AS/NZS 1972 XLPE Mine Feeder Cable, 11 and 22 kV
Three-core XLPE mine feeder cable for fixed distribution at 6.35/11 or 12.7/22 kV, with individual copper-wire screens, PVC inner sheath, galvanized steel-wire armour and PVC outer sheath. Select the voltage and a complete dimensional schedule for the required conductor size.
AS/NZS 1972 XLPE mine feeder cable supplies fixed mine distribution circuits at 6.35/11 or 12.7/22 kV. Three copper power cores are individually insulated and copper-wire screened, then assembled beneath a PVC inner sheath, galvanized steel-wire armour and a PVC outer sheath. This page covers stationary feeder routes where the circuit specification calls for that screened, armoured construction.
Choose the full voltage designation before selecting conductor area. The 6.35/11 kV construction uses 3.4 mm nominal XLPE insulation, while the 12.7/22 kV construction uses 5.5 mm. The discrete sizes and dimensional schedules remain separate because an identical conductor area can have a different overall diameter and mass. Use the selected schedule when checking cable entries, cleats, drums and termination dimensions.
The copper-wire screens and steel-wire armour occupy different positions and perform different functions. Specify the required screen-earth arrangement, bonding and fault-duty calculations with the installation design. These three-core feeders contain no separate pilot or ground-check core. Where the project specifies MP-GC, compare 15 kV XLPE/PVC MP-GC feeder cable or EPR/CPE MP-GC feeder cable, and use that construction’s own grounding arrangement. A moving machine supply requires a cable selected for its actual trailing or reeling duty.
For a quotation, identify the voltage, conductor area, dimensional schedule, route, termination requirements and total length. TEBAOFLEX supplies this XLPE feeder family from a 50 m minimum order quantity, with a manufacturing lead time of 7–45 working days. Include the applicable standard edition and project acceptance documents so the quoted construction can be matched to the installation.
Explore the mining and tunneling cable range for related configurations.
Construction
The three round power cores are individually copper-wire screened and laid up into a round armoured cable. The main image represents the 6.35/11 kV, 3 × 95 mm² configuration from dimensional schedule 2.
| Component | Material and construction |
|---|---|
| Power conductors | Three stranded plain-copper conductors; schedule 2 specifies circular compressed Class 2 annealed copper. |
| Conductor screen | Semiconducting layer over each conductor in the detailed schedule 2 construction. |
| Insulation | XLPE: nominal 3.4 mm at 6.35/11 kV and 5.5 mm at 12.7/22 kV. |
| Insulation screen | Semiconducting layer outside the XLPE in the detailed schedule 2 construction. |
| Individual metallic screens | Copper wires around each insulated phase; wire count/diameter and, for schedule 1, screen area are tabulated. |
| Assembly and inner sheath | Three screened cores with interstitial filler beneath a common PVC inner sheath. |
| Armour | One common layer of galvanized round steel wires. |
| Outer sheath | PVC; schedule 1 cites AS/NZS 1429.1. |
Applications
Use this construction for fixed high-voltage feeder routes in mines where the specified voltage, earthing system and armoured installation match the selected schedule.
- Stationary mine power-distribution feeders between electrical distribution points.
- Replacement of an identified AS/NZS 1972 XLPE feeder after matching the complete voltage designation, conductor size, screen and termination dimensions.
- Projects specifying individually copper-wire-screened three-core feeders with common steel-wire armour.
- Fixed routes designed with cable support, bending, pulling and bonding requirements appropriate to the ordered construction.
For route and construction selection, see the medium-voltage mining cable selection guide.
