High Temperature Cables TEBAOFLEX

TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Extra-Flexible Silicone High-Current Switchgear Cable (2.5–300 mm²)

TF-SIHC (TF-SIHC-183 1.8/3 kV and TF-SIHC-366 3.6/6 kV) is a halogen-free, self-extinguishing double-insulated extra-flexible silicone high-current cable spanning 2.5 mm² to 300 mm² with 0.07 mm / 0.10 mm super-fine annealed Cu-ETP1 copper stranding (DIN EN 13602). Engineered for -50 °C to +180 °C switchgear cabinets, traction converters and transformers, supplied as bulk reel (MOQ 50 m) or pre-terminated jumpers with pressed seamless copper sleeves (MOQ 10 pcs).

Product information
SKU
TF-SIHC-36KV
Brand
TEBAOFLEX
Product overview

TF-SIHC 1.8/3 kV (TF-SIHC-183) and 3.6/6 kV (TF-SIHC-366) double-insulated extra-flexible silicone high-current cables (2.5 mm² to 300 mm², -50 °C to +180 °C continuous, 10 kV AC spark tested) provide compact, short-circuit-proof air-cooled power interconnections inside medium-voltage switchboards, traction converters, dry-type transformers and industrial rectifier cabinets.

Conventional 1.8/3 kV rubber cables such as NSGAFÖU cap out at +90 °C with Class 5 stranding that resists tight cubicle bends, whereas standard 300/500 V SiF single-wall silicone wire lacks the dielectric thickness and mechanical sheath durability required for 3 kV and 6 kV systems. TF-SIHC pairs ultra-fine 0.07 mm (2.5–16 mm²) and 0.10 mm (25–300 mm²) annealed Cu-ETP1 copper ropes with two extruded layers of ~60 Shore A halogen-free, ozone- and UV-resistant silicone rubber—allowing tight 4× OD fixed routing and solderless high-compression crimping into seamless copper contact sleeves or narrow-flange tubular lugs.

Specify TF-SIHC-183 (1.8/3 kV) or TF-SIHC-366 (3.6/6 kV) for high-temperature European IEC switchgear, railway rolling-stock converters and compact busbar jumpers; choose NSGAFÖU / NSHXAFÖ where standard +90 °C EPR rubber suffices, or TF-ACHC for low-voltage 70–1,000 mm² bare/pyrojacketed furnace jumpers. Bulk MOQ 50 m (>=10 mm²) / 100 m (<=6 mm²), or 10 pcs for pre-terminated jumpers, in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Silicone Construction

Engineered to DIN EN 13602 conductor purity and IEC 60332 / EN 45545 halogen-free flame-retardancy criteria; also built to UL Style 30119 dimensional design (note: UL Listing is not claimed for this product).

Clean 2D circular engineering cross-section of TF-SIHC 3.6/6 kV double-insulated silicone cable showing ultra-fine multi-strand bare copper core, thick white inner primary silicone insulation and smooth reddish-brown outer silicone sheath
Dual-wall dielectric cross-section: super-fine copper stranding, inner high-dielectric silicone insulation and protective outer halogen-free silicone sheath.
TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Extra-Flexible Silicone High-Current Switchgear Cable (2.5–300 mm²) construction
ComponentMaterial and construction
1. Super-Fine Soft-Annealed Cu-ETP1 Copper Conductor (DIN EN 13602)Uncoated (or optional tinned) ultra-fine stranded ropes using 0.07 mm single wires (2.5–16 mm²) and 0.10 mm single wires (25–300 mm²) for effortless tight-radius switchgear routing.
2. Inner Primary Halogen-Free Silicone InsulationExtruded high-dielectric cross-linked silicone rubber (~20 kV/mm dielectric strength, contrast natural/white color for instant nick/wear inspection during stripping).
3. Outer Protective Self-Extinguishing Silicone SheathTough ~60 Shore A halogen-free silicone jacket (reddish-brown, black or custom color) resistant to -50 °C cold flex, +180 °C continuous heat (+220 °C peak), ozone, UV and condensation.
4. Optional Tinned-Copper EMC Braid & Pressed Contact TerminationsOptional braided copper screen for VFD/converter EMC suppression, plus optional factory-pressed seamless Cu-ETP contact sleeves (1-to-4-layer stacks), DIN 46234 lugs or narrow-flange tubular lugs with silicone transition sleeves.

