High Temperature Cables TEBAOFLEX

TF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA)

TF-WCC-COMP (TF-WCC water-cooled compensator) is a heavy-duty short-span flexible water-cooled busbar expansion connector rated up to 1,500 V AC across 1,500 mm² to 10,000 mm² (6,000 A to 45,000 A at 50/60 Hz). Built with fine-stranded Cu-ETP/Cu-HCP ropes, bolted forged copper ring or plate flanges, non-magnetic AISI 304 clamping sleeves and reinforced EPDM hoses tested to 8.5–10 bar to isolate furnace transformers, delta closures and water-cooled bus tubes from thermal expansion and electromagnetic vibration.

Product information
SKU
TF-WCC-COMP
Brand
TEBAOFLEX
Product overview

TF-WCC-COMP water-cooled compensators (1,500 mm² to 10,000 mm², 6,000 A to 45,000 A at 50/60 Hz, lengths 500 mm to 2,500 mm) provide a compact, low-impedance flexible transition between rigid furnace transformer bushings, water-cooled delta closures, busbar tubes and electrode masts.

Rigid water-cooled copper pipes and bolted transformer secondary bushings expand linearly during melt cycles and experience severe 100/120 Hz electromagnetic forces during arc-furnace scrap cave-ins. Transmitting those forces directly into porcelain or epoxy transformer bushings cracks seals and loosens contact faces. TF-WCC-COMP absorbs ±15 mm to ±50 mm axial and lateral displacement using concentrically laid, ultra-fine soft-annealed Cu-ETP/Cu-HCP copper ropes around a perforated self-flushing inner core, cold-pressed without solder into forged copper ring or rectangular plate flanges and jacketed in flame-retardant EPDM/CR hose with woven fiberglass radiant-heat armor.

Specify TF-WCC-COMP when linking fixed furnace transformer secondary terminals to delta-closure copper tubes or busbar manifolds; choose EAF water-cooled cables (1,000–7,000 mm², 4–14 m catenary span) for full furnace-tilting electrode arms, or press-welded laminated copper shunts (TF-SHUNT, 100–4,500 mm²) where air-cooled dry expansion links suffice. Minimum order 1 piece or 1 matched 3-phase set, delivered in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-WCC-COMP Water-Cooled Compensator Construction

Engineered to DIN EN 13601 and ASTM B187 copper conductivity standards with non-magnetic AISI 304/316 hardware and zero soldered joints inside the high-current path.

Clean 2D engineering cross-section of TF-WCC-COMP water-cooled compensator showing central water bore, perforated core tube, dense copper rope ring, annular water jacket, reinforced EPDM hose and outer fiberglass thermal wrap
Concentric self-flushing cross-section: perforated central water core, fine-stranded copper ropes, annular cooling gap, reinforced EPDM wall and fiberglass radiant-heat shield.
TF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA) construction
ComponentMaterial and construction
1. Fine-Stranded Cu-ETP / Cu-HCP Flexible Copper Rope PackageMulti-rope concentrically laid soft-annealed electrolytic copper conductor (0.20–0.30 mm individual wires) maximizing surface-to-volume ratio for low AC skin-effect losses and high cycle life.
2. Perforated Inner Coolant Support CoreResilient perforated elastomeric core tube maintaining uniform annular spacing between ropes so forced cooling water flushes every strand bundle without stagnant hotspots.
3. Cold-Pressed Forged Copper Ring / Plate Flanges & Non-Magnetic 304 SS CollarsOne-step circumferential hydraulic compression bonds copper ropes into solid machined Cu-ETP/Cu-HCP flanges (silver- or tin-plated contact faces optional) locked by austenitic AISI 304 stud rings and mating sleeves.
4. Insulating EPDM/CR Coolant Hose & Woven Fiberglass Thermal ShieldCord-reinforced flame-retardant rubber coolant hose (6 bar working / 8.5–10 bar factory hydro-test) wrapped in high-temperature fiberglass heat-shield tape and clamped with non-magnetic stainless bands.

