FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary Airfield Lighting Cable (Type C & Type B)
FAA L-824 5 kV Brass-Tape Armoured (18 kV AC test, ICEA S-93-639 / NEMA WC 74) and Unscreened (13 kV AC test, NEMA WC 71 / ICEA S-96-659) Primary Airfield Lighting Cables power constant-current 6.6 A / 20 A airport runway series loops across termite-, rodent- and moisture-prone soils. Supplied in both FAA L-824 Type C (XLPE / PE, PVC or LSZH) and flexible Type B (EPR / CPE-XL-HD) across 1×6 mm², 1×8 AWG and 1×6 AWG with extruded semiconductive conductor screens and -25 °C to +90 °C ratings.
FAA L-824 5 kV Brass-Tape Armoured and Unscreened Primary Airfield Lighting (AGL) Cables carry constant-current 6.6 A and 20 A series power from airport electrical vault Constant Current Regulators (CCRs) around kilometer-long runway, approach and taxiway primary loops under FAA AC 150/5345-7F, ICEA S-93-639 (NEMA WC 74) and ICEA S-96-659 (NEMA WC 71).
Across tropical, desert and coastal airports in the Middle East, Southeast Asia, Africa, Australia and Latin America, direct-buried and shallow-duct 5 kV runway series loops frequently suffer costly earth-fault blackouts caused by subterranean termites and rodents chewing through soft polymer jackets—or soil-moisture induced treeing. Our Brass-Tape Armoured FAA L-824 Type C (XLPE) and Type B (EPR) builds wrap a hard, corrosion-resistant helically overlapped brass tape (minimum 20% overlap, 100% coverage) directly over the semiconductive screen, creating a dual-purpose metallic fault shield and impenetrable mechanical anti-termite/rodent barrier tested at 18 kV AC. Where metallic screening is not specified on protected PVC/HDPE ducts, our Unscreened 5 kV FAA L-824 Type C and Type B constructions offer a streamlined 13 kV-tested build with an ultra-compact 5 × D bending radius.
Choose this page for 5 kV Brass-Tape Armoured (anti-termite/rodent) and Unscreened FAA L-824 Primary AGL loops; choose our existing 5 kV XLPE Copper-Tape & Copper-Braid Airfield Lighting Cable where standard copper screening is specified, and pair with our 600 V Airport Pavement & Secondary AGL series for the transformer-to-light leg. Minimum order 50 m; lead time 7 to 45 working days.
Explore the 400 Hz airport ground power cable range for related configurations.
FAA L-824 5 kV Brass-Tape Armoured & Unscreened Construction
5 kV airfield primary loop architecture combining Class 2 / ASTM B8 copper, extruded semiconductive conductor screen, 90 °C XLPE (Type C) or EPR (Type B) insulation, optional helical brass-tape shield/armour and PE/PVC/CPE outer jacket.

| Component | Material and construction |
|---|---|
| 1. Stranded Annealed Bare or Tinned Copper Conductor | 1×6 mm² (IEC 60228 Class 2) or 1×8 AWG / 1×6 AWG (ASTM B8 Class B/C) engineered for long-run low-resistance 6.6 A / 20 A CCR series circuits. |
| 2. Extruded Semiconductive Conductor Screen | Smooth bonded semiconductive shield eliminates strand-surface electric field spikes at 5 kV primary operating voltage. |
| 3. 90 °C XLPE (Type C) or EPR (Type B) Primary Insulation | High-dielectric cross-linked polyethylene (Type C) or flexible ethylene-propylene rubber (Type B) rated -25 °C to +90 °C continuous. |
| 4. Semiconductive Tape + 100% Overlapping Brass Tape (Armoured Variant) | Helically applied semiconductive tape plus minimum 20% overlap / 100% coverage brass tape provides metallic screening and impenetrable termite/rodent armour (omitted on Unscreened builds). |
| 5. PE, PVC, LSZH (Type C) or CPE-XL-HD / Neoprene (Type B) Jacket | UV-, moisture-, soil-chemical- and hydrocarbon-resistant outer jacket matching NEMA WC 74 / NEMA WC 71 airfield burial conditions. |
FAA L-824 Type C / Type B & Brass-Tape Code Breakdown
- FAA L-824: Federal Aviation Administration 5 kV underground primary airfield lighting cable designation
- Type C / Type B: Type C = 90 °C XLPE insulation (PE/PVC/LSZH jacket); Type B = flexible 90 °C EPR insulation (CPE/rubber)
- EXSC / SCT: Extruded semiconductive conductor screen (EXSC) and helical semiconductive insulation tape (SCT)
- BRT: 100% coverage (minimum 20% overlap) helical Brass Tape shield and anti-termite/rodent mechanical armour
- Unscreened: Non-shielded 5 kV primary option (13 kV AC test, tight 5 × D bend) per NEMA WC 71 / ICEA S-96-659
FAA L-824 Runway, Taxiway & Termite-Zone Airfield Applications
Engineered for 5 kV constant-current primary series loops feeding runway, taxiway, approach and apron isolation transformers worldwide.

