YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)
YGC, extra-flexible YGCR, copper-braid-screened YGCP and double-steel-tape-armoured YGC22 (TF-YGC-YGCR-1KV) are 0.6/1 kV heavy-duty metallurgical silicone rubber power cables rated from -60 °C to +180 °C continuous (+200 °C short-term). Built with IEC 60228 Class 2 or Class 5 copper conductors from 1×4 mm² up to 4×185 mm² and 3×185+1×95 mm² for steelworks, EAF bays, coking plants and cement kilns.
YGC, extra-flexible YGCR, tinned-copper-screened YGCP and double-steel-tape-armoured YGC22 0.6/1 kV silicone rubber power cables deliver three-phase 380–690 V AC motor power across -60 °C to +180 °C metallurgical hot zones, spanning 1×4 mm² furnace leads up to 3×185+1×95 mm² and 4×185 mm² main feeders (outer diameters 6.2 mm to 72.0 mm).
Standard XLPE, EPR or polychloroprene power cables embrittle and crack within months along continuous-casting run-out tables, EAF transformer galleries, blast-furnace bustle pipes, rotary cement kilns and aluminum potlines, while European 300/500 V SiHF cables top out at light control cross-sections. Combining IEC 60228 copper conductors with thick-wall 0.6/1 kV silicone insulation, alkali-free E-glass thermal bedding and tear-modified silicone rubber outer sheathing preserves dielectric integrity and mechanical flexibility under cyclic thermal shock.
Specify Class 5 extra-flexible YGCR (6× OD minimum bend radius) for mobile transfer bogies, furnace doors and overhead C-track loops; specify YGCP (>= 80 % tinned-copper braid) for VFD-driven hot-gas fans and roller tables; specify YGC22 (helical galvanized steel-tape armour) for cable trenches, catwalks and crush-prone floors; or choose TF-PYRO-SM when direct +1,090 °C molten slag splash hits the cable route. Supplied from a 50 m minimum order quantity (100 m on <= 6 mm²) in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
YGC, YGCR, YGCP & YGC22 0.6/1 kV Silicone Construction
Constructed to 0.6/1 kV metallurgical power cable geometry (JB/T 8735 / GB/T 12706.1 reference and IEC 60228 conductor classes) for continuous +180 °C thermal endurance.

| Component | Material and construction |
|---|---|
| 1. Flexible Bare or Tinned Copper Conductors (IEC 60228) | Multi-wire stranded copper on fixed/semi-mobile YGC and YGC22, or extra-fine Class 5 rope-lay bare/tinned annealed copper (0.20–0.50 mm strands) on mobile YGCR and YGCP. |
| 2. 0.6/1 kV Extruded Silicone Rubber Core Insulation | High-dielectric methyl-vinyl silicone elastomer colour-coded or numbered for phase and protective-earth identification; forms protective non-conductive SiO2 ash under flame. |
| 3. E-Glass Thermal Bedding, Optional EMC Braid (YGCP) or Steel Tape Armour (YGC22) | Non-hygroscopic fiberglass fillers and binder tape; >= 80 % tinned-copper braid screen on YGCP, or double helical galvanized steel-tape armour over silicone inner sheath on YGC22. |
| 4. Heavy-Duty Tear-Resistant Silicone Rubber Outer Sheath | Vulcanized brick-red / oxide-red (or black) tear-propagating-resistant silicone rubber jacket resisting +180 °C radiant heat, ozone, UV and industrial furnace fumes. |
YGC, YGCR, YGCP & YGC22 Type Designation Breakdown
- Y: Mobile / heavy-duty industrial power cable series
- G + C: Silicone rubber core insulation (G) + heavy-duty tear-resistant silicone outer sheath (C)
- R (in YGCR): Extra-flexible IEC 60228 Class 5 fine-stranded copper conductor for mobile festoon and trolley duty
- P (in YGCP): Tinned-copper wire braid electromagnetic screen (>= 80 % optical coverage) for VFD motor feeders
- 22 (in YGC22): Double helical galvanized steel-tape armour with outer silicone protective oversheath
YGC & YGC22 Steelworks, EAF Bay & Rotary Kiln Feeder Duty
Engineered for 380 V / 400 V / 480 V / 690 V AC three-phase power feeders in metallurgical, glass, cement, coking and power-generation plants.

