High Temperature Cables TEBAOFLEX

TF-BESS-DC 1.5 kV DC & 1.8/3 kV Short-Circuit-Proof High-Amp Power Cable for AI Data Center UPS & Utility BESS (16–400 mm²)

TF-BESS-DC is a halogen-free, low-smoke, short-circuit and earth-fault resistant single-core flexible power cable engineered for 1,500 V DC utility battery energy storage systems (BESS), AI data center UPS battery rooms, power conversion systems (PCS) and direct-burial DC feeders. Rated 1.5 kV DC continuous (1.8/3 kV AC short-circuit-proof dual-wall insulation, -40 °C to +120 °C conductor rating), TF-BESS-DC is manufactured in Class 5/6 tinned copper (16–400 mm²) and lightweight flexible aluminum (95–400 mm²) for low-loss high-amp power distribution.

Product information
SKU
TF-BESS-DC-1500V
Brand
TEBAOFLEX
Product overview

TF-BESS-DC 1.5 kV DC and 1.8/3 kV AC short-circuit-proof high-amp flexible power cables (16 mm² to 400 mm² tinned copper and 95 mm² to 400 mm² flexible aluminum, -40 °C to +120 °C conductor rating) deliver safe, low-loss DC and AC high-current distribution across AI data center UPS battery banks, containerized utility BESS racks, PCS inverters and backup generator switchboards.

Modern hyperscale AI data centers and 1,500 V DC megawatt-scale battery containers pack extreme fault-current energy inside densely routed bus trays and battery racks where conventional 70–90 °C PVC or single-wall XLPE cables overheat, propagate toxic acid smoke or fail under tight rack bends. TF-BESS-DC solves all three hazards using a dual-wall halogen-free cross-linked EPR/XLPO insulation-and-sheath system engineered for short-circuit and earth-fault protection (aligned with NSHXAFÖ 1.8/3 kV safety principles and 1,500 V DC continuous service), paired with ultra-clean low-smoke zero-halogen fire performance (IEC 60332-3-22, IEC 60754, IEC 61034) and direct-burial water/UV durability.

Specify TF-BESS-DC for 1,500 V DC battery-rack-to-combiner strings, UPS-to-PDU high-amp feeders and BESS-to-PCS trunks; pair with TF-IBR-SI 1 kV silicone insulated flat braided connectors for short module-to-busbar vibration links, or TF-SIHC 3.6/6 kV silicone for +180 °C medium-voltage switchgear. Minimum order 50 m per size, delivered in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-BESS-DC Short-Circuit-Proof Dual-Wall LSZH Construction

Combines flexible Class 5/6 tinned copper (or Class 5 aluminum) with dual-wall short-circuit-proof cross-linked EPR/XLPO insulation and a rugged UV/oil-resistant LSZH outer sheath.

Clean 2D circular technical cross-section of TF-BESS-DC 1.5 kV DC high-amp single-core power cable showing dense concentric bundle of fine silver-grey tinned copper wires, thick uniform light-grey short-circuit-proof EPR/XLPO inner insulation wall and matte black LSZH outer sheath
Dual-wall short-circuit-proof cross-section: concentric fine tinned-copper conductor, high-dielectric light-grey inner wall and rugged black LSZH sheath.
TF-BESS-DC 1.5 kV DC & 1.8/3 kV Short-Circuit-Proof High-Amp Power Cable for AI Data Center UPS & Utility BESS (16–400 mm²) construction
ComponentMaterial and construction
1. Fine-Stranded Tinned Copper (16–400 mm²) or Flexible Aluminum (95–400 mm²)IEC 60228 Class 5/6 tinned copper resists battery-room corrosion and routes smoothly around tight rack corners; optional Class 5 aluminum cuts cable mass and cost on long BESS DC trunks.
2. High-Dielectric Short-Circuit-Proof Inner Insulation (+120 °C)Light-grey cross-linked halogen-free EPR/XLPO inner insulation wall providing enhanced dielectric margin (6 kV AC routine test) and short-circuit/earth-fault protection up to 1,000 V AC / 1,500 V DC.
3. Heavy-Duty Matte Black (or Red/Blue Polarity) LSZH Outer SheathZero-halogen, flame-retardant, oil-, UV-, ozone- and moisture-resistant elastomer/XLPO outer jacket suitable for indoor raised-floor trays, outdoor BESS containers and direct burial.
4. Optional Factory Pre-Terminated Compression Lugs & Polarity StripingAvailable on continuous reels (black, red or blue jacket for DC +/- polarity coding) or pre-terminated with heavy-wall tinned copper DIN 46235 lugs and heat-shrink boots.

