FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary Airfield Lighting Cable (Type C & Type B)

FAA L-824 5 kV Brass-Tape Armoured (18 kV AC test, ICEA S-93-639 / NEMA WC 74) and Unscreened (13 kV AC test, NEMA WC 71 / ICEA S-96-659) Primary Airfield Lighting Cables power constant-current 6.6 A / 20 A airport runway series loops across termite-, rodent- and moisture-prone soils. Supplied in both FAA L-824 Type C (XLPE / PE, PVC or LSZH) and flexible Type B (EPR / CPE-XL-HD) across 1×6 mm², 1×8 AWG and 1×6 AWG with extruded semiconductive conductor screens and -25 °C to +90 °C ratings.

Product information
SKU
TF-AGL-5KV-BRASS
Brand
TEBAOFLEX
Product overview

FAA L-824 5 kV Brass-Tape Armoured and Unscreened Primary Airfield Lighting (AGL) Cables carry constant-current 6.6 A and 20 A series power from airport electrical vault Constant Current Regulators (CCRs) around kilometer-long runway, approach and taxiway primary loops under FAA AC 150/5345-7F, ICEA S-93-639 (NEMA WC 74) and ICEA S-96-659 (NEMA WC 71).

Across tropical, desert and coastal airports in the Middle East, Southeast Asia, Africa, Australia and Latin America, direct-buried and shallow-duct 5 kV runway series loops frequently suffer costly earth-fault blackouts caused by subterranean termites and rodents chewing through soft polymer jackets—or soil-moisture induced treeing. Our Brass-Tape Armoured FAA L-824 Type C (XLPE) and Type B (EPR) builds wrap a hard, corrosion-resistant helically overlapped brass tape (minimum 20% overlap, 100% coverage) directly over the semiconductive screen, creating a dual-purpose metallic fault shield and impenetrable mechanical anti-termite/rodent barrier tested at 18 kV AC. Where metallic screening is not specified on protected PVC/HDPE ducts, our Unscreened 5 kV FAA L-824 Type C and Type B constructions offer a streamlined 13 kV-tested build with an ultra-compact 5 × D bending radius.

Choose this page for 5 kV Brass-Tape Armoured (anti-termite/rodent) and Unscreened FAA L-824 Primary AGL loops; choose our existing 5 kV XLPE Copper-Tape & Copper-Braid Airfield Lighting Cable where standard copper screening is specified, and pair with our 600 V Airport Pavement & Secondary AGL series for the transformer-to-light leg. Minimum order 50 m; lead time 7 to 45 working days.

Explore the 400 Hz airport ground power cable range for related configurations.

Construction

FAA L-824 5 kV Brass-Tape Armoured & Unscreened Construction

5 kV airfield primary loop architecture combining Class 2 / ASTM B8 copper, extruded semiconductive conductor screen, 90 °C XLPE (Type C) or EPR (Type B) insulation, optional helical brass-tape shield/armour and PE/PVC/CPE outer jacket.

Clean 2D technical cross-section of single-core FAA L-824 5 kV Brass-Tape Armoured primary airfield cable showing matte black outer jacket, golden brass tape anti-termite ring, thin black semiconductive layer, thick translucent XLPE dielectric, inner semicon ring and compacted copper center
Single-core 5 kV FAA L-824 Brass-Tape cross-section rated 18 kV AC routine test per ICEA S-93-639 / NEMA WC 74.
FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary Airfield Lighting Cable (Type C & Type B) construction
ComponentMaterial and construction
1. Stranded Annealed Bare or Tinned Copper Conductor1×6 mm² (IEC 60228 Class 2) or 1×8 AWG / 1×6 AWG (ASTM B8 Class B/C) engineered for long-run low-resistance 6.6 A / 20 A CCR series circuits.
2. Extruded Semiconductive Conductor ScreenSmooth bonded semiconductive shield eliminates strand-surface electric field spikes at 5 kV primary operating voltage.
3. 90 °C XLPE (Type C) or EPR (Type B) Primary InsulationHigh-dielectric cross-linked polyethylene (Type C) or flexible ethylene-propylene rubber (Type B) rated -25 °C to +90 °C continuous.
4. Semiconductive Tape + 100% Overlapping Brass Tape (Armoured Variant)Helically applied semiconductive tape plus minimum 20% overlap / 100% coverage brass tape provides metallic screening and impenetrable termite/rodent armour (omitted on Unscreened builds).
5. PE, PVC, LSZH (Type C) or CPE-XL-HD / Neoprene (Type B) JacketUV-, moisture-, soil-chemical- and hydrocarbon-resistant outer jacket matching NEMA WC 74 / NEMA WC 71 airfield burial conditions.