- Electric arc furnace (EAF) roof-swing auxiliaries, ladle-refining bay blowers, continuous-casting run-out roller tables and billet reheat furnace pushers.
- Coking-plant pusher/quenching car fixed catwalks, blast-furnace hot-blast stove valve actuators, sinter cooler fans and pelletizing induration grates.
- Rotary cement kiln shell blowers, clinker cooler drives, float-glass annealing lehr circulation motors and aluminum smelter anode baking furnaces.
- Overseas EPC steelworks and non-ferrous smelter projects specifying Chinese/IEC BOM codes YGC, YGCR, YGCP, YGC22, JGGF or JGGR.
YGC / YGC22 (0.6/1 kV) vs SiHF vs FEP-GSWB vs Reeling Cable
| Cable Family | Voltage & Section Span | Protection & Duty Envelope | When to Specify |
|---|---|---|---|
| YGC / YGCR / YGCP / YGC22 (this page) | 0.6/1 kV; 1.5–185 mm² (1–5C) | -60 to +180 °C heavy silicone; optional EMC braid or steel-tape armour | Main 380–690 V hot-zone motor feeders, furnace trays, trenches & festoons |
| SiHF / SiHF-J & SiHF-P | 300/500 V; 0.75–16 mm² | -60 to +180 °C EN 50525-2-83 light silicone (unarmoured or GSWB) | European 230/400 V light auxiliary drives, heaters and luminaire drops |
| FEP/PFA-GSWB / PFA-SSWB | 0.6/1 kV; 1.5–35 mm² | -60 to +260 °C fluoropolymer + steel wire braid | Hot ester hydraulic oil, acid pickling tanks or >+180 °C chemical splash |
| Ladle Transfer Car Reeling Cable | 0.6/1 kV; 4–95 mm² | Aramid anti-torsion braid + high-tension motorized drum reeling sheath | Constant spring/motorized drum reeling on floor ladle transfer bogies |
Do not install standard YGC or YGCR on high-tension motorized cable reels; specify dedicated aramid-reinforced Ladle Transfer Car Reeling Cable for continuous drum winding.
YGC, YGCR, YGCP & YGC22 Silicone Power Cable RFQ Checklist
- Exact model code (YGC fixed, YGCR Class 5 mobile, YGCP copper-screened, or YGC22 steel-tape armoured) and core × mm² size.
- Conductor finish preference: bare copper (standard) or tinned copper (recommended for sulfurous coking/pickling atmospheres).
- Installation mode (fixed tray/trench, C-track festoon, or short flexible machine loop) and maximum ambient radiant temperature (°C).
- Total meterage and individual drum cut lengths (MOQ 50 m on >= 10 mm², 100 m on <= 6 mm²; 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Silicone, Mica & Metallurgical Cables
- Pair with KGG, KGGR, KGGP & KGG22 450/750 V Silicone Control Cable
- Upgrade to TF-PYRO-SM +1,090 °C Slag-Splash Pyrojacketed EAF Cable
- Compare Ladle Transfer Car 0.6/1 kV Drum Reeling Cable
- Compare FEP/PFA-GSWB 0.6/1 kV Oil & Acid-Resistant High-Temp Power Cable
- Engineering guide: High-temperature cable insulation & conductor limits
YGC, YGCR, YGCP & YGC22 Silicone Power Cable FAQ
What is the difference between YGC, YGCR, YGCP and YGC22 silicone power cables?
YGC uses standard flexible stranded copper for fixed hot-zone trays and short machine drops; YGCR upgrades to extra-fine IEC 60228 Class 5 copper (6× OD bend radius) for mobile trolleys and furnace doors; YGCP adds an >= 80 % tinned-copper EMC braid for VFD motor drives; and YGC22 adds double galvanized steel-tape armour for crush and rodent protection in trenches.