- Direct-buried and shallow-duct 5 kV runway lighting rings in termite- and rodent-active tropical, desert and coastal airports (Brass-Tape Armoured).
- Constant Current Regulator (CCR) primary series loops feeding 6.6 A and 20 A airfield isolation transformers across civil and military airbases.
- Conduit-routed unscreened 5 kV FAA L-824 Type C (XLPE) and flexible Type B (EPR) airfield primary circuits requiring tight 5 × D pit turns.
- Runway expansion and LED AGL modernization projects specifying dual metric (1×6 mm²) or imperial (1×8 AWG, 1×6 AWG) primary loops.
FAA L-824 5 kV Brass-Tape vs Unscreened vs Copper-Tape AGL
| Airfield Cable Variant | Metallic Screen / Armour | Test Voltage & Bend | Best Airport Soil / Spec Condition |
|---|---|---|---|
| FAA L-824 Brass-Tape (this page) | 100% overlapping Brass Tape | 18 kV AC · 12 × D | Termite/rodent-prone soil, direct burial & harsh tropical airfields |
| FAA L-824 Unscreened (this page) | None (semicon+XLPE/EPR) | 13 kV AC · 5 × D | Protected PVC/HDPE ducts requiring tight pit bending & easy splicing |
| 5 kV Copper Tape / Braid AGL | Bare copper tape or braid | 18 kV AC · 12 × D | Standard shielded runway loops near ILS, radar & NAVAIDS |
| Airport Pavement / Sec. 600 V | None (PVC/PA or XLPE/EPR) | 2 kV AC · 5 × D | 600 V transformer-to-light saw-cut slots & fixture feeds |
Always bond brass-tape metallic shields per airport grounding rules at vault terminations and verify L-823 primary plug kit OD range (12.4–15.8 mm).
FAA L-824 5 kV Brass-Tape Primary AGL Cable RFQ Checklist
- Primary architecture: 5 kV Brass-Tape Armoured (18 kV test) vs 5 kV Unscreened (13 kV test).
- FAA L-824 dielectric & jacket: Type C (XLPE / PE, PVC or LSZH) vs Type B (EPR / CPE-XL-HD flexible elastomer).
- Conductor size and finish: 1×6 mm², 1×8 AWG or 1×6 AWG, bare vs tinned copper.
- Required continuous drum lengths (MOQ 50 m; typical airport drums 500–2,000 m) and lead time (7 to 45 working days).
Related selection resources
- Compare 5 kV XLPE Copper-Tape & Copper-Braid Airfield Lighting Cables
- Pair with 600 V Airport Pavement & FAA L-824 Secondary AGL Cables
- Explore 400 Hz Aircraft Ground Power Unit (GPU) Cables
- Explore Airport Apron Static Aircraft Grounding Cables
- Browse Complete Airport Ground Power & Airfield Lighting Catalog
FAA L-824 5 kV Brass-Tape & Unscreened AGL Cable FAQ
Why specify Brass-Tape Armoured FAA L-824 5 kV primary cable instead of copper-tape or unscreened cable?
A 100% overlapping helical brass tape (minimum 20% overlap) acts simultaneously as a grounded 5 kV metallic shield (18 kV AC tested) and a hard corrosion-resistant mechanical barrier that termites and burrowing rodents cannot chew through.
