TF-WCT 3,000 V Clamped Parallel-Bundle & Tin-Plated Anti-Chloride Water-Cooled High-Current Cable (95–8,000 mm²)

TF-WCT-CLAMP (TF-WCT-SN tin-plated anti-chloride and TF-WCT-CL clamped-range water-cooled high-current cable) operates up to 3,000 V across 95 mm² to 8,000 mm² (1,000 A to 45,000 A). Engineered with corrosion-resistant tin-plated fine copper strands for high-chloride or non-deionized cooling water and integral 260–320 mm rigid clamping zones that lock parallel furnace cables every 1.5–2.0 m against short-circuit electromagnetic whipping.

Product information
SKU
TF-WCT-CLAMP
Brand
TEBAOFLEX
Product overview

TF-WCT-CLAMP combines two critical reliability upgrades in one 3,000 V water-cooled high-current cable platform: full tin-plated copper conductors (TF-WCT-SN, 95 mm² to 8,000 mm²) for steelworks and foundries operating with high-chloride, hard or coastal cooling water, and integral rigid clamping sections (TF-WCT-CL, 120 mm² to 700 mm², 1,000 A to 5,500 A) for multi-cable parallel furnace circuits.

In bare-copper water-cooled cables running on non-deionized or high-chloride recirculating plant water, electrochemical pitting attacks fine copper filaments within months—raising conductor resistance, choking cooling manifolds with green copper-oxide scale and triggering sudden overheating. Simultaneously, parallel un-clamped cables whip violently during 50–100 kA arc strikes unless clamped tightly every 1.5 m to 2.0 m; yet standard external clamps crush ordinary rubber hoses. TF-WCT-CLAMP solves both failure modes through uniform electrolytic tin plating over every fine copper strand and internal solid rigid clamping zones (260–320 mm length) that absorb high saddle-clamp compression while keeping coolant passages 100% open.

Specify TF-WCT-SN across 95–8,000 mm² wherever cooling water exhibits elevated chloride content, dissolved oxygen or conductivity above 50 μS/cm; specify TF-WCT-CL whenever two or more parallel cables run closely together along furnace walls or transformer racks; use TF-WCP-PIPE for direct rigid copper pipe coupling. Minimum order 2 pieces (1 pair) or 1 furnace set, lead time 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-WCT-CLAMP 3,000 V Clamped & Tin-Plated Cable Construction

Manufactured with DIN EN 13602 tin-plated soft-annealed copper ropes, solderless one-step pressed copper heads, 3,000 V insulating hoses and non-magnetic stainless clamping bands.

Clean 2D circular engineering cross-section of TF-WCT-CLAMP 3000 V tin-plated anti-chloride water-cooled cable showing central coolant core, 8 silver-gray tin-plated copper rope bundles, annular water space and double-ply insulating EPDM hose
Anti-chloride tin-plated cross-section: 8 concentric tin-coated copper ropes around a perforated core inside a 3,000 V flame-retardant coolant hose.
TF-WCT 3,000 V Clamped Parallel-Bundle & Tin-Plated Anti-Chloride Water-Cooled High-Current Cable (95–8,000 mm²) construction
ComponentMaterial and construction
1. Tin-Plated Soft-Annealed Electrolytic Copper Ropes (Anti-Chloride)Continuous electrolytic tin coating over ultra-fine Cu-ETP strands (95–8,000 mm²) resists chloride-ion corrosion, water-scale incrustation and oxygen attack in harsh plant cooling loops.
2. Integral Rigid Intermediate Clamping Zone (TF-WCT-CL, 260–320 mm)Precision-positioned rigid internal support sleeves along the hose span allow external hardwood or non-magnetic saddle clamps every 1.5–2.0 m to resist dynamic short-circuit forces without pinching water flow.
3. One-Step Cold-Pressed Forged Copper Cable HeadsAll conductor ropes are pressed simultaneously into individual bore holes inside forged Cu-ETP/Cu-HCP heads (tin- or silver-plated palms optional) with threaded axial or 90-degree rotated cooling water ports (R 1/4" to R 1-1/2").
4. 3,000 V Flame-Retardant Insulating & Molten-Splash Coolant HoseHigh-dielectric multi-ply EPDM/CR outer hose (6 bar working / 8.5–10 bar factory hydro-test; < 2 bar normal pressure drop) engineered to resist radiant heat, ozone and liquid-metal splash.

