Marine & Offshore Cables TEBAOFLEX

FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable

FM2XH, FM2XCH, FM2XCCH, FM2XAH and FM2XAAH (-FFR) unify the complete IEC 60092-376 150/250 V halogen-free marine instrumentation, radar and communication twisted-pair series: unscreened (FM2XH), overall copper braid (FM2XCH), individual + overall copper braid (FM2XCCH), overall Al-PES foil + drain (FM2XAH), individual + overall Al-PES foil PiMF (FM2XAAH) and -FFR mica fire-resistant versions—built with 0.5–2.5 mm² stranded copper, XLPE insulation and grey or orange SHF1 sheathing.

Product information
SKU
TF-FM2X-250V
Brand
TEBAOFLEX
Product overview

FM2XH, FM2XCH, FM2XCCH, FM2XAH and FM2XAAH (-FFR) cover the full European 150/250 V shipboard instrumentation and communication matrix under IEC 60092-376: unscreened multi-core/pair (FM2XH), collective copper wire braid (FM2XCH), individual pair copper braids plus collective copper braid (FM2XCCH), collective aluminum-polyester foil with tinned drain wire (FM2XAH), individual pair aluminum-polyester foils plus collective foil screen (FM2XAAH) and their corresponding -FFR mica fire-resistant counterparts.

Modern bridge automation, radar displays, engine-room PLC/SCADA sensors, fire-detection loops and public-address / general-alarm (PA/GA) systems share tight deckhead trays directly alongside high-current VFD and generator feeders. Matching the exact screen letter code eliminates noise without over-specifying diameter: FM2XAH and FM2XAAH use lightweight aluminum-polyester foils for clean high-frequency crosstalk rejection on 4–20 mA analog and RS-485 telemetry, whereas FM2XCH and FM2XCCH add braided copper shields where low-frequency magnetic coupling and mechanical ruggedness dominate. Adding -FFR wraps mica fire-barrier tape over every conductor so life-safety voice and alarm signals survive direct flame.

Specify FM2X series cables for commercial shipboard instrumentation and communication trays (grey SHF1 standard, blue for intrinsically safe Ex-i circuits, orange for -FFR fire survival); choose NEK 606 RFOU(i)/(c) or BFOU(i)/(c) for mud-exposed offshore drilling platforms, or marine Cat6A/Cat7 Ethernet for high-speed shipboard LANs. Minimum order 50 m; lead time 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

FM2XH, FM2XCH & FM2XAAH (-FFR) Twisted-Pair Construction

Precision twisted-pair or multi-core 150/250 V marine instrumentation cable with modular foil/braid screen tiers, optional mica fire barrier and SHF1 halogen-free outer sheath.

Clean 2D technical cross-section of 4-pair FM2XAAH 150/250 V marine communication cable showing grey SHF1 outer sheath, tinned copper braid and overall aluminum foil around four individually silver-foil-screened twisted pairs
4-pair FM2XAAH cross-section showing individual pair foil screens inside collective shielding for crosstalk-free shipboard telemetry.
FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable construction
ComponentMaterial and construction
1. Stranded Copper Conductor (0.5–2.5 mm², Bare or Tinned)IEC 60228 Class 2 or flexible Class 5 electrolytic copper strands engineered for clean ferruling inside dense marine automation terminals.
2. Optional Phlogopite Mica Fire Barrier (-FFR Versions)Overlapping mica glass tape directly over each conductor on FM2XCH-FFR, FM2XCCH-FFR, FM2XAH-FFR and FM2XAAH-FFR for IEC 60331 circuit integrity.
3. 90 °C XLPE Insulation & Short-Pitch Pair / Triple TwistingLow-capacitance XLPE insulation color/number-coded per IEC 60092-376, laid up in short-pitch twisted pairs or triples to cancel inductive interference.
4. Modular Individual & Overall Shielding (A / AA / C / CC)Al-PES foil + tinned drain wire (A/AA) or minimum 85–90% copper wire braid (C/CC), individually per pair and/or collectively over the laid-up core.
5. Grey, Blue (Ex-i) or Orange (-FFR) SHF1 Halogen-Free JacketFlame-retardant (IEC 60332-3-22 Cat. A), zero-halogen (IEC 60754), low-smoke (IEC 61034) polyolefin outer sheath rated -40 °C to +90 °C.

FM2X Marine Communication Screen & Fire-Code Breakdown

  • F: Fernmelde / telecommunication, instrumentation and control cable design (150/250 V, IEC 60092-376)
  • M2X: Marine shipboard cable (M) with 90 °C cross-linked polyethylene (2X) insulation
  • A / AA / C / CC: A = overall Al foil; AA = ind.+overall Al foil; C = overall Cu braid; CC = ind.+overall Cu braid; blank = unscreened
  • H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath
  • -FFR: Optional phlogopite mica glass fire-barrier tape rated for IEC 60331 emergency circuit integrity
Applications

FM2XH, FM2XCH & FM2XAAH Bridge, Radar & SCADA Applications

Engineered for shipboard communication, navigation, alarm, monitoring and process-control networks across dry, wet and machinery spaces.