TF-WCC-COMP Model & Flange Configuration Breakdown

  • TF-WCC-COMP: Series identifier for TEBAOFLEX flexible water-cooled busbar expansion compensators
  • 1500 to 10000: Effective flexible copper conductor cross-section in mm² (6 kA to 45 kA at 50/60 Hz)
  • -RF / -PF: End termination code: Bolted circular Copper Ring Flange (-RF) or multi-bolt rectangular Plate Flange (-PF)
  • -SS304 / -SS316: Non-magnetic austenitic stainless steel clamping collars, stud rings and hose bands
  • -FG / -AG: Optional outer woven fiberglass heat-shield sleeve (-FG) and silver-plated flange contact faces (-AG)
Applications

TF-WCC-COMP EAF Transformer, Delta Closure & Busbar Applications

Installed across steelmaking, ferroalloy smelting and rectifier secondary circuits wherever high-current water-cooled bus systems require vibration and thermal-expansion isolation.

Twelve finished TF-WCC-COMP heavy-duty water-cooled busbar expansion compensators with bolted solid copper ring flanges and stainless steel clamping sleeves lined up inside the TEBAOFLEX manufacturing workshop
Workshop batch of completed TF-WCC-COMP bolted-flange water-cooled furnace busbar compensators inspected prior to export packing.
  • Electric Arc Furnace (EAF) and Ladle Metallurgy Furnace (LF) transformer bushing-to-delta-closure flexible water-cooled expansion links.
  • Submerged-Arc Furnace (SAF) ferroalloy, silicon metal and calcium carbide rigid water-cooled copper bus-tube expansion joints.
  • High-current DC rectifier, electrolysis cell-line and graphitizing furnace water-cooled busbar thermal compensators.
  • Electrode-mast water-cooled busbar transitions absorbing crane, hydraulic-lift and 100/120 Hz electromagnetic vibration.

TF-WCC-COMP vs EAF Catenary Cable vs Air-Cooled Laminated Shunt

TF-WCC-COMP Water-Cooled Compensator vs EAF Catenary Water-Cooled Cable vs TF-SHUNT Air-Cooled Laminated Shunt
Secondary Connector FamilyTypical Length & SectionCooling & Flange StyleWhen to Specify
TF-WCC-COMP (this page)0.5–2.5 m; 1,500–10,000 mm² (6–45 kA)Forced water-cooled; bolted Cu ring/plate flanges + 304 SS sleevesTransformer bushing to delta closure or rigid water-cooled bus tube expansion
EAF / LF Water-Cooled Cable4–14 m; 1,000–7,000 mm² (5–35 kA)Forced water-cooled; catenary loop with bumpers & swivel headsMoving furnace electrode arms requiring full tilting and roof-swing travel
TF-WCP-PIPE Pipe-Connection Cable1–6 m; 300–1,480 mm² (2.9–15 kA)Forced water-cooled; detachable Type D/E pipe-contact ring & nutDirect removable flexible jump between Ø 40–60 mm rigid water-cooled copper pipes
TF-SHUNT Laminated Copper Shunt0.2–1.5 m; 100–4,500 mm² (up to 6.2 kA)Air-cooled dry press-welded 0.1 mm copper foil stack or flat braidDry air-cooled transformer, switchgear and rectifier busbar expansion links

Never install uncooled dry laminated shunts where space envelopes restrict cross-section above 3 A/mm²; a single TF-WCC-COMP compensator replaces 4–6 parallel air-cooled shunt stacks.