For fixed low-voltage distribution within the same standard family, compare Type A and Type B 1.1/1.1 kV mine feeder cable. Match the voltage, insulation and pilot arrangement to the circuit.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage U₀/U | 6.35/11 kV or 12.7/22 kV |
| Power-core count | Three |
| Insulation | XLPE |
| Metallic protection | Individual copper-wire screens; common galvanized steel-wire armour |
| Installation | Fixed mine feeder |
| Schedule 1 — 6.35/11 kV sizes | 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 and 400 mm² |
| Schedule 1 — 12.7/22 kV sizes | 35, 50, 70, 95, 120, 150, 185, 240, 300 and 400 mm² |
| Schedule 2 — 6.35/11 kV sizes | 35, 50, 70, 95, 120, 150, 185, 240 and 300 mm² |
| Schedule 2 — 12.7/22 kV sizes | 70, 95, 120, 150, 185, 240 and 300 mm² |
| Minimum order quantity | 50 m |
| Manufacturing lead time | 7–45 working days |
| Model and configuration | Nominal XLPE insulation | Listed sizes | Selection requirement |
|---|---|---|---|
| XLPE mine feeder 6.35/11 kV, three cores | 3.4 mm | Schedule 1: 16–400 mm²; schedule 2: 35–300 mm², discrete sizes below | Match one complete dimensional schedule. |
| XLPE mine feeder 12.7/22 kV, three cores | 5.5 mm | Schedule 1: 35–400 mm²; schedule 2: 70–300 mm², discrete sizes below | Do not transfer the 11 kV dimensions to the 22 kV construction. |
| Model and configuration | Conductor diameter (mm) | XLPE (mm) | Armour wire (mm) | Outer sheath (mm) | Nominal OD (mm) | Nominal mass (kg/100 m) |
|---|---|---|---|---|---|---|
| XLPE mine feeder 6.35/11 kV 3 × 16 mm² | 4.8 | 3.4 | 2.00 | 2.4 | 46.6 | 330 |
| XLPE mine feeder 6.35/11 kV 3 × 25 mm² | 5.8 | 3.4 | 2.50 | 2.5 | 50.1 | 415 |
| XLPE mine feeder 6.35/11 kV 3 × 35 mm² | 6.8 | 3.4 | 2.50 | 2.6 | 52.8 | 475 |
| XLPE mine feeder 6.35/11 kV 3 × 50 mm² | 8.0 | 3.4 | 2.50 | 2.7 | 55.7 | 540 |
| XLPE mine feeder 6.35/11 kV 3 × 70 mm² | 9.6 | 3.4 | 2.50 | 2.8 | 59.6 | 645 |
| XLPE mine feeder 6.35/11 kV 3 × 95 mm² | 11.5 | 3.4 | 2.50 | 2.9 | 63.9 | 775 |
| XLPE mine feeder 6.35/11 kV 3 × 120 mm² | 13.1 | 3.4 | 2.50 | 3.1 | 67.9 | 905 |
| XLPE mine feeder 6.35/11 kV 3 × 150 mm² | 14.5 | 3.4 | 2.50 | 3.2 | 71.5 | 1030 |
| XLPE mine feeder 6.35/11 kV 3 × 185 mm² | 16.1 | 3.4 | 3.15 | 3.3 | 78.6 | 1280 |
| XLPE mine feeder 6.35/11 kV 3 × 240 mm² | 18.5 | 3.4 | 3.15 | 3.5 | 84.7 | 1550 |
| XLPE mine feeder 6.35/11 kV 3 × 300 mm² | 20.7 | 3.4 | 3.15 | 3.7 | 90.4 | 1820 |
| XLPE mine feeder 6.35/11 kV 3 × 400 mm² | 23.6 | 3.4 | 3.15 | 4.0 | 97.9 | 2230 |
| Model and configuration | Screen wires (number / mm) | Screen area per core (mm²) |
|---|---|---|
| XLPE mine feeder 6.35/11 kV 3 × 16 mm² | 10/0.85 | 5.7 |
| XLPE mine feeder 6.35/11 kV 3 × 25 mm² | 10/0.85 | 5.7 |
