FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable
FM2XH, FM2XCH, FM2XCCH, FM2XAH and FM2XAAH (-FFR) unify the complete IEC 60092-376 150/250 V halogen-free marine instrumentation, radar and communication twisted-pair series: unscreened (FM2XH), overall copper braid (FM2XCH), individual + overall copper braid (FM2XCCH), overall Al-PES foil + drain (FM2XAH), individual + overall Al-PES foil PiMF (FM2XAAH) and -FFR mica fire-resistant versions—built with 0.5–2.5 mm² stranded copper, XLPE insulation and grey or orange SHF1 sheathing.
FM2XH, FM2XCH, FM2XCCH, FM2XAH and FM2XAAH (-FFR) cover the full European 150/250 V shipboard instrumentation and communication matrix under IEC 60092-376: unscreened multi-core/pair (FM2XH), collective copper wire braid (FM2XCH), individual pair copper braids plus collective copper braid (FM2XCCH), collective aluminum-polyester foil with tinned drain wire (FM2XAH), individual pair aluminum-polyester foils plus collective foil screen (FM2XAAH) and their corresponding -FFR mica fire-resistant counterparts.
Modern bridge automation, radar displays, engine-room PLC/SCADA sensors, fire-detection loops and public-address / general-alarm (PA/GA) systems share tight deckhead trays directly alongside high-current VFD and generator feeders. Matching the exact screen letter code eliminates noise without over-specifying diameter: FM2XAH and FM2XAAH use lightweight aluminum-polyester foils for clean high-frequency crosstalk rejection on 4–20 mA analog and RS-485 telemetry, whereas FM2XCH and FM2XCCH add braided copper shields where low-frequency magnetic coupling and mechanical ruggedness dominate. Adding -FFR wraps mica fire-barrier tape over every conductor so life-safety voice and alarm signals survive direct flame.
Specify FM2X series cables for commercial shipboard instrumentation and communication trays (grey SHF1 standard, blue for intrinsically safe Ex-i circuits, orange for -FFR fire survival); choose NEK 606 RFOU(i)/(c) or BFOU(i)/(c) for mud-exposed offshore drilling platforms, or marine Cat6A/Cat7 Ethernet for high-speed shipboard LANs. Minimum order 50 m; lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
FM2XH, FM2XCH & FM2XAAH (-FFR) Twisted-Pair Construction
Precision twisted-pair or multi-core 150/250 V marine instrumentation cable with modular foil/braid screen tiers, optional mica fire barrier and SHF1 halogen-free outer sheath.

| Component | Material and construction |
|---|---|
| 1. Stranded Copper Conductor (0.5–2.5 mm², Bare or Tinned) | IEC 60228 Class 2 or flexible Class 5 electrolytic copper strands engineered for clean ferruling inside dense marine automation terminals. |
| 2. Optional Phlogopite Mica Fire Barrier (-FFR Versions) | Overlapping mica glass tape directly over each conductor on FM2XCH-FFR, FM2XCCH-FFR, FM2XAH-FFR and FM2XAAH-FFR for IEC 60331 circuit integrity. |
| 3. 90 °C XLPE Insulation & Short-Pitch Pair / Triple Twisting | Low-capacitance XLPE insulation color/number-coded per IEC 60092-376, laid up in short-pitch twisted pairs or triples to cancel inductive interference. |
| 4. Modular Individual & Overall Shielding (A / AA / C / CC) | Al-PES foil + tinned drain wire (A/AA) or minimum 85–90% copper wire braid (C/CC), individually per pair and/or collectively over the laid-up core. |
| 5. Grey, Blue (Ex-i) or Orange (-FFR) SHF1 Halogen-Free Jacket | Flame-retardant (IEC 60332-3-22 Cat. A), zero-halogen (IEC 60754), low-smoke (IEC 61034) polyolefin outer sheath rated -40 °C to +90 °C. |
FM2X Marine Communication Screen & Fire-Code Breakdown
- F: Fernmelde / telecommunication, instrumentation and control cable design (150/250 V, IEC 60092-376)
- M2X: Marine shipboard cable (M) with 90 °C cross-linked polyethylene (2X) insulation
- A / AA / C / CC: A = overall Al foil; AA = ind.+overall Al foil; C = overall Cu braid; CC = ind.+overall Cu braid; blank = unscreened
- H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath
- -FFR: Optional phlogopite mica glass fire-barrier tape rated for IEC 60331 emergency circuit integrity
FM2XH, FM2XCH & FM2XAAH Bridge, Radar & SCADA Applications
Engineered for shipboard communication, navigation, alarm, monitoring and process-control networks across dry, wet and machinery spaces.

- Ship navigation bridge radar, ECDIS, gyrocompass, autopilot, echo-sounder and voyage-data-recorder (VDR) telemetry.
- Engine-room PLC/SCADA instrumentation, 4–20 mA pressure/temperature/level transmitters and main-engine alarm monitoring.
- Fire-detection zones, gas-detection sensors, public-address / general-alarm (PA/GA) speakers and emergency intercoms (-FFR versions).
