TF-IBR 1 kV Silicone & FR PVC Insulated Flat Braided Copper Power Connector (10–210 mm² / 145–540 A)

TF-IBR (TF-IBR-SI & TF-IBR-PVC) is a precision insulated flat braided copper power connector built from soft-annealed bare Cu-ETP1 fine wire (0.16 / 0.20 mm strands) with solid press-welded low-resistance contact ends. Offered in two extruded insulation tiers: 1 kV AC / 1.5 kV DC halogen-free self-extinguishing silicone (10–140 mm², 60 Shore A, 9 kV spark test, -60 to +180 °C) and lead-free flame-retardant PVC (10–210 mm², 145–540 A) for switchgear, transformers, UPS/BESS racks and grounding.

Product information
SKU
TF-IBR-10-210
Brand
TEBAOFLEX
Product overview

TF-IBR insulated flat braided copper power connectors (10 mm² to 210 mm², 145 A to 540 A continuous air-cooled rating, up to 1 kV AC / 1.5 kV DC) provide shock-protected, vibration-damping electrical links inside compact switchgear cubicles, power transformers, inverter cabinets, UPS/BESS battery racks and industrial drive assemblies.

Unlike bare braided straps that force wide phase-to-phase air clearances, TF-IBR extrudes a continuous insulating wall directly over a flat woven bundle of soft-annealed Cu-ETP1 fine copper wires (0.16 mm or 0.20 mm individual wire diameter). Two jacket chemistries match cabinet thermal budgets: TF-IBR-SI uses halogen-free self-extinguishing 60 Shore A silicone rubber spark-tested at 9 kV for -60 °C to +180 °C high-heat zones, while TF-IBR-PVC uses lead-free flame-retardant black PVC for standard -25 °C to +80 °C panel distribution. Both styles terminate in solid press-welded copper contact zones without filler alloys or crimped ferrules, holding micro-ohm joint resistance stable across repeated load cycles.

Choose TF-IBR whenever confined phase spacing demands insulated flat copper flexibility; choose bare press-welded laminated foil shunts (100–4,500 mm²) for open heavy busbar expansion, or TF-LIFY / TF-BESS-DC round cables for long rack-to-rack runs. Minimum order 10 pieces or 1 matched cabinet kit, delivered in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-IBR Insulated Flat Braided Copper & Press-Welded Pad Construction

Woven from soft-annealed Cu-ETP1 electrolytic copper wires, jacketed with continuous extruded halogen-free silicone or FR PVC, and consolidated at both ends via solid press-welding.

Clean 2D technical cross-section of TF-IBR insulated flat braided copper connector showing wide rectangular woven fine bare copper braid core encased in uniform matte black extruded halogen-free silicone or PVC outer jacket
Flat braided cross-section: woven fine-wire Cu-ETP1 copper core tightly wrapped by a continuous extruded dielectric insulation wall.
TF-IBR 1 kV Silicone & FR PVC Insulated Flat Braided Copper Power Connector (10–210 mm² / 145–540 A) construction
ComponentMaterial and construction
1. Soft-Annealed Bare Cu-ETP1 Flat Braided Copper CoreFine-wire 0.16 mm or 0.20 mm electrolytic copper strands (>= 100% IACS) braided flat across 10 mm² to 210 mm² for tight bending radius and superior surface-area heat dissipation.
2. Extruded Halogen-Free Silicone (TF-IBR-SI) or FR PVC (TF-IBR-PVC) InsulationTF-IBR-SI: 1 kV AC / 1.5 kV DC black self-extinguishing halogen-free silicone (60 Shore A, 9 kV spark test, -60 to +180 °C). TF-IBR-PVC: lead-free flame-retardant black PVC (-25 to +80 °C).
3. Solid Press-Welded Low-Resistance Copper Contact EndsBoth braid ends are hot-pressed into solid homogeneous copper terminal pads (bare, tin-plated or silver-plated) with zero solder, zero brazing flux and CNC-drilled M6–M16 bolt holes.
4. Custom Geometry & Pre-Bent Cabinet FormationsAvailable straight, Z-offset, 90°-twisted or multi-layer stacked to absorb transformer hum, switchgear breaker recoil and thermal busbar growth.

