TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Extra-Flexible Silicone High-Current Switchgear Cable (2.5–300 mm²)
TF-SIHC (TF-SIHC-183 1.8/3 kV and TF-SIHC-366 3.6/6 kV) is a halogen-free, self-extinguishing double-insulated extra-flexible silicone high-current cable spanning 2.5 mm² to 300 mm² with 0.07 mm / 0.10 mm super-fine annealed Cu-ETP1 copper stranding (DIN EN 13602). Engineered for -50 °C to +180 °C switchgear cabinets, traction converters and transformers, supplied as bulk reel (MOQ 50 m) or pre-terminated jumpers with pressed seamless copper sleeves (MOQ 10 pcs).
TF-SIHC 1.8/3 kV (TF-SIHC-183) and 3.6/6 kV (TF-SIHC-366) double-insulated extra-flexible silicone high-current cables (2.5 mm² to 300 mm², -50 °C to +180 °C continuous, 10 kV AC spark tested) provide compact, short-circuit-proof air-cooled power interconnections inside medium-voltage switchboards, traction converters, dry-type transformers and industrial rectifier cabinets.
Conventional 1.8/3 kV rubber cables such as NSGAFÖU cap out at +90 °C with Class 5 stranding that resists tight cubicle bends, whereas standard 300/500 V SiF single-wall silicone wire lacks the dielectric thickness and mechanical sheath durability required for 3 kV and 6 kV systems. TF-SIHC pairs ultra-fine 0.07 mm (2.5–16 mm²) and 0.10 mm (25–300 mm²) annealed Cu-ETP1 copper ropes with two extruded layers of ~60 Shore A halogen-free, ozone- and UV-resistant silicone rubber—allowing tight 4× OD fixed routing and solderless high-compression crimping into seamless copper contact sleeves or narrow-flange tubular lugs.
Specify TF-SIHC-183 (1.8/3 kV) or TF-SIHC-366 (3.6/6 kV) for high-temperature European IEC switchgear, railway rolling-stock converters and compact busbar jumpers; choose NSGAFÖU / NSHXAFÖ where standard +90 °C EPR rubber suffices, or TF-ACHC for low-voltage 70–1,000 mm² bare/pyrojacketed furnace jumpers. Bulk MOQ 50 m (>=10 mm²) / 100 m (<=6 mm²), or 10 pcs for pre-terminated jumpers, in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Silicone Construction
Engineered to DIN EN 13602 conductor purity and IEC 60332 / EN 45545 halogen-free flame-retardancy criteria; also built to UL Style 30119 dimensional design (note: UL Listing is not claimed for this product).

| Component | Material and construction |
|---|---|
| 1. Super-Fine Soft-Annealed Cu-ETP1 Copper Conductor (DIN EN 13602) | Uncoated (or optional tinned) ultra-fine stranded ropes using 0.07 mm single wires (2.5–16 mm²) and 0.10 mm single wires (25–300 mm²) for effortless tight-radius switchgear routing. |
| 2. Inner Primary Halogen-Free Silicone Insulation | Extruded high-dielectric cross-linked silicone rubber (~20 kV/mm dielectric strength, contrast natural/white color for instant nick/wear inspection during stripping). |
| 3. Outer Protective Self-Extinguishing Silicone Sheath | Tough ~60 Shore A halogen-free silicone jacket (reddish-brown, black or custom color) resistant to -50 °C cold flex, +180 °C continuous heat (+220 °C peak), ozone, UV and condensation. |
| 4. Optional Tinned-Copper EMC Braid & Pressed Contact Terminations | Optional braided copper screen for VFD/converter EMC suppression, plus optional factory-pressed seamless Cu-ETP contact sleeves (1-to-4-layer stacks), DIN 46234 lugs or narrow-flange tubular lugs with silicone transition sleeves. |
TF-SIHC Voltage, Screen & Termination Code Breakdown
- TF-SIHC-183: 1.8/3 kV AC double-insulated extra-flexible halogen-free silicone high-current cable (2.5–300 mm²)
- TF-SIHC-366: 3.6/6 kV AC double-insulated extra-flexible halogen-free silicone high-current cable (2.5–300 mm²)
- -C: Optional tinned-copper braided EMC screen under an outer silicone sheath for traction/VFD bays
- -SL / -TL: Pre-terminated jumper options: Pressed Seamless Copper Contact Sleeve (-SL) or Narrow-Flange Tubular Lug (-TL)
- -2L / -3L / -4L: Multi-layer parallel pre-terminated silicone jumper stack (2, 3 or 4 parallel cables pressed into one contact head)
TF-SIHC MV Switchgear, Traction Converter & Transformer Duty
Designed for compact high-current air-cooled connections where high voltage, extreme ambient heat, tight bending clearances and halogen-free fire safety converge.