FAA L-824 Type C / Type B & Brass-Tape Code Breakdown

  • FAA L-824: Federal Aviation Administration 5 kV underground primary airfield lighting cable designation
  • Type C / Type B: Type C = 90 °C XLPE insulation (PE/PVC/LSZH jacket); Type B = flexible 90 °C EPR insulation (CPE/rubber)
  • EXSC / SCT: Extruded semiconductive conductor screen (EXSC) and helical semiconductive insulation tape (SCT)
  • BRT: 100% coverage (minimum 20% overlap) helical Brass Tape shield and anti-termite/rodent mechanical armour
  • Unscreened: Non-shielded 5 kV primary option (13 kV AC test, tight 5 × D bend) per NEMA WC 71 / ICEA S-96-659
Applications

FAA L-824 Runway, Taxiway & Termite-Zone Airfield Applications

Engineered for 5 kV constant-current primary series loops feeding runway, taxiway, approach and apron isolation transformers worldwide.

International airport runway shoulder trench installation showing large wooden cable reels paying out matte black 5 kV FAA L-824 Brass-Tape Armoured primary airfield lighting cables into underground conduit ducts alongside runway lights
Airfield perimeter runway lighting trench deploying 5 kV Brass-Tape Armoured and Unscreened FAA L-824 primary series loop cables.
  • Direct-buried and shallow-duct 5 kV runway lighting rings in termite- and rodent-active tropical, desert and coastal airports (Brass-Tape Armoured).
  • Constant Current Regulator (CCR) primary series loops feeding 6.6 A and 20 A airfield isolation transformers across civil and military airbases.
  • Conduit-routed unscreened 5 kV FAA L-824 Type C (XLPE) and flexible Type B (EPR) airfield primary circuits requiring tight 5 × D pit turns.
  • Runway expansion and LED AGL modernization projects specifying dual metric (1×6 mm²) or imperial (1×8 AWG, 1×6 AWG) primary loops.

FAA L-824 5 kV Brass-Tape vs Unscreened vs Copper-Tape AGL

FAA L-824 5 kV Brass-Tape Armoured vs Unscreened vs Copper-Tape/Braid vs 600 V Secondary AGL
Airfield Cable VariantMetallic Screen / ArmourTest Voltage & BendBest Airport Soil / Spec Condition
FAA L-824 Brass-Tape (this page)100% overlapping Brass Tape18 kV AC · 12 × DTermite/rodent-prone soil, direct burial & harsh tropical airfields
FAA L-824 Unscreened (this page)None (semicon+XLPE/EPR)13 kV AC · 5 × DProtected PVC/HDPE ducts requiring tight pit bending & easy splicing
5 kV Copper Tape / Braid AGLBare copper tape or braid18 kV AC · 12 × DStandard shielded runway loops near ILS, radar & NAVAIDS
Airport Pavement / Sec. 600 VNone (PVC/PA or XLPE/EPR)2 kV AC · 5 × D600 V transformer-to-light saw-cut slots & fixture feeds

Always bond brass-tape metallic shields per airport grounding rules at vault terminations and verify L-823 primary plug kit OD range (12.4–15.8 mm).

FAA L-824 5 kV Brass-Tape Primary AGL Cable RFQ Checklist

  • Primary architecture: 5 kV Brass-Tape Armoured (18 kV test) vs 5 kV Unscreened (13 kV test).
  • FAA L-824 dielectric & jacket: Type C (XLPE / PE, PVC or LSZH) vs Type B (EPR / CPE-XL-HD flexible elastomer).
  • Conductor size and finish: 1×6 mm², 1×8 AWG or 1×6 AWG, bare vs tinned copper.
  • Required continuous drum lengths (MOQ 50 m; typical airport drums 500–2,000 m) and lead time (7 to 45 working days).