TF-SIHC Voltage, Screen & Termination Code Breakdown

  • TF-SIHC-183: 1.8/3 kV AC double-insulated extra-flexible halogen-free silicone high-current cable (2.5–300 mm²)
  • TF-SIHC-366: 3.6/6 kV AC double-insulated extra-flexible halogen-free silicone high-current cable (2.5–300 mm²)
  • -C: Optional tinned-copper braided EMC screen under an outer silicone sheath for traction/VFD bays
  • -SL / -TL: Pre-terminated jumper options: Pressed Seamless Copper Contact Sleeve (-SL) or Narrow-Flange Tubular Lug (-TL)
  • -2L / -3L / -4L: Multi-layer parallel pre-terminated silicone jumper stack (2, 3 or 4 parallel cables pressed into one contact head)
Applications

TF-SIHC MV Switchgear, Traction Converter & Transformer Duty

Designed for compact high-current air-cooled connections where high voltage, extreme ambient heat, tight bending clearances and halogen-free fire safety converge.

Medium-voltage industrial switchgear cabinet and traction converter bay wired with flexible reddish-brown TF-SIHC double-insulated silicone high-current jumper cables fitted with pressed silver-tinned copper lugs bolted onto heavy copper busbars
High-density industrial switchgear busbar interconnection using pre-terminated TF-SIHC 1.8/3 kV and 3.6/6 kV flexible silicone jumpers.
  • Medium-voltage 1.8/3 kV and 3.6/6 kV industrial switchgear cubicles, breaker trucks and transformer secondary taps.
  • Railway rolling-stock traction inverters, auxiliary converters and roof-to-bogie connections requiring EN 45545 halogen-free fire behavior.
  • High-power frequency converters, UPS battery/busbar interconnects, wind-turbine nacelles and compact power-electronics racks.
  • Pre-assembled multi-layer high-current silicone jumpers (50–300 mm²) with solderless pressed seamless copper contact ends and additional insulation crimps.

TF-SIHC Double-Insulated Silicone vs NSGAFÖU vs 5 kV Motor Lead

TF-SIHC (1.8/3 & 3.6/6 kV Silicone) vs NSGAFÖU (1.8/3 kV EPR) vs TF-ACHC (LV High-Current) vs 5 kV Motor Lead
Cable FamilyVoltage & InsulationContinuous Temp & StrandingOptimal Engineering Use
TF-SIHC (this page)1.8/3 kV & 3.6/6 kV dual-wall halogen-free silicone-50 to +180 °C; 0.07/0.10 mm ultra-fine CuHigh-density MV switchboards, traction converters & pressed cubicle jumpers
NSGAFÖU / NSHXAFÖ 1.8/3 kV1.8/3 kV EPR rubber + PCP/LSZH sheath-25 to +90 °C; IEC Class 5Standard +90 °C industrial switchgear & rail cabinet wiring
Braidless 5 kV Silicone Motor Lead5 kV North American stator lead+200 °C; motor-winding lead buildMV electric motor stator overhaul & Class H coil exits
TF-ACHC Air-Cooled ConnectorLow-voltage bare, PVC or +800 °C pyrojacket70–1,000 mm²; 0.10 mm ultra-flexibleHigh-current LV furnace/switchgear flexible copper connectors

Choose TF-SIHC over NSGAFÖU whenever cabinet ambient temperatures exceed +60 °C, conductor temperatures exceed +90 °C, or 3.6/6 kV double-insulated ultra-fine flexibility is required.

TF-SIHC Silicone High-Current Cable & Jumper RFQ Checklist

  • Voltage grade required: TF-SIHC-183 (1.8/3 kV) or TF-SIHC-366 (3.6/6 kV), unscreened or tinned-copper braided EMC screened (-C).
  • Conductor cross-section (2.5 mm² to 300 mm²) and uncoated bare copper vs tinned copper preference.
  • Supply form: bulk continuous reel length (m) OR pre-terminated jumpers (exact hole-to-hole length, lug type: pressed seamless sleeve, narrow-flange tubular lug or DIN 46234, bolt hole Ø, single vs 2/3/4-layer stack).
  • Outer silicone jacket color (reddish-brown, black, orange or custom) and fire-performance test requirement (IEC 60332-3-24 / EN 45545).
  • Order quantity (MOQ 50 m bulk >=10 mm² / 100 m <=6 mm² / 10 pcs terminated jumpers; lead time 7 to 45 working days).

