Airport Ground Power Cables TEBAOFLEX

Airport Pavement & Secondary AGL Cable 600 V (PVC/Polyamide Saw-Cut & FAA L-824 Type B/C)

Airport Pavement & Secondary AGL Cable (600 V, 2 kV AC test) covers all three non-shielded secondary airfield ground lighting (AGL) circuit constructions running from isolation transformers to inset runway, taxiway and apron fixtures: ultra-slim Ø 4.5 mm 1×4 mm² PVC/Polyamide (Nylon) saw-cut pavement cable (-40 °C to +85 °C), FAA L-824 Type C (XLPE / PE or PVC, 1×2.5–2×10 mm² & 12–6 AWG) and FAA L-824 Type B flexible elastomer (EPR / CPE-XL-HD & H07RN-F secondary AGL, -25 °C to +90 °C).

Product information
SKU
TF-AGL-PAVE-600V
Brand
TEBAOFLEX
Product overview

Airport Pavement and Secondary AGL Cable (600 V AC, 2 kV AC routine test) provides the dedicated secondary-side wiring linking constant-current 6.6 A isolation transformers inside airfield manholes and base cans directly to inset runway center-line, touchdown-zone, stop-bar and taxiway LED/halogen light fixtures.

Installing secondary AGL leads directly inside narrow diamond-sawed asphalt or concrete pavement slots exposes the outer jacket to razor-sharp aggregate walls, hot-pour epoxy/bitumen sealants, aviation turbine fuel (Jet A-1), glycol runway de-icers and wide thermal swings from -40 °C frost to +85 °C summer tarmac. Our Airport Pavement Cable pairs 1×4 mm² stranded copper (IEC 60228 Class 2) with 85 °C PVC insulation and a slick, abrasion-proof black Polyamide (Nylon, PA) outer sheath measuring just 4.5 mm OD (49 kg/km) for effortless slot seating and watertight sealing. For deeper conduit and transformer-to-light runs, we equally manufacture 600 V FAA L-824 Type C (XLPE insulated, PE/PVC/LSZH jacketed per NEMA WC 70 / ICEA S-95-658) and flexible FAA L-824 Type B (EPR insulated, heavy-duty CPE-XL-HD or H07RN-F rubber jacketed) across 1×2.5 to 2×10 mm² and 12 AWG to 6 AWG.

Pair this 600 V Airport Pavement & Secondary AGL series with our 5 kV FAA L-824 Brass-Tape Armoured / Unscreened Primary AGL cables or 5 kV Copper-Tape/Braid Primary AGL cables for complete runway lighting packages. Minimum order 50 m; lead time 7 to 45 working days.

Explore the 400 Hz airport ground power cable range for related configurations.

Construction

Airport Pavement (PVC/PA) & 600 V Secondary AGL Construction

Three specialized 600 V secondary AGL architectures: ultra-slim PVC/Polyamide saw-cut pavement cable, FAA L-824 Type C (XLPE/PE-PVC) and flexible FAA L-824 Type B (EPR/CPE-rubber).

Clean 2D technical cross-section of single-core 1x4 mm2 Airport Pavement 600 V secondary AGL cable showing thin hard black polyamide nylon abrasion jacket, thick translucent pale PVC insulation ring and 7-wire compacted bare copper conductor
Single-core Airport Pavement cable cross-section engineered for narrow saw-cut runway slots, de-icers, aviation fuel and -40 °C to +85 °C weather.
Airport Pavement & Secondary AGL Cable 600 V (PVC/Polyamide Saw-Cut & FAA L-824 Type B/C) construction
ComponentMaterial and construction
1. Stranded Annealed Bare or Tinned Copper ConductorIEC 60228 Class 2 / Class 5 (2.5, 4, 6, 10 mm²) or ASTM B8 Class B / Class C (12, 10, 8, 6 AWG) for low-loss 6.6 A–20 A fixture feeds.
2. 85 °C PVC (Pavement), 90 °C XLPE (Type C) or EPR (Type B) InsulationColorless 85 °C PVC on Airport Pavement builds; 90 °C cross-linked XLPE on FAA L-824 Type C; flexible 90 °C EPR/EI4 elastomer on Type B / H07RN-F.
3. Polyamide (Nylon), PE/PVC or Heavy CPE/EM2 Outer JacketHard slick Polyamide (PA) compound resisting saw-cut slot abrasion (Pavement); UV-stabilized PE/PVC (Type C); oil- and fuel-resistant CPE-XL-HD or EM2 rubber (Type B).