When do I need 0.6/1 kV YGC / YGCR instead of 300/500 V SiHF silicone cable?
Specify 0.6/1 kV YGC or YGCR whenever supplying three-phase 380–690 V AC industrial motors above 4–10 kW, long melt-shop feeder runs from 16 mm² to 185 mm², or circuits requiring a 3,500 V AC 5-minute dielectric test where 300/500 V SiHF insulation walls are under-rated.
Can YGC or YGCR be used on motorized steel-mill ladle transfer car cable drums?
No — standard silicone rubber sheaths tear under continuous high-tension drum reeling and guide-roller torsion; YGCR suits C-track festoons and free-hanging loops, whereas motorized ladle car reels require TEBAOFLEX aramid-reinforced Ladle Transfer Car High-Temperature Reeling Cable.
Does YGC22 steel-tape armoured silicone cable survive direct molten steel or slag splash?
YGC22 withstands +180 °C continuous ambient heat (+200 °C short peaks) and heavy mechanical crushing, but prolonged > +1,000 °C molten slag contact will char exposed silicone; for direct EAF or tundish splash zones, specify TF-PYRO-SM integral pyrojacketed cable.
What is the minimum order quantity and lead time for YGC, YGCR and YGC22 cables?
50 m per cross-section on 10 mm² through 185 mm² power sizes (100 m on 1.5 mm² to 6 mm² auxiliary sizes), custom-manufactured and 3,500 V AC tested in 7 to 45 working days.
YGC, YGCR, YGCP & YGC22 Dimensional & Ampacity Schedule
YGC & YGC22 0.6/1 kV Voltage, Temperature & Drum Summary
- Full 0.6/1 kV heavy feeder section: 3,500 V AC 5-minute dielectric withstand rating across 1.5 mm² to 185 mm² multi-core feeders where 300/500 V SiHF cables cannot carry motor load
- Four metallurgical sub-models: Standard flexible YGC, Class 5 mobile festoon/bogie YGCR, tinned-copper EMC-screened YGCP for VFD drives, and steel-tape armoured YGC22 for trenches
- Tear-resistant methyl-vinyl silicone: Heavy-wall silicone insulation and oxide-red tear-resistant silicone outer sheath remain elastic from -60 °C winter yards to +180 °C furnace galleries
- Verified ampacity & geometry: Engineered to JB/T 8735 and IEC 60502-1 voltage geometry with transparent +100 °C hot-ambient current derating for melt-shop sizing
- 50 m / 100 m EPC drum supply: Manufactured in 50 m minimum order cut lengths on >= 10 mm² power sections (100 m on <= 6 mm²) with 7 to 45 working days export delivery
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (600/1000 V, Um 1.2 kV) with 3500 V AC 5-minute routine dielectric withstand test |
| Conductor and core range | 1x4 mm2 to 1x185 mm2, 2C to 5C, 3+1C and 3+2C up to 3x185+1x95 mm2 and 4x185 mm2 in IEC 60228 bare or tinned copper |
| Series variants | YGC (standard heavy silicone), YGCR (Class 5 extra-flexible mobile), YGCP (tinned-copper EMC braid) and YGC22 (double galvanized steel-tape armoured) |
| Operating temperature and bend radius | -60 C to +180 C continuous (+200 C short-term peak); minimum bend radius 6x OD (YGCR), 10x OD (YGC and YGCP) and 12x OD (YGC22) |
