Case 24 · Port Klang, Malaysia · Harbor & Container Crane · PUR-C-HF 0.6/1 kV Screened Cable

PUR-C-HF 0.6/1 kV 1×10 mm² Halogen-Free Screened Polyurethane Crane Cable for Port Klang, Malaysia

Port crane machinery at Port Klang on Malaysia’s Strait of Malacca operates continuously in salt-laden maritime humidity, equatorial UV, hydraulic oil mist and electromagnetic interference from variable-frequency hoist and trolley drives. For a multi-drum crane electrification order destined for Port Klang, TEBAOFLEX manufactured and container-shipped 0.6/1 kV PUR-C-HF 1 × 10 mm² halogen-free screened polyurethane crane cable—combining an IEC 60228 Class 5 flexible copper core, dual-layer PUR insulation and inner bedding, a corrosion-resistant tinned-copper wire braid screen and a 9.91 mm matte black PUR-HF outer jacket.

Angled studio sample of TEBAOFLEX PUR-C-HF 0.6/1 kV 1×10 mm² halogen-free tinned-copper braided screened polyurethane crane cable manufactured for Port Klang, Malaysia
Finished factory sample of TEBAOFLEX PUR-C-HF 0.6/1 kV 1×10 mm² crane cable supplied for Port Klang, Malaysia: Class 5 flexible copper conductor, halogen-free PUR core insulation, inner PUR bedding, tinned-copper EMC braid and black PUR-HF outer sheath.

Project at a glance

This Malaysian port crane supply delivered TEBAOFLEX PUR-C-HF 0.6/1 kV 1 × 10 mm² halogen-free tinned-copper braided polyurethane cable at 9.91 mm nominal outside diameter and 191.4 kg/km mass, routine-tested at 3.5 kV AC for 5 minutes and packed on IPPC heat-treated enclosed wooden export drums.

Summary of the Port Klang, Malaysia PUR-C-HF 0.6/1 kV 1×10 mm² screened crane cable order
Order itemVerified engineering detail
Destination & applicationPort Klang, Malaysia — moving port crane festoon, trolley auxiliary power, inverter jumper and low-impedance EMC bonding service
Cable designationTEBAOFLEX PUR-C-HF 1 × 10 mm², U0/U = 0.6/1 kV (0.7/1.2 kV max AC; 0.9/1.8 kV DC)
Conductor (IEC 60228 Class 5)10 mm² finely stranded flexible plain copper · max DC resistance ≤ 1.91 Ω/km at 20 °C (1.83 Ω/km IEC reference)
Insulation & inner beddingHalogen-free PUR primary insulation (≥ 20 MΩ·km at 20 °C) + polyester slip tape + extruded halogen-free PUR inner protection layer
EMC screen & outer sheathConcentric tinned-copper wire braid (~85 % coverage) + matte black halogen-free flame-retardant PUR outer sheath (IEC 60332-1-2)
Dimensions & weight9.91 mm nominal outside diameter · 87.3 kg/km copper index · 191.4 kg/km total cable weight
Ampacity, bend & tensile limitsApprox. 45 A at 30 °C free air (~40 A at 40 °C tropical port ambient); 6 × D (59 mm) fixed / 8 × D (79 mm) mobile bend; 15 N/mm² (150 N) max pull
Sheath marking & dispatchTEBAOFLEX CABLE 600/1000V FESTOON PUR-C-HF 1×10mm² IEC Standard + metre mark; container-loaded on IPPC lagged wooden drums
Scope note. This case record documents the six-layer PUR-C-HF single-core screened construction, tropical port ampacity and bending parameters, sheath marking verification and multi-drum sea container loading for Port Klang. Terminal operator, crane contractor identity and commercial pricing remain confidential.

Why do Port Klang crane trolleys specify halogen-free screened PUR-C-HF 1×10 mm²?

Quay and yard cranes at Port Klang combine constant trolley vibration, salt-mist humidity, gearbox oil splash and high-frequency switching noise from crane VFDs. Dual-wall halogen-free polyurethane with an inner-bedded tinned-copper braid prevents jacket hydrolysis, braid fretting and EMI coupling in a compact 9.91 mm profile.