Airport Pavement & FAA L-824 Secondary Code Breakdown

  • BCL2 / TCL2: Bare (B) or Tinned (T) IEC 60228 Class 2 copper; BCL5/TCL5 = flexible Class 5; BAWGB/TAWGB = ASTM B8 AWG
  • PVC / PA: 85 °C colorless PVC insulation + hard abrasion-resistant black Polyamide (Nylon) saw-cut pavement jacket
  • Type C (XLPE): FAA L-824 Type C 600 V secondary cable using 90 °C XLPE insulation with PE, PVC or LSZH jacket
  • Type B (EPR): FAA L-824 Type B 600 V flexible secondary cable using 90 °C EPR insulation with CPE-XL-HD or EM2 rubber
  • Secondary AGL: 600 V non-shielded transformer-to-luminaire airfield circuit cable (2 kV test, 5 × D bend)
Applications

Airport Pavement Runway Slot & Secondary AGL Applications

Engineered for secondary airfield ground lighting (AGL) circuits connecting isolation transformers to inset and elevated runway/taxiway luminaires.

International airport runway construction and inset lighting installation showing slim black 600 V Airport Pavement secondary AGL cables seated neatly into a narrow diamond-sawed tarmac slot leading to an inset runway center-line light
Runway inset lighting saw-cut slot installation wired with slim Ø 4.5 mm PVC/Polyamide Airport Pavement secondary AGL cables.
  • Diamond-sawed asphalt and concrete runway/taxiway pavement slots feeding inset center-line, touchdown-zone and rapid-exit lights (Ø 4.5 mm PVC/PA).
  • Conduit and underground duct secondary circuits from 6.6 A isolation transformers to elevated runway edge and PAPI approach fixtures (FAA L-824 Type C).
  • Flexible plug-in secondary fixture leads inside shallow base cans and vibrating airfield pit boxes (FAA L-824 Type B EPR/CPE & H07RN-F).
  • Cold-climate and tropical international airport apron lighting exposed to Jet A-1 spills, de-icing glycol and UV weathering.

Airport Pavement vs Secondary Type B/C vs 5 kV Primary AGL

Airport Pavement (PVC/PA) vs 600 V Secondary AGL (Type B/C) vs 5 kV Primary AGL Cables
Airfield Lighting CableVoltage & JacketTypical Size & ODExact Airfield Installation Zone
Airport Pavement (this page)600 V · PVC / Polyamide (PA)1×4 mm² (Ø 4.5 mm)Narrow saw-cut asphalt/concrete slots to inset runway lights
Secondary AGL Type C/B (this page)600 V · XLPE/PE or EPR/CPE1×2.5–2×10 mm² / 12–6 AWGTransformer secondary to fixture ducts, pits & base cans
Primary AGL 5 kV Brass/Unscr.5 kV · Semicon+XLPE/EPR+BRT1×6 mm², 8 AWG, 6 AWGConstant-current 5 kV CCR series loops (termite/direct-burial)
Primary AGL 5 kV Cu Tape/Braid5 kV · Semicon+XLPE+Cu Screen1×6 mm², 8 AWG, 6 AWGShielded 5 kV airfield primary rings near radar & ILS

Always match saw-cut slot width (typically 8–12 mm) and molded secondary FAA L-823 connector boot OD before finalizing single-core vs two-core secondary cable.

Airport Pavement & Secondary AGL 600 V Cable RFQ Checklist

  • Secondary tier: Airport Pavement 1×4 mm² (PVC/Polyamide Ø 4.5 mm), FAA L-824 Type C (XLPE/PE or PVC) or Type B (EPR/CPE or H07RN-F).
  • Conductor unit and layout: Metric (1×2.5–2×10 mm²) or AWG (12–6 AWG), bare or tinned copper, Class 2 or flexible Class 5.
  • Outer jacket preference (Polyamide Nylon, PE, PVC, LSZH or CPE-XL-HD) and compatibility with FAA L-823 molded plug kits.
  • Order length per item (MOQ 50 m) and project dispatch schedule (standard 7 to 45 working days).