TF-WCT-CLAMP Model, Clamping Zone & Tin-Plating Code Breakdown

  • TF-WCT-CL: 3,000 V water-cooled high-current cable with integral 260–320 mm rigid intermediate clamping zone (120–700 mm²)
  • TF-WCT-SN: Electrolytic tin-plated anti-chloride copper conductor build for poor or coastal cooling water (95–8,000 mm²)
  • a1 (260–320 mm): Rigid non-collapsible clamping-collar length engineered for 1.5–2.0 m parallel saddle-bracket spacing
  • R 1/4" to R 1-1/2": Threaded cooling-water inlet/outlet ports supplied axial or rotated 90 degrees per installation sketch
  • -HT / -AG: Optional molten-metal splash thermal shield (-HT) and silver-plated contact palm surfaces (-AG)
Applications

TF-WCT-CLAMP High-Chloride Water & Parallel Furnace Bundle Duty

Designed for coastal steel plants, high-chloride recirculating foundry loops and closely spaced parallel high-current furnace circuits up to 3,000 V.

Eight heavy parallel water-cooled furnace cable assemblies undergoing 0.85 MPa (8.5 bar) factory hydrostatic pressure testing with a calibrated pressure gauge and machined rectangular copper electrode heads inside the TEBAOFLEX workshop
Workshop hydrostatic pressure inspection at 0.85 MPa (8.5 bar) across eight parallel heavy-duty water-cooled furnace cable assemblies prior to packing.
  • Coastal and industrial steelmaking EAF, LF and SAF plants operating with elevated-chloride or hard recirculating cooling water.
  • Multi-cable parallel furnace circuits (2 to 6 cables per phase) requiring rigid saddle clamping every 1.5–2.0 m to counteract electromagnetic whipping.
  • High-voltage 1,000 V to 3,000 V induction melting, vacuum refining and electro-metallurgical power feeders.
  • Movable high-current furnace covers, tilt platforms and transformer-room feeders subject to molten splash and dynamic current surges.

TF-WCT-CLAMP vs Bare EAF Cable vs Induction & Pipe-Connection Leads

TF-WCT-CLAMP (3,000 V Clamped & Tin-Plated) vs Standard Bare EAF Cable vs TF-IFL Induction Lead
Water-Cooled FamilyConductor & Mechanical SpecialtyVoltage & Section EnvelopeBest Engineering Fit
TF-WCT-CLAMP (this page)Tin-plated anti-chloride copper + 260–320 mm rigid clamping collarsUp to 3,000 V; 95–8,000 mm² (1–45 kA)High-chloride / hard cooling water OR closely clamped parallel bundles
EAF / LF Water-Cooled CableBare multi-rope fluted core + bumper rings + rotating swivel headUp to 1,500 V; 1,000–7,000 mm²Standard treated closed-loop EAF/LF catenary electrode-arm swings
TF-IFL / TF-WCHC Induction LeadsBare copper + JIC 37° swivel flare or NPT flat palmsUp to 3,000 V; 35–2,000 mm² (70–2,500 MCM)Coreless tilting foundry induction furnaces using clean closed water
TF-WCP-PIPE Pipe-ConnectionDetachable Type D/E pipe-contact ring & union nutUp to 3,000 V; 300–1,480 mm² (2.9–15 kA)Removable direct links between Ø 40–60 mm rigid water-cooled copper pipes

In coastal mills or open cooling-tower circuits with elevated chloride ions, specifying TF-WCT-SN tin-plated copper eliminates rapid bare-strand corrosion and clogged coil passages.

TF-WCT-CLAMP Water-Cooled Cable Drawing & RFQ Checklist

  • Select required option: TF-WCT-SN (tin-plated anti-chloride), TF-WCT-CL (integral rigid clamping range), or combined tin-plated + clamped build.
  • Conductor cross-section (95–8,000 mm²), operating current (A), voltage (up to 3,000 V) and frequency (50/60 Hz up to 10 kHz).
  • Exact overall length (mm), rigid clamping zone length a1 (260–320 mm) and exact mounting position along the span.
  • Terminal palm dimensions, bolt-hole pattern, and cooling water port size/orientation (axial vs 90-degree rotated R/BSPP or NPT).
  • Cooling water parameters (inlet temperature, chloride/conductivity level, available pump pressure) and splash-sleeve option.
  • Order quantity in pairs or matched furnace sets (MOQ 2 pcs / 1 pair up to 1,000 mm²; 1 pc / 1 set >= 2,000 mm²; 7 to 45 working days).

Related selection resources

TF-WCT-CLAMP Clamped & Tin-Plated Water-Cooled Cable FAQ

When should a plant specify TF-WCT-SN tin-plated copper instead of bare copper in a water-cooled cable?

Specify TF-WCT-SN whenever cooling water contains elevated chloride ions, dissolved oxygen, lime scale or conductivity above 50 μS/cm—common in coastal steel mills and semi-open cooling towers—because electrolytic tin plating shields fine copper wires from electrochemical pitting and green-oxide flaking.