TF-IBR Silicone & PVC Model Code Breakdown

  • TF-IBR: Series identifier for TEBAOFLEX insulated flat braided copper power connectors
  • -SI / -PVC: Extruded insulation chemistry: -SI (1 kV AC / 1.5 kV DC halogen-free silicone, 180 °C) or -PVC (FR lead-free PVC, 80 °C)
  • 10 to 210: Nominal copper cross-section in mm² (10–140 mm² silicone; 10–210 mm² FR PVC)
  • -TIN / -AG: Optional contact pad plating suffix: electrolytic tin (-TIN) or silver (-AG); omit for bare Cu-ETP1
  • L / M6–M16: Hole-center-to-hole-center overall length in mm and CNC-drilled mounting hole diameter (M6 to M16)
Applications

TF-IBR Switchgear, Transformer, UPS & BESS Applications

Specified across electrical distribution, power electronics, energy storage and industrial machinery where compact phase spacing requires insulated flexible copper jumpers.

Modern industrial switchgear and BESS battery power distribution cabinet interior fitted with neatly bolted matte black TF-IBR insulated flat braided copper busbar jumpers
Switchgear and battery rack busbar bay using compact TF-IBR insulated flat braided copper power connectors for vibration-free high-current transitions.
  • Low-voltage and medium-voltage switchgear busbar jumpers, molded-case/air circuit breaker (MCCB/ACB) drop links and cabinet earthing.
  • AI data center UPS cabinets, stationary BESS battery module interconnects and DC inverter busbar expansion joints.
  • Dry-type and oil-immersed transformer LV bushing vibration-isolation connectors preventing mechanical strain on porcelain insulators.
  • Induction furnace control cubicles, rectifier banks, capacitor switching panels and high-current test benches.

TF-IBR Insulated Flat Braid vs Bare Laminated Shunts vs Round Cables

TF-IBR Insulated Flat Braided Connector vs Bare Laminated Copper Shunt vs Round Extra-Flexible Switchgear Cable
Conductor StyleInsulation & Phase ClearanceCross-Section & BendingBest Installation Scope
TF-IBR Insulated Flat Braid (this page)Extruded 1 kV Silicone or FR PVC (compact clearance)10–210 mm²; ultra-tight flat 90° foldsSwitchgear cubicles, UPS/BESS battery racks, transformers & inverter links
TF-SHUNT Bare Laminated Foil / BraidBare copper (requires air gap or external guards)100–4,500 mm²; multi-kA busbar expansionHigh-current open busbars, heavy transformers & furnace secondary shunts
TF-LIFY / ESUY Extra-Flexible RoundPVC / TPE-U / clear PVC round jacket2.5–240 mm²; multi-axis round routingLonger cabinet harnesses, test leads & visual-inspection grounding jumpers
TF-BESS-DC 1.5 kV DC High-Amp Single-CoreDual-wall short-circuit-proof LSZH/XLPO16–400 mm²; long rack-to-inverter runsContainerized BESS strings, AI data center UPS feeders & buried DC trunks

Use TF-IBR wherever tight insulated bends and press-welded bolt pads beat bulky round cable lugs inside crowded cabinets.

TF-IBR Insulated Flat Braided Copper Connector RFQ Checklist

  • Insulation selection: TF-IBR-SI (1 kV AC / 1.5 kV DC halogen-free -60 to +180 °C silicone) or TF-IBR-PVC (flame-retardant black PVC).
  • Required cross-section (10–210 mm²), target continuous current (A) and maximum permissible cabinet ambient temperature.
  • Exact hole-center-to-hole-center length (mm), contact pad width × length, bolt-hole diameter/pattern (M6–M16) and any 90° twist or Z-bend offset.
  • Contact surface plating preference: bare copper, electrolytic tin-plated (recommended for aluminum bus interfaces) or silver-plated.
  • Required quantity per part number (MOQ 10 pieces or 1 cabinet kit, lead time 7 to 45 working days).

Related selection resources

TF-IBR 1 kV Insulated Flat Braided Copper Connector FAQ

What is the difference between TF-IBR-SI silicone and TF-IBR-PVC insulated flat braided copper connectors?