Modern ship navigation bridge automation console rear cabinet showing neatly dressed grey FM2XAAH and FM2XCH screened marine communication cables on bulkhead racks
Vessel navigation bridge and automation cabinet wired with grey halogen-free FM2XCH and FM2XAAH marine signal cables.
  • Ship navigation bridge radar, ECDIS, gyrocompass, autopilot, echo-sounder and voyage-data-recorder (VDR) telemetry.
  • Engine-room PLC/SCADA instrumentation, 4–20 mA pressure/temperature/level transmitters and main-engine alarm monitoring.
  • Fire-detection zones, gas-detection sensors, public-address / general-alarm (PA/GA) speakers and emergency intercoms (-FFR versions).
  • Intrinsically safe (Ex-i) tank-gauging and cargo-monitoring loops using blue-jacketed FM2XAAH individually screened pairs.

FM2XAAH / FM2XCH vs DIN 89159 FMGCG vs Marine Fieldbus

FM2XAAH / FM2XCH vs Classic FMGCG (DIN 89159) vs Marine Fieldbus / Ethernet
Cable FamilyShielding & DielectricVoltage / SignalPrimary Marine Application
FM2XAH / FM2XAAH / FM2XCH (this page)Al foil and/or Cu braid, XLPE/SHF1150/250 V analog & digitalBridge telemetry, PLC/SCADA, PA/GA & fire detection
FMGCG / FMGCH (DIN 89159/89160)90% Cu braid, HEPR/SE1 or SHF1150/250 V rubber/LSZHClassic European ship refits specifying DIN 89159
Marine Fieldbus (PROFIBUS / RS-485)120–150 Ω controlled impedanceHigh-speed serial busDeterministic marine fieldbus & CAN/NMEA trunks
Marine Cat5e / Cat6A / Cat7100 Ω S/FTP high-MHz1–10 Gbps EthernetShipboard IP cameras, VoIP & bridge LAN backbones

Choose FM2XAAH (individual + overall foil) whenever mixed 4–20 mA analog sensors share a multi-pair cable to prevent pair-to-pair crosstalk.

FM2X Marine Communication & Instrumentation RFQ Checklist

  • Exact screen code: FM2XH (unscreened), FM2XAH (overall foil), FM2XAAH (individual + overall foil), FM2XCH (overall Cu braid) or FM2XCCH (ind. + overall Cu braid).
  • Standard flame-retardant vs fire-resistant (-FFR mica tape to IEC 60331).
  • Pair/triple/core count and conductor size (0.5, 0.75, 1.0, 1.5 or 2.5 mm², bare or tinned, Class 2 or Class 5).
  • Outer SHF1 jacket color (grey standard, blue Ex-i or orange -FFR) and order length (MOQ 50 m; lead time 7 to 45 working days).

Related selection resources

FM2XH, FM2XCH & FM2XAAH Marine Signal Cable FAQ

What is the difference between FM2XAH, FM2XAAH, FM2XCH and FM2XCCH marine cables?

The letters between 2X and H encode the screen architecture: A = overall aluminum-polyester foil, AA = individual pair foils plus overall foil, C = overall copper wire braid, and CC = individual pair copper braids plus overall copper braid.

When should I specify FM2XAAH-FFR instead of standard FM2XAAH?

Specify FM2XAAH-FFR whenever the 150/250 V twisted-pair circuit feeds SOLAS life-safety systems—such as fire detection loops, emergency PA/GA speakers, gas alarms or watertight door status—where IEC 60331 signal continuity during fire is mandatory.

Can FM2XAAH and FM2XCH be supplied with blue jackets for intrinsically safe (Ex-i) zones?

Yes. All FM2X variants can be extruded with RAL 5015 blue SHF1 halogen-free outer jackets for intrinsically safe instrumentation separation aboard tankers and LNG carriers.

What is the difference between FM2XH multi-core and FM2XCH twisted-pair cables?

FM2XH multi-core lays 150/250 V single conductors concentrically without a metallic screen for basic low-voltage indication circuits, whereas FM2XCH twists conductors in pairs and wraps them in a copper wire braid to reject both inductive crosstalk and radiated engine-room EMI.

What is the MOQ and production lead time for FM2X marine communication cables?

50 m minimum order per size and screen variant, custom-manufactured in 7 to 45 working days.