| Minimum order and lead time | 50 m per cross-section on 10 mm2 and above (100 m on 1.5 to 6 mm2), manufactured in 7 to 45 working days |
| Halogen-free and flame behaviour | Halogen-free per IEC 60754-1 and flame-retardant per IEC 60332-1-2 with SiO2 ceramic ash retention |
| Insulation resistance | At least 100 MOhm*km at +20 C and stable dielectric strength across continuous +180 C thermal cycling |
YGC & YGCR 0.6/1 kV Unarmoured Flexible Silicone Power Cable Schedule
| Model & Cross-Section | Class 5 YGCR Stranding (No. × Ø mm) | Max. R at 20 °C (Ω/km) | Nom. OD YGC / YGCR (mm) | Ref. Current at +100 °C Air (A) | Approx. Weight (kg/km) | Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| YGCR 1×6 mm² | 120 × 0.25 | 3.30 | 6.4 / 6.8 | 46 | 84 | 100 m | Request this size |
| YGCR 1×16 mm² | 320 × 0.25 | 1.21 | 9.0 / 9.6 | 88 | 198 | 50 m | Request this size |
| YGCR 1×35 mm² | 700 × 0.25 | 0.554 | 12.2 / 12.8 | 148 | 412 | 50 m | Request this size |
| YGCR 1×70 mm² | 356 × 0.50 | 0.272 | 16.6 / 17.5 | 232 | 775 | 50 m | Request this size |
| YGCR 1×120 mm² | 608 × 0.50 | 0.161 | 21.0 / 22.2 | 335 | 1,295 | 50 m | Request this size |
| YGCR 3×2.5+1×1.5 mm² | 50 × 0.25 / 30 × 0.25 | 7.98 | 12.4 / 13.0 | 22 | 235 | 100 m | Request this size |
| YGCR 3×4+1×2.5 mm² | 80 × 0.25 / 50 × 0.25 | 4.95 | 14.4 / 15.2 | 30 | 328 | 100 m | Request this size |
| YGCR 3×6+1×4 mm² | 120 × 0.25 / 80 × 0.25 | 3.30 | 16.2 / 17.4 | 39 | 438 | 100 m | Request this size |
| YGCR 3×10+1×6 mm² | 200 × 0.25 / 120 × 0.25 | 1.91 | 20.2 / 21.6 | 55 | 655 | 50 m | Request this size |
| YGCR 3×16+1×10 mm² | 320 × 0.25 / 200 × 0.25 | 1.21 | 23.0 / 24.6 | 74 | 925 | 50 m | Request this size |
| YGCR 3×25+1×16 mm² | 500 × 0.25 / 320 × 0.25 | 0.780 | 27.2 / 29.0 | 98 | 1,390 | 50 m | Request this size |
| YGCR 3×35+1×16 mm² | 700 × 0.25 / 320 × 0.25 | 0.554 | 31.4 / 33.2 | 122 | 1,740 | 50 m | Request this size |
| YGCR 3×50+1×25 mm² | 254 × 0.50 / 500 × 0.25 | 0.386 | 35.8 / 37.8 | 152 | 2,320 | 50 m | Request this size |
| YGCR 3×95+1×50 mm² | 484 × 0.50 / 254 × 0.50 | 0.206 | 46.0 / 48.5 | 236 | 4,180 | 50 m | Request this size |
| YGCR 4×16 mm² | 320 × 0.25 | 1.21 | 24.2 / 25.8 | 74 | 985 | 50 m | Request this size |
| YGCR 4×50 mm² | 254 × 0.50 | 0.386 | 38.2 / 40.4 | 152 | 2,560 | 50 m | Request this size |
YGCP Screened & YGC22 Steel-Tape Armoured 0.6/1 kV Schedule
| Model & Cross-Section | Shield / Armour Layer | Nom. OD (mm) | Ref. Current at +100 °C Air (A) | Min. Bend Radius | Approx. Weight (kg/km) | Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| YGCP 4×4 mm² (EMC Screened) | >=80% Tinned Cu Braid | 15.8 | 30 | 10× OD | 415 | 100 m | Request this size |
| YGCP 4×10 mm² (EMC Screened) | >=80% Tinned Cu Braid | 23.2 | 55 | 10× OD | 795 | 50 m | Request this size |
| YGCP 3×25+1×16 mm² (VFD) | >=80% Tinned Cu Braid | 29.4 | 98 | 10× OD | 1,560 | 50 m | Request this size |
| YGCP 3×50+1×25 mm² (VFD) | >=80% Tinned Cu Braid | 38.4 | 152 | 10× OD | 2,580 | 50 m | Request this size |