180 °C vs 80 °C thermal headroom is the main divider: TF-IBR-SI uses halogen-free 60 Shore A black silicone rated 1 kV AC / 1.5 kV DC (9 kV spark-tested, -60 to +180 °C) across 10–140 mm² for hot switchgear, UPS/BESS and transit enclosures, whereas TF-IBR-PVC uses lead-free flame-retardant black PVC across 10–210 mm² (145–540 A) for economical indoor distribution panels.

Why are TF-IBR contact ends press-welded instead of crimped with separate copper lugs?

Zero intermediate joint resistance: resistance press-welding fuses the fine Cu-ETP1 braid strands into a solid homogeneous copper pad without solder, brazing filler or crimped barrel seams—cutting contact heating, saving axial space inside tight breakers and eliminating strand pull-out.

Can TF-IBR insulated flat braided jumpers be supplied tin-plated or silver-plated on the contact pads?

Yes. Both TF-IBR-SI and TF-IBR-PVC can be supplied with bright bare copper, electrolytic tin-plated contact zones (preventing galvanic corrosion against aluminum busbars) or silver-plated pads for high-duty switchgear contacts.

Can TF-IBR connectors handle BESS battery racks and AI data center UPS cabinets?

Yes. TF-IBR-SI carries 1.5 kV DC continuous insulation with zero-halogen low-smoke silicone jacket chemistry, making it ideal for tight inter-module battery rack links, MCCB/fuse drops and transformer-to-UPS vibration decoupling.

What is the minimum order quantity and delivery lead time for custom TF-IBR connectors?

10 pieces per drawing or 1 matched switchgear/cabinet kit, custom press-welded and CNC-drilled to your pad dimensions in 7 to 45 working days.

Specifications

TF-IBR Silicone & FR PVC Dimension and Ampacity Schedule

TF-IBR Voltage, Spark Test, Temperature & Current Summary

  • Two extruded insulation classes: TF-IBR-SI 1 kV AC / 1.5 kV DC halogen-free black silicone (-60 to +180 °C, 9 kV spark test) and TF-IBR-PVC lead-free self-extinguishing black PVC
  • Press-welded solid copper contact ends: Zero-solder diffusion/resistance press-welded Cu-ETP1 pads eliminate lug crimp transition resistance and prevent wire pull-out under thermal cycling
  • 10–210 mm² / 145–540 A air-cooled span: Flat woven geometry folds cleanly in tight 90° switchgear bends and lowers AC skin-effect losses compared to equivalent round cables
  • Custom drilling, tin plating & lengths: Supplied cut-to-length with customer hole diameters (M6–M16), slotted pads, double-braid stacks or optional tin/silver contact plating
  • 10 pieces / 1 switchgear kit MOQ: Custom-manufactured to busbar drawing with dimensional and resistance checks in 7 to 45 working days
TF-IBR 1 kV Silicone & FR PVC Insulated Flat Braided Copper Power Connector (10–210 mm² / 145–540 A) technical data
ParameterValue
Rated voltage and spark testTF-IBR-SI: 1 kV AC / 1.5 kV DC (9 kV routine spark test); TF-IBR-PVC: up to 1 kV AC cabinet insulation
Conductor cross-section and strands10 mm² to 140 mm² (TF-IBR-SI silicone) and 10 mm² to 210 mm² (TF-IBR-PVC), bare Cu-ETP1 0.16 mm / 0.20 mm wires
Continuous air-cooled current rating145 A to 540 A per single insulated flat braid (ambient +35 °C, ΔT 30–45 K; higher in parallel stacks)
Operating temperature rangeTF-IBR-SI halogen-free silicone: -60 °C to +180 °C; TF-IBR-PVC flame-retardant PVC: -25 °C to +80 °C
Terminal contact constructionSolid press-welded homogeneous Cu-ETP1 contact areas with custom CNC bolt holes (M6–M16) and optional tin/silver plating
Minimum order and lead time10 pieces or 1 switchgear assembly kit custom-built to drawing in 7 to 45 working days

