Marine & Offshore Cables TEBAOFLEX

M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331)

M2XH-FFR (unscreened) and M2XCH-FFR (90% copper-wire braided EMC screen) are 0.6/1 kV fire-resistant halogen-free shipboard power cables in FI and NOFI builds. Each stranded Class 2 or Class 5 copper conductor is wrapped with overlapping phlogopite mica glass fire-barrier tape beneath 90 °C XLPE insulation and an orange or black SHF1 sheath—designed to maintain essential emergency power under IEC 60331 fire exposure.

Product information
SKU
TF-M2X-FFR-1KV
Brand
TEBAOFLEX
Product overview

M2XH-FFR and M2XCH-FFR (in FI and NOFI constructions) are 0.6/1 kV mica-barrier fire-resistant, halogen-free shipboard power and control cables engineered to IEC 60092-353 and IEC 60331 for SOLAS-critical marine emergency systems that must stay energized during a compartment fire.

While standard M2XH/M2XCH cables are flame-retardant (stopping fire spread along a tray), they do not maintain live circuit continuity once flames reach the conductors. M2XH-FFR and M2XCH-FFR add precision-lapped mica glass fire-barrier tapes over every IEC 60228 Class 2 or flexible Class 5 copper conductor before extruding 90 °C XLPE insulation and a low-smoke zero-halogen SHF1 outer jacket (typically high-visibility orange for emergency identification or black on request). During fire, the XLPE chars cleanly while the ceramic mica barrier maintains electrical separation between phases and earth.

Specify M2XH-FFR for emergency escape lighting, watertight doors, PA/GA evacuation and lifeboat davits; specify copper-braided M2XCH-FFR where emergency fire pumps, bow thrusters or steering-gear controls also require 90% EMC braid screening. Where offshore drilling-mud resistance (SHF2) is also mandatory, step up to NEK 606 BFOU. Minimum order 50 m; lead time 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

M2XH-FFR & M2XCH-FFR Mica-Barrier Shipboard Construction

Dual-barrier fire-survival shipboard design layering phlogopite mica glass tape directly under 90 °C XLPE insulation, FI/NOFI halogen-free bedding, optional 90% copper braid and SHF1 jacket.

Clean 2D technical cross-section of 3-core M2XCH-FFR fire-resistant marine cable showing orange SHF1 sheath, copper wire braid, white halogen-free bedding, three XLPE cores and golden mica tape rings around copper strands
3-core M2XCH-FFR cross-section: copper conductors wrapped in ceramic mica tape beneath XLPE insulation, halogen-free bedding, copper braid and orange SHF1 jacket.
M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331) construction
ComponentMaterial and construction
1. Stranded Electrolytic Copper Conductor (Class 2 or Class 5)Annealed bare copper (tinned on request) per IEC 60228 from 1.0 mm² to 300 mm² for fixed and tight-bend emergency routing.
2. Overlapping Phlogopite Mica Glass Fire-Barrier TapeHigh-temperature ceramic mica barrier applied directly over each conductor to preserve dielectric integrity during IEC 60331 direct flame tests.
3. 90 °C XLPE Insulation & FI/NOFI Halogen-Free BeddingCross-linked polyethylene insulation rated 0.6/1 kV over mica tape, bundled under extruded halogen-free bedding (FI) or separator tape (NOFI).
4. Optional 90% Copper Wire Braid Screen (M2XCH-FFR)Electrolytic bare copper wire braid (minimum 90% optical coverage) minimizing electromagnetic interference on emergency drive and control circuits.
5. Orange or Black SHF1 Halogen-Free Outer SheathFlame-retardant, low-smoke, zero-halogen SHF1 polyolefin jacket (IEC 60332-3-22 Cat. A, IEC 60754-1/-2, IEC 61034-1/-2) rated -40 °C to +90 °C.

M2XH-FFR & M2XCH-FFR Fire-Survival Designation Breakdown

  • M2X: Marine shipboard cable (M) with 90 °C cross-linked polyethylene (2X) insulation
  • C / (blank): C = 90% bare copper wire braid EMC screen; blank = unscreened M2XH-FFR
  • H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath
  • -FFR: Fire-resistant construction incorporating overlapping phlogopite mica glass tape per IEC 60331
  • FI / NOFI: Extruded halogen-free inner bedding (FI) or compact tape separator (NOFI)
Applications

M2XH-FFR & M2XCH-FFR Fire-Pump, Emergency Power & Safety Applications

Dedicated to SOLAS essential emergency power and life-safety circuits on passenger ships, tankers, LNG carriers, workboats and naval auxiliaries.