What is the difference between FAA L-824 Type C and Type B 5 kV Primary AGL cables?
Type C uses 90 °C cross-linked polyethylene (XLPE) insulation with a PE, PVC or LSZH outer jacket, whereas Type B uses flexible 90 °C EPR rubber insulation with a heavy-duty CPE-XL-HD or chloroprene jacket for rugged cold or high-flex airfield ducts.
How do the routine AC test voltages compare between Brass-Tape and Unscreened 5 kV FAA L-824 cables?
18 kV AC routine withstand test for Brass-Tape Armoured shielded 5 kV primary cables (ICEA S-93-639 / NEMA WC 74) and 13 kV AC routine withstand test for Unscreened 5 kV primary cables (ICEA S-96-659 / NEMA WC 71).
Are FAA L-824 5 kV Brass-Tape and Unscreened cables compatible with standard 1×8 AWG and 1×6 mm² L-823 connector kits?
Yes. Outer diameters span 12.4 to 14.0 mm (Brass-Tape) and 14.2 to 15.8 mm (Unscreened) across 1×6 mm², 1×8 AWG and 1×6 AWG, matching standard 5 kV FAA L-823 field-attached primary plug kits.
What is the MOQ and manufacturing lead time for FAA L-824 5 kV Brass-Tape AGL cables?
50 m minimum order per size and jacket build, custom-manufactured and 18 kV / 13 kV routine-tested in 7 to 45 working days.
FAA L-824 5 kV Brass-Tape & Unscreened Dimension Schedule
FAA L-824 Electrical, Anti-Termite & Test-Voltage Ratings
- 100% overlapping Brass-Tape anti-termite armour: Helically applied brass tape (minimum 20% overlap, 100% coverage) blocks burrowing rodents and termites in Middle East, Asian, African and tropical airfields
- Shielded Brass (18 kV test) & Unscreened (13 kV): Choose Brass-Tape Primary (12 × D bend, 12.4–14.0 mm OD) for shielded/armoured loops or Unscreened Primary (5 × D bend, 14.2–15.8 mm OD) for standard ducts
- FAA L-824 Type C (XLPE) & Type B (EPR) builds: Type C pairs 90 °C XLPE with PE, PVC or LSZH outer jackets; Type B pairs flexible 90 °C EPR with heavy CPE-XL-HD / chloroprene sheathing
- Extruded semiconductive 5 kV stress control: Every build incorporates an extruded semiconductive conductor layer (plus helical semicon tape on brass-screened builds) to prevent partial discharge
- 50 m MOQ in 1×6 mm², 1×8 AWG & 1×6 AWG: Bare or tinned IEC Class 2 / ASTM B8 Class B/C copper custom-manufactured in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 5 kV AC primary airfield lighting loops (18 kV AC test for Brass-Tape Armoured; 13 kV AC test for Unscreened) |
| Armour and screening architecture | 100% coverage (min 20% overlap) helical brass tape over semicon tape (Armoured) or non-shielded primary (Unscreened) |
| Insulation and jacket options | FAA L-824 Type C (XLPE / PE, PVC or LSZH) and Type B (EPR / CPE-XL-HD or chloroprene elastomer) |
| Operating temperature range | -25 °C to +90 °C continuous conductor operating temperature across burial and conduit service |
| Minimum bending radius | 12 × D for Brass-Tape Armoured 5 kV primary; 5 × D for Unscreened 5 kV primary builds |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary AGL Schedule
| Model & Size | Primary AGL Build | AC Test Voltage | Nominal OD (mm) | Approx. Weight (kg/km) | Max DC R @20 °C (Ω/km) | Current @45 °C (A) | Next step |
|---|---|---|---|---|---|---|---|