TF-BESS-DC Copper & Aluminum Model Code Breakdown

  • TF-BESS-DC: Series identifier: TEBAOFLEX 1.5 kV DC / 1.8/3 kV AC short-circuit-proof UPS & BESS high-amp cable
  • 16Cu to 400Cu: Class 5/6 fine-stranded tinned copper cross-section in mm² (rack flexibility & tight bends)
  • 95Al to 400Al: Class 5 flexible aluminum cross-section in mm² (weight- and cost-optimized BESS-to-PCS trunks)
  • -BK / -RD / -BU: LSZH outer jacket DC polarity color code: Black (-BK), Red (-RD) or Blue (-BU)
  • 1.8/3kV SC: Dual-wall short-circuit and earth-fault resistant insulation architecture rated +120 °C continuous
Applications

TF-BESS-DC AI Data Center UPS, BESS & PCS Feeder Applications

Engineered for mission-critical 24/7 high-density DC and AC power distribution in computing, utility storage and industrial backup power facilities.

Modern AI data center UPS power distribution room and containerized utility BESS lithium battery rack interior fitted with thick matte black and red TF-BESS-DC 1.5 kV DC high-amp flexible single-core power cables routed cleanly on stainless ladder racks
AI data center UPS and utility BESS battery rack power hall using neatly bundled black and red TF-BESS-DC 1.5 kV DC feeders.
  • AI and hyperscale data center UPS battery strings, static transfer switches (STS), PDU/RPP feeders and backup generator switchboards.
  • Containerized 1,500 V DC utility-scale battery energy storage systems (BESS) linking battery clusters, DC combiner boxes and PCS inverters.
  • Short-circuit and earth-fault resistant switchgear internal power links up to 1,000 V AC / 1,500 V DC (NSHXAFÖ 1.8/3 kV functional envelope).
  • Heavy-duty EV megawatt charging stations (MCS), DC microgrids and industrial rectifier DC bus feeders.

TF-BESS-DC vs Silicone MV Switchgear vs Insulated Braid vs Rigid N2XH

TF-BESS-DC (1.5 kV DC / 1.8/3 kV) vs TF-SIHC (+180 °C Silicone) vs TF-IBR Insulated Flat Braid vs Standard N2XH
Power Cable FamilyVoltage & Temp RatingFlexibility & Short-CircuitPrimary Data Center / BESS Role
TF-BESS-DC High-Amp Single-Core (this page)1.5 kV DC / 1.8/3 kV AC; -40 to +120 °C LSZHClass 5/6 flexible; short-circuit & earth-fault proofUPS battery strings, BESS rack-to-PCS feeders & buried DC trunks
TF-SIHC Double-Insulated Silicone1.8/3 kV & 3.6/6 kV AC; -60 to +180 °C0.07/0.10 mm ultra-flex; EN 45545 fire designCompact MV switchgear, rail traction converters & +180 °C cabinets
TF-IBR-SI Insulated Flat Braided Copper1 kV AC / 1.5 kV DC; -60 to +180 °CFlat 90° folds + press-welded copper bolt padsShort module-to-busbar links & breaker vibration isolation
Rigid N2XH Fixed LSZH Cable0.6/1 kV AC; +90 °C fixed Class 1/2Rigid installation (wide bend radius)Permanent building LV risers and non-flexing main switchrooms

Combine TF-BESS-DC for long high-amp UPS/BESS runs with TF-IBR-SI insulated flat braids at tight battery-terminal or breaker transitions.

TF-BESS-DC 1.5 kV DC UPS & BESS Power Cable RFQ Checklist

  • System voltage (1,000 V DC, 1,500 V DC or 1.8/3 kV AC short-circuit-proof) and continuous load current per pole.
  • Conductor preference: Class 5/6 tinned copper (16–400 mm²) for rack flexibility or Class 5 aluminum (95–400 mm²) for cost-optimized trunks.
  • Jacket polarity color coding (black, red, blue or striped) and installation environment (indoor raised floor, outdoor BESS container or direct burial).
  • Delivery form: continuous reels (50 m MOQ per size/color) or pre-terminated battery jumpers with DIN 46235 tinned copper compression lugs.
  • Required fire/smoke test documentation and project delivery schedule (7 to 45 working days).