TF-WCC-COMP Water-Cooled Compensator Drawing & RFQ Checklist

  • Required copper cross-section (mm²), phase operating current (kA AC or DC) and operating frequency (50/60 Hz).
  • Exact face-to-face overall length (mm) and required axial/lateral thermal-expansion movement (±mm).
  • Flange geometry on both ends: bolt-circle diameter (PCD), bolt hole count/size, stainless mating sleeve diameter, or rectangular pad sketch.
  • Coolant flow circuit: through-flow integral with busbar tubes or external side/end water ports (G/BSPP or NPT thread size).
  • Surface plating preference (bare Cu-ETP, silver-plated or tin-plated contact faces) and radiant fiberglass heat-shield requirement.
  • Order quantity in pieces or matched 3-phase sets (MOQ 1 pc / 1 set, lead time 7 to 45 working days).

Related selection resources

TF-WCC-COMP Water-Cooled Compensator Technical FAQ

Where is a TF-WCC-COMP water-cooled compensator installed in an EAF or SAF secondary circuit?

Between the stationary furnace transformer secondary bushings and the rigid water-cooled delta closure or electrode-mast copper bus tubes, absorbing 15 mm to 50 mm of thermal expansion and 100/120 Hz electromagnetic vibration that would otherwise crack transformer bushing seals.

Why does TF-WCC-COMP use non-magnetic AISI 304 stainless steel collars and bolt rings?

Yes, non-magnetic austenitic AISI 304 or 316 stainless steel is mandatory at 6 kA to 45 kA because carbon-steel clamping rings experience severe eddy-current and hysteresis induction heating inside intense alternating magnetic fields.

Can TF-WCC-COMP be manufactured to match existing European or North American furnace flange drawings?

Yes. Every TF-WCC-COMP assembly is CNC-machined from forged Cu-ETP/Cu-HCP copper to your exact bolt-circle diameter, sleeve bore, gasket groove and face-to-face length, enabling 1:1 drop-in replacement during planned furnace outages.

What hydrostatic test pressure and electrical checks are performed on TF-WCC-COMP compensators?

Factory units are hydrostatically pressure-tested at 8.5 to 10 bar (0.85 to 1.0 MPa) against a 6 bar maximum continuous operating rating and checked for conductor DC resistance using a 4-wire Kelvin micro-ohmmeter before crating.

What is the minimum order quantity and delivery lead time for TF-WCC-COMP?

1 piece or 1 matched 3-phase set (3 or 6 assemblies) custom-fabricated to your approved drawing, with typical manufacturing lead times of 7 to 45 working days depending on copper flange machining complexity.

Specifications

TF-WCC-COMP Electrical, Dimension & Flow Schedule

TF-WCC-COMP Current, Pressure, Flange & MOQ Summary

  • 1,500–10,000 mm² & 6–45 kA capacity: Compact 500–2,500 mm water-cooled flexible links engineered for high-current AC/DC furnace secondary circuits where rigid copper tubes cannot flex
  • Bolted Cu-ETP ring & plate flanges: One-step hydraulically cold-pressed conductor termination into CNC-machined 99.95% copper flanges with 8-to-12-bolt stainless stud rings
  • Non-magnetic AISI 304 clamp sleeves: Heavy austenitic stainless-steel outer clamping collars and double-band hose clamps prevent eddy-current heating at 45 kA phase currents
  • 8.5–10 bar hydro & micro-ohm verified: Factory hydrostatic pressure testing (0.85–1.0 MPa) and 4-wire Kelvin DC resistance verification before export crating
  • 1 piece or 3-phase set MOQ: Custom-built to exact flange bolt-circle diameter, face-to-face length and water-port orientation in 7 to 45 working days
TF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA) technical data
ParameterValue
Rated voltageUp to 1500 V AC or DC furnace secondary operating voltage with 5 kV to 15 kV dielectric insulating coolant hose
Cross-section and current rating1500 mm2 to 10000 mm2 flexible copper cross-section rated 6000 A to 45000 A continuous at 50/60 Hz
Flange and clamping hardwareBolted Cu-ETP or Cu-HCP circular ring flanges or multi-bolt flat bus plates with non-magnetic AISI 304 stainless clamping collars
Coolant pressure and thermal limit6 bar (0.6 MPa) continuous operating pressure, 8.5 to 10 bar (0.85 to 1.0 MPa) factory hydro-test, max outlet temperature +55 C to +65 C
Minimum order and lead time1 piece or 1 matched 3-phase set custom-machined to flange drawing in 7 to 45 working days
Assembly length and strokeTypical face-to-face span 500 mm to 2500 mm accommodating 15 mm to 50 mm axial and lateral expansion
Factory inspection workflowHydrostatic pressure hold verification and 4-wire Kelvin micro-ohm conductor DC resistance check prior to export packing

