TF-WCC Water-Cooled Compensator — Flexible Water-Cooled Busbar Expansion Connector (1,500–10,000 mm² / 6–45 kA)
TF-WCC-COMP (TF-WCC water-cooled compensator) is a heavy-duty short-span flexible water-cooled busbar expansion connector rated up to 1,500 V AC across 1,500 mm² to 10,000 mm² (6,000 A to 45,000 A at 50/60 Hz). Built with fine-stranded Cu-ETP/Cu-HCP ropes, bolted forged copper ring or plate flanges, non-magnetic AISI 304 clamping sleeves and reinforced EPDM hoses tested to 8.5–10 bar to isolate furnace transformers, delta closures and water-cooled bus tubes from thermal expansion and electromagnetic vibration.
TF-WCC-COMP water-cooled compensators (1,500 mm² to 10,000 mm², 6,000 A to 45,000 A at 50/60 Hz, lengths 500 mm to 2,500 mm) provide a compact, low-impedance flexible transition between rigid furnace transformer bushings, water-cooled delta closures, busbar tubes and electrode masts.
Rigid water-cooled copper pipes and bolted transformer secondary bushings expand linearly during melt cycles and experience severe 100/120 Hz electromagnetic forces during arc-furnace scrap cave-ins. Transmitting those forces directly into porcelain or epoxy transformer bushings cracks seals and loosens contact faces. TF-WCC-COMP absorbs ±15 mm to ±50 mm axial and lateral displacement using concentrically laid, ultra-fine soft-annealed Cu-ETP/Cu-HCP copper ropes around a perforated self-flushing inner core, cold-pressed without solder into forged copper ring or rectangular plate flanges and jacketed in flame-retardant EPDM/CR hose with woven fiberglass radiant-heat armor.
Specify TF-WCC-COMP when linking fixed furnace transformer secondary terminals to delta-closure copper tubes or busbar manifolds; choose EAF water-cooled cables (1,000–7,000 mm², 4–14 m catenary span) for full furnace-tilting electrode arms, or press-welded laminated copper shunts (TF-SHUNT, 100–4,500 mm²) where air-cooled dry expansion links suffice. Minimum order 1 piece or 1 matched 3-phase set, delivered in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-WCC-COMP Water-Cooled Compensator Construction
Engineered to DIN EN 13601 and ASTM B187 copper conductivity standards with non-magnetic AISI 304/316 hardware and zero soldered joints inside the high-current path.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Cu-ETP / Cu-HCP Flexible Copper Rope Package | Multi-rope concentrically laid soft-annealed electrolytic copper conductor (0.20–0.30 mm individual wires) maximizing surface-to-volume ratio for low AC skin-effect losses and high cycle life. |
| 2. Perforated Inner Coolant Support Core | Resilient perforated elastomeric core tube maintaining uniform annular spacing between ropes so forced cooling water flushes every strand bundle without stagnant hotspots. |
| 3. Cold-Pressed Forged Copper Ring / Plate Flanges & Non-Magnetic 304 SS Collars | One-step circumferential hydraulic compression bonds copper ropes into solid machined Cu-ETP/Cu-HCP flanges (silver- or tin-plated contact faces optional) locked by austenitic AISI 304 stud rings and mating sleeves. |
| 4. Insulating EPDM/CR Coolant Hose & Woven Fiberglass Thermal Shield | Cord-reinforced flame-retardant rubber coolant hose (6 bar working / 8.5–10 bar factory hydro-test) wrapped in high-temperature fiberglass heat-shield tape and clamped with non-magnetic stainless bands. |
TF-WCC-COMP Model & Flange Configuration Breakdown
- TF-WCC-COMP: Series identifier for TEBAOFLEX flexible water-cooled busbar expansion compensators
- 1500 to 10000: Effective flexible copper conductor cross-section in mm² (6 kA to 45 kA at 50/60 Hz)
- -RF / -PF: End termination code: Bolted circular Copper Ring Flange (-RF) or multi-bolt rectangular Plate Flange (-PF)
- -SS304 / -SS316: Non-magnetic austenitic stainless steel clamping collars, stud rings and hose bands
- -FG / -AG: Optional outer woven fiberglass heat-shield sleeve (-FG) and silver-plated flange contact faces (-AG)
TF-WCC-COMP EAF Transformer, Delta Closure & Busbar Applications
Installed across steelmaking, ferroalloy smelting and rectifier secondary circuits wherever high-current water-cooled bus systems require vibration and thermal-expansion isolation.

