TF-WCT 3,000 V Clamped Parallel-Bundle & Tin-Plated Anti-Chloride Water-Cooled High-Current Cable (95–8,000 mm²)
TF-WCT-CLAMP (TF-WCT-SN tin-plated anti-chloride and TF-WCT-CL clamped-range water-cooled high-current cable) operates up to 3,000 V across 95 mm² to 8,000 mm² (1,000 A to 45,000 A). Engineered with corrosion-resistant tin-plated fine copper strands for high-chloride or non-deionized cooling water and integral 260–320 mm rigid clamping zones that lock parallel furnace cables every 1.5–2.0 m against short-circuit electromagnetic whipping.
TF-WCT-CLAMP combines two critical reliability upgrades in one 3,000 V water-cooled high-current cable platform: full tin-plated copper conductors (TF-WCT-SN, 95 mm² to 8,000 mm²) for steelworks and foundries operating with high-chloride, hard or coastal cooling water, and integral rigid clamping sections (TF-WCT-CL, 120 mm² to 700 mm², 1,000 A to 5,500 A) for multi-cable parallel furnace circuits.
In bare-copper water-cooled cables running on non-deionized or high-chloride recirculating plant water, electrochemical pitting attacks fine copper filaments within months—raising conductor resistance, choking cooling manifolds with green copper-oxide scale and triggering sudden overheating. Simultaneously, parallel un-clamped cables whip violently during 50–100 kA arc strikes unless clamped tightly every 1.5 m to 2.0 m; yet standard external clamps crush ordinary rubber hoses. TF-WCT-CLAMP solves both failure modes through uniform electrolytic tin plating over every fine copper strand and internal solid rigid clamping zones (260–320 mm length) that absorb high saddle-clamp compression while keeping coolant passages 100% open.
Specify TF-WCT-SN across 95–8,000 mm² wherever cooling water exhibits elevated chloride content, dissolved oxygen or conductivity above 50 μS/cm; specify TF-WCT-CL whenever two or more parallel cables run closely together along furnace walls or transformer racks; use TF-WCP-PIPE for direct rigid copper pipe coupling. Minimum order 2 pieces (1 pair) or 1 furnace set, lead time 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-WCT-CLAMP 3,000 V Clamped & Tin-Plated Cable Construction
Manufactured with DIN EN 13602 tin-plated soft-annealed copper ropes, solderless one-step pressed copper heads, 3,000 V insulating hoses and non-magnetic stainless clamping bands.

| Component | Material and construction |
|---|---|
| 1. Tin-Plated Soft-Annealed Electrolytic Copper Ropes (Anti-Chloride) | Continuous electrolytic tin coating over ultra-fine Cu-ETP strands (95–8,000 mm²) resists chloride-ion corrosion, water-scale incrustation and oxygen attack in harsh plant cooling loops. |
| 2. Integral Rigid Intermediate Clamping Zone (TF-WCT-CL, 260–320 mm) | Precision-positioned rigid internal support sleeves along the hose span allow external hardwood or non-magnetic saddle clamps every 1.5–2.0 m to resist dynamic short-circuit forces without pinching water flow. |
| 3. One-Step Cold-Pressed Forged Copper Cable Heads | All conductor ropes are pressed simultaneously into individual bore holes inside forged Cu-ETP/Cu-HCP heads (tin- or silver-plated palms optional) with threaded axial or 90-degree rotated cooling water ports (R 1/4" to R 1-1/2"). |
| 4. 3,000 V Flame-Retardant Insulating & Molten-Splash Coolant Hose | High-dielectric multi-ply EPDM/CR outer hose (6 bar working / 8.5–10 bar factory hydro-test; < 2 bar normal pressure drop) engineered to resist radiant heat, ozone and liquid-metal splash. |
TF-WCT-CLAMP Model, Clamping Zone & Tin-Plating Code Breakdown
- TF-WCT-CL: 3,000 V water-cooled high-current cable with integral 260–320 mm rigid intermediate clamping zone (120–700 mm²)
- TF-WCT-SN: Electrolytic tin-plated anti-chloride copper conductor build for poor or coastal cooling water (95–8,000 mm²)
- a1 (260–320 mm): Rigid non-collapsible clamping-collar length engineered for 1.5–2.0 m parallel saddle-bracket spacing
- R 1/4" to R 1-1/2": Threaded cooling-water inlet/outlet ports supplied axial or rotated 90 degrees per installation sketch
- -HT / -AG: Optional molten-metal splash thermal shield (-HT) and silver-plated contact palm surfaces (-AG)
TF-WCT-CLAMP High-Chloride Water & Parallel Furnace Bundle Duty
Designed for coastal steel plants, high-chloride recirculating foundry loops and closely spaced parallel high-current furnace circuits up to 3,000 V.