Related selection resources

FAA L-824 5 kV Brass-Tape & Unscreened AGL Cable FAQ

Why specify Brass-Tape Armoured FAA L-824 5 kV primary cable instead of copper-tape or unscreened cable?

A 100% overlapping helical brass tape (minimum 20% overlap) acts simultaneously as a grounded 5 kV metallic shield (18 kV AC tested) and a hard corrosion-resistant mechanical barrier that termites and burrowing rodents cannot chew through.

What is the difference between FAA L-824 Type C and Type B 5 kV Primary AGL cables?

Type C uses 90 °C cross-linked polyethylene (XLPE) insulation with a PE, PVC or LSZH outer jacket, whereas Type B uses flexible 90 °C EPR rubber insulation with a heavy-duty CPE-XL-HD or chloroprene jacket for rugged cold or high-flex airfield ducts.

How do the routine AC test voltages compare between Brass-Tape and Unscreened 5 kV FAA L-824 cables?

18 kV AC routine withstand test for Brass-Tape Armoured shielded 5 kV primary cables (ICEA S-93-639 / NEMA WC 74) and 13 kV AC routine withstand test for Unscreened 5 kV primary cables (ICEA S-96-659 / NEMA WC 71).

Are FAA L-824 5 kV Brass-Tape and Unscreened cables compatible with standard 1×8 AWG and 1×6 mm² L-823 connector kits?

Yes. Outer diameters span 12.4 to 14.0 mm (Brass-Tape) and 14.2 to 15.8 mm (Unscreened) across 1×6 mm², 1×8 AWG and 1×6 AWG, matching standard 5 kV FAA L-823 field-attached primary plug kits.

What is the MOQ and manufacturing lead time for FAA L-824 5 kV Brass-Tape AGL cables?

50 m minimum order per size and jacket build, custom-manufactured and 18 kV / 13 kV routine-tested in 7 to 45 working days.

Specifications

FAA L-824 5 kV Brass-Tape & Unscreened Dimension Schedule

FAA L-824 Electrical, Anti-Termite & Test-Voltage Ratings

  • 100% overlapping Brass-Tape anti-termite armour: Helically applied brass tape (minimum 20% overlap, 100% coverage) blocks burrowing rodents and termites in Middle East, Asian, African and tropical airfields
  • Shielded Brass (18 kV test) & Unscreened (13 kV): Choose Brass-Tape Primary (12 × D bend, 12.4–14.0 mm OD) for shielded/armoured loops or Unscreened Primary (5 × D bend, 14.2–15.8 mm OD) for standard ducts
  • FAA L-824 Type C (XLPE) & Type B (EPR) builds: Type C pairs 90 °C XLPE with PE, PVC or LSZH outer jackets; Type B pairs flexible 90 °C EPR with heavy CPE-XL-HD / chloroprene sheathing
  • Extruded semiconductive 5 kV stress control: Every build incorporates an extruded semiconductive conductor layer (plus helical semicon tape on brass-screened builds) to prevent partial discharge
  • 50 m MOQ in 1×6 mm², 1×8 AWG & 1×6 AWG: Bare or tinned IEC Class 2 / ASTM B8 Class B/C copper custom-manufactured in 7 to 45 working days
FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary Airfield Lighting Cable (Type C & Type B) technical data
ParameterValue
Rated voltage5 kV AC primary airfield lighting loops (18 kV AC test for Brass-Tape Armoured; 13 kV AC test for Unscreened)
Armour and screening architecture100% coverage (min 20% overlap) helical brass tape over semicon tape (Armoured) or non-shielded primary (Unscreened)
Insulation and jacket optionsFAA L-824 Type C (XLPE / PE, PVC or LSZH) and Type B (EPR / CPE-XL-HD or chloroprene elastomer)
Operating temperature range-25 °C to +90 °C continuous conductor operating temperature across burial and conduit service
Minimum bending radius12 × D for Brass-Tape Armoured 5 kV primary; 5 × D for Unscreened 5 kV primary builds
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary AGL Schedule

FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary AGL Cable Exact Schedule
Model & SizePrimary AGL BuildAC Test VoltageNominal OD (mm)Approx. Weight (kg/km)Max DC R @20 °C (Ω/km)Current @45 °C (A)Next step
FAA L-824 Brass Type C 1×6 mm² (PE)Cl.2 / XLPE / Brass Tape / PE18 kV12.41873.0852Request this size
FAA L-824 Brass Type C 1×6 mm² (PVC)Cl.2 / XLPE / Brass Tape / PVC18 kV12.42123.0852Request this size
FAA L-824 Brass Type C 1×8 AWG (PE)ASTM B / XLPE / Brass Tape / PE18 kV13.02202.1064Request this size
FAA L-824 Brass Type C 1×8 AWG (PVC)ASTM B / XLPE / Brass Tape / PVC18 kV13.02472.1064Request this size
FAA L-824 Brass Type C 1×6 AWG (PE)ASTM B / XLPE / Brass Tape / PE18 kV14.02821.3385Request this size
FAA L-824 Brass Type C 1×6 AWG (PVC)ASTM B / XLPE / Brass Tape / PVC18 kV14.03111.3385Request this size
FAA L-824 Brass Type B 1×6 mm² (CPE)Cl.2 / EPR / Brass Tape / CPE18 kV12.42253.0852Request this size
FAA L-824 Brass Type B 1×8 AWG (CPE)ASTM B / EPR / Brass Tape / CPE18 kV13.02622.1064Request this size
FAA L-824 Brass Type B 1×6 AWG (CPE)ASTM B / EPR / Brass Tape / CPE18 kV14.03291.3385Request this size
FAA L-824 Unscreened Type C 1×6 mm²Cl.2 / Semicon / XLPE / PE13 kV14.21963.0852Request this size
FAA L-824 Unscreened Type C 1×8 AWGASTM B / Semicon / XLPE / PE13 kV14.82302.1064Request this size
FAA L-824 Unscreened Type C 1×6 AWGASTM B / Semicon / XLPE / PE13 kV15.82911.3385Request this size

Both bare (BCL2 / BAWGB) and tinned copper (TCL2 / TAWGB) conductors, halogen-free (LSZH) jackets and flexible Type B Unscreened EPR/CPE constructions are manufactured across 1×6 mm², 1×8 AWG and 1×6 AWG (MOQ 50 m per build; routine 18 kV / 13 kV AC withstand testing included).

ASCII part references for BOM and ERP entry: L824-5KV-BRT-C-1x6-PE, L824-5KV-BRT-C-1x6-PVC, L824-5KV-BRT-C-8AWG-PE, L824-5KV-BRT-C-8AWG-PVC, L824-5KV-BRT-C-6AWG-PE, L824-5KV-BRT-C-6AWG-PVC, L824-5KV-BRT-B-1x6-CPE, L824-5KV-BRT-B-8AWG-CPE, L824-5KV-BRT-B-6AWG-CPE, L824-5KV-UNSCR-C-1x6, L824-5KV-UNSCR-C-8AWG, L824-5KV-UNSCR-C-6AWG.

Standards

FAA AC 150/5345-7F, NEMA WC 74 & ICEA S-93-639 Standards

FAA L-824 5 kV Brass-Tape Armoured & Unscreened Primary Airfield Lighting Cable (Type C & Type B) standards and test references
Standard or specificationApplication
FAA AC 150/5345-7F (L-824 Type C & Type B)Federal Aviation Administration design specification for 5 kV underground primary airfield lighting cables.
ICEA S-93-639 / NEMA WC 74 & ICEA S-96-659 / NEMA WC 715 kV shielded (brass-tape, 18 kV test) and non-shielded (13 kV test) primary power-cable reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing quality and 18 kV routine HV test records

FAA AC 150/5345-7F — Specification for L-824 Underground Airfield Lighting Cable

NEMA WC 74 / ICEA S-93-639 — 5 kV to 46 kV Shielded Power Cable

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.