Specifications

FM2XH, FM2XCH & FM2XAAH (-FFR) Dimension Schedule

FM2X Electrical, Shielding & Fire-Survival Ratings

  • Five complete EMC screening tiers: Unscreened (FM2XH), overall Cu braid (FM2XCH), individual+overall Cu braid (FM2XCCH), overall foil (FM2XAH) and individual+overall foil (FM2XAAH)
  • Optional -FFR mica fire-survival tier: FM2XCH-FFR, FM2XCCH-FFR, FM2XAH-FFR and FM2XAAH-FFR add phlogopite mica tapes for IEC 60331 emergency fire-alarm and PA/GA loops
  • Twisted-pair & multi-core signal fidelity: Tightly twisted pairs and triples (1 to 37 pairs/cores across 0.5, 0.75, 1.0, 1.5 and 2.5 mm²) reject adjacent-pair crosstalk
  • IEC 60092-376 150/250 V rating: 1.5 kV AC routine test voltage, -40 °C to +90 °C operating range, SHF1 zero-halogen low-smoke flame-retardant jacket
  • 50 m MOQ in grey, blue (Ex-i) or orange (-FFR): Class 2 or flexible Class 5 bare/tinned copper conductors custom-manufactured in 7 to 45 working days
FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable technical data
ParameterValue
Rated voltage150/250 V AC (IEC 60092-376), 1.5 kV AC routine test voltage
Screening configurationsUnscreened (H), collective Al foil (AH), ind.+coll. Al foil (AAH), collective Cu braid (CH), ind.+coll. Cu braid (CCH)
Fire-survival option (-FFR)Overlapping mica glass tape fire barrier designed to IEC 60331 for emergency alarm and PA/GA circuits
Operating temperature range-40 °C to +90 °C fixed service (-15 °C minimum installation; 6 × D minimum bending radius)
Size range and sheath colors1 to 37 pairs/triples/cores (0.5, 0.75, 1.0, 1.5, 2.5 mm²); grey standard, blue (Ex-i) or orange (-FFR) SHF1 sheath
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

FM2XH, FM2XCH & FM2XAAH (-FFR) 150/250 V Dimension Schedule

FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Signal Schedule
Model & Size (mm²)LayoutShielding & Fire TierNominal OD (mm)Approx. Weight (kg/km)Sheath ColorOrder MOQNext step
FM2XH 7×0.757C × 0.75Unscreened Multi-Core10.2135Grey SHF150 mRequest this size
FM2XCH 2×2×0.752P × 0.75Overall Cu Braid11.4170Grey SHF150 mRequest this size
FM2XCH 7×2×0.757P × 0.75Overall Cu Braid15.8345Grey SHF150 mRequest this size
FM2XCCH 4×2×0.754P × 0.75Ind. + Overall Cu Braid15.6340Grey SHF150 mRequest this size
FM2XAH 4×2×0.754P × 0.75Overall Al-PES Foil12.2175Grey / Blue SHF150 mRequest this size
FM2XAAH 4×2×0.754P × 0.75Ind. + Overall Al Foil13.4205Grey / Blue SHF150 mRequest this size
FM2XAAH 12×2×0.7512P × 0.75Ind. + Overall Al Foil20.8485Grey / Blue SHF150 mRequest this size
FM2XAAH 7×2×1.57P × 1.5Ind. + Overall Al Foil19.8490Grey / Blue SHF150 mRequest this size
FM2XCH-FFR 2×2×0.752P × 0.75Mica + Overall Cu Braid13.2220Orange SHF150 mRequest this size
FM2XAAH-FFR 2×2×0.752P × 0.75Mica + Ind./Coll. Foil13.8225Orange SHF150 mRequest this size
FM2XAAH-FFR 4×2×1.54P × 1.5Mica + Ind./Coll. Foil19.2445Orange SHF150 mRequest this size
FM2XAAH-FFR 12×2×0.7512P × 0.75Mica + Ind./Coll. Foil24.6640Orange SHF150 mRequest this size

Single-pair, 2-pair, 4-pair, 7-pair, 10-pair, 12-pair, 19-pair, 24-pair and 37-pair counts as well as twisted triples (3×) and multi-core builds are manufactured across 0.5 mm² to 2.5 mm². Blue SHF1 outer jackets are supplied on request for intrinsically safe Ex-i separation.

ASCII part references for BOM and ERP entry: FM2XH-7x0.75, FM2XCH-2x2x0.75, FM2XCH-7x2x0.75, FM2XCCH-4x2x0.75, FM2XAH-4x2x0.75, FM2XAAH-4x2x0.75, FM2XAAH-12x2x0.75, FM2XAAH-7x2x1.5, FM2XCH-FFR-2x2x0.75, FM2XAAH-FFR-2x2x0.75, FM2XAAH-FFR-4x2x1.5, FM2XAAH-FFR-12x2x0.75.

Standards

FM2X IEC 60092-376 & IEC 60331 Marine Signal Standards

FM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable standards and test references
Standard or specificationApplication
IEC 60092-376Design reference for 150/250 V (300 V) shipboard cables for control and instrumentation circuits.
IEC 60331-1 / -2 / -21 (-FFR Series)Circuit integrity under fire design reference for emergency shipboard communication and alarm cabling.
IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2Bunched vertical flame retardance, zero-halogen corrosivity and low smoke density reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and routine quality documentation

IEC 60092-376 — Electrical Installations in Ships: Cables for Control and Instrumentation Circuits 150/250 V

IEC 60332-3-22 — Bunched Cable Vertical Flame Spread Test (Category A)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.