- Medium-voltage 1.8/3 kV and 3.6/6 kV industrial switchgear cubicles, breaker trucks and transformer secondary taps.
- Railway rolling-stock traction inverters, auxiliary converters and roof-to-bogie connections requiring EN 45545 halogen-free fire behavior.
- High-power frequency converters, UPS battery/busbar interconnects, wind-turbine nacelles and compact power-electronics racks.
- Pre-assembled multi-layer high-current silicone jumpers (50–300 mm²) with solderless pressed seamless copper contact ends and additional insulation crimps.
TF-SIHC Double-Insulated Silicone vs NSGAFÖU vs 5 kV Motor Lead
| Cable Family | Voltage & Insulation | Continuous Temp & Stranding | Optimal Engineering Use |
|---|---|---|---|
| TF-SIHC (this page) | 1.8/3 kV & 3.6/6 kV dual-wall halogen-free silicone | -50 to +180 °C; 0.07/0.10 mm ultra-fine Cu | High-density MV switchboards, traction converters & pressed cubicle jumpers |
| NSGAFÖU / NSHXAFÖ 1.8/3 kV | 1.8/3 kV EPR rubber + PCP/LSZH sheath | -25 to +90 °C; IEC Class 5 | Standard +90 °C industrial switchgear & rail cabinet wiring |
| Braidless 5 kV Silicone Motor Lead | 5 kV North American stator lead | +200 °C; motor-winding lead build | MV electric motor stator overhaul & Class H coil exits |
| TF-ACHC Air-Cooled Connector | Low-voltage bare, PVC or +800 °C pyrojacket | 70–1,000 mm²; 0.10 mm ultra-flexible | High-current LV furnace/switchgear flexible copper connectors |
Choose TF-SIHC over NSGAFÖU whenever cabinet ambient temperatures exceed +60 °C, conductor temperatures exceed +90 °C, or 3.6/6 kV double-insulated ultra-fine flexibility is required.
TF-SIHC Silicone High-Current Cable & Jumper RFQ Checklist
- Voltage grade required: TF-SIHC-183 (1.8/3 kV) or TF-SIHC-366 (3.6/6 kV), unscreened or tinned-copper braided EMC screened (-C).
- Conductor cross-section (2.5 mm² to 300 mm²) and uncoated bare copper vs tinned copper preference.
- Supply form: bulk continuous reel length (m) OR pre-terminated jumpers (exact hole-to-hole length, lug type: pressed seamless sleeve, narrow-flange tubular lug or DIN 46234, bolt hole Ø, single vs 2/3/4-layer stack).
- Outer silicone jacket color (reddish-brown, black, orange or custom) and fire-performance test requirement (IEC 60332-3-24 / EN 45545).
- Order quantity (MOQ 50 m bulk >=10 mm² / 100 m <=6 mm² / 10 pcs terminated jumpers; lead time 7 to 45 working days).
Related selection resources
- Explore TEBAOFLEX High-Voltage Silicone Cable Manufacturing Capabilities
- Read Real Export Case: 5 kV 200 °C 1×150 mm² Dual-Wall Silicone Cable (Oman)
- Compare NSGAFÖU 1.8/3 kV +90 °C EPR Rubber Single-Core Switchgear Cable
- Compare TF-ACHC Low-Voltage Air-Cooled High-Current Copper Connectors
- Browse All High-Temperature Silicone & Furnace Cables
TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Silicone Cable FAQ
Why does TF-SIHC use 0.07 mm and 0.10 mm copper wire stranding instead of standard Class 5?
0.07 mm (2.5–16 mm²) and 0.10 mm (25–300 mm²) individual copper strands double bending flexibility compared to IEC Class 5, allowing 120–300 mm² cables to clear tight 4× OD bends inside compact 1.8/3 kV and 3.6/6 kV switchgear cabinets without stressing breaker terminals.