TF-WCC-COMP (1,500–10,000 mm²) Water-Cooled Compensator Schedule

TF-WCC-COMP Water-Cooled Compensator Schedule (1,500 mm² to 10,000 mm²) — 50/60 Hz Current, Flange Envelope & Coolant Flow Reference
Model & Copper Section50/60 Hz Ref. Current (A)Typical Face-to-Face Length (mm)Hose Nom. OD (mm)Flange / Collar StyleMin. Water Flow at ΔT 15 °C (L/min)Working / Test PressureAssembly MOQNext step
TF-WCC-1500 (1,500 mm²)6,000 – 7,500500 – 1,500108Bolted Cu Ring or 4-Bolt Plate25 – 356 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-2000 (2,000 mm²)8,000 – 10,000600 – 1,800120Bolted Cu Ring or 6-Bolt Plate35 – 456 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-2500 (2,500 mm²)10,000 – 12,500600 – 2,0001308-Bolt Cu Ring + 304 SS Sleeve45 – 556 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-3000 (3,000 mm²)12,000 – 15,000700 – 2,0001408-Bolt Cu Ring + 304 SS Sleeve55 – 706 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-4000 (4,000 mm²)16,000 – 20,000800 – 2,2001608/10-Bolt Cu Ring + 304 SS Sleeve70 – 906 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-5000 (5,000 mm²)20,000 – 25,000800 – 2,20017510-Bolt Cu Ring + 304 SS Sleeve90 – 1156 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-6000 (6,000 mm²)24,000 – 30,000900 – 2,50019512-Bolt Cu Ring + 304 SS Sleeve110 – 1406 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-8000 (8,000 mm²)32,000 – 38,0001,000 – 2,50022012-Bolt Cu Ring + 304 SS Sleeve145 – 1806 bar / 10 bar1 pc / 1 setRequest this size
TF-WCC-10000 (10,000 mm²)40,000 – 45,0001,000 – 2,500245Custom Heavy Bolted Ring Flange180 – 2206 bar / 10 bar1 pc / 1 setRequest this size

Current ratings reflect closed-loop filtered cooling water at 4.0 to 5.0 A/mm² continuous loading (higher current densities up to 6–8 A/mm² are supported with proportional coolant flow and ΔT <= 15–20 °C). Exact bolt-circle diameter, mating sleeve OD/ID and water-passage bore are finalized on the quotation drawing.

ASCII part references for BOM and ERP entry: TF-WCC-1500, TF-WCC-2000, TF-WCC-2500, TF-WCC-3000, TF-WCC-4000, TF-WCC-5000, TF-WCC-6000, TF-WCC-8000, TF-WCC-10000.

Standards

TF-WCC-COMP Reference Material & Thread Standards

TF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA) standards and test references
Standard or specificationApplication
DIN EN 13601 & ASTM B187High-conductivity electrolytic tough-pitch (Cu-ETP) and oxygen-free (Cu-HCP) forged/machined copper flanges and contact surfaces.
DIN EN 13602 & ISO 228-1 / ANSI B1.20.1Soft-annealed high-conductivity drawn copper wires for flexible rope stranding, paired with standard BSPP (G) or NPT cooling water ports.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and factory hydrostatic / micro-ohm inspection

ASTM B187 — Standard Specification for Copper Bar, Bus Bar, Rod and Shapes

DIN EN 13601 — Copper and Copper Alloys: Copper Rod, Bar and Wire for General Electrical Purposes

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.