- Coastal and industrial steelmaking EAF, LF and SAF plants operating with elevated-chloride or hard recirculating cooling water.
- Multi-cable parallel furnace circuits (2 to 6 cables per phase) requiring rigid saddle clamping every 1.5–2.0 m to counteract electromagnetic whipping.
- High-voltage 1,000 V to 3,000 V induction melting, vacuum refining and electro-metallurgical power feeders.
- Movable high-current furnace covers, tilt platforms and transformer-room feeders subject to molten splash and dynamic current surges.
TF-WCT-CLAMP vs Bare EAF Cable vs Induction & Pipe-Connection Leads
| Water-Cooled Family | Conductor & Mechanical Specialty | Voltage & Section Envelope | Best Engineering Fit |
|---|---|---|---|
| TF-WCT-CLAMP (this page) | Tin-plated anti-chloride copper + 260–320 mm rigid clamping collars | Up to 3,000 V; 95–8,000 mm² (1–45 kA) | High-chloride / hard cooling water OR closely clamped parallel bundles |
| EAF / LF Water-Cooled Cable | Bare multi-rope fluted core + bumper rings + rotating swivel head | Up to 1,500 V; 1,000–7,000 mm² | Standard treated closed-loop EAF/LF catenary electrode-arm swings |
| TF-IFL / TF-WCHC Induction Leads | Bare copper + JIC 37° swivel flare or NPT flat palms | Up to 3,000 V; 35–2,000 mm² (70–2,500 MCM) | Coreless tilting foundry induction furnaces using clean closed water |
| TF-WCP-PIPE Pipe-Connection | Detachable Type D/E pipe-contact ring & union nut | Up to 3,000 V; 300–1,480 mm² (2.9–15 kA) | Removable direct links between Ø 40–60 mm rigid water-cooled copper pipes |
In coastal mills or open cooling-tower circuits with elevated chloride ions, specifying TF-WCT-SN tin-plated copper eliminates rapid bare-strand corrosion and clogged coil passages.
TF-WCT-CLAMP Water-Cooled Cable Drawing & RFQ Checklist
- Select required option: TF-WCT-SN (tin-plated anti-chloride), TF-WCT-CL (integral rigid clamping range), or combined tin-plated + clamped build.
- Conductor cross-section (95–8,000 mm²), operating current (A), voltage (up to 3,000 V) and frequency (50/60 Hz up to 10 kHz).
- Exact overall length (mm), rigid clamping zone length a1 (260–320 mm) and exact mounting position along the span.
- Terminal palm dimensions, bolt-hole pattern, and cooling water port size/orientation (axial vs 90-degree rotated R/BSPP or NPT).
- Cooling water parameters (inlet temperature, chloride/conductivity level, available pump pressure) and splash-sleeve option.
- Order quantity in pairs or matched furnace sets (MOQ 2 pcs / 1 pair up to 1,000 mm²; 1 pc / 1 set >= 2,000 mm²; 7 to 45 working days).
Related selection resources
- Compare Standard 1,000–7,000 mm² EAF & LF Water-Cooled Cables
- Compare SAF Submerged-Arc Furnace Water-Cooled Cables
- Compare TF-IFL & TF-WCHC Foundry Induction Power Leads
- Read Technical Guide: Tinned Copper vs Bare Copper Corrosion Resistance
- Browse All Water-Cooled & High-Temperature Furnace Cables
TF-WCT-CLAMP Clamped & Tin-Plated Water-Cooled Cable FAQ
When should a plant specify TF-WCT-SN tin-plated copper instead of bare copper in a water-cooled cable?
Specify TF-WCT-SN whenever cooling water contains elevated chloride ions, dissolved oxygen, lime scale or conductivity above 50 μS/cm—common in coastal steel mills and semi-open cooling towers—because electrolytic tin plating shields fine copper wires from electrochemical pitting and green-oxide flaking.
