Welding Cables TEBAOFLEX

Class K & Class M 600 V EPDM & CPE Arc Welding & Whip Lead Cable (8 AWG–500 kcmil)

Class K & Class M 600 V Welding Cable provides North American rope-stranded bare copper secondary leads from 8 AWG through 500 kcmil for NEC Article 630 arc welders, electrode stingers and ground clamps. Engineered to ASTM B3, ASTM B172, SAE J1127, UL 1276 and ICEA S-75-381 specifications, the range pairs Class K (30 AWG strands) -50 to +105 °C halogen-free EPDM main leads with Class M (34 AWG ultra-fine strands) wrist-relief whip leads and oil/slag-resistant 90 °C thermoset CPE jackets.

Product information
SKU
TF-WELD-KM600
Brand
TEBAOFLEX
Product overview

Class K & Class M 600 V EPDM and CPE Welding Cable covers the full North American secondary welding-lead specification from 8 AWG up to 500 kcmil (304 mm² equivalent), giving structural steel fabricators, shipyards, mines and mobile welding rigs verified rope-lay copper flexibility and voltage-drop control.

In high-amperage SMAW, GMAW and FCAW circuits, choosing between Class K and Class M stranding directly governs operator wrist fatigue and jacket service life. Class K builds bundle 30 AWG (0.010 in / 0.254 mm) annealed bare copper wires—such as 1,026 strands in 1/0 AWG, 2,052 strands in 4/0 AWG and 4,921 strands in 500 kcmil—under a tear- and compression-cut-resistant -50 °C to +105 °C EPDM covering for long deck, yard and bus-box runs. Where welders manipulate the final 3 to 5 meters at the electrode holder, Class M builds step up to 34 AWG (0.0063 in / 0.160 mm) rope stranding—up to 5,225 strands in 4/0 AWG—available in -50 °C to +105 °C EPDM whip compound or heavy-duty -50 °C to +90 °C orange thermoset CPE per ICEA S-75-381 for severe cutting oil and hot slag exposure.

Select Class K EPDM for long main electrode and work-return runs, Class M EPDM for ultra-limp stinger whip extensions, or Class M CPE where hydraulic oil and spatter dominate; for 360-degree articulated spot-welding robot arms, switch to our dedicated 600 V DC robotic transgun welding cable, or specify EN 50525-2-81 H01N2-D/E where European 100/100 V metric standards apply. Bulk reel MOQ 300 m (optional cold-crimped copper lugs supplied to drawing); manufacturing lead time 7 to 45 working days.

Explore the welding cable range for related configurations.

Construction

Class K & Class M 600 V Welding Cable Construction

Single-conductor rope-lay bare copper welding lead engineered to ASTM B3, ASTM B172, SAE J1127 and ICEA S-75-381 in Class K (30 AWG) EPDM and Class M (34 AWG) EPDM/CPE configurations.

Class M 600 V orange thermoset CPE welding cable axial cross-section showing outer elastomer wall, paper separator ring and 19-rope 34 AWG bare copper core
Axial cross-section of 600 V rope-stranded Class M welding cable with thermoset CPE covering and paper separator.
Class K & Class M 600 V EPDM & CPE Arc Welding & Whip Lead Cable (8 AWG–500 kcmil) construction
ComponentMaterial and construction
1. Annealed Rope-Lay Bare Copper ConductorSoft-drawn uncoated copper per ASTM B3 & ASTM B172: Class K (30 AWG / 0.254 mm strands, 8 AWG–500 kcmil) or Class M extra-flexible (34 AWG / 0.160 mm strands, 6 AWG–4/0 AWG).
2. Easy-Strip Kraft Paper SeparatorThin longitudinal paper tape over the rope-stranded copper bundle prevents elastomer penetration and keeps strands bright for low-resistance lug crimping.
3. Option A — 105 °C EPDM Rubber Covering (Class K & Class M Whip)Halogen-free, silicone-free cross-linked EPDM composite insulation/jacket rated 600 V and -50 °C to +105 °C (-40 °C to +90 °C standard grade also available) in black or red.
4. Option B — 90 °C Oil- & Slag-Resistant Thermoset CPE Covering (Class M)High-visibility safety-orange thermoset chlorinated polyethylene (CPE-TS) compound per ICEA S-75-381 / UL 1276 design, rated 600 V and -50 °C to +90 °C.