On container and bulk-handling cranes—mapped zone by zone on our port container crane cable solutions hub—single-core 10 mm² screened flexible leads serve dedicated moving functions alongside main multi-core festoon bundles: high-frequency equipotential earthing straps across articulated trolley hinges, DC brake/magnet auxiliary feeds, and compact single-phase or grouped inverter jumpers where bend radius inside junction boxes is tight.

Standard PVC single-core panel wire (H07V-K) hardens rapidly under equatorial UV and cracks when cycled across festoon loops, while unscreened rubber single cores radiate high-frequency switching transients into nearby encoder and PROFIBUS/fibre crane trunks. Building the Port Klang order to our Festoonflex PUR-HF / PUR-C-HF 0.6/1 kV crane cable specification addressed three coastal crane failure mechanisms:

  • Hydrolysis, oil and abrasion immunity: Cross-linked/elastomeric polyether-grade PUR resists tropical salt-fog hydrolysis, hydraulic oil swelling and steel saddle chafing far longer than PVC or standard nitrile blends, while meeting halogen-free flame retardance under IEC 60332-1-2.
  • Inner PUR bedding beneath tinned-copper braid: Instead of braiding copper wires directly onto the 10 mm² core insulation, an extruded inner PUR cushion over polyester tape prevents metallic braid strands from sawing into the primary dielectric at 8 × D (79 mm) dynamic bending radius.
  • Salt-fog-resistant tinned-copper EMC screen: Tin-plated copper braid strands resist black marine sulfide/chloride corrosion in Malaysian coastal air and compress cleanly inside 360-degree EMC brass cable glands (see our double-screened VFD and 360-degree EMC cable termination guide).
Schematic cross-section of TEBAOFLEX PUR-C-HF 0.6/1 kV 1×10 mm² halogen-free screened polyurethane crane cable123456
  1. Conductor: 1 × 10 mm² finely stranded flexible plain copper per IEC 60228 Class 5 (≤ 1.91 Ω/km max DC resistance at 20 °C)
  2. Core insulation: halogen-free cross-linked/elastomeric polyurethane (PUR-HF) compound (≥ 20 MΩ·km at 20 °C; 3.5 kV AC / 5 min test)
  3. Wrapping separator: non-hygroscopic polyester tape decoupling core slip during repetitive festoon and trolley flexing
  4. Inner protection bedding: extruded halogen-free PUR inner sheath cushioning the core beneath the metallic braid
  5. EMC & fault screen (-C-): concentric tinned-copper wire braid (~85 % optical coverage) resisting salt-mist oxidation
  6. Outer sheath (-HF): matte black halogen-free flame-retardant polyurethane (IEC 60332-1-2), 9.91 mm nominal OD, 191.4 kg/km
Six-layer concentric structure of the TEBAOFLEX PUR-C-HF 0.6/1 kV 1×10 mm² screened crane cable supplied to Port Klang, Malaysia (not to scale).
End-face view of PUR-C-HF 0.6/1 kV 1×10 mm² showing IEC 60228 Class 5 flexible plain copper conductor, halogen-free PUR insulation, inner PUR bedding, tinned-copper EMC braid and black PUR-HF outer sheath
End-face cross-section of the finished PUR-C-HF 1×10 mm² cable showing the Class 5 plain copper core, inner PUR layers, concentric tinned-copper wire braid and matte black PUR-HF jacket.
Quality inspector holding the 9.91 mm nominal OD cut end of TEBAOFLEX PUR-C-HF 1×10 mm² to verify concentric tinned-copper wire braid coverage and wall concentricity
Pre-shipment cut-end check confirming concentricity and compact 9.91 mm outside diameter for tight crane gland plates and festoon clamps.

PUR-C-HF 1×10 mm² electrical, thermal and mechanical specification table

Designed around IEC 60228 Class 5 stranding and IEC 60502-1 0.6/1 kV voltage coordination, PUR-C-HF 1×10 mm² pairs ≤ 1.91 Ω/km DC resistance and 3.5 kV AC / 5 min dielectric testing with a −40 °C to +80 °C operating window and 150 N maximum conductor pull.