Related selection resources

Airport Pavement & Secondary AGL 600 V Cable FAQ

Why does Airport Pavement Cable use a Polyamide (Nylon) outer jacket over PVC?

At just 4.5 mm outer diameter (1×4 mm²), the hard slick Polyamide (Nylon) jacket resists sharp diamond-sawed concrete slot edges, aviation jet fuel, runway de-icing fluids and hot sealant pours across -40 °C to +85 °C.

What is the difference between FAA L-824 Type C and Type B 600 V Secondary AGL cables?

Type C pairs 90 °C cross-linked polyethylene (XLPE) insulation with a PE, PVC or halogen-free jacket (NEMA WC 70) for conduit and direct burial, whereas Type B pairs flexible 90 °C EPR insulation with a tough CPE-XL-HD or polychloroprene rubber jacket for tight base-can bends.

What voltage and test rating apply to Airport Pavement and Secondary AGL cables?

600 V AC rated voltage with a 2 kV AC factory routine withstand test voltage and 5 × D minimum bending radius.

Are both metric (mm²) and US AWG sizes available for 600 V Secondary AGL cables?

Yes. We manufacture metric 1×2.5 to 2×10 mm² (IEC 60228 Class 2/5) and imperial 12, 10, 8 and 6 AWG (ASTM B8 Class B/C) in bare or tinned copper.

What is the MOQ and lead time for Airport Pavement and Secondary AGL cables?

50 m minimum order per size and jacket type, custom-manufactured in 7 to 45 working days with factory routine 2 kV dielectric records.

Specifications

Airport Pavement & Secondary AGL Dimension Schedule

Airport Pavement Electrical, Thermal & De-Icer Ratings

  • Ultra-slim Ø 4.5 mm PVC/Polyamide saw-cut build: 1×4 mm² colorless 85 °C PVC + hard black Polyamide (Nylon) jacket resists concrete saw-cut abrasion, jet fuel, de-icers and UV (-40 to +85 °C)
  • FAA L-824 Type C & Type B secondary builds: Type C (XLPE / PE or PVC, NEMA WC 70) for conduit/direct-burial feeds and Type B (EPR / CPE-XL-HD or H07RN-F) for flexible fixture leads
  • Metric (2.5–10 mm²) & AWG (12–6 AWG) coverage: 1-core and 2-core builds in Class 2 / Class 5 IEC 60228 or ASTM B8 Class B/C bare or tinned copper
  • 600 V AC rating with tight 5 × D bending: 2 kV AC routine test voltage, oil/de-icer resistance (UL 1581 / ISO 4892-2 UV, UNE 21123-2) for tight runway base-can turns
  • 50 m MOQ and airport-project reel dispatch: Matched to FAA AC 150/5345-7F secondary connector kits, custom-manufactured in 7 to 45 working days
Airport Pavement & Secondary AGL Cable 600 V (PVC/Polyamide Saw-Cut & FAA L-824 Type B/C) technical data
ParameterValue
Rated voltage600 V AC secondary airfield lighting circuits (2 kV AC routine withstand test voltage)
Operating temperature range-40 °C to +85 °C (PVC/Polyamide Pavement); -25 °C to +90 °C (FAA L-824 Type C XLPE and Type B EPR)
Outer diameter and bendingUltra-slim 4.5 mm OD on 1×4 mm² PVC/PA pavement cable; 5 × D minimum bending radius across all 600 V AGL builds
Conductor and jacket optionsMetric 1×2.5–2×10 mm² and 12–6 AWG bare/tinned copper; Polyamide (Nylon), PE, PVC, LSZH, CPE-XL-HD or EM2 rubber
Environmental resistanceAbrasion-, oil-, aviation-fuel-, de-icer- and UV-resistant per UL 1581, ISO 4892-2 and UNE 21123-2
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

