC-3X35+1X16, TF-YGCR-3X25+1X16, TF-YGCR-3X50+1X25, TF-YGCR-3X95+1X50, TF-YGCP-3X25+1X16, TF-YGC22-3X50+1X25, TF-YGC22-3X95+1X50, TF-YGC22-3X185+1X95.

Standards

YGC & YGCR Reference Standards (JB/T 8735 & IEC 60502-1)

YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C) standards and test references
Standard or specificationApplication
JB/T 8735 & GB/T 12706.1 / IEC 60502-1 Voltage Geometry0.6/1 kV insulation wall thickness, 3,500 V AC 5-minute dielectric withstand test and steel-tape armouring geometry.
IEC 60228 (GB/T 3956) Class 2 & Class 5Maximum 20 °C DC conductor resistance and fine-wire stranding geometry for bare and tinned annealed copper.
IEC 60332-1-2 & IEC 60754-1 / -2Single vertical flame propagation retardance and zero-halogen low-corrosivity combustion gas verification.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 3.5 kV routine dielectric test reports

IEC 60502-1 — Power cables with extruded insulation for rated voltages of 1 kV (Um = 1.2 kV)

IEC 60228 — Conductors of insulated cables (Class 2 and Class 5 copper)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.