Related selection resources

TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Silicone Cable FAQ

Why does TF-SIHC use 0.07 mm and 0.10 mm copper wire stranding instead of standard Class 5?

0.07 mm (2.5–16 mm²) and 0.10 mm (25–300 mm²) individual copper strands double bending flexibility compared to IEC Class 5, allowing 120–300 mm² cables to clear tight 4× OD bends inside compact 1.8/3 kV and 3.6/6 kV switchgear cabinets without stressing breaker terminals.

What is the advantage of TF-SIHC double-insulated silicone over single-wall silicone wire?

2 extruded halogen-free silicone layers—a contrast-colored inner primary dielectric wall plus a tough outer protective jacket—deliver reliable 1.8/3 kV and 3.6/6 kV short-circuit-proof clearance, visual nick detection and higher tear resistance than single-wall SiF wire.

Can TEBAOFLEX supply TF-SIHC as ready-to-install pre-terminated switchgear jumpers?

Yes. TF-SIHC 4–300 mm² is supplied either on continuous reels or pre-assembled with solderless pressed seamless copper contact sleeves (1-to-4-layer stacks), narrow-flange tubular lugs or DIN 46234 lugs sealed with silicone transition sleeves from a 10-piece MOQ.

Does TEBAOFLEX claim UL Listing on TF-SIHC 1.8/3 kV or 3.6/6 kV cables?

No. TF-SIHC is engineered to DIN EN 13602, IEC 60332-3-24, EN 45545-2 and UL Style 30119 dimensional construction specifications, and TEBAOFLEX does not claim UL Listing for this product (our archived UL Certificate UL-US-2449012-4 covers UL 62 ZJCZ flexible cords).

What is the MOQ and lead time for TF-SIHC 1.8/3 kV and 3.6/6 kV silicone cables?

50 m per size for bulk reels 10–300 mm² (100 m for 2.5–6 mm²) or 10 pieces per drawing for pre-terminated high-current silicone jumpers, manufactured in 7 to 45 working days.

Specifications

TF-SIHC (2.5–300 mm²) Dimensional, Resistance & Ampacity Schedule

TF-SIHC Voltage, Stranding, Fire Safety & MOQ Summary

  • 1.8/3 kV & 3.6/6 kV dual-wall silicone: Contrast-colored inner primary silicone insulation plus rugged outer halogen-free silicone sheath (9–10 kV AC spark tested) for safe MV clearance
  • 0.07 mm & 0.10 mm super-fine Cu strands: DIN EN 13602 soft-annealed bare copper wires (exceeding IEC Class 6 flexibility) bend cleanly inside tight high-density switchgear cubicles
  • -50 °C to +180 °C & EN 45545 fire design: Halogen-free, low-smoke, self-extinguishing silicone compound engineered to IEC 60332-1-2, IEC 60332-3-24 and EN 45545 railway fire requirements
  • Bulk reel OR pressed-sleeve jumpers: Order as continuous reels (MOQ 50 m for >=10 mm² / 100 m for <=6 mm²) or factory-crimped multi-layer jumpers with tubular lugs or seamless sleeves
  • Optional copper EMC braid screen: Available unscreened or with tinned-copper braided EMC screen + outer silicone jacket for inverter, traction and MV converter bays
TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Extra-Flexible Silicone High-Current Switchgear Cable (2.5–300 mm²) technical data
ParameterValue
Rated voltage1.8/3 kV AC (TF-SIHC-183) and 3.6/6 kV AC (TF-SIHC-366) double-insulated halogen-free silicone with 9 to 10 kV AC spark test
Conductor stranding and size range2.5 mm2 to 300 mm2 ultra-fine soft-annealed Cu-ETP1 copper (0.07 mm wire for 2.5 to 16 mm2; 0.10 mm wire for 25 to 300 mm2)
Temperature and fire performance-50 C to +180 C continuous operating temperature (+220 C short-term), halogen-free and flame-retardant to IEC 60332-1-2 and IEC 60332-3-24
Supply and termination optionsBulk continuous reels or pre-terminated jumpers with pressed seamless Cu-ETP contact sleeves, narrow-flange tubular lugs or DIN 46234 lugs
Minimum order and lead time50 m bulk reel (10 mm2 and above), 100 m (2.5 to 6 mm2), or 10 pieces pre-terminated jumpers in 7 to 45 working days
Minimum bending radius4 x OD fixed installation and 6 x OD occasional flexing inside dense switchgear cubicles
Standards disclosureEngineered to DIN EN 13602, IEC 60332, EN 45545-2 and UL Style 30119 dimensional specifications; UL Listing is not claimed