- Electric Arc Furnace (EAF) and Ladle Metallurgy Furnace (LF) transformer bushing-to-delta-closure flexible water-cooled expansion links.
- Submerged-Arc Furnace (SAF) ferroalloy, silicon metal and calcium carbide rigid water-cooled copper bus-tube expansion joints.
- High-current DC rectifier, electrolysis cell-line and graphitizing furnace water-cooled busbar thermal compensators.
- Electrode-mast water-cooled busbar transitions absorbing crane, hydraulic-lift and 100/120 Hz electromagnetic vibration.
TF-WCC-COMP vs EAF Catenary Cable vs Air-Cooled Laminated Shunt
| Secondary Connector Family | Typical Length & Section | Cooling & Flange Style | When to Specify |
|---|---|---|---|
| TF-WCC-COMP (this page) | 0.5–2.5 m; 1,500–10,000 mm² (6–45 kA) | Forced water-cooled; bolted Cu ring/plate flanges + 304 SS sleeves | Transformer bushing to delta closure or rigid water-cooled bus tube expansion |
| EAF / LF Water-Cooled Cable | 4–14 m; 1,000–7,000 mm² (5–35 kA) | Forced water-cooled; catenary loop with bumpers & swivel heads | Moving furnace electrode arms requiring full tilting and roof-swing travel |
| TF-WCP-PIPE Pipe-Connection Cable | 1–6 m; 300–1,480 mm² (2.9–15 kA) | Forced water-cooled; detachable Type D/E pipe-contact ring & nut | Direct removable flexible jump between Ø 40–60 mm rigid water-cooled copper pipes |
| TF-SHUNT Laminated Copper Shunt | 0.2–1.5 m; 100–4,500 mm² (up to 6.2 kA) | Air-cooled dry press-welded 0.1 mm copper foil stack or flat braid | Dry air-cooled transformer, switchgear and rectifier busbar expansion links |
Never install uncooled dry laminated shunts where space envelopes restrict cross-section above 3 A/mm²; a single TF-WCC-COMP compensator replaces 4–6 parallel air-cooled shunt stacks.
TF-WCC-COMP Water-Cooled Compensator Drawing & RFQ Checklist
- Required copper cross-section (mm²), phase operating current (kA AC or DC) and operating frequency (50/60 Hz).
- Exact face-to-face overall length (mm) and required axial/lateral thermal-expansion movement (±mm).
- Flange geometry on both ends: bolt-circle diameter (PCD), bolt hole count/size, stainless mating sleeve diameter, or rectangular pad sketch.
- Coolant flow circuit: through-flow integral with busbar tubes or external side/end water ports (G/BSPP or NPT thread size).
- Surface plating preference (bare Cu-ETP, silver-plated or tin-plated contact faces) and radiant fiberglass heat-shield requirement.
- Order quantity in pieces or matched 3-phase sets (MOQ 1 pc / 1 set, lead time 7 to 45 working days).
Related selection resources
- Pair with 1,000–7,000 mm² Steelmaking EAF & LF Water-Cooled Cables
- Compare SAF Submerged-Arc & Ferroalloy Water-Cooled Furnace Cables
- Compare Air-Cooled Press-Welded Laminated Copper Shunts (100–4,500 mm²)
- Explore Induction Melting & Vacuum Furnace Water-Cooled Power Leads
- Browse All High-Temperature & Furnace Water-Cooled Cables
TF-WCC-COMP Water-Cooled Compensator Technical FAQ
Where is a TF-WCC-COMP water-cooled compensator installed in an EAF or SAF secondary circuit?