Related selection resources

TF-BESS-DC 1.5 kV DC & 1.8/3 kV UPS / BESS Power Cable FAQ

Why use a 1.8/3 kV short-circuit-proof cable like TF-BESS-DC on 480 V–1,500 V DC UPS and BESS racks?

Zero catastrophic earth-fault arcing: dual-wall 1.8/3 kV short-circuit-proof insulation prevents line-to-ground and pole-to-pole shorts across ungrounded or high-fault-current battery racks, protecting live UPS rooms and containerized BESS enclosures before upstream fuses clear.

How much current advantage does TF-BESS-DC's +120 °C rating deliver over +90 °C cables?

Roughly 15% to 22% higher continuous ampacity at the same cross-section (or one conductor step smaller at identical load), cutting cable tray congestion and copper spend across dense AI data center UPS halls.

Can TF-BESS-DC be installed directly underground between BESS containers and PCS inverters?

Yes. Its cross-linked halogen-free outer sheath is UV-, ozone-, oil- and water-resistant for both indoor raised-floor trays and direct-burial outdoor DC feeder trenches.

When should we select flexible aluminum TF-BESS-DC-Al instead of tinned copper TF-BESS-DC-Cu?

Choose flexible Class 5 aluminum (95–400 mm²) on longer straight DC trunk runs (typically > 20–30 m between BESS skids and PCS skids) to cut cable weight by ~50%; keep tinned copper (16–400 mm²) inside tight battery racks and high-current UPS switchboards.

What is the minimum order quantity and delivery lead time for TF-BESS-DC?

50 m standard MOQ per size and color on bulk export reels, or custom pre-lugged BESS jumper kits delivered in 7 to 45 working days.

Specifications

TF-BESS-DC Copper (16–400 mm²) & Aluminum (150–400 mm²) Schedule

TF-BESS-DC Voltage, +120 °C Thermal, LSZH & Bending Summary

  • 1.5 kV DC & 1.8/3 kV short-circuit-proof: Thick dual-wall halogen-free XLPO/EPR insulation provides earth-fault and short-circuit resistance up to 1,000 V AC / 1,500 V DC inside live UPS & BESS racks
  • +120 °C high-amp conductor rating: Higher continuous conductor temperature permits smaller cross-sections or lower I²R DC feeder losses in dense AI data center power halls
  • 16–400 mm² tinned Cu & 95–400 mm² Al: Flexible Class 5/6 tinned copper for tight battery-cabinet bends and optional stranded aluminum conductors for economical long-run BESS-to-PCS trunks
  • LSZH, UV, oil & direct-burial ready: Low-smoke zero-halogen jacket (IEC 60754 / IEC 61034 / IEC 60332-3-22) with moisture, ozone and oil resistance for indoor white-space or buried conduit
  • 50 m MOQ & pre-lugged jumper option: Supplied on bulk reels (50 m MOQ) or cut-to-length battery rack jumpers with hydraulic copper compression lugs in 7 to 45 working days
TF-BESS-DC 1.5 kV DC & 1.8/3 kV Short-Circuit-Proof High-Amp Power Cable for AI Data Center UPS & Utility BESS (16–400 mm²) technical data
ParameterValue
Rated voltage1,500 V DC continuous (max 1,800 V DC) and 1.8/3 kV AC short-circuit-proof rating; 6.0 kV AC routine test voltage
Conductor and temperature envelope16–400 mm² Class 5/6 tinned copper or 95–400 mm² Class 5 aluminum; -40 °C to +120 °C continuous (+250 °C short-circuit)
Fire and halogen-free safetyHalogen-free (IEC 60754-1/-2), low smoke (IEC 61034-1/-2), vertical bundle flame-retardant (IEC 60332-3-22)
Environmental and mechanical ratingUV, ozone, oil and water resistant; suitable for indoor raised-floor trays, outdoor BESS skids and direct burial
Minimum bending radius4× OD fixed installation inside racks and trays; 6× OD occasional flexing during cabinet service
Minimum order and lead time50 m standard MOQ per size/color (or pre-lugged BESS jumper kits), delivered in 7 to 45 working days