Class K & Class M Designation & Compound Breakdown

  • Class K (30 AWG Stranding): Rope-lay bunch-stranded copper built from 0.010 in (0.254 mm) wires for heavy main welding leads and portable 600 V feeders
  • Class M (34 AWG Stranding): Ultra-fine rope-lay copper built from 0.0063 in (0.160 mm) wires—over 2.5x the strand count of Class K—for stinger whip leads and tight bends
  • EPDM (-50 to +105 °C): Ethylene propylene diene monomer thermoset rubber delivering peak cold-weather limpness, heat aging resistance and halogen-free/silicone-free cleanliness
  • CPE-TS (-50 to +90 °C): Thermoset chlorinated polyethylene composite jacket resisting petroleum oils, cutting fluids, solvents, UV and hot weld spatter
  • NEC Article 630 & SAE J1127: North American electric-welder secondary lead sizing framework and fine-wire copper stranding specification
Applications

Class K & Class M 600 V Welding Applications

Engineered for high-current secondary arc-welding circuits, stinger whip assemblies and temporary 600 V industrial power connections across harsh shop and field sites.

Class K black EPDM main welding lead coupled to an orange Class M extra-flexible electrode whip lead in a heavy structural steel welding bay
Heavy steel fabrication floor pairing a black Class K main lead with an orange Class M wrist-relief stinger whip.
  • Main electrode-holder and work-return ground leads from transformer, rectifier and inverter welders in shipyards, structural steel plants and open-pit mines.
  • Short 3 m to 5 m Class M ultra-flexible electrode whip leads coupled to heavier Class K main leads to minimize welder forearm and wrist strain.
  • Secondary resistance-welding leads, bus welding distribution boxes and NEC Article 630 welder feeder drops up to 600 V.
  • Temporary 600 V portable industrial power, load-bank jumpers, battery bank interconnects and hoist/crane cabinet leads where permitted by local code.
  • Bulk drum supply (MOQ 300 m) with optional factory-matched cold-crimped or cast copper tubular lugs per customer terminal bolt drawing.

Class K vs. Class M vs. DLO & H01N2 Selection Comparison

Class K EPDM vs. Class M Whip / CPE vs. 2 kV DLO vs. H01N2-D/E Selection Matrix
Cable FamilyConductor StrandingVoltage & Temp RatingJacket MaterialPrimary Engineering Role
Class K 600 V EPDM (TF-WELD-KM600)ASTM B172 Class K (30 AWG / 0.254 mm)600 V | -50 to +105 °CHalogen-free, silicone-free EPDMMain electrode & ground return runs (8 AWG–500 kcmil)
Class M 600 V Whip / CPE (TF-WELD-KM600)ASTM B172 Class M (34 AWG / 0.160 mm)600 V | -50 to +90 / +105 °COil/slag-resistant CPE or limp EPDM3–5 m stinger whip leads & oily shop-floor welding (6–4/0 AWG)
Robotic Transgun 600 V DC (WC 6359)Compact Class M (34 AWG) reduced-OD600 V DC | +90 °CYellow thermoset CPE360° articulated robotic spot-welding dress packs
DLO 2 kV Locomotive Cable (WC 2995)24 AWG tinned copper strands2,000 V | -40 to +90 °CTwo-layer EPR insulation + CPE jacketFixed tray/conduit feeders, traction motors & heavy switchgear
H01N2-D / H01N2-E (WC 3465)EN 50525-2-81 (0.20 / 0.15 mm metric)100/100 V | -20/-40 to +85 °CEM5 polychloroprene rubberEuropean harmonized metric arc-welding leads (10–240 mm²)

Do not interchange 24 AWG DLO crimp lugs with 30 AWG Class K or 34 AWG Class M fine-stranded copper without flared-barrel fine-strand compression dies.