Between the stationary furnace transformer secondary bushings and the rigid water-cooled delta closure or electrode-mast copper bus tubes, absorbing 15 mm to 50 mm of thermal expansion and 100/120 Hz electromagnetic vibration that would otherwise crack transformer bushing seals.
Why does TF-WCC-COMP use non-magnetic AISI 304 stainless steel collars and bolt rings?
Yes, non-magnetic austenitic AISI 304 or 316 stainless steel is mandatory at 6 kA to 45 kA because carbon-steel clamping rings experience severe eddy-current and hysteresis induction heating inside intense alternating magnetic fields.
Can TF-WCC-COMP be manufactured to match existing European or North American furnace flange drawings?
Yes. Every TF-WCC-COMP assembly is CNC-machined from forged Cu-ETP/Cu-HCP copper to your exact bolt-circle diameter, sleeve bore, gasket groove and face-to-face length, enabling 1:1 drop-in replacement during planned furnace outages.
What hydrostatic test pressure and electrical checks are performed on TF-WCC-COMP compensators?
Factory units are hydrostatically pressure-tested at 8.5 to 10 bar (0.85 to 1.0 MPa) against a 6 bar maximum continuous operating rating and checked for conductor DC resistance using a 4-wire Kelvin micro-ohmmeter before crating.
What is the minimum order quantity and delivery lead time for TF-WCC-COMP?
1 piece or 1 matched 3-phase set (3 or 6 assemblies) custom-fabricated to your approved drawing, with typical manufacturing lead times of 7 to 45 working days depending on copper flange machining complexity.
TF-WCC-COMP Electrical, Dimension & Flow Schedule
TF-WCC-COMP Current, Pressure, Flange & MOQ Summary
- 1,500–10,000 mm² & 6–45 kA capacity: Compact 500–2,500 mm water-cooled flexible links engineered for high-current AC/DC furnace secondary circuits where rigid copper tubes cannot flex
- Bolted Cu-ETP ring & plate flanges: One-step hydraulically cold-pressed conductor termination into CNC-machined 99.95% copper flanges with 8-to-12-bolt stainless stud rings
- Non-magnetic AISI 304 clamp sleeves: Heavy austenitic stainless-steel outer clamping collars and double-band hose clamps prevent eddy-current heating at 45 kA phase currents
- 8.5–10 bar hydro & micro-ohm verified: Factory hydrostatic pressure testing (0.85–1.0 MPa) and 4-wire Kelvin DC resistance verification before export crating
- 1 piece or 3-phase set MOQ: Custom-built to exact flange bolt-circle diameter, face-to-face length and water-port orientation in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 1500 V AC or DC furnace secondary operating voltage with 5 kV to 15 kV dielectric insulating coolant hose |
| Cross-section and current rating | 1500 mm2 to 10000 mm2 flexible copper cross-section rated 6000 A to 45000 A continuous at 50/60 Hz |
| Flange and clamping hardware | Bolted Cu-ETP or Cu-HCP circular ring flanges or multi-bolt flat bus plates with non-magnetic AISI 304 stainless clamping collars |
| Coolant pressure and thermal limit | 6 bar (0.6 MPa) continuous operating pressure, 8.5 to 10 bar (0.85 to 1.0 MPa) factory hydro-test, max outlet temperature +55 C to +65 C |
| Minimum order and lead time | 1 piece or 1 matched 3-phase set custom-machined to flange drawing in 7 to 45 working days |
| Assembly length and stroke | Typical face-to-face span 500 mm to 2500 mm accommodating 15 mm to 50 mm axial and lateral expansion |
| Factory inspection workflow | Hydrostatic pressure hold verification and 4-wire Kelvin micro-ohm conductor DC resistance check prior to export packing |