How closely must parallel TF-WCT-CL water-cooled cables be clamped to prevent electromagnetic whipping?

Clamp parallel high-current water-cooled cables closely together every 1.5 m to 2.0 m using non-magnetic or hardwood brackets positioned directly over the integral 260–320 mm rigid clamping zone (a1) so short-circuit dynamic forces are absorbed without pinching coolant flow.

What happens if cooling water flow is interrupted on a TF-WCT-CLAMP cable at 8.4 A/mm²?

0.4 K/s is the approximate adiabatic copper temperature rise at 8.4 A/mm² current density if cooling water stops. Always wire a flow-rate and outlet-temperature monitor (<= +50 °C to +65 °C) into the furnace safety interlock to trip power immediately on coolant loss.

What insulating hose length is needed between different electrical potentials on 3,000 V water-cooled circuits?

Provide at least 1.0 m of electrically insulating coolant hose per 1,000 V AC (3.0 m minimum at 3,000 V AC) or 1.0 m per 100 V DC between energized terminals and grounded water manifolds to limit stray leakage currents and electrolytic fitting corrosion.

What is the hydrostatic test pressure, MOQ and lead time for TF-WCT-CLAMP cables?

All assemblies are factory hydrostatically tested at 8.5 to 10 bar (0.85 to 1.0 MPa) against a 6 bar operating limit. MOQ is 2 pieces (1 pair) for 95–1,000 mm² or 1 piece/set for 2,000–8,000 mm², produced in 7 to 45 working days.

Specifications

TF-WCT-CL (Clamped) & TF-WCT-SN (Tin-Plated) Specification Schedule

TF-WCT-CLAMP Voltage, Tin-Plating, Clamping & Pressure Summary

  • Tin-plated anti-chloride CuSn strands: 95–8,000 mm² tin-plated copper ropes stop green copper-chloride corrosion, oxygen pitting and premature strand fracture in poor or coastal water
  • Integral 260–320 mm rigid clamp range: Reinforced intermediate clamping collars let saddle brackets lock parallel bundles every 1.5–2.0 m without crushing the coolant hose
  • 3,000 V high-dielectric splash sheath: Flame-retardant electrically insulating coolant hose rated to 3,000 V AC with 10 bar factory hydrostatic test and molten-splash outer cover
  • 8.4 A/mm² economic design + 40% margin: Sized for optimal kW-loss economics (0.7 V resistive drop over 4 m) with verified continuous overload margin and 0.4 K/s water-loss sizing data
  • 2 pieces (1 pair) or 1 set MOQ: Custom-built with exact clamping zone coordinates (a1), rotated water ports and forged terminal drilling in 7 to 45 working days
TF-WCT 3,000 V Clamped Parallel-Bundle & Tin-Plated Anti-Chloride Water-Cooled High-Current Cable (95–8,000 mm²) technical data
ParameterValue
Rated voltageUp to 3000 V AC operating voltage across electrically insulating flame-retardant outer hose
Conductor and section spanTin-plated anti-chloride copper ropes 95 mm2 to 8000 mm2 (TF-WCT-SN) and clamped parallel-bundle builds 120 mm2 to 700 mm2 (TF-WCT-CL)
Economic loading and overload8.4 A/mm2 recommended economic current density with up to 40 percent continuous overload capability and 0.4 K/s adiabatic rise on coolant loss
Clamping zone and support spacing260 mm to 320 mm integral rigid clamping range (a1) engineered for 1.5 m to 2.0 m parallel saddle-clamp pitch
Minimum order and lead time2 pieces (1 pair) or 1 furnace set built to custom clamping coordinates and palm drilling in 7 to 45 working days
Hydrostatic test and pressure drop6 bar max continuous operating pressure, 8.5 to 10 bar (0.85 to 1.0 MPa) factory hydro-test, normal pressure drop up to 2 bar
Coolant isolation lengthMinimum 1 m insulating hose per 1000 V AC or per 100 V DC between potentials; outlet water kept up to +50 C to +65 C