What is the advantage of TF-SIHC double-insulated silicone over single-wall silicone wire?
2 extruded halogen-free silicone layers—a contrast-colored inner primary dielectric wall plus a tough outer protective jacket—deliver reliable 1.8/3 kV and 3.6/6 kV short-circuit-proof clearance, visual nick detection and higher tear resistance than single-wall SiF wire.
Can TEBAOFLEX supply TF-SIHC as ready-to-install pre-terminated switchgear jumpers?
Yes. TF-SIHC 4–300 mm² is supplied either on continuous reels or pre-assembled with solderless pressed seamless copper contact sleeves (1-to-4-layer stacks), narrow-flange tubular lugs or DIN 46234 lugs sealed with silicone transition sleeves from a 10-piece MOQ.
Does TEBAOFLEX claim UL Listing on TF-SIHC 1.8/3 kV or 3.6/6 kV cables?
No. TF-SIHC is engineered to DIN EN 13602, IEC 60332-3-24, EN 45545-2 and UL Style 30119 dimensional construction specifications, and TEBAOFLEX does not claim UL Listing for this product (our archived UL Certificate UL-US-2449012-4 covers UL 62 ZJCZ flexible cords).
What is the MOQ and lead time for TF-SIHC 1.8/3 kV and 3.6/6 kV silicone cables?
50 m per size for bulk reels 10–300 mm² (100 m for 2.5–6 mm²) or 10 pieces per drawing for pre-terminated high-current silicone jumpers, manufactured in 7 to 45 working days.
TF-SIHC (2.5–300 mm²) Dimensional, Resistance & Ampacity Schedule
TF-SIHC Voltage, Stranding, Fire Safety & MOQ Summary
- 1.8/3 kV & 3.6/6 kV dual-wall silicone: Contrast-colored inner primary silicone insulation plus rugged outer halogen-free silicone sheath (9–10 kV AC spark tested) for safe MV clearance
- 0.07 mm & 0.10 mm super-fine Cu strands: DIN EN 13602 soft-annealed bare copper wires (exceeding IEC Class 6 flexibility) bend cleanly inside tight high-density switchgear cubicles
- -50 °C to +180 °C & EN 45545 fire design: Halogen-free, low-smoke, self-extinguishing silicone compound engineered to IEC 60332-1-2, IEC 60332-3-24 and EN 45545 railway fire requirements
- Bulk reel OR pressed-sleeve jumpers: Order as continuous reels (MOQ 50 m for >=10 mm² / 100 m for <=6 mm²) or factory-crimped multi-layer jumpers with tubular lugs or seamless sleeves
- Optional copper EMC braid screen: Available unscreened or with tinned-copper braided EMC screen + outer silicone jacket for inverter, traction and MV converter bays
| Parameter | Value |
|---|---|
| Rated voltage | 1.8/3 kV AC (TF-SIHC-183) and 3.6/6 kV AC (TF-SIHC-366) double-insulated halogen-free silicone with 9 to 10 kV AC spark test |
| Conductor stranding and size range | 2.5 mm2 to 300 mm2 ultra-fine soft-annealed Cu-ETP1 copper (0.07 mm wire for 2.5 to 16 mm2; 0.10 mm wire for 25 to 300 mm2) |
| Temperature and fire performance | -50 C to +180 C continuous operating temperature (+220 C short-term), halogen-free and flame-retardant to IEC 60332-1-2 and IEC 60332-3-24 |
| Supply and termination options | Bulk continuous reels or pre-terminated jumpers with pressed seamless Cu-ETP contact sleeves, narrow-flange tubular lugs or DIN 46234 lugs |
| Minimum order and lead time | 50 m bulk reel (10 mm2 and above), 100 m (2.5 to 6 mm2), or 10 pieces pre-terminated jumpers in 7 to 45 working days |
| Minimum bending radius | 4 x OD fixed installation and 6 x OD occasional flexing inside dense switchgear cubicles |
| Standards disclosure | Engineered to DIN EN 13602, IEC 60332, EN 45545-2 and UL Style 30119 dimensional specifications; UL Listing is not claimed |
TF-SIHC (2.5–300 mm²) 1.8/3 kV & 3.6/6 kV Silicone High-Current Schedule