Class K & Class M 600 V Welding Cable RFQ Checklist

  • Target AWG or kcmil gauge (8 AWG through 500 kcmil) and stranding class (Class K 30 AWG main run vs. Class M 34 AWG extra-flex whip).
  • Elastomer compound and jacket color (-50 to +105 °C black/red halogen-free EPDM vs. -50 to +90 °C safety-orange oil-resistant CPE).
  • Maximum welding output current (A), duty cycle (%), and total outgoing-plus-return loop length (ft or m) if engineering size verification is needed.
  • Required bulk reel footage/meterage per size (standard MOQ 300 m; 250 ft / 500 ft / 1,000 ft export reels available).
  • Optional custom-matched cold-crimped or cast copper terminal lug specifications (stud hole size, flared barrel ID, and drawing; bulk cable only by default).

Related selection resources

Class K & Class M 600 V Welding Cable FAQ

What is the difference between Class K and Class M 600 V welding cable?

Class K welding cable uses 30 AWG (0.254 mm) copper strands—such as 2,052 wires in 4/0 AWG—for rugged main runs, whereas Class M uses 2.5 times finer 34 AWG (0.160 mm) strands—5,225 wires in 4/0 AWG—delivering superior limpness for handheld electrode stinger whips and tight bends.

How many amps can Class K or Class M 4/0 AWG welding cable carry?

4/0 AWG Class K and Class M welding cable is rated for up to 600 A at a 100 ft (30 m) total circuit length (50 ft electrode + 50 ft ground at 60% duty cycle and 4 V drop), or 405 A in continuous 600 V portable free-air service per NEC Table 400.5(A)(2).

When should I choose 90 °C orange CPE over 105 °C EPDM on Class K & Class M welding cable?

Choose 105 °C EPDM when maximum sub-zero limpness (-50 °C), thermal headroom (+105 °C) and paint-shop silicone-free/halogen-free purity are paramount; choose 90 °C orange thermoset CPE when leads drag through petroleum oils, cutting coolants, solvents and heavy weld slag.

How is TEBAOFLEX Class K & Class M 600 V welding cable tested against UL 1276 and ASTM B172?

Every 300 m+ production lot is manufactured to ASTM B172, SAE J1127, UL 1276 and ICEA S-75-381 dimensional and compound specifications and verified by routine 20 °C DC conductor resistance, spark and 1.0–2.0 kV dielectric tests (third-party agency listing is not claimed).

What is the MOQ for Class K & Class M welding cable, and can you supply matching copper lugs?

300 m per conductor size is our standard bulk drum/reel MOQ with a 7 to 45 working days manufacturing lead time, and we can supply custom-matched flared-barrel cold-crimped or cast copper lugs according to your terminal bolt drawing.

Specifications

Class K & Class M 600 V Technical Specifications

Class K & Class M Key Engineering Highlights

  • Dual ASTM B172 rope-stranding classes: Class K (0.254 mm / 30 AWG wires, 8 AWG–500 kcmil) for rugged main runs and Class M (0.160 mm / 34 AWG wires, 6–4/0 AWG) for ultra-supple electrode stinger whips
  • Arctic-to-hot elastomer jacket choices: Halogen-free, silicone-free black or red EPDM (-50 °C to +105 °C) plus oil-, solvent- and weld-slag-resistant safety-orange thermoset CPE (-50 °C to +90 °C)
  • Clean paper separator for fast lugging: Internal kraft paper tape prevents rubber adhesion to fine copper strands for rapid stripping and clean cold-crimped copper lug termination
  • Complete 4/0 AWG & kcmil circuit tables: Verified strand counts (e.g., 2,052/30 in Class K 4/0 AWG and 5,225/34 in Class M 4/0 AWG) alongside 4 V drop outgoing-plus-return circuit sizing
  • 300 m bulk MOQ & matched copper lugs: Supplied in continuous bulk reels (MOQ 300 m, lead time 7 to 45 working days) with optional custom-matched cold-crimped or cast copper lugs per drawing
Class K & Class M 600 V EPDM & CPE Arc Welding & Whip Lead Cable (8 AWG–500 kcmil) technical data
ParameterValue
Rated voltage600 V AC and DC secondary welding and portable power service (engineered to UL 1276, SAE J1127 and NEC Article 630)
Operating temperature range-50 °C to +105 °C for halogen-free EPDM constructions; -50 °C to +90 °C for oil-resistant thermoset CPE constructions
Conductor strandingASTM B3 and ASTM B172 soft bare copper in Class K (30 AWG wires, 8 AWG to 500 kcmil) and Class M (34 AWG wires, 6 AWG to 4/0 AWG)
Insulation and jacketSingle-extrusion heavy-duty cross-linked EPDM (black or red) or oil- and slag-resistant thermoset CPE (orange or black) over paper separator
Flame and fluid resistanceEngineered to UL VW-1 / FT1 vertical flame test methods; CPE grade resists mineral oil, solvents, weld slag, ozone and sunlight
Minimum order and lead time300 m minimum order quantity in bulk reels (custom cold-crimped copper lugs optional per drawing); lead time 7 to 45 working days