- Intrinsically safe (Ex-i) tank-gauging and cargo-monitoring loops using blue-jacketed FM2XAAH individually screened pairs.
FM2XAAH / FM2XCH vs DIN 89159 FMGCG vs Marine Fieldbus
| Cable Family | Shielding & Dielectric | Voltage / Signal | Primary Marine Application |
|---|---|---|---|
| FM2XAH / FM2XAAH / FM2XCH (this page) | Al foil and/or Cu braid, XLPE/SHF1 | 150/250 V analog & digital | Bridge telemetry, PLC/SCADA, PA/GA & fire detection |
| FMGCG / FMGCH (DIN 89159/89160) | 90% Cu braid, HEPR/SE1 or SHF1 | 150/250 V rubber/LSZH | Classic European ship refits specifying DIN 89159 |
| Marine Fieldbus (PROFIBUS / RS-485) | 120–150 Ω controlled impedance | High-speed serial bus | Deterministic marine fieldbus & CAN/NMEA trunks |
| Marine Cat5e / Cat6A / Cat7 | 100 Ω S/FTP high-MHz | 1–10 Gbps Ethernet | Shipboard IP cameras, VoIP & bridge LAN backbones |
Choose FM2XAAH (individual + overall foil) whenever mixed 4–20 mA analog sensors share a multi-pair cable to prevent pair-to-pair crosstalk.
FM2X Marine Communication & Instrumentation RFQ Checklist
- Exact screen code: FM2XH (unscreened), FM2XAH (overall foil), FM2XAAH (individual + overall foil), FM2XCH (overall Cu braid) or FM2XCCH (ind. + overall Cu braid).
- Standard flame-retardant vs fire-resistant (-FFR mica tape to IEC 60331).
- Pair/triple/core count and conductor size (0.5, 0.75, 1.0, 1.5 or 2.5 mm², bare or tinned, Class 2 or Class 5).
- Outer SHF1 jacket color (grey standard, blue Ex-i or orange -FFR) and order length (MOQ 50 m; lead time 7 to 45 working days).
Related selection resources
- Explore General IEC 60092-376 150/250 V Shipboard Control Cables
- Pair with M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Power Cables
- Explore Controlled-Impedance Marine Fieldbus (PROFIBUS / CAN / RS-485) Cables
- Explore Halogen-Free Cat5e–Cat7 Shipboard Marine Ethernet Cables
- Browse Complete Marine & Offshore Shipboard Cable Catalog
- Explore Shipboard & Offshore Marine Cable Solutions Hub
FM2XH, FM2XCH & FM2XAAH Marine Signal Cable FAQ
What is the difference between FM2XAH, FM2XAAH, FM2XCH and FM2XCCH marine cables?
The letters between 2X and H encode the screen architecture: A = overall aluminum-polyester foil, AA = individual pair foils plus overall foil, C = overall copper wire braid, and CC = individual pair copper braids plus overall copper braid.
When should I specify FM2XAAH-FFR instead of standard FM2XAAH?
Specify FM2XAAH-FFR whenever the 150/250 V twisted-pair circuit feeds SOLAS life-safety systems—such as fire detection loops, emergency PA/GA speakers, gas alarms or watertight door status—where IEC 60331 signal continuity during fire is mandatory.
Can FM2XAAH and FM2XCH be supplied with blue jackets for intrinsically safe (Ex-i) zones?
Yes. All FM2X variants can be extruded with RAL 5015 blue SHF1 halogen-free outer jackets for intrinsically safe instrumentation separation aboard tankers and LNG carriers.
What is the difference between FM2XH multi-core and FM2XCH twisted-pair cables?
FM2XH multi-core lays 150/250 V single conductors concentrically without a metallic screen for basic low-voltage indication circuits, whereas FM2XCH twists conductors in pairs and wraps them in a copper wire braid to reject both inductive crosstalk and radiated engine-room EMI.
What is the MOQ and production lead time for FM2X marine communication cables?
50 m minimum order per size and screen variant, custom-manufactured in 7 to 45 working days.