Electrical, dimensional and dynamic mechanical schedule for TEBAOFLEX PUR-C-HF 0.6/1 kV 1×10 mm²
ParameterPUR-C-HF 1 × 10 mm² verified valueStandard / crane engineering note
Rated / max operating voltageU0/U = 0.6/1 kV (0.7/1.2 kV AC max · 0.9/1.8 kV DC)IEC 60502-1 low-voltage crane feeder & inverter auxiliary coordination
Routine AC dielectric test3,500 V AC for 5 minutesApplied core-to-screen on every production drum without breakdown
Conductor DC resistance (20 °C)≤ 1.91 Ω/km project max (1.83 Ω/km IEC 60228 ref.)IEC 60228 Class 5 flexible plain copper, 87.3 kg/km copper index
Insulation resistance (20 °C)≥ 20 MΩ·kmHalogen-free PUR primary dielectric
Nominal OD & total mass9.91 mm · 191.4 kg/kmLightweight load on high-speed festoon trolleys and spreader umbilical brackets
Continuous current rating~45 A at 30 °C air · ~40 A at 40 °C Port Klang ambient90 °C max conductor temperature; 250 °C 5 s short-circuit ceiling
Operating temperature range−40 °C to +80 °C (fixed & flexing)Stable across refrigerated cold-chain container yards and tropical crane booms
Minimum bending radius & pull6 × D (~59 mm) fixed · 8 × D (~79 mm) dynamic · 150 N pull15 N/mm² maximum dynamic tensile load on 10 mm² copper cross-section

When to choose round single-core PUR-C-HF vs flat rubber festoon or vertical spreader cables: Round single-core PUR-C-HF 0.6/1 kV cable fits individual circular EMC compression glands, articulated trolley hinge loops and contoured round festoon clips (IEC 60228 / IEC 60502-1 basis). When a crane boom requires multi-core flat loops clamped in rectangular C-rail or I-beam saddles—such as our Ho Chi Minh Port NGFLGÖU-J 3×50+1×16 mm² flat festoon project—select (N)GFLCGÖU screened flat rubber festoon cable instead; for gravity-fed twin-lift spreader baskets subject to ±50°/m torsion, step up to D12YST11YU11Y-JZ PUR vertical spreader cable. Full profile boundaries are mapped in our flat cable vs round cable for cranes selection guide and crane festoon system sizing guide.

Extrusion-line sheath print, IPPC enclosed wooden drums and container loading

Every metre of the black PUR-HF outer sheath was marked TEBAOFLEX CABLE 600/1000V FESTOON PUR-C-HF 1×10mm² IEC Standard with sequential metre counters, spooled onto IPPC heat-treated wooden drums enclosed in full wooden battens, and stacked two-high on fumigated pallets inside the sea container for Port Klang.

TEBAOFLEX CABLE 600/1000V FESTOON PUR-C-HF 1×10mm² IEC Standard 0307M

White extrusion-line marking on matte black PUR-HF jacket reading TEBAOFLEX CABLE 600/1000V FESTOON PUR-C-HF 1x10mm² IEC Standard 0307M
In-line white ink marking on the matte black halogen-free PUR jacket confirming 600/1000 V rating, FESTOON PUR-C-HF 1×10 mm² designation and sequential 0307M metre counter.
Stacked IPPC heat-treated lagged wooden export drums strapped on fumigated pallets prior to container stuffing for Port Klang, Malaysia
Batch of completed PUR-C-HF 0.6/1 kV crane cable drums fully enclosed in protective wooden battens and green PET strapping on IPPC heat-treated pallets.
Lagged wooden export drums of TEBAOFLEX PUR-C-HF 0.6/1 kV crane cable stacked and secured inside a sea container for shipment to Port Klang, Malaysia
Multi-drum ocean container stuffing at dispatch: palletized wooden export drums stacked and braced for sea transit to Port Klang, Malaysia.

