TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²)

TF-WCP-PIPE (TF-WCP-E, TF-WCP-D and TF-WCP-HC) is a 3,000 V pipe-connection water-cooled high-current cable family spanning 525 mm² to 1,480 mm² (5,500 A to 15,000 A) with detachable copper pipe-contact rings and slotted/hex union nuts for Ø 40×6 mm to Ø 60×10 mm rigid copper bus pipes, plus 300 mm² to 1,000 mm² hollow-core threaded pipe-coupled builds up to 2,000 Hz for induction coils and polysilicon CVD reactors.

Product information
SKU
TF-WCP-PIPE
Brand
TEBAOFLEX
Product overview

TF-WCP-PIPE water-cooled pipe-connection cables (525 mm² to 1,480 mm², 5,500 A to 15,000 A at 50/60 Hz, up to 3,000 V; plus 300 mm² to 1,000 mm² hollow-core builds up to 2,000 Hz) create a detachable, leak-tight electrical and hydraulic bridge directly onto rigid water-cooled copper bus pipes (Ø 40×6 mm to Ø 60×10 mm).

In high-current induction melting banks, high-voltage circuit-breaker feeders, graphitizing installations and polysilicon Siemens CVD reactors, bolting flat lug palms onto tubular bus pipes introduces bulky adapter plates, extra water manifolds and high contact resistance. TF-WCP-PIPE eliminates adapter hardware by integrating a precision CNC-machined copper pipe-contact ring and slotted round or hexagonal union nut directly into the cable head: tightening the nut to 250–350 Nm simultaneously locks the 360-degree high-current electrical contact and seals the continuous internal cooling-water path straight through the copper tube.

Specify TF-WCP-E (Type E) when transitioning from an air-cooled flat busbar or circuit-breaker palm to a water-cooled copper pipe; specify TF-WCP-D (Type D) for removable pipe-to-pipe flexible links up to 15,000 A; specify TF-WCP-HC hollow-core pipe-threaded leads for 500–2,000 Hz medium-frequency coils requiring high coolant flow. Minimum order 2 pieces (1 pair) or 1 set, lead time 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-WCP-PIPE Pipe-Connection Water-Cooled Cable Construction

Combines cold-pressed Cu-ETP/Cu-HCP flexible conductors with precision-turned detachable pipe-contact rings, brass/copper union nuts and 3,000 V insulating hoses.

Clean 2D circular engineering cross-section of TF-WCP-PIPE hollow-core pipe-connection water-cooled cable showing central hollow cooling bore, concentric copper rope layer and reinforced high-dielectric EPDM outer hose
Hollow-core annular water-cooled geometry: high-flow central coolant bore surrounded by tightly compacted Cu-ETP copper ropes and 3,000 V hose wall.
TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²) construction
ComponentMaterial and construction
1. High-Conductivity Stranded or Hollow-Core E-Cu ConductorFine-drawn soft-annealed Cu-ETP/Cu-HCP copper ropes (DIN EN 13602) in multi-strand or hollow-core annular geometry engineered for minimal DC resistance and controlled skin-effect losses.
2. Detachable Pipe-Contact Ring & Union Nut (Type E / Type D)Precision-machined copper contact ring with slotted round nut or hexagonal swivel union nut matching Ø 40×6, 42×6, 42×7, 48×9, 50×10, 50.8×10, 58×9 and 60×10 mm water-cooled copper bus pipes.
3. 3,000 V Electrically Insulating Coolant Hose & Non-Magnetic ClampsMulti-ply flame-retardant rubber hose rated up to 3,000 V operating voltage (6 bar continuous / 10 bar factory hydro-test; pressure drop <= 2 bar under normal flow) secured by AISI 304/316 clamps.
4. Strain-Relief Hardwood / Insulated Clamp Collar ZoneNon-bendable transition collar behind the hose clips designed for insulated strain-relief clamping so mechanical cable weight never loads the copper pipe-contact ring.