Modern vessel emergency generator and fire-pump bulkhead showing orange M2XCH-FFR fire-resistant marine cables routed cleanly through stainless bulkhead transits
Marine emergency switchgear and bulkhead transit installation powered by orange fire-resistant M2XCH-FFR circuits.
  • Emergency fire-fighting pumps, sprinkler compressors, bilge pumps and engine-room CO2/water-mist release feeders.
  • Emergency generator busbar links, steering-gear power supply, watertight bulkhead door actuators and thruster emergency backup.
  • Escape-route lighting, muster-station illumination, general alarm horns and emergency navigation power panels.
  • Enclosed passenger-vessel and ferry stairwells requiring zero-halogen, low-smoke toxicity control alongside circuit survival.

M2XH-FFR / M2XCH-FFR vs Standard M2XH vs NEK 606 BFOU

M2XH-FFR / M2XCH-FFR vs Standard M2XH / M2XCH vs Offshore NEK 606 BFOU
Cable SeriesFire IntegrityOuter SheathBest Vessel / Offshore Use
M2XH-FFR / M2XCH-FFR (this page)Mica tape (IEC 60331)SHF1 LSZH (Orange / Black)Merchant ship fire pumps, emergency lighting & steering gear
M2XH / M2XCH / M2XSHFlame-retardant onlySHF1 LSZH (Black)General non-emergency 0.6/1 kV shipboard power distribution
FM2XCH-FFR / FM2XAAH-FFRMica tape (IEC 60331)SHF1 LSZH (Orange / Grey)150/250 V emergency fire alarm, PA/GA & radar signal loops
NEK 606 BFOU / BFCUMica tape (IEC 60331)SHF2 Mud-ResistantOffshore drilling platforms & FPSO hydrocarbon hazard zones

Always match fire-resistant cables with fire-rated multi-cable transits (MCTs) and ceramic terminal blocks at bulkhead crossings.

M2XH-FFR & M2XCH-FFR Fire-Resistant Cable RFQ Checklist

  • Designation: M2XH-FFR (unscreened) or M2XCH-FFR (90% copper braid EMC screen), plus FI extruded bedding or NOFI tape wrap.
  • Outer sheath color preference (orange for rapid emergency-circuit tracing or black) and conductor class (Class 2 or Class 5).
  • Core count and cross-section (1.0–300 mm²) plus required IEC 60331 test profile (750 °C 90 min or 830 °C mechanical shock).
  • Order length per size (MOQ 50 m) and any third-party witnessed inspection requirements (lead time 7 to 45 working days).

Related selection resources

M2XH-FFR & M2XCH-FFR Fire-Resistant Marine Cable FAQ

What does the FFR suffix mean on M2XH-FFR and M2XCH-FFR marine cables?

FFR stands for Fire-Resistant (Feuerwiderstandsfähig / Flame & Fire Resistant), indicating a phlogopite mica glass tape fire barrier wrapped directly around each copper conductor so the circuit continues carrying rated 0.6/1 kV voltage during a shipboard fire per IEC 60331.

Why are M2XH-FFR and M2XCH-FFR commonly supplied with an orange outer sheath?

An orange SHF1 jacket lets shipyard electricians, surveyors and crew distinguish safety-critical fire-survival circuits (fire pumps, emergency generators, escape lighting) instantly from standard black power trays during installation and maintenance.

Can M2XCH-FFR be installed through watertight bulkhead cable transits?

Yes. Specifying the FI (extruded halogen-free inner bedding) variant ensures a tightly round profile beneath the braid and sheath for consistent gas- and water-tight compression inside marine MCT bulkhead frames.

What is the difference between M2XCH-FFR and MGCH-FFR?

M2XCH-FFR uses XLPE insulation (2X) per modern IEC 60092-353 compact profiles, whereas MGCH-FFR uses HEPR/EPR rubber insulation (G) per traditional DIN 89158 specifications; both use mica tape and SHF1 halogen-free sheathing for 0.6/1 kV fire-survival service.

What is the MOQ and production lead time for M2XH-FFR and M2XCH-FFR?

50 m minimum order per size, custom-manufactured in 7 to 45 working days with full factory routine dielectric and dimensional records.