TF-SIHC (2.5–300 mm²) 1.8/3 kV & 3.6/6 kV Silicone High-Current Schedule

TF-SIHC-183 (1.8/3 kV) & TF-SIHC-366 (3.6/6 kV) Double-Insulated Extra-Flexible Silicone High-Current Cable Schedule (2.5–300 mm²)
Model & Cross-SectionSingle Wire Ø (mm)1.8/3 kV Nom. OD (mm)3.6/6 kV Nom. OD (mm)Current at 30 °C Air / 180 °C (A)Max. R_DC at 20 °C (Ω/km)Supply MOQ (Bulk / Jumper)Next step
TF-SIHC 1×2.5 mm²0.076.27.432 – 487.98100 m / 10 pcsRequest this size
TF-SIHC 1×6 mm²0.077.68.854 – 823.30100 m / 10 pcsRequest this size
TF-SIHC 1×10 mm²0.079.010.273 – 1151.9150 m / 10 pcsRequest this size
TF-SIHC 1×16 mm²0.0710.411.698 – 1551.2150 m / 10 pcsRequest this size
TF-SIHC 1×25 mm²0.1012.213.6129 – 2050.78050 m / 10 pcsRequest this size
TF-SIHC 1×35 mm²0.1013.815.2158 – 2550.55450 m / 10 pcsRequest this size
TF-SIHC 1×50 mm²0.1015.817.4198 – 3150.38650 m / 10 pcsRequest this size
TF-SIHC 1×70 mm²0.1018.019.8245 – 3900.27250 m / 10 pcsRequest this size
TF-SIHC 1×95 mm²0.1020.422.2292 – 4700.20650 m / 10 pcsRequest this size
TF-SIHC 1×120 mm²0.1022.624.6344 – 5450.16150 m / 10 pcsRequest this size
TF-SIHC 1×150 mm²0.1025.027.0391 – 6250.12950 m / 10 pcsRequest this size
TF-SIHC 1×185 mm²0.1027.429.6448 – 7150.10650 m / 10 pcsRequest this size
TF-SIHC 1×240 mm²0.1031.033.4528 – 8400.080150 m / 10 pcsRequest this size
TF-SIHC 1×300 mm²0.1034.437.0608 – 9600.064150 m / 10 pcsRequest this size

Current columns show typical free-air ampacity range from +70 °C to +180 °C conductor temperature at +30 °C ambient (IEC 60228 / DIN VDE 0298-4 reference basis). Pre-terminated multi-layer jumpers (1 to 4 parallel layers of 50–300 mm²) and screened EMC versions (-C) are quoted to exact length and bolt-hole drawing. These standards reflect construction design references and are not third-party certifications held by TEBAOFLEX for this product.

ASCII part references for BOM and ERP entry: TF-SIHC-183-10, TF-SIHC-183-25, TF-SIHC-183-50, TF-SIHC-183-70, TF-SIHC-183-95, TF-SIHC-183-120, TF-SIHC-183-150, TF-SIHC-183-185, TF-SIHC-183-240, TF-SIHC-183-300, TF-SIHC-366-50, TF-SIHC-366-95, TF-SIHC-366-150, TF-SIHC-366-240, TF-SIHC-366-300.

Standards

TF-SIHC Reference Conductor & Flame-Retardancy Standards

TF-SIHC 1.8/3 kV & 3.6/6 kV Double-Insulated Extra-Flexible Silicone High-Current Switchgear Cable (2.5–300 mm²) standards and test references
Standard or specificationApplication
DIN EN 13602 & IEC 60228 (Extra-Fine 0.07/0.10 mm Stranding)Soft-annealed electrolytic Cu-ETP1 conductor stranding engineered for ultra-tight cubicle bending and long vibration life.
IEC 60332-1-2, IEC 60332-3-24, IEC 60754-1/2 & EN 45545-2 Design ReferenceHalogen-free, low-corrosivity, vertical-flame-retardant dual-wall silicone compound; dimensional reference aligned with UL Style 30119 (UL Listing not claimed).

Certifications and document support

TEBAOFLEX ISO 9001 quality management and spark / high-voltage routine testing

DIN EN 13602 — Drawn Round Copper Wire for Electrical Conductors

IEC 60332-3-24 — Vertical Flame Spread Test of Bunched Wires or Cables (Category C)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.