How closely must parallel TF-WCT-CL water-cooled cables be clamped to prevent electromagnetic whipping?
Clamp parallel high-current water-cooled cables closely together every 1.5 m to 2.0 m using non-magnetic or hardwood brackets positioned directly over the integral 260–320 mm rigid clamping zone (a1) so short-circuit dynamic forces are absorbed without pinching coolant flow.
What happens if cooling water flow is interrupted on a TF-WCT-CLAMP cable at 8.4 A/mm²?
0.4 K/s is the approximate adiabatic copper temperature rise at 8.4 A/mm² current density if cooling water stops. Always wire a flow-rate and outlet-temperature monitor (<= +50 °C to +65 °C) into the furnace safety interlock to trip power immediately on coolant loss.
What insulating hose length is needed between different electrical potentials on 3,000 V water-cooled circuits?
Provide at least 1.0 m of electrically insulating coolant hose per 1,000 V AC (3.0 m minimum at 3,000 V AC) or 1.0 m per 100 V DC between energized terminals and grounded water manifolds to limit stray leakage currents and electrolytic fitting corrosion.
What is the hydrostatic test pressure, MOQ and lead time for TF-WCT-CLAMP cables?
All assemblies are factory hydrostatically tested at 8.5 to 10 bar (0.85 to 1.0 MPa) against a 6 bar operating limit. MOQ is 2 pieces (1 pair) for 95–1,000 mm² or 1 piece/set for 2,000–8,000 mm², produced in 7 to 45 working days.
TF-WCT-CL (Clamped) & TF-WCT-SN (Tin-Plated) Specification Schedule
TF-WCT-CLAMP Voltage, Tin-Plating, Clamping & Pressure Summary
- Tin-plated anti-chloride CuSn strands: 95–8,000 mm² tin-plated copper ropes stop green copper-chloride corrosion, oxygen pitting and premature strand fracture in poor or coastal water
- Integral 260–320 mm rigid clamp range: Reinforced intermediate clamping collars let saddle brackets lock parallel bundles every 1.5–2.0 m without crushing the coolant hose
- 3,000 V high-dielectric splash sheath: Flame-retardant electrically insulating coolant hose rated to 3,000 V AC with 10 bar factory hydrostatic test and molten-splash outer cover
- 8.4 A/mm² economic design + 40% margin: Sized for optimal kW-loss economics (0.7 V resistive drop over 4 m) with verified continuous overload margin and 0.4 K/s water-loss sizing data
- 2 pieces (1 pair) or 1 set MOQ: Custom-built with exact clamping zone coordinates (a1), rotated water ports and forged terminal drilling in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 3000 V AC operating voltage across electrically insulating flame-retardant outer hose |
| Conductor and section span | Tin-plated anti-chloride copper ropes 95 mm2 to 8000 mm2 (TF-WCT-SN) and clamped parallel-bundle builds 120 mm2 to 700 mm2 (TF-WCT-CL) |
| Economic loading and overload | 8.4 A/mm2 recommended economic current density with up to 40 percent continuous overload capability and 0.4 K/s adiabatic rise on coolant loss |
| Clamping zone and support spacing | 260 mm to 320 mm integral rigid clamping range (a1) engineered for 1.5 m to 2.0 m parallel saddle-clamp pitch |
| Minimum order and lead time | 2 pieces (1 pair) or 1 furnace set built to custom clamping coordinates and palm drilling in 7 to 45 working days |
| Hydrostatic test and pressure drop | 6 bar max continuous operating pressure, 8.5 to 10 bar (0.85 to 1.0 MPa) factory hydro-test, normal pressure drop up to 2 bar |
| Coolant isolation length | Minimum 1 m insulating hose per 1000 V AC or per 100 V DC between potentials; outlet water kept up to +50 C to +65 C |
TF-WCT-CL (120–700 mm²) 3,000 V Clamped Parallel-Bundle Schedule