Specifications

M2XH-FFR & M2XCH-FFR Dimension & Weight Schedule

M2XH-FFR / M2XCH-FFR Electrical & Fire-Integrity Ratings

  • Mica-tape fire-barrier circuit integrity: Overlapping phlogopite mica glass tape directly over every copper conductor sustains voltage under IEC 60331 flame exposure
  • Unscreened (M2XH-FFR) & EMC braided (M2XCH-FFR): Choose lightweight M2XH-FFR for safety lighting or 90% copper-braided M2XCH-FFR for fire-pump VFD and steering circuits
  • IEC 60092-353 0.6/1 (1.2) kV rating: 3.5 kV AC test voltage, -40 °C to +90 °C fixed service, 250 °C short-circuit rating with zero-halogen SHF1 sheath
  • FI and NOFI flexible Class 5 builds: Extruded halogen-free inner bedding (FI) for firestop bulkhead transit sealing or slim NOFI tape-wrapped trays
  • 50 m MOQ in orange or black SHF1: 1 to 37 cores across 1.0 mm² to 300 mm², custom-built to order in 7 to 45 working days
M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331) technical data
ParameterValue
Rated voltage0.6/1 kV AC (1.2 kV Um), 3.5 kV AC routine test voltage per IEC 60092-353
Fire resistance design referencePhlogopite mica glass barrier designed to IEC 60331-1/-2/-21 circuit integrity during fire
Operating temperature range-40 °C to +90 °C fixed service (-15 °C minimum installation temperature; 250 °C short-circuit)
Minimum bending radius4 × D for M2XH-FFR up to 25 mm OD (6 × D above 25 mm OD); 6 × D for braided M2XCH-FFR
Conductor and outer sheathClass 2 or Class 5 copper (1.0–300 mm², 1–37 cores) with orange or black SHF1 halogen-free outer sheath
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

M2XH-FFR & M2XCH-FFR 0.6/1 kV Dimension & Weight Schedule

TF-M2X-FFR (M2XH-FFR & M2XCH-FFR) 0.6/1 kV Fire-Resistant Shipboard Cable Representative Sizes
Designation & BuildCores × Size (mm²)Fire Barrier & ScreenNominal OD (mm)Approx. Weight (kg/km)Min. Bend RadiusOrder MOQNext step
M2XH-FFR (FI) 2×1.52 × 1.5Mica + Unscreened10.81504 × D50 mRequest this size
M2XH-FFR (FI) 3×2.53 × 2.5Mica + Unscreened12.42154 × D50 mRequest this size
M2XH-FFR (FI) 4×64 × 6Mica + Unscreened16.84454 × D50 mRequest this size
M2XH-FFR (FI) 3×253 × 25Mica + Unscreened24.21,0904 × D50 mRequest this size
M2XH-FFR (FI) 3×703 × 70Mica + Unscreened35.62,6206 × D50 mRequest this size
M2XCH-FFR (FI) 2×1.52 × 1.5Mica + 90% Cu Braid11.82056 × D50 mRequest this size
M2XCH-FFR (FI) 3×2.53 × 2.5Mica + 90% Cu Braid13.42856 × D50 mRequest this size
M2XCH-FFR (FI) 4×104 × 10Mica + 90% Cu Braid20.47956 × D50 mRequest this size
M2XCH-FFR (FI) 3×353 × 35Mica + 90% Cu Braid28.41,7406 × D50 mRequest this size
M2XCH-FFR (FI) 3×953 × 95Mica + 90% Cu Braid42.64,1206 × D50 mRequest this size
M2XCH-FFR (FI) 7×1.57 × 1.5Mica + 90% Cu Braid16.64306 × D50 mRequest this size
M2XCH-FFR (FI) 1×1501 × 150Mica + 90% Cu Braid24.51,7106 × D50 mRequest this size

Mica-tape barrier adds approximately 0.8 to 2.0 mm over standard M2XH/M2XCH outer diameters; confirm exact OD against MCT bulkhead transit modules before ordering. Both orange (emergency circuit standard) and black SHF1 sheaths are available.

ASCII part references for BOM and ERP entry: M2XH-FFR-2x1.5, M2XH-FFR-3x2.5, M2XH-FFR-4x6, M2XH-FFR-3x25, M2XH-FFR-3x70, M2XCH-FFR-2x1.5, M2XCH-FFR-3x2.5, M2XCH-FFR-4x10, M2XCH-FFR-3x35, M2XCH-FFR-3x95, M2XCH-FFR-7x1.5, M2XCH-FFR-1x150.

Standards

M2XH-FFR & M2XCH-FFR IEC 60331 & IEC 60092-353 Standards

M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331) standards and test references
Standard or specificationApplication
IEC 60331-1 / -2 / -21Circuit integrity under direct flame (750 °C / 830 °C options) design reference for emergency shipboard circuits.
IEC 60092-353 & IEC 60092-3600.6/1 kV XLPE-insulated, SHF1 halogen-free sheathed shipboard power cable construction reference.
IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2Bunched flame retardance, acid-gas zero-halogen safety and low smoke density reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and routine quality documentation

IEC 60092-353 — Electrical Installations in Ships: 1 kV and 3 kV Power Cables

IEC 60332-3-22 — Bunched Cable Vertical Flame Propagation Test (Category A)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.