TF-WCC-COMP (1,500–10,000 mm²) Water-Cooled Compensator Schedule
| Model & Copper Section | 50/60 Hz Ref. Current (A) | Typical Face-to-Face Length (mm) | Hose Nom. OD (mm) | Flange / Collar Style | Min. Water Flow at ΔT 15 °C (L/min) | Working / Test Pressure | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-WCC-1500 (1,500 mm²) | 6,000 – 7,500 | 500 – 1,500 | 108 | Bolted Cu Ring or 4-Bolt Plate | 25 – 35 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-2000 (2,000 mm²) | 8,000 – 10,000 | 600 – 1,800 | 120 | Bolted Cu Ring or 6-Bolt Plate | 35 – 45 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-2500 (2,500 mm²) | 10,000 – 12,500 | 600 – 2,000 | 130 | 8-Bolt Cu Ring + 304 SS Sleeve | 45 – 55 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-3000 (3,000 mm²) | 12,000 – 15,000 | 700 – 2,000 | 140 | 8-Bolt Cu Ring + 304 SS Sleeve | 55 – 70 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-4000 (4,000 mm²) | 16,000 – 20,000 | 800 – 2,200 | 160 | 8/10-Bolt Cu Ring + 304 SS Sleeve | 70 – 90 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-5000 (5,000 mm²) | 20,000 – 25,000 | 800 – 2,200 | 175 | 10-Bolt Cu Ring + 304 SS Sleeve | 90 – 115 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-6000 (6,000 mm²) | 24,000 – 30,000 | 900 – 2,500 | 195 | 12-Bolt Cu Ring + 304 SS Sleeve | 110 – 140 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-8000 (8,000 mm²) | 32,000 – 38,000 | 1,000 – 2,500 | 220 | 12-Bolt Cu Ring + 304 SS Sleeve | 145 – 180 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
| TF-WCC-10000 (10,000 mm²) | 40,000 – 45,000 | 1,000 – 2,500 | 245 | Custom Heavy Bolted Ring Flange | 180 – 220 | 6 bar / 10 bar | 1 pc / 1 set | Request this size |
Current ratings reflect closed-loop filtered cooling water at 4.0 to 5.0 A/mm² continuous loading (higher current densities up to 6–8 A/mm² are supported with proportional coolant flow and ΔT <= 15–20 °C). Exact bolt-circle diameter, mating sleeve OD/ID and water-passage bore are finalized on the quotation drawing.
ASCII part references for BOM and ERP entry: TF-WCC-1500, TF-WCC-2000, TF-WCC-2500, TF-WCC-3000, TF-WCC-4000, TF-WCC-5000, TF-WCC-6000, TF-WCC-8000, TF-WCC-10000.
TF-WCC-COMP Reference Material & Thread Standards
| Standard or specification | Application |
|---|---|
| DIN EN 13601 & ASTM B187 | High-conductivity electrolytic tough-pitch (Cu-ETP) and oxygen-free (Cu-HCP) forged/machined copper flanges and contact surfaces. |
| DIN EN 13602 & ISO 228-1 / ANSI B1.20.1 | Soft-annealed high-conductivity drawn copper wires for flexible rope stranding, paired with standard BSPP (G) or NPT cooling water ports. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and factory hydrostatic / micro-ohm inspection
ASTM B187 — Standard Specification for Copper Bar, Bus Bar, Rod and Shapes
DIN EN 13601 — Copper and Copper Alloys: Copper Rod, Bar and Wire for General Electrical Purposes
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-BT Water-Cooled Rigid Copper Bus Tube & Furnace Transformer Delta Closure System (Ø 40–168 mm / 5–120 kA)
A related cable option for a different application or duty profile.
View productTF-EA Copper-Steel Clad Water-Cooled Current-Carrying Electrode Arm for EAF & Ladle Furnaces (15–180 t)
A related cable option for a different application or duty profile.
View productTF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.