| Model & Copper Section | 50 Hz Ref. Current (A) | Max. Operating Frequency | Clamping Range Length a1 (mm) | Hose Nom. OD (mm) | Water Port Thread | Palm Width × Thick (mm) | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-WCT-CL120 (120 mm²) | 1,000 | Up to 10 kHz | 280 | 35 | R 1/4" | 50 × 10 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL185 (185 mm²) | 1,550 | Up to 10 kHz | 310 | 41 | R 3/8" | 60 × 12 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL300 (300 mm²) | 2,500 | Up to 10 kHz | 260 | 47 | R 3/8" | 60 × 15 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL400 (400 mm²) | 3,250 | Up to 250 Hz | 300 | 54 | R 1/2" | 80 × 20 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL500 (500 mm²) | 3,780 | Up to 250 Hz | 300 | 54 | R 1/2" | 80 × 20 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL700S (700 mm²) | 5,500 | Up to 250 Hz | 300 | 66 | R 1/2" | 80 × 25 | 2 pcs (1 pair) | Request this size |
| TF-WCT-CL700L (700 mm²) | 5,500 | Up to 250 Hz | 320 | 66 | R 3/4" | 100 × 22 | 2 pcs (1 pair) | Request this size |
TF-WCT-SN (95–8,000 mm²) Tin-Plated Anti-Chloride Water-Cooled Schedule
| Model & Tin-Plated Section | 50/60 Hz Ref. Current (A) | Conductor Finish | Typical Terminal Style | Operating / Test Pressure | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|
| TF-WCT-SN95 (95 mm²) | 1,000 – 1,200 | Electrolytic Tin-Plated Cu | Flat 2-Hole / Round Head | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCT-SN300 (300 mm²) | 2,500 – 3,500 | Electrolytic Tin-Plated Cu | Flat 2/4-Hole Cu Head | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCT-SN500 (500 mm²) | 3,800 – 5,500 | Electrolytic Tin-Plated Cu | Flat 4-Hole Cu Head | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCT-SN1000 (1,000 mm²) | 6,000 – 8,400 | Electrolytic Tin-Plated Cu | Forged 4/6-Hole Palm | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCT-SN2000 (2,000 mm²) | 10,000 – 14,000 | Electrolytic Tin-Plated Cu | Forged 6/8-Hole EAF Head | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCT-SN4000 (4,000 mm²) | 18,000 – 24,000 | Electrolytic Tin-Plated Cu | Forged 8-Hole EAF Head | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCT-SN6000 (6,000 mm²) | 25,000 – 34,000 | Electrolytic Tin-Plated Cu | Forged 8/10-Hole EAF Head | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCT-SN8000 (8,000 mm²) | 34,000 – 45,000 | Electrolytic Tin-Plated Cu | Heavy Custom EAF Flange | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
Economic sizing note: At 8.4 A/mm² loading, resistive voltage drop across a 4 m cable is approximately 0.7 V; continuous current may be exceeded by up to 40% with proportionally higher resistive losses and cooling flow. Because adiabatic conductor heating reaches ~0.4 K/s upon coolant interruption, always interlock a customer cooling-water flow monitor with the furnace trip circuit. Final dimensions and clamping coordinates are confirmed on the quotation drawing.
ASCII part references for BOM and ERP entry: TF-WCT-CL120, TF-WCT-CL185, TF-WCT-CL300, TF-WCT-CL400, TF-WCT-CL500, TF-WCT-CL700S, TF-WCT-CL700L, TF-WCT-SN95, TF-WCT-SN300, TF-WCT-SN500, TF-WCT-SN1000, TF-WCT-SN2000, TF-WCT-SN4000, TF-WCT-SN6000, TF-WCT-SN8000.
TF-WCT-CLAMP Reference Conductor & Hydrostatic Standards
| Standard or specification | Application |
|---|---|
| DIN EN 13602 (Tin-Plated ETP Copper Wire) & DIN EN 13601 | Corrosion-resistant tin-plated soft-annealed copper conductor stranding paired with high-conductivity forged copper terminal heads. |
| ISO 228-1 / DIN EN 10226 (R / BSPP Threads) & 10 bar Hydrostatic Inspection | Standardized R 1/4" to R 1-1/2" axial or 90-degree rotated cooling water connections factory pressure-tested at 8.5–10 bar. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 0.85–1.0 MPa factory hydrostatic testing
DIN EN 13602 — Drawn Round Copper Wire (Bare & Tinned) for Electrical Conductors
ASTM B33 — Standard Specification for Tin-Coated Soft or Annealed Copper Wire
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²)
A related cable option for a different application or duty profile.
View productTF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA)
A related cable option for a different application or duty profile.
View productEAF & Ladle Furnace (LF) Water-Cooled Cable — 1,000–7,000 mm² Fluted-Core, Bumper & Swivel Secondary Leads
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.