| YGC22 3×6+1×4 mm² (Armoured) | Double Galv. Steel Tape | 18.2 | 38 | 12× OD | 605 | 100 m | Request this size |
| YGC22 3×16+1×10 mm² (Armoured) | Double Galv. Steel Tape | 25.4 | 72 | 12× OD | 1,250 | 50 m | Request this size |
| YGC22 3×35+1×16 mm² (Armoured) | Double Galv. Steel Tape | 34.8 | 118 | 12× OD | 2,120 | 50 m | Request this size |
| YGC22 3×50+1×25 mm² (Armoured) | Double Galv. Steel Tape | 39.6 | 148 | 12× OD | 2,790 | 50 m | Request this size |
| YGC22 3×70+1×35 mm² (Armoured) | Double Galv. Steel Tape | 44.2 | 186 | 12× OD | 3,620 | 50 m | Request this size |
| YGC22 3×95+1×50 mm² (Armoured) | Double Galv. Steel Tape | 51.5 | 230 | 12× OD | 4,760 | 50 m | Request this size |
| YGC22 3×150+1×70 mm² (Armoured) | Double Galv. Steel Tape | 60.4 | 302 | 12× OD | 6,890 | 50 m | Request this size |
| YGC22 3×185+1×95 mm² (Armoured) | Double Galv. Steel Tape | 68.5 | 348 | 12× OD | 8,420 | 50 m | Request this size |
Reference current values are calculated for a +180 °C maximum conductor temperature at +100 °C hot steel-mill ambient air (single circuit on perforated tray); at +60 °C ambient multiply by 1.32, and at +150 °C ambient multiply by 0.61. Final dimensions and derating are confirmed on the quotation drawing.
Additional core configurations including 2C, 3C, 5C (3+2C) and flat crane festoon YGCB / SiHF-FL profiles up to 240 mm² are manufactured to order.
ASCII part references for BOM and ERP entry: TF-YGC-3X16+1X10, TF-YGC-3X35+1X16, TF-YGCR-3X25+1X16, TF-YGCR-3X50+1X25, TF-YGCR-3X95+1X50, TF-YGCP-3X25+1X16, TF-YGC22-3X50+1X25, TF-YGC22-3X95+1X50, TF-YGC22-3X185+1X95.
YGC & YGCR Reference Standards (JB/T 8735 & IEC 60502-1)
| Standard or specification | Application |
|---|---|
| JB/T 8735 & GB/T 12706.1 / IEC 60502-1 Voltage Geometry | 0.6/1 kV insulation wall thickness, 3,500 V AC 5-minute dielectric withstand test and steel-tape armouring geometry. |
| IEC 60228 (GB/T 3956) Class 2 & Class 5 | Maximum 20 °C DC conductor resistance and fine-wire stranding geometry for bare and tinned annealed copper. |
| IEC 60332-1-2 & IEC 60754-1 / -2 | Single vertical flame propagation retardance and zero-halogen low-corrosivity combustion gas verification. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 3.5 kV routine dielectric test reports
IEC 60502-1 — Power cables with extruded insulation for rated voltages of 1 kV (Um = 1.2 kV)
IEC 60228 — Conductors of insulated cables (Class 2 and Class 5 copper)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
KGG, KGGR, KGGP, KGGRP & KGG22/KGG32 450/750 V Silicone Rubber Control & Armoured Cable
A related cable option for a different application or duty profile.
View productTF-PYRO-SM 0.6/1 kV Slag-Splash Protected Pyrojacketed EAF & Steel-Mill Power/Control Cable (+260 / +1,090 °C)
A related cable option for a different application or duty profile.
View productLadle Transfer Car & Steel Mill High-Temperature Reeling Cable (0.6/1 kV)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.