TF-WCP-PIPE Type E, Type D & Hollow-Core Designation Breakdown

  • TF-WCP-E: Single-side pipe-connection water-cooled cable (one detachable pipe-contact ring + one flat busbar flange, 5,500–12,000 A)
  • TF-WCP-D: Double-side pipe-to-pipe water-cooled cable (both ends detachable copper pipe-contact rings, 6,000–15,000 A)
  • TF-WCP-HC: Medium-frequency hollow-core water-cooled cable with single- or double-side threaded copper pipe union (300–1,000 mm², up to 2 kHz)
  • 525 to 1480: Effective copper conductor cross-section in mm² matched to Ø 40×6 mm through Ø 60×10 mm copper pipes
  • -SN / -HT: Optional tin-plated anti-chloride copper strands (-SN) and molten-splash high-temperature outer shield (-HT)
Applications

TF-WCP-PIPE Rigid Copper Bus Pipe, Coil & Polysilicon Applications

Purpose-built for high-current copper pipe networks where fast service disconnection, continuous series water cooling and low voltage drop are essential.

Four-wire Kelvin micro-ohmmeter measuring DC conductor resistance across finished TF-WCP-PIPE water-cooled furnace cable assemblies fitted with machined brass-copper hexagonal union-nut pipe couplings inside the workshop
Workshop 4-wire Kelvin micro-ohm DC resistance inspection on completed TF-WCP-PIPE water-cooled cable assemblies with threaded hex pipe-union heads.
  • Removable flexible transitions between rigid Ø 40–60 mm water-cooled copper bus pipes in steelworks and non-ferrous foundries.
  • Medium-frequency induction furnace coil connections (50 Hz to 2,000 Hz) where cable coolant feeds straight through the copper coil tube.
  • Polysilicon CVD bell-jar reactor and monocrystalline silicon heater high-current water-cooled copper pipe bus systems.
  • High-current circuit-breaker, pole-changing switch and vacuum/graphitization furnace removable pipe-coupled bus links.

TF-WCP-PIPE vs Flat/JIC Induction Leads vs 10 kHz Hollow-Core

TF-WCP-PIPE Pipe-Connection Cable vs TF-IFL / TF-WCHC Flat/JIC Leads vs TF-HC10K 10 kHz Hollow-Core
Water-Cooled Cable SeriesTermination InterfaceSection & Current RangePrimary Installation Role
TF-WCP-PIPE (this page)Type E / Type D detachable copper pipe-contact ring & union nut300–1,480 mm²; 2,900–15,000 A; 50 Hz–2 kHz; 3,000 VDirect flexible link onto Ø 40–60 mm rigid water-cooled copper bus pipes
TF-IFL / TF-WCHC Induction LeadsFlat 1–8 hole palms, 45°/90° flags or #8C–#32C JIC 37° swivels35–2,000 mm² (70–2,500 MCM); 950–20,000 ACoreless tilting foundry induction furnaces and standard flat busbars
TF-HC10K / TF-WCCX HF LeadsPrecision flat/flange heads; enameled Litz or 2-pole coaxial70–1,015 mm²; up to 10 kHzHigh-frequency 2–10 kHz billet heaters and ultra-low-reactance links
TF-WCC-COMP CompensatorHeavy bolted circular copper ring flanges + 304 SS collars1,500–10,000 mm²; 6,000–45,000 AShort-span EAF/SAF transformer bushing to delta-closure expansion

Use TF-WCP-PIPE when both electrical current and cooling water must pass directly into Ø 40–60 mm rigid copper bus tubes without external adapter blocks or separate hose manifolds.

TF-WCP-PIPE Pipe-Connection Drawing & RFQ Checklist

  • Configuration required: Type E (one pipe-contact end + one flat flange), Type D (both ends pipe-contact), or TF-WCP-HC hollow-core pipe-threaded.
  • Exact mating rigid copper pipe outer diameter and wall thickness (e.g., 42×6, 48×9, 50×10, 50.8×10 or 60×10 mm) plus union nut thread spec.
  • Operating current (A), voltage (up to 3,000 V), frequency (50/60 Hz up to 2,000 Hz) and required copper cross-section (mm²).
  • Overall center-to-center assembly length (mm) and whether cable-end flat flange holes or cooling-water ports require 90-degree rotation.
  • Water quality (standard bare Cu-ETP vs tin-plated anti-chloride) and optional high-temperature splash-protection sleeve.
  • Quantity required (MOQ 2 pieces / 1 pair or 1 furnace set, lead time 7 to 45 working days).

Related selection resources

TF-WCP-PIPE Pipe-Connection Water-Cooled Cable FAQ

What is the difference between TF-WCP-PIPE Type E and Type D pipe-connection cables?