| FAA L-824 Brass Type C 1×6 mm² (PE) | Cl.2 / XLPE / Brass Tape / PE | 18 kV | 12.4 | 187 | 3.08 | 52 | Request this size |
| FAA L-824 Brass Type C 1×6 mm² (PVC) | Cl.2 / XLPE / Brass Tape / PVC | 18 kV | 12.4 | 212 | 3.08 | 52 | Request this size |
| FAA L-824 Brass Type C 1×8 AWG (PE) | ASTM B / XLPE / Brass Tape / PE | 18 kV | 13.0 | 220 | 2.10 | 64 | Request this size |
| FAA L-824 Brass Type C 1×8 AWG (PVC) | ASTM B / XLPE / Brass Tape / PVC | 18 kV | 13.0 | 247 | 2.10 | 64 | Request this size |
| FAA L-824 Brass Type C 1×6 AWG (PE) | ASTM B / XLPE / Brass Tape / PE | 18 kV | 14.0 | 282 | 1.33 | 85 | Request this size |
| FAA L-824 Brass Type C 1×6 AWG (PVC) | ASTM B / XLPE / Brass Tape / PVC | 18 kV | 14.0 | 311 | 1.33 | 85 | Request this size |
| FAA L-824 Brass Type B 1×6 mm² (CPE) | Cl.2 / EPR / Brass Tape / CPE | 18 kV | 12.4 | 225 | 3.08 | 52 | Request this size |
| FAA L-824 Brass Type B 1×8 AWG (CPE) | ASTM B / EPR / Brass Tape / CPE | 18 kV | 13.0 | 262 | 2.10 | 64 | Request this size |
| FAA L-824 Brass Type B 1×6 AWG (CPE) | ASTM B / EPR / Brass Tape / CPE | 18 kV | 14.0 | 329 | 1.33 | 85 | Request this size |
| FAA L-824 Unscreened Type C 1×6 mm² | Cl.2 / Semicon / XLPE / PE | 13 kV | 14.2 | 196 | 3.08 | 52 | Request this size |
| FAA L-824 Unscreened Type C 1×8 AWG | ASTM B / Semicon / XLPE / PE | 13 kV | 14.8 | 230 | 2.10 | 64 | Request this size |
| FAA L-824 Unscreened Type C 1×6 AWG | ASTM B / Semicon / XLPE / PE | 13 kV | 15.8 | 291 | 1.33 | 85 | Request this size |
Both bare (BCL2 / BAWGB) and tinned copper (TCL2 / TAWGB) conductors, halogen-free (LSZH) jackets and flexible Type B Unscreened EPR/CPE constructions are manufactured across 1×6 mm², 1×8 AWG and 1×6 AWG (MOQ 50 m per build; routine 18 kV / 13 kV AC withstand testing included).
ASCII part references for BOM and ERP entry: L824-5KV-BRT-C-1x6-PE, L824-5KV-BRT-C-1x6-PVC, L824-5KV-BRT-C-8AWG-PE, L824-5KV-BRT-C-8AWG-PVC, L824-5KV-BRT-C-6AWG-PE, L824-5KV-BRT-C-6AWG-PVC, L824-5KV-BRT-B-1x6-CPE, L824-5KV-BRT-B-8AWG-CPE, L824-5KV-BRT-B-6AWG-CPE, L824-5KV-UNSCR-C-1x6, L824-5KV-UNSCR-C-8AWG, L824-5KV-UNSCR-C-6AWG.
FAA AC 150/5345-7F, NEMA WC 74 & ICEA S-93-639 Standards
| Standard or specification | Application |
|---|---|
| FAA AC 150/5345-7F (L-824 Type C & Type B) | Federal Aviation Administration design specification for 5 kV underground primary airfield lighting cables. |
| ICEA S-93-639 / NEMA WC 74 & ICEA S-96-659 / NEMA WC 71 | 5 kV shielded (brass-tape, 18 kV test) and non-shielded (13 kV test) primary power-cable reference. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing quality and 18 kV routine HV test records
FAA AC 150/5345-7F — Specification for L-824 Underground Airfield Lighting Cable
NEMA WC 74 / ICEA S-93-639 — 5 kV to 46 kV Shielded Power Cable
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Airport Pavement & Secondary AGL Cable 600 V (PVC/Polyamide Saw-Cut & FAA L-824 Type B/C)
A related cable option for a different application or duty profile.
View product5 kV XLPE Airfield Lighting Cable — Tape and Braid Screens
A related cable option for a different application or duty profile.
View product400Hz Aircraft Ground Power Cable for Airport GPU Systems
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.