FM2XH, FM2XCH & FM2XAAH (-FFR) Dimension Schedule
FM2X Electrical, Shielding & Fire-Survival Ratings
- Five complete EMC screening tiers: Unscreened (FM2XH), overall Cu braid (FM2XCH), individual+overall Cu braid (FM2XCCH), overall foil (FM2XAH) and individual+overall foil (FM2XAAH)
- Optional -FFR mica fire-survival tier: FM2XCH-FFR, FM2XCCH-FFR, FM2XAH-FFR and FM2XAAH-FFR add phlogopite mica tapes for IEC 60331 emergency fire-alarm and PA/GA loops
- Twisted-pair & multi-core signal fidelity: Tightly twisted pairs and triples (1 to 37 pairs/cores across 0.5, 0.75, 1.0, 1.5 and 2.5 mm²) reject adjacent-pair crosstalk
- IEC 60092-376 150/250 V rating: 1.5 kV AC routine test voltage, -40 °C to +90 °C operating range, SHF1 zero-halogen low-smoke flame-retardant jacket
- 50 m MOQ in grey, blue (Ex-i) or orange (-FFR): Class 2 or flexible Class 5 bare/tinned copper conductors custom-manufactured in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 150/250 V AC (IEC 60092-376), 1.5 kV AC routine test voltage |
| Screening configurations | Unscreened (H), collective Al foil (AH), ind.+coll. Al foil (AAH), collective Cu braid (CH), ind.+coll. Cu braid (CCH) |
| Fire-survival option (-FFR) | Overlapping mica glass tape fire barrier designed to IEC 60331 for emergency alarm and PA/GA circuits |
| Operating temperature range | -40 °C to +90 °C fixed service (-15 °C minimum installation; 6 × D minimum bending radius) |
| Size range and sheath colors | 1 to 37 pairs/triples/cores (0.5, 0.75, 1.0, 1.5, 2.5 mm²); grey standard, blue (Ex-i) or orange (-FFR) SHF1 sheath |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
FM2XH, FM2XCH & FM2XAAH (-FFR) 150/250 V Dimension Schedule
| Model & Size (mm²) | Layout | Shielding & Fire Tier | Nominal OD (mm) | Approx. Weight (kg/km) | Sheath Color | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| FM2XH 7×0.75 | 7C × 0.75 | Unscreened Multi-Core | 10.2 | 135 | Grey SHF1 | 50 m | Request this size |
| FM2XCH 2×2×0.75 | 2P × 0.75 | Overall Cu Braid | 11.4 | 170 | Grey SHF1 | 50 m | Request this size |
| FM2XCH 7×2×0.75 | 7P × 0.75 | Overall Cu Braid | 15.8 | 345 | Grey SHF1 | 50 m | Request this size |
| FM2XCCH 4×2×0.75 | 4P × 0.75 | Ind. + Overall Cu Braid | 15.6 | 340 | Grey SHF1 | 50 m | Request this size |
| FM2XAH 4×2×0.75 | 4P × 0.75 | Overall Al-PES Foil | 12.2 | 175 | Grey / Blue SHF1 | 50 m | Request this size |
| FM2XAAH 4×2×0.75 | 4P × 0.75 | Ind. + Overall Al Foil | 13.4 | 205 | Grey / Blue SHF1 | 50 m | Request this size |
| FM2XAAH 12×2×0.75 | 12P × 0.75 | Ind. + Overall Al Foil | 20.8 | 485 | Grey / Blue SHF1 | 50 m | Request this size |
| FM2XAAH 7×2×1.5 | 7P × 1.5 | Ind. + Overall Al Foil | 19.8 | 490 | Grey / Blue SHF1 | 50 m | Request this size |
| FM2XCH-FFR 2×2×0.75 | 2P × 0.75 | Mica + Overall Cu Braid | 13.2 | 220 | Orange SHF1 | 50 m | Request this size |
| FM2XAAH-FFR 2×2×0.75 | 2P × 0.75 | Mica + Ind./Coll. Foil | 13.8 | 225 | Orange SHF1 | 50 m | Request this size |
| FM2XAAH-FFR 4×2×1.5 | 4P × 1.5 | Mica + Ind./Coll. Foil | 19.2 | 445 | Orange SHF1 | 50 m | Request this size |
| FM2XAAH-FFR 12×2×0.75 | 12P × 0.75 | Mica + Ind./Coll. Foil | 24.6 | 640 | Orange SHF1 | 50 m | Request this size |
Single-pair, 2-pair, 4-pair, 7-pair, 10-pair, 12-pair, 19-pair, 24-pair and 37-pair counts as well as twisted triples (3×) and multi-core builds are manufactured across 0.5 mm² to 2.5 mm². Blue SHF1 outer jackets are supplied on request for intrinsically safe Ex-i separation.
ASCII part references for BOM and ERP entry: FM2XH-7x0.75, FM2XCH-2x2x0.75, FM2XCH-7x2x0.75, FM2XCCH-4x2x0.75, FM2XAH-4x2x0.75, FM2XAAH-4x2x0.75, FM2XAAH-12x2x0.75, FM2XAAH-7x2x1.5, FM2XCH-FFR-2x2x0.75, FM2XAAH-FFR-2x2x0.75, FM2XAAH-FFR-4x2x1.5, FM2XAAH-FFR-12x2x0.75.
FM2X IEC 60092-376 & IEC 60331 Marine Signal Standards
| Standard or specification | Application |
|---|---|
| IEC 60092-376 | Design reference for 150/250 V (300 V) shipboard cables for control and instrumentation circuits. |
| IEC 60331-1 / -2 / -21 (-FFR Series) | Circuit integrity under fire design reference for emergency shipboard communication and alarm cabling. |
| IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2 | Bunched vertical flame retardance, zero-halogen corrosivity and low smoke density reference. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing and routine quality documentation
IEC 60332-3-22 — Bunched Cable Vertical Flame Spread Test (Category A)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331)
A related cable option for a different application or duty profile.
View productM2XH, M2XCH & M2XSH 0.6/1 kV Halogen-Free Shipboard Power Cable (IEC 60092-353)
A related cable option for a different application or duty profile.
View productMGCG, FMGCG, MGG & MGCH (-FFR) DIN 89158 / 89159 / 89160 Marine Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.