TF-BESS-DC Copper & Aluminum 1.5 kV DC Dimension & Ampacity Schedule

TF-BESS-DC 1.5 kV DC / 1.8/3 kV High-Amp UPS & BESS Flexible Power Cable Schedule (16–400 mm² Cu & 95–400 mm² Al)
Model CodeConductor Material & Size (mm²)Rated VoltageApprox. OD (mm)Ref. DC Current Free Air (+40 °C / 120 °C) (A)Min. Fixed Bend R (mm)Approx. Weight (kg/km)Next step
TF-BESS-DC-16CuTinned Copper Class 5/6 · 161.5 kV DC / 1.8/3 kV AC10.612543215Request this size
TF-BESS-DC-25CuTinned Copper Class 5/6 · 251.5 kV DC / 1.8/3 kV AC12.416850320Request this size
TF-BESS-DC-35CuTinned Copper Class 5/6 · 351.5 kV DC / 1.8/3 kV AC13.820856430Request this size
TF-BESS-DC-50CuTinned Copper Class 5/6 · 501.5 kV DC / 1.8/3 kV AC15.826064590Request this size
TF-BESS-DC-70CuTinned Copper Class 5/6 · 701.5 kV DC / 1.8/3 kV AC17.832572810Request this size
TF-BESS-DC-95CuTinned Copper Class 5/6 · 951.5 kV DC / 1.8/3 kV AC19.8395801,075Request this size
TF-BESS-DC-120CuTinned Copper Class 5/6 · 1201.5 kV DC / 1.8/3 kV AC21.8460881,340Request this size
TF-BESS-DC-150CuTinned Copper Class 5/6 · 1501.5 kV DC / 1.8/3 kV AC24.2530971,670Request this size
TF-BESS-DC-185CuTinned Copper Class 5/6 · 1851.5 kV DC / 1.8/3 kV AC26.66051072,040Request this size
TF-BESS-DC-240CuTinned Copper Class 5/6 · 2401.5 kV DC / 1.8/3 kV AC29.87201202,630Request this size
TF-BESS-DC-300CuTinned Copper Class 5/6 · 3001.5 kV DC / 1.8/3 kV AC32.88301323,260Request this size
TF-BESS-DC-400CuTinned Copper Class 5/6 · 4001.5 kV DC / 1.8/3 kV AC37.29901494,310Request this size
TF-BESS-DC-150AlFlexible Aluminum Class 5 · 1501.5 kV DC / 1.8/3 kV AC24.241097725Request this size
TF-BESS-DC-240AlFlexible Aluminum Class 5 · 2401.5 kV DC / 1.8/3 kV AC29.85601201,085Request this size
TF-BESS-DC-400AlFlexible Aluminum Class 5 · 4001.5 kV DC / 1.8/3 kV AC37.27651491,710Request this size

Reference ampacity assumes single cable in free air at +40 °C ambient and +120 °C conductor temperature; apply standard IEC 60364-5-52 grouping derating factors for multi-cable trays, tight conduits or direct-buried soil resistivity.

ASCII part references for BOM and ERP entry: TF-BESS-DC-16Cu to TF-BESS-DC-400Cu, TF-BESS-DC-150Al, TF-BESS-DC-240Al, TF-BESS-DC-400Al.

Standards

TF-BESS-DC Reference Short-Circuit, Smoke & Flame Standards

TF-BESS-DC 1.5 kV DC & 1.8/3 kV Short-Circuit-Proof High-Amp Power Cable for AI Data Center UPS & Utility BESS (16–400 mm²) standards and test references
Standard or specificationApplication
DIN VDE 0250-602 (NSHXAFÖ 1.8/3 kV Functional Envelope) & IEC 60228Short-circuit and earth-fault resistant single-core dual-wall halogen-free flexible power cable design basis.
IEC 60332-3-22, IEC 60754-1/-2 & IEC 61034-1/-2Data center and containerized BESS low-smoke zero-halogen fire safety design criteria (project test records confirmed per quotation).

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and 6 kV routine dielectric verification

IEC 60332-3-22 — Vertical Flame Spread Test for Vertically-Mounted Bunched Cables

IEC 61034-2 — Measurement of Smoke Density of Cables Burning Under Defined Conditions

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.