| Model & Cross-Section | Single Wire Ø (mm) | 1.8/3 kV Nom. OD (mm) | 3.6/6 kV Nom. OD (mm) | Current at 30 °C Air / 180 °C (A) | Max. R_DC at 20 °C (Ω/km) | Supply MOQ (Bulk / Jumper) | Next step |
|---|---|---|---|---|---|---|---|
| TF-SIHC 1×2.5 mm² | 0.07 | 6.2 | 7.4 | 32 – 48 | 7.98 | 100 m / 10 pcs | Request this size |
| TF-SIHC 1×6 mm² | 0.07 | 7.6 | 8.8 | 54 – 82 | 3.30 | 100 m / 10 pcs | Request this size |
| TF-SIHC 1×10 mm² | 0.07 | 9.0 | 10.2 | 73 – 115 | 1.91 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×16 mm² | 0.07 | 10.4 | 11.6 | 98 – 155 | 1.21 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×25 mm² | 0.10 | 12.2 | 13.6 | 129 – 205 | 0.780 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×35 mm² | 0.10 | 13.8 | 15.2 | 158 – 255 | 0.554 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×50 mm² | 0.10 | 15.8 | 17.4 | 198 – 315 | 0.386 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×70 mm² | 0.10 | 18.0 | 19.8 | 245 – 390 | 0.272 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×95 mm² | 0.10 | 20.4 | 22.2 | 292 – 470 | 0.206 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×120 mm² | 0.10 | 22.6 | 24.6 | 344 – 545 | 0.161 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×150 mm² | 0.10 | 25.0 | 27.0 | 391 – 625 | 0.129 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×185 mm² | 0.10 | 27.4 | 29.6 | 448 – 715 | 0.106 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×240 mm² | 0.10 | 31.0 | 33.4 | 528 – 840 | 0.0801 | 50 m / 10 pcs | Request this size |
| TF-SIHC 1×300 mm² | 0.10 | 34.4 | 37.0 | 608 – 960 | 0.0641 | 50 m / 10 pcs | Request this size |
Current columns show typical free-air ampacity range from +70 °C to +180 °C conductor temperature at +30 °C ambient (IEC 60228 / DIN VDE 0298-4 reference basis). Pre-terminated multi-layer jumpers (1 to 4 parallel layers of 50–300 mm²) and screened EMC versions (-C) are quoted to exact length and bolt-hole drawing. These standards reflect construction design references and are not third-party certifications held by TEBAOFLEX for this product.
ASCII part references for BOM and ERP entry: TF-SIHC-183-10, TF-SIHC-183-25, TF-SIHC-183-50, TF-SIHC-183-70, TF-SIHC-183-95, TF-SIHC-183-120, TF-SIHC-183-150, TF-SIHC-183-185, TF-SIHC-183-240, TF-SIHC-183-300, TF-SIHC-366-50, TF-SIHC-366-95, TF-SIHC-366-150, TF-SIHC-366-240, TF-SIHC-366-300.
TF-SIHC Reference Conductor & Flame-Retardancy Standards
| Standard or specification | Application |
|---|---|
| DIN EN 13602 & IEC 60228 (Extra-Fine 0.07/0.10 mm Stranding) | Soft-annealed electrolytic Cu-ETP1 conductor stranding engineered for ultra-tight cubicle bending and long vibration life. |
| IEC 60332-1-2, IEC 60332-3-24, IEC 60754-1/2 & EN 45545-2 Design Reference | Halogen-free, low-corrosivity, vertical-flame-retardant dual-wall silicone compound; dimensional reference aligned with UL Style 30119 (UL Listing not claimed). |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and spark / high-voltage routine testing
DIN EN 13602 — Drawn Round Copper Wire for Electrical Conductors
IEC 60332-3-24 — Vertical Flame Spread Test of Bunched Wires or Cables (Category C)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-LIFY LifY 1 kV, ESUY Braided & TPE-U 450/750 V Extra-Flexible High-Current & Earthing Cable (2.5–240 mm²)
A related cable option for a different application or duty profile.
View productTF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed)
A related cable option for a different application or duty profile.
View productYGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.