Class K (30 AWG) 600 V EPDM Main Welding Cable Exact Dimensional Schedule

Class K (30 AWG Stranding) 600 V -50 to +105 °C EPDM Welding Cable Dimensional & Continuous Ampacity Schedule
Model & GaugeApprox. Metric (mm²)Class K Stranding (30 AWG)Wall Thickness (mm)Nominal OD (mm / in)Approx. Weight (kg/km)600V In-Line Ampacity (A)Bulk MOQNext step
Class K EPDM 8 AWG8.4168/30 (7×24)1.787.62 / 0.30012980300 mRequest this size
Class K EPDM 6 AWG13.3259/30 (7×37)1.657.75 / 0.305179105300 mRequest this size
Class K EPDM 4 AWG21.2385/30 (7×55)1.528.64 / 0.340249140300 mRequest this size
Class K EPDM 2 AWG33.6651/30 (7×93)1.7810.67 / 0.420387190300 mRequest this size
Class K EPDM 1 AWG42.4798/30 (19×42)2.1612.65 / 0.498497220300 mRequest this size
Class K EPDM 1/0 AWG53.51026/30 (19×54)2.1613.33 / 0.525612260300 mRequest this size
Class K EPDM 2/0 AWG67.41254/30 (19×66)2.1614.48 / 0.570692300300 mRequest this size
Class K EPDM 3/0 AWG85.01615/30 (19×85)2.2916.13 / 0.635918350300 mRequest this size
Class K EPDM 4/0 AWG107.22052/30 (19×108)2.0317.65 / 0.6951150405300 mRequest this size
Class K EPDM 250 kcmil1272451/30 (19×129)3.6822.22 / 0.8751510455300 mRequest this size
Class K EPDM 350 kcmil1773458/30 (19×182)3.4324.76 / 0.9751949570300 mRequest this size
Class K EPDM 500 kcmil2534921/30 (37×133)4.0629.21 / 1.1502796700300 mRequest this size

Class M (34 AWG) 600 V Extra-Flexible Whip & Oil-Resistant CPE Schedule

Class M (34 AWG Extra-Flexible) 600 V CPE & EPDM Whip Lead Dimensional Schedule
Model & GaugeApprox. Metric (mm²)Class M Stranding (34 AWG)Compound OptionsNominal OD (mm / in)Approx. Weight (kg/km)Continuous Ampacity (A)Bulk MOQNext step
Class M Whip 6 AWG13.3660/3490 °C CPE / 105 °C EPDM9.40 / 0.370186105300 mRequest this size
Class M Whip 4 AWG21.21045/3490 °C CPE / 105 °C EPDM10.80 / 0.425284140300 mRequest this size
Class M Whip 2 AWG33.61634/34 (or 1482/34)90 °C CPE / 105 °C EPDM12.07 / 0.475385190300 mRequest this size
Class M Whip 1 AWG42.42090/34 (or 1843/34)90 °C CPE / 105 °C EPDM13.46 / 0.530493220300 mRequest this size
Class M Whip 1/0 AWG53.52597/34 (or 2337/34)90 °C CPE / 105 °C EPDM14.61 / 0.575597260300 mRequest this size
Class M Whip 2/0 AWG67.43300/34 (or 2886/34)90 °C CPE / 105 °C EPDM16.00 / 0.630760300300 mRequest this size
Class M Whip 3/0 AWG85.04214/3490 °C Oil-Resistant CPE17.78 / 0.700915350300 mRequest this size
Class M Whip 4/0 AWG107.25225/3490 °C Oil-Resistant CPE20.32 / 0.8001256405300 mRequest this size