| XLPE mine feeder 6.35/11 kV 3 × 35 mm² | 11/0.85 | 6.2 |
| XLPE mine feeder 6.35/11 kV 3 × 50 mm² | 15/0.85 | 8.5 |
| XLPE mine feeder 6.35/11 kV 3 × 70 mm² | 21/0.85 | 11.9 |
| XLPE mine feeder 6.35/11 kV 3 × 95 mm² | 29/0.85 | 16.5 |
| XLPE mine feeder 6.35/11 kV 3 × 120 mm² | 36/0.85 | 20.4 |
| XLPE mine feeder 6.35/11 kV 3 × 150 mm² | 44/0.85 | 25.0 |
| XLPE mine feeder 6.35/11 kV 3 × 185 mm² | 22/1.35 | 31.5 |
| XLPE mine feeder 6.35/11 kV 3 × 240 mm² | 29/1.35 | 41.5 |
| XLPE mine feeder 6.35/11 kV 3 × 300 mm² | 37/1.35 | 53.0 |
| XLPE mine feeder 6.35/11 kV 3 × 400 mm² | 47/1.35 | 67.3 |
| Model and configuration | Conductor diameter (mm) | XLPE (mm) | Armour wire (mm) | Outer sheath (mm) | Nominal OD (mm) | Nominal mass (kg/100 m) |
|---|---|---|---|---|---|---|
| XLPE mine feeder 12.7/22 kV 3 × 35 mm² | 6.8 | 5.5 | 2.5 | 2.9 | 63.2 | 600 |
| XLPE mine feeder 12.7/22 kV 3 × 50 mm² | 8.0 | 5.5 | 2.5 | 3.0 | 66.0 | 665 |
| XLPE mine feeder 12.7/22 kV 3 × 70 mm² | 9.6 | 5.5 | 2.5 | 3.1 | 69.9 | 775 |
| XLPE mine feeder 12.7/22 kV 3 × 95 mm² | 11.5 | 5.5 | 2.5 | 3.3 | 74.4 | 920 |
| XLPE mine feeder 12.7/22 kV 3 × 120 mm² | 13.1 | 5.5 | 3.15 | 3.4 | 79.5 | 1140 |
| XLPE mine feeder 12.7/22 kV 3 × 150 mm² | 14.5 | 5.5 | 3.15 | 3.5 | 83.1 | 1280 |
| XLPE mine feeder 12.7/22 kV 3 × 185 mm² | 16.1 | 5.5 | 3.15 | 3.7 | 89.1 | 1450 |
| XLPE mine feeder 12.7/22 kV 3 × 240 mm² | 18.5 | 5.5 | 3.15 | 3.9 | 95.0 | 1720 |
| XLPE mine feeder 12.7/22 kV 3 × 300 mm² | 20.7 | 5.5 | 3.15 | 4.1 | 101.1 | 2010 |
| XLPE mine feeder 12.7/22 kV 3 × 400 mm² | 23.6 | 5.5 | 3.15 | 4.3 | 108.2 | 2420 |
| Model and configuration | Screen wires (number / mm) | Screen area per core (mm²) |
|---|---|---|
| XLPE mine feeder 12.7/22 kV 3 × 35 mm² | 14/0.85 | 7.9 |
| XLPE mine feeder 12.7/22 kV 3 × 50 mm² | 15/0.85 | 8.5 |
| XLPE mine feeder 12.7/22 kV 3 × 70 mm² | 21/0.85 | 11.9 |
| XLPE mine feeder 12.7/22 kV 3 × 95 mm² | 29/0.85 | 16.5 |
| XLPE mine feeder 12.7/22 kV 3 × 120 mm² | 36/0.85 | 20.4 |
| XLPE mine feeder 12.7/22 kV 3 × 150 mm² | 44/0.85 | 25.0 |
| XLPE mine feeder 12.7/22 kV 3 × 185 mm² | 22/1.35 | 31.5 |
| XLPE mine feeder 12.7/22 kV 3 × 240 mm² | 29/1.35 | 41.5 |
| XLPE mine feeder 12.7/22 kV 3 × 300 mm² | 37/1.35 | 53.0 |
| XLPE mine feeder 12.7/22 kV 3 × 400 mm² | 47/1.35 | 67.3 |
| Model and configuration | Conductor diameter (mm) | XLPE (mm) | Armour wire (mm) | Outer sheath (mm) | Approx. OD (mm) | Approx. maximum mass (kg/100 m) |
|---|---|---|---|---|---|---|
| XLPE mine feeder 6.35/11 kV 3 × 35 mm² | 6.8 | 3.4 | 2.50 | 2.6 | 53 | 484 |
| XLPE mine feeder 6.35/11 kV 3 × 50 mm² | 8.0 | 3.4 | 2.50 | 2.7 | 55.6 | 549 |
| XLPE mine feeder 6.35/11 kV 3 × 70 mm² | 9.6 | 3.4 | 2.50 | 2.8 | 59.4 | 639 |
| XLPE mine feeder 6.35/11 kV 3 × 95 mm² | 11.5 | 3.4 | 2.50 | 2.9 | 63.5 | 745 |