2 termination layouts define them: Type E equips one end with a detachable copper pipe-contact ring and the opposite end with a flat busbar flange (5,500–12,000 A), while Type D equips both ends with double-head pipe-contact rings to bridge two rigid water-cooled copper pipes up to 15,000 A.

What tightening torque is required on TF-WCP-PIPE slotted or hexagonal union nuts?

Tighten slotted round nuts to 250 Nm on Ø 40–42 mm pipes (525–720 mm²), 275–300 Nm on Ø 48–50.8 mm pipes (840–960 mm²), and 330–350 Nm on Ø 58–60 mm pipes (1,080–1,480 mm²) to achieve full 360-degree electrical contact and leak-tight hydraulic sealing.

Can TF-WCP-PIPE water-cooled cables run cooling water in series with the furnace induction coil?

Yes. Because TF-WCP-PIPE cooling passages are generously sized above the cable's own heat-dissipation requirement and the insulating hose is rated to 3,000 V (10 bar hydro-tested), cooling water can flow directly through the pipe contact into the furnace coil or adjacent bus tube.

Should I choose bare stranded TF-WCP-D or hollow-core TF-WCP-HC for a 1,000–2,000 Hz polysilicon or induction furnace?

Choose TF-WCP-HC hollow-core pipe-union cables above 250 Hz: hollow annular conductors suppress AC skin-effect losses and carry 2,900 A to 6,800 A continuously at 2,000 Hz while maintaining a large central coolant bore.

How are TF-WCP-PIPE assemblies tested before shipment and what is the MOQ?

Each TF-WCP-PIPE assembly undergoes 10 bar hydrostatic testing and 4-wire Kelvin micro-ohm DC resistance inspection in our workshop. Minimum order is 2 pieces (1 pair) or 1 furnace set, delivered in 7 to 45 working days.

Specifications

TF-WCP-PIPE Type E/D & Hollow-Core Current and Pipe Fit Schedule

TF-WCP-PIPE Voltage, Pipe OD, Torque & Pair MOQ Summary

  • Direct Ø 40–60 mm copper pipe coupling: Detachable conical contact-ring terminals clamp directly onto rigid water-cooled copper bus pipes (Ø 40×6 to 60×10 mm) at 250–350 Nm torque
  • Single-side Type E & double-side Type D: Choose Type E (flat flange to copper pipe, 5.5–12 kA) or Type D (pipe-to-pipe double-head coupling, 6–15 kA) for rapid coil disconnection
  • Hollow-core MF pipe-union builds: TF-WCP-HC hollow-core conductors (300–1,000 mm², up to 2,000 Hz) deliver high coolant throughput straight into induction coils or CVD electrodes
  • 3,000 V high-dielectric coolant hose: Electrically insulating flame-retardant rubber hose tested at 10 bar allows direct series coolant routing with the furnace coil
  • 2 pieces (1 pair) custom MOQ: Machined to exact mating pipe OD, union nut thread and pin-to-pipe length in 7 to 45 working days
TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²) technical data
ParameterValue
Rated voltageUp to 3000 V AC operating voltage across electrically insulating flame-retardant outer coolant hose
Cross-section and current span525 mm2 to 1480 mm2 (5500 A to 15000 A) for Type E/D pipe-contact cables and 300 mm2 to 1000 mm2 for hollow-core MF pipe unions
Mating copper pipe diameters40x6 mm, 42x6 mm, 42x7 mm, 48x9 mm, 50x10 mm, 50.8x10 mm, 58x9 mm and 60x10 mm rigid copper bus tubes
Union nut tightening torque250 Nm to 350 Nm slotted round nut or heavy hexagonal union nut torque depending on pipe size
Minimum order and lead time2 pieces (1 pair) or 1 furnace set custom-machined to copper pipe OD and length in 7 to 45 working days
Pressure and thermal limits6 bar max continuous operating pressure, 10 bar factory hydrostatic test, coolant outlet temperature up to +50 C to +65 C
Voltage-isolation hose ruleAllow at least 1 m insulating coolant hose per 1000 V AC or per 100 V DC between different electrical potentials