Class K & Class M Secondary Welding Circuit AWG Sizing Chart (60% Duty Cycle, 4 V Drop)

Recommended AWG Welding Cable Size by Amperage & Total Circuit Length (Outgoing + Return Lead, 4 V Drop, 60% Duty Cycle)
Welding Current (A)100 ft (30 m) Total150 ft (46 m) Total200 ft (61 m) Total250 ft (76 m) Total300 ft (91 m) Total350–400 ft (107–122 m)
100 A Welder Output4 AWG4 AWG2 AWG2 AWG1 AWG1/0 AWG
150 A Welder Output4 AWG2 AWG1 AWG1/0 AWG2/0 AWG3/0 AWG
200 A Welder Output2 AWG1 AWG1/0 AWG2/0 AWG3/0 AWG4/0 AWG
250 A Welder Output1 AWG1/0 AWG2/0 AWG3/0 AWG4/0 AWG250 kcmil
300 A Welder Output1/0 AWG2/0 AWG3/0 AWG4/0 AWG250 kcmil350 kcmil
350–400 A Welder Output2/0 AWG3/0 AWG4/0 AWG250 kcmil350 kcmil500 kcmil
450–500 A Welder Output3/0 AWG4/0 AWG250 kcmil350 kcmil500 kcmilParallel 4/0 AWG
550–600 A Welder Output4/0 AWG250 kcmil350 kcmil500 kcmilParallel 4/0 AWGParallel 250 kcmil

Continuous portable-cable ampacities reference NEC Table 400.5(A)(2) (single-conductor free-air basis); secondary welding-lead AWG recommendations assume 60% duty cycle, 40 °C ambient and maximum 4 V total loop voltage drop across electrode plus ground leads.

Manufactured to ASTM B172, SAE J1127, UL 1276 and ICEA S-75-381 dimensional and performance specifications (third-party agency listing is not claimed). Custom sequentially marked footage/meter legends and extruded color stripes available.

ASCII part references for BOM and ERP entry: TF-WELD-K-8AWG, TF-WELD-K-6AWG, TF-WELD-K-4AWG, TF-WELD-K-2AWG, TF-WELD-K-1AWG, TF-WELD-K-1/0, TF-WELD-K-2/0, TF-WELD-K-3/0, TF-WELD-K-4/0, TF-WELD-K-250MCM, TF-WELD-K-350MCM, TF-WELD-K-500MCM, TF-WELD-M-2AWG, TF-WELD-M-1/0, TF-WELD-M-2/0, TF-WELD-M-4/0.

Standards

Class K & Class M Standards & Test References

Class K & Class M 600 V EPDM & CPE Arc Welding & Whip Lead Cable (8 AWG–500 kcmil) standards and test references
Standard or specificationApplication
ASTM B3 & ASTM B172Annealed uncoated copper wire and Class K (30 AWG) / Class M (34 AWG) rope-lay bunch-stranded conductor specifications.
SAE J1127 & ICEA S-75-381 (NEMA WC 58)North American copper stranding, thermoset EPDM and chlorinated polyethylene (CPE) portable/welding elastomer performance references.
UL 1276 & NFPA 70 (NEC Article 630)Design and dimensional construction reference for 600 V arc-welding cables and electric-welder secondary lead sizing.
UL 2556 VW-1 / CSA FT1 Test ReferenceVertical flame-retardance test reference for single-conductor elastomer welding leads.

ASTM B172 Rope-Lay-Stranded Copper Conductors (Class K & Class M)

NFPA 70 (NEC Article 630) Electric Welders Secondary Circuit Rules

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.