TF-IBR Insulated Flat Braided Copper Size & Ampacity Schedule

TF-IBR-SI (1 kV Silicone, 10–140 mm²) & TF-IBR-PVC (FR PVC, 10–210 mm²) Insulated Flat Braided Copper Connector Schedule
Model CodeInsulation & RatingCross-Section (mm²)Flat Width × Thickness (mm)Ref. Current Air (A)Standard Bolt Hole (mm)Order MOQNext step
TF-IBR-SI-101 kV Halogen-Free Silicone (-60/+180 °C)1017 × 3.8145Ø 6.5 (M6)10 pcs / kitRequest this size
TF-IBR-SI-161 kV Halogen-Free Silicone (-60/+180 °C)1621 × 4.2185Ø 8.5 (M8)10 pcs / kitRequest this size
TF-IBR-SI-251 kV Halogen-Free Silicone (-60/+180 °C)2526 × 4.8235Ø 10.5 (M10)10 pcs / kitRequest this size
TF-IBR-SI-501 kV Halogen-Free Silicone (-60/+180 °C)5032 × 6.2340Ø 10.5 (M10)10 pcs / kitRequest this size
TF-IBR-SI-701 kV Halogen-Free Silicone (-60/+180 °C)7038 × 7.0415Ø 12.5 (M12)10 pcs / kitRequest this size
TF-IBR-SI-1201 kV Halogen-Free Silicone (-60/+180 °C)12046 × 8.5510Ø 12.5 (M12)10 pcs / kitRequest this size
TF-IBR-SI-1401 kV Halogen-Free Silicone (-60/+180 °C)14050 × 9.2540Ø 14.5 (M14)10 pcs / kitRequest this size
TF-IBR-PVC-16FR Lead-Free Black PVC (-25/+80 °C)1620 × 4.0165Ø 8.5 (M8)10 pcs / kitRequest this size
TF-IBR-PVC-35FR Lead-Free Black PVC (-25/+80 °C)3528 × 5.2245Ø 10.5 (M10)10 pcs / kitRequest this size
TF-IBR-PVC-50FR Lead-Free Black PVC (-25/+80 °C)5032 × 6.0305Ø 10.5 (M10)10 pcs / kitRequest this size
TF-IBR-PVC-95FR Lead-Free Black PVC (-25/+80 °C)9540 × 7.8410Ø 12.5 (M12)10 pcs / kitRequest this size
TF-IBR-PVC-150FR Lead-Free Black PVC (-25/+80 °C)15050 × 9.5485Ø 14.5 (M14)10 pcs / kitRequest this size
TF-IBR-PVC-210FR Lead-Free Black PVC (-25/+80 °C)21058 × 11.2540Ø 16.5 (M16)10 pcs / kitRequest this size

Current ratings correspond to free-air single-braid installation at +35 °C ambient with permissible conductor temperature rise (silicone +180 °C allows compact cross-sections in enclosed hot panels; PVC limited to +80 °C). Parallel-stacked connectors derate slightly for mutual heating; confirm exact stack ampacity on quotation.

ASCII part references for BOM and ERP entry: TF-IBR-SI-10, TF-IBR-SI-16, TF-IBR-SI-25, TF-IBR-SI-50, TF-IBR-SI-70, TF-IBR-SI-120, TF-IBR-SI-140, TF-IBR-PVC-16, TF-IBR-PVC-35, TF-IBR-PVC-50, TF-IBR-PVC-95, TF-IBR-PVC-150, TF-IBR-PVC-210.

Standards

TF-IBR Reference Copper, Flame & Halogen-Free Standards

TF-IBR 1 kV Silicone & FR PVC Insulated Flat Braided Copper Power Connector (10–210 mm² / 145–540 A) standards and test references
Standard or specificationApplication
DIN EN 13602 (Cu-ETP1) & DIN 46444Soft-annealed fine-wire electrolytic copper flat braiding design (>= 100% IACS conductivity).
IEC 60332-1-2 & IEC 60754-1/-2 (TF-IBR-SI)Self-extinguishing flame retardance across both series; zero-halogen low-toxicity verification on TF-IBR-SI silicone insulation with 9 kV routine spark testing.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and 9 kV spark-test quality records

DIN EN 13602 — Drawn Round Copper Wire for the Manufacture of Electrical Conductors

IEC 60332-1-2 — Vertical Flame Propagation Test for a Single Insulated Wire or Cable

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.