What to specify when ordering PUR-C-HF screened crane and festoon cables

Providing core count and mm² cross-section, crane subsystem (festoon loop, trolley jumper, energy chain or reel), EMC gland clamping range, travel speed and cut drum lengths lets our engineering team confirm exact outer diameter and tropical ampacity before production.

Include these crane cable details with your inquiry for pre-quotation review:
  • Core configuration: single-core (e.g. 1×10 mm² to 1×240 mm²) or multi-core power/control (e.g. 4G2.5 to 4G95, 12G1.5 to 36G2.5) with or without -C- tinned-copper braid
  • Crane mechanism: C-rail/I-beam festoon trolley, drag chain / e-chain, articulated boom hinge jumper or motorized drum
  • Operating voltage, inverter PWM switching duty, port ambient temperature (e.g. 40 °C tropical derating) and EMC cable gland entry bore
  • Halogen-free flame-retardant (IEC 60332-1-2), low-smoke, oil-immersion or seawater-splash requirements
  • Exact continuous cut length per wooden drum (from 50 m MOQ), custom sheath legend and destination port customs rules

As of November 2026, TEBAOFLEX manufactures custom PUR-HF, PUR-C-HF, NGFLGÖU and (N)SHTÖU crane cables at our Taicang factory from a 50 m minimum order quantity, with a standard production lead time of 7 to 45 working days depending on core schedule and order volume. Browse all port electrification families in our port, crane and festoon cables catalogue.

Request a PUR-C-HF screened crane cable quote & datasheet →

Frequently asked questions on PUR-C-HF 0.6/1 kV 1×10 mm² crane cables

What does PUR-C-HF 0.6/1 kV 1×10 mm² designate on a port crane cable?

In European crane and festoon nomenclature, PUR identifies an abrasion-, oil- and hydrolysis-resistant polyurethane insulation and sheath system, -C- denotes a concentric tinned-copper wire braid electromagnetic screen over an inner bedding, and -HF confirms a halogen-free flame-retardant compound (IEC 60332-1-2). The 0.6/1 kV 1×10 mm² build delivers a compact 9.91 mm outside diameter at 191.4 kg/km for single-core screened power, DC auxiliary, VFD jumper or low-inductance crane bonding circuits.

Why did Port Klang crane duty call for a polyurethane (PUR-HF) outer sheath instead of PVC or standard polychloroprene?

Port Klang on the Strait of Malacca combines year-round 32 °C to 38 °C maritime heat, high relative humidity, salt spray, intense equatorial UV and gearbox grease on crane trolley girders. Thermoplastic PVC plasticizers migrate and crack under continuous flexing, while standard rubber runs heavier and larger in diameter; halogen-free PUR resists seawater hydrolysis, UVchalking and mechanical trolley-guide chafing at 6 × D fixed (59 mm) and 8 × D dynamic (79 mm) bend radii.

Why is an inner PUR bedding placed underneath the tinned-copper braid screen on PUR-C-HF 1×10 mm²?

Wrapping a metallic copper braid directly over thin primary insulation on a continuously flexing crane cable allows braid cross-overs to fret into the dielectric wall. Extruding a dedicated halogen-free PUR inner protection layer over a polyester slip tape cushions the 10 mm² core, locks braid circularity for 360-degree EMC cable glands and preserves the 3.5 kV AC / 5 min dielectric margin across millions of trolley cycles.

How much current can PUR-C-HF 1×10 mm² carry in tropical Malaysian port ambient temperatures?

At the 30 °C free-air reference with a 90 °C maximum conductor temperature (250 °C short-circuit ceiling), PUR-C-HF 1×10 mm² carries approximately 45 A. Applying a 0.88 ambient correction factor for 40 °C shaded crane-girder air at Port Klang yields approximately 40 A continuous free-air capacity prior to multi-cable festoon bundle grouping factors.

What minimum order quantity and drum packing apply to custom PUR-C-HF crane cables?

As of November 2026, TEBAOFLEX manufactures custom single-core and multi-core PUR-HF and PUR-C-HF 0.6/1 kV crane cables from a 50 m minimum order quantity (MOQ), with standard production lead times of 7 to 45 working days. Export orders ship on IPPC heat-treated fully lagged wooden drums chocked inside sea containers.