Airport Pavement & 600 V Secondary AGL Cable Dimension Schedule

Airport Pavement (PVC/PA) & 600 V FAA L-824 Type C / Type B Secondary AGL Exact Schedule
Model & SizeAGL Build (Cond/Ins/Jacket)Nominal OD (mm)Approx. Weight (kg/km)Max DC R @20 °C (Ω/km)Current Rating (A)Order MOQNext step
Airport Pavement AGL 1×4 mm²Cl.2 / PVC / Polyamide (PA)4.5494.6138 (@30 °C)50 mRequest this size
Secondary AGL Type C 1×4 mm²Cl.2 / XLPE / PE5.5544.6140 (@45 °C)50 mRequest this size
Secondary AGL Type C 1×6 mm²Cl.2 / XLPE / PVC6.1803.0852 (@45 °C)50 mRequest this size
Secondary AGL Type C 2×2.5 mm²Cl.2 / XLPE / PE10.01137.4126 (@45 °C)50 mRequest this size
Secondary AGL Type C 2×4 mm²Cl.2 / XLPE / PE11.01524.6134 (@45 °C)50 mRequest this size
Secondary AGL Type C 2×6 mm²Cl.5 / XLPE / PVC11.92263.3044 (@45 °C)50 mRequest this size
Secondary AGL Type C 2×10 AWGASTM B / XLPE / PE11.91883.3540 (@45 °C)50 mRequest this size
Secondary AGL Type C 2×8 AWGASTM B / XLPE / PVC16.03882.1054 (@45 °C)50 mRequest this size
Secondary AGL Type B 1×4 mm²Cl.5 / EPR / CPE-XL-HD5.4574.9540 (@45 °C)50 mRequest this size
Secondary AGL Type B 2×4 mm²Cl.5 / EPR / CPE-XL-HD10.81734.9534 (@45 °C)50 mRequest this size
Secondary AGL Type B 2×12 AWGASTM B / EPR / CPE-XL-HD10.71665.3430 (@45 °C)50 mRequest this size
Secondary AGL H07RN-F 2×2.5 mm²Cl.5 / EI4 EPR / EM2 Rubber10.61657.9836 (@30 °C)50 mRequest this size
Secondary AGL H07RN-F 2×4 mm²Cl.5 / EI4 EPR / EM2 Rubber12.22304.9549 (@30 °C)50 mRequest this size

All single-core and two-core metric (2.5, 4, 6, 10 mm²) and AWG (12, 10, 8, 6 AWG) variants are available with bare or tinned copper conductors and black, orange or custom color-coded jackets. Minimum laying temperature for PVC/Polyamide Pavement cable is -5 °C.

ASCII part references for BOM and ERP entry: AGL-PAVE-1x4, AGL-SEC-C-1x4-PE, AGL-SEC-C-1x6-PVC, AGL-SEC-C-2x2.5-PE, AGL-SEC-C-2x4-PE, AGL-SEC-C-2x6-PVC, AGL-SEC-C-2x10AWG, AGL-SEC-C-2x8AWG, AGL-SEC-B-1x4-CPE, AGL-SEC-B-2x4-CPE, AGL-SEC-B-2x12AWG, AGL-SEC-RN-2x2.5, AGL-SEC-RN-2x4.

Standards

Airport Pavement FAA AC 150/5345-7F & NEMA WC 70 Standards

Airport Pavement & Secondary AGL Cable 600 V (PVC/Polyamide Saw-Cut & FAA L-824 Type B/C) standards and test references
Standard or specificationApplication
FAA AC 150/5345-7F (L-824 Type B & C)Federal Aviation Administration design reference for 600 V secondary airfield lighting cables.
NEMA WC 70 / ICEA S-95-658 & UNE 21123-2600 V XLPE/EPR power-cable test methods and polyamide-jacketed pavement abrasion reference.
UL 1581, ISO 4892-2 & EN 50525-2-21UV weathering, oil resistance and H07RN-F flexible elastomer secondary AGL reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing quality and factory routine test records

FAA AC 150/5345-7F — Specification for L-824 Underground Electrical Cable for Airport Lighting Circuits

NEMA WC 70 / ICEA S-95-658 — 600 V–2,000 V Power Cables

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.