| XLPE mine feeder 6.35/11 kV 3 × 120 mm² | 13.1 | 3.4 | 2.50 | 3.1 | 66.9 | 882 |
| XLPE mine feeder 6.35/11 kV 3 × 150 mm² | 14.5 | 3.4 | 2.50 | 3.2 | 70.3 | 998 |
| XLPE mine feeder 6.35/11 kV 3 × 185 mm² | 16.1 | 3.4 | 3.15 | 3.3 | 75.9 | 1208 |
| XLPE mine feeder 6.35/11 kV 3 × 240 mm² | 18.5 | 3.4 | 3.15 | 3.5 | 81.7 | 1423 |
| XLPE mine feeder 6.35/11 kV 3 × 300 mm² | 20.7 | 3.4 | 3.15 | 3.7 | 86.9 | 1648 |
| Model and configuration | Screen wires (number / mm) | Max. DC resistance at 20°C (Ω/km) | Max. AC resistance at 90°C (Ω/km) |
|---|---|---|---|
| XLPE mine feeder 6.35/11 kV 3 × 35 mm² | 11/0.85 | 0.524 | 0.668 |
| XLPE mine feeder 6.35/11 kV 3 × 50 mm² | 15/0.85 | 0.387 | 0.494 |
| XLPE mine feeder 6.35/11 kV 3 × 70 mm² | 21/0.85 | 0.268 | 0.342 |
| XLPE mine feeder 6.35/11 kV 3 × 95 mm² | 29/0.85 | 0.193 | 0.247 |
| XLPE mine feeder 6.35/11 kV 3 × 120 mm² | 36/0.85 | 0.153 | 0.196 |
| XLPE mine feeder 6.35/11 kV 3 × 150 mm² | 44/0.85 | 0.124 | 0.161 |
| XLPE mine feeder 6.35/11 kV 3 × 185 mm² | 22/1.35 | 0.0991 | 0.129 |
| XLPE mine feeder 6.35/11 kV 3 × 240 mm² | 29/1.35 | 0.0754 | 0.0988 |
| XLPE mine feeder 6.35/11 kV 3 × 300 mm² | 37/1.35 | 0.0601 | 0.0798 |
| Model and configuration | Conductor diameter (mm) | XLPE (mm) | Armour wire (mm) | Outer sheath (mm) | Approx. OD (mm) | Approx. maximum mass (kg/100 m) |
|---|---|---|---|---|---|---|
| XLPE mine feeder 12.7/22 kV 3 × 70 mm² | 9.6 | 5.5 | 2.5 | 3.1 | 69.5 | 768 |
| XLPE mine feeder 12.7/22 kV 3 × 95 mm² | 11.5 | 5.5 | 2.5 | 3.3 | 73.6 | 879 |
| XLPE mine feeder 12.7/22 kV 3 × 120 mm² | 13.1 | 5.5 | 3.15 | 3.4 | 77 | 1021 |
| XLPE mine feeder 12.7/22 kV 3 × 150 mm² | 14.5 | 5.5 | 3.15 | 3.5 | 80.4 | 1139 |
| XLPE mine feeder 12.7/22 kV 3 × 185 mm² | 16.1 | 5.5 | 3.15 | 3.7 | 86.2 | 1375 |
| XLPE mine feeder 12.7/22 kV 3 × 240 mm² | 18.5 | 5.5 | 3.15 | 3.9 | 92 | 1597 |
| XLPE mine feeder 12.7/22 kV 3 × 300 mm² | 20.7 | 5.5 | 3.15 | 4.1 | 97.1 | 1823 |
| Model and configuration | Screen wires (number / mm) | Max. DC resistance at 20°C (Ω/km) | Max. AC resistance at 90°C (Ω/km) |
|---|---|---|---|
| XLPE mine feeder 12.7/22 kV 3 × 70 mm² | 21/0.85 | 0.268 | 0.344 |
| XLPE mine feeder 12.7/22 kV 3 × 95 mm² | 29/0.85 | 0.193 | 0.248 |
| XLPE mine feeder 12.7/22 kV 3 × 120 mm² | 36/0.85 | 0.153 | 0.197 |
| XLPE mine feeder 12.7/22 kV 3 × 150 mm² | 44/0.85 | 0.124 | 0.160 |
| XLPE mine feeder 12.7/22 kV 3 × 185 mm² | 22/1.35 | 0.0991 | 0.128 |
| XLPE mine feeder 12.7/22 kV 3 × 240 mm² | 29/1.35 | 0.0754 | 0.0985 |
| XLPE mine feeder 12.7/22 kV 3 × 300 mm² | 37/1.35 | 0.0601 | 0.0795 |
Schedules 1 and 2 are separate reference constructions. Choose one complete schedule for the quotation; do not combine a diameter, mass, screen or armour value from different schedules.