TF-WCP-E / TF-WCP-D (525–1,480 mm²) Pipe-Contact Water-Cooled Cable Schedule

TF-WCP-E (Single-Side) & TF-WCP-D (Double-Side) Pipe-Connection Water-Cooled High-Current Cables (525–1,480 mm², 3,000 V) — Pipe Fit & Torque Schedule
Model & Copper SectionType E Current at 50 Hz (A)Type D Current at 50 Hz (A)Mating Copper Pipe OD × Wall (mm)Hose Nom. OD (mm)Net Mass at 2,000 mm (E / D, kg)Slotted Nut Torque (Nm)Assembly MOQNext step
TF-WCP-525 (525 mm²)5,5006,00042 × 67416.8 / 19.52502 pcs (1 pair)Request this size
TF-WCP-630 (630 mm²)7,2007,90040 × 67419.0 / 21.72502 pcs (1 pair)Request this size
TF-WCP-720 (720 mm²)8,4009,00042 × 77421.0 / 23.72502 pcs (1 pair)Request this size
TF-WCP-840 (840 mm²)9,60010,50048 × 97924.1 / 27.12752 pcs (1 pair)Request this size
TF-WCP-960A (960 mm²)9,60011,50048 × 98426.9 / 30.13002 pcs (1 pair)Request this size
TF-WCP-960B (960 mm²)10,00012,00050 × 10 / 50.8 × 108427.1 / 30.53002 pcs (1 pair)Request this size
TF-WCP-1080 (1,080 mm²)11,60013,80058 × 9 / 60 × 108930.3 / 34.23302 pcs (1 pair)Request this size
TF-WCP-1295 (1,295 mm²)12,00015,00060 × 109634.8 / 39.23502 pcs (1 pair)Request this size
TF-WCP-1480 (1,480 mm²)12,00015,00060 × 109637.9 / 42.33502 pcs (1 pair)Request this size

TF-WCP-HC (300–1,000 mm²) Hollow-Core Pipe-Union Medium-Frequency Schedule

TF-WCP-HC Medium-Frequency Hollow-Core Pipe-Threaded Water-Cooled Cables (300–1,000 mm², 50 Hz to 2,000 Hz) — Frequency Derating Schedule
Model & Copper SectionCurrent at 50 Hz (A)Current at 500 Hz (A)Current at 1,000 Hz (A)Current at 2,000 Hz (A)End Coupling ConfigurationAssembly MOQNext step
TF-WCP-HC300 (300 mm²)3,7003,3003,1002,900Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size
TF-WCP-HC400 (400 mm²)4,5004,1003,8003,600Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size
TF-WCP-HC500 (500 mm²)5,5005,0004,8004,600Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size
TF-WCP-HC600 (600 mm²)6,2005,6005,4005,100Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size
TF-WCP-HC700 (700 mm²)7,1006,0005,8005,400Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size
TF-WCP-HC1000 (1,000 mm²)9,2007,8007,2006,800Single- or Double-Side Pipe Union2 pcs (1 pair)Request this size

Type E denotes single-head pipe contact (rated 5,500–12,000 A) and Type D denotes double-head pipe-to-pipe contact (rated 6,000–15,000 A). Always support the cable behind the hose clamps using insulated hardwood or fiberglass strain-relief brackets to prevent bending moments on the pipe-contact ring. Final nut thread pitch and pipe-end bevel are confirmed on the quotation drawing.

ASCII part references for BOM and ERP entry: TF-WCP-525, TF-WCP-630, TF-WCP-720, TF-WCP-840, TF-WCP-960A, TF-WCP-960B, TF-WCP-1080, TF-WCP-1295, TF-WCP-1480, TF-WCP-HC300, TF-WCP-HC400, TF-WCP-HC500, TF-WCP-HC600, TF-WCP-HC700, TF-WCP-HC1000.

Standards

TF-WCP-PIPE Reference Conductor & Thread Standards

TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²) standards and test references
Standard or specificationApplication
DIN EN 13601 & DIN EN 13602High-conductivity electrolytic copper bar/tube contact rings and fine-drawn annealed copper wire stranding.
DIN 1804 / ISO 228-1 Slotted & Hexagonal Pipe Union GeometryStandardized slotted round nut and hexagonal swivel union couplings pressure-tested at 10 bar prior to dispatch.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 4-wire Kelvin resistance / 10 bar hydro testing

DIN EN 13602 — Drawn Round Copper Wire for the Manufacture of Electrical Conductors

ISO 228-1 — Pipe Threads Where Pressure-Tight Joints Are Not Made on the Threads

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.