TF-WCT-CL (120–700 mm²) 3,000 V Clamped Parallel-Bundle Schedule

TF-WCT-CL 3,000 V Clamped-Range Parallel Water-Cooled High-Current Cables (120–700 mm²) — Clamping Zone, Current & Port Schedule
Model & Copper Section50 Hz Ref. Current (A)Max. Operating FrequencyClamping Range Length a1 (mm)Hose Nom. OD (mm)Water Port ThreadPalm Width × Thick (mm)Assembly MOQNext step
TF-WCT-CL120 (120 mm²)1,000Up to 10 kHz28035R 1/4"50 × 102 pcs (1 pair)Request this size
TF-WCT-CL185 (185 mm²)1,550Up to 10 kHz31041R 3/8"60 × 122 pcs (1 pair)Request this size
TF-WCT-CL300 (300 mm²)2,500Up to 10 kHz26047R 3/8"60 × 152 pcs (1 pair)Request this size
TF-WCT-CL400 (400 mm²)3,250Up to 250 Hz30054R 1/2"80 × 202 pcs (1 pair)Request this size
TF-WCT-CL500 (500 mm²)3,780Up to 250 Hz30054R 1/2"80 × 202 pcs (1 pair)Request this size
TF-WCT-CL700S (700 mm²)5,500Up to 250 Hz30066R 1/2"80 × 252 pcs (1 pair)Request this size
TF-WCT-CL700L (700 mm²)5,500Up to 250 Hz32066R 3/4"100 × 222 pcs (1 pair)Request this size

TF-WCT-SN (95–8,000 mm²) Tin-Plated Anti-Chloride Water-Cooled Schedule

TF-WCT-SN Tin-Plated Anti-Chloride Water-Cooled High-Current Cables (95–8,000 mm², 3,000 V) — Corrosion-Resistant Furnace Schedule
Model & Tin-Plated Section50/60 Hz Ref. Current (A)Conductor FinishTypical Terminal StyleOperating / Test PressureAssembly MOQNext step
TF-WCT-SN95 (95 mm²)1,000 – 1,200Electrolytic Tin-Plated CuFlat 2-Hole / Round Head6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCT-SN300 (300 mm²)2,500 – 3,500Electrolytic Tin-Plated CuFlat 2/4-Hole Cu Head6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCT-SN500 (500 mm²)3,800 – 5,500Electrolytic Tin-Plated CuFlat 4-Hole Cu Head6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCT-SN1000 (1,000 mm²)6,000 – 8,400Electrolytic Tin-Plated CuForged 4/6-Hole Palm6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCT-SN2000 (2,000 mm²)10,000 – 14,000Electrolytic Tin-Plated CuForged 6/8-Hole EAF Head6 bar / 10 bar1 pc / 1 setRequest this size
TF-WCT-SN4000 (4,000 mm²)18,000 – 24,000Electrolytic Tin-Plated CuForged 8-Hole EAF Head6 bar / 10 bar1 pc / 1 setRequest this size
TF-WCT-SN6000 (6,000 mm²)25,000 – 34,000Electrolytic Tin-Plated CuForged 8/10-Hole EAF Head6 bar / 10 bar1 pc / 1 setRequest this size
TF-WCT-SN8000 (8,000 mm²)34,000 – 45,000Electrolytic Tin-Plated CuHeavy Custom EAF Flange6 bar / 10 bar1 pc / 1 setRequest this size

Economic sizing note: At 8.4 A/mm² loading, resistive voltage drop across a 4 m cable is approximately 0.7 V; continuous current may be exceeded by up to 40% with proportionally higher resistive losses and cooling flow. Because adiabatic conductor heating reaches ~0.4 K/s upon coolant interruption, always interlock a customer cooling-water flow monitor with the furnace trip circuit. Final dimensions and clamping coordinates are confirmed on the quotation drawing.

ASCII part references for BOM and ERP entry: TF-WCT-CL120, TF-WCT-CL185, TF-WCT-CL300, TF-WCT-CL400, TF-WCT-CL500, TF-WCT-CL700S, TF-WCT-CL700L, TF-WCT-SN95, TF-WCT-SN300, TF-WCT-SN500, TF-WCT-SN1000, TF-WCT-SN2000, TF-WCT-SN4000, TF-WCT-SN6000, TF-WCT-SN8000.

Standards

TF-WCT-CLAMP Reference Conductor & Hydrostatic Standards

TF-WCT 3,000 V Clamped Parallel-Bundle & Tin-Plated Anti-Chloride Water-Cooled High-Current Cable (95–8,000 mm²) standards and test references
Standard or specificationApplication
DIN EN 13602 (Tin-Plated ETP Copper Wire) & DIN EN 13601Corrosion-resistant tin-plated soft-annealed copper conductor stranding paired with high-conductivity forged copper terminal heads.
ISO 228-1 / DIN EN 10226 (R / BSPP Threads) & 10 bar Hydrostatic InspectionStandardized R 1/4" to R 1-1/2" axial or 90-degree rotated cooling water connections factory pressure-tested at 8.5–10 bar.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 0.85–1.0 MPa factory hydrostatic testing

DIN EN 13602 — Drawn Round Copper Wire (Bare & Tinned) for Electrical Conductors

ASTM B33 — Standard Specification for Tin-Coated Soft or Annealed Copper Wire

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.