Mass is stated in kg/100 m, exactly as tabulated. Overall diameters and masses are reference values subject to the selected construction and manufacturing tolerances.
Screen-wire notation gives number of wires / individual wire diameter in mm. Schedule 1 screen area is for an individual core screen, not an additional power conductor.
DC resistance is tabulated at 20°C and AC resistance at 90°C for schedule 2. These reference temperatures do not by themselves establish installation ambient limits or a complete thermal rating.
Determine current-carrying capacity from the selected cable, ambient temperature, route, grouping, support and thermal conditions. No universal ampacity is assigned to this page.
Confirm the pulling arrangement, minimum bend radius, screen bonding and fault-current duty with the order-specific cable design. Steel-wire armour alone does not establish a self-supporting shaft length.
Standards
| Standard or specification | Application |
|---|---|
| AS/NZS 1972:2006 | Fixed mine-feeder construction reference, other than reeling and trailing cables. |
| AS/NZS 1125 | Copper conductor reference listed with dimensional schedule 1. |
| AS/NZS 3808 | Insulating and sheathing material reference listed with dimensional schedule 1. |
| AS/NZS 1429.1 | Polymeric-insulated cable reference cited for the schedule 1 outer-sheath construction. |
Official standards and approval references
AS/NZS 1972:2006 is the edition associated with these fixed-feeder constructions. The official 2026 review record identifies the 2006 designation; the review year is not a new cable-standard edition.
- Standards New Zealand — AS/NZS 1972:2006 official review record — Official record identifying the underground-coal-mine cable standard for constructions other than reeling and trailing cables.
Certifications and document support
Review our company certificates and document scopes when identifying the documentation required for the quoted construction.
State the required AS/NZS edition, voltage, conductor area, complete dimensional schedule, screen-earth arrangement and acceptance tests. Match any required product approval, test record and cable marking to that exact ordered construction; a standard citation or company management-system certificate has a different scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type MP-GC 15kV Mine Power Feeder Cable
A related cable option for a different application or duty profile.
View productType MP-GC EPR/CPE Mine Power Feeder Cable, 5–35 kV
A related cable option for a different application or duty profile.
View productType A and Type B 1.1/1.1 kV Mine Feeder Cable — AS/NZS 1972
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.