M2XH-FFR & M2XCH-FFR 0.6/1 kV Fire-Resistant Marine Power Cable (IEC 60331)
M2XH-FFR (unscreened) and M2XCH-FFR (90% copper-wire braided EMC screen) are 0.6/1 kV fire-resistant halogen-free shipboard power cables in FI and NOFI builds. Each stranded Class 2 or Class 5 copper conductor is wrapped with overlapping phlogopite mica glass fire-barrier tape beneath 90 °C XLPE insulation and an orange or black SHF1 sheath—designed to maintain essential emergency power under IEC 60331 fire exposure.
M2XH-FFR and M2XCH-FFR (in FI and NOFI constructions) are 0.6/1 kV mica-barrier fire-resistant, halogen-free shipboard power and control cables engineered to IEC 60092-353 and IEC 60331 for SOLAS-critical marine emergency systems that must stay energized during a compartment fire.
While standard M2XH/M2XCH cables are flame-retardant (stopping fire spread along a tray), they do not maintain live circuit continuity once flames reach the conductors. M2XH-FFR and M2XCH-FFR add precision-lapped mica glass fire-barrier tapes over every IEC 60228 Class 2 or flexible Class 5 copper conductor before extruding 90 °C XLPE insulation and a low-smoke zero-halogen SHF1 outer jacket (typically high-visibility orange for emergency identification or black on request). During fire, the XLPE chars cleanly while the ceramic mica barrier maintains electrical separation between phases and earth.
Specify M2XH-FFR for emergency escape lighting, watertight doors, PA/GA evacuation and lifeboat davits; specify copper-braided M2XCH-FFR where emergency fire pumps, bow thrusters or steering-gear controls also require 90% EMC braid screening. Where offshore drilling-mud resistance (SHF2) is also mandatory, step up to NEK 606 BFOU. Minimum order 50 m; lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
M2XH-FFR & M2XCH-FFR Mica-Barrier Shipboard Construction
Dual-barrier fire-survival shipboard design layering phlogopite mica glass tape directly under 90 °C XLPE insulation, FI/NOFI halogen-free bedding, optional 90% copper braid and SHF1 jacket.

| Component | Material and construction |
|---|---|
| 1. Stranded Electrolytic Copper Conductor (Class 2 or Class 5) | Annealed bare copper (tinned on request) per IEC 60228 from 1.0 mm² to 300 mm² for fixed and tight-bend emergency routing. |
| 2. Overlapping Phlogopite Mica Glass Fire-Barrier Tape | High-temperature ceramic mica barrier applied directly over each conductor to preserve dielectric integrity during IEC 60331 direct flame tests. |
| 3. 90 °C XLPE Insulation & FI/NOFI Halogen-Free Bedding | Cross-linked polyethylene insulation rated 0.6/1 kV over mica tape, bundled under extruded halogen-free bedding (FI) or separator tape (NOFI). |
| 4. Optional 90% Copper Wire Braid Screen (M2XCH-FFR) | Electrolytic bare copper wire braid (minimum 90% optical coverage) minimizing electromagnetic interference on emergency drive and control circuits. |
| 5. Orange or Black SHF1 Halogen-Free Outer Sheath | Flame-retardant, low-smoke, zero-halogen SHF1 polyolefin jacket (IEC 60332-3-22 Cat. A, IEC 60754-1/-2, IEC 61034-1/-2) rated -40 °C to +90 °C. |
M2XH-FFR & M2XCH-FFR Fire-Survival Designation Breakdown
- M2X: Marine shipboard cable (M) with 90 °C cross-linked polyethylene (2X) insulation
- C / (blank): C = 90% bare copper wire braid EMC screen; blank = unscreened M2XH-FFR
- H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath
- -FFR: Fire-resistant construction incorporating overlapping phlogopite mica glass tape per IEC 60331
- FI / NOFI: Extruded halogen-free inner bedding (FI) or compact tape separator (NOFI)
M2XH-FFR & M2XCH-FFR Fire-Pump, Emergency Power & Safety Applications
Dedicated to SOLAS essential emergency power and life-safety circuits on passenger ships, tankers, LNG carriers, workboats and naval auxiliaries.

- Emergency fire-fighting pumps, sprinkler compressors, bilge pumps and engine-room CO2/water-mist release feeders.
- Emergency generator busbar links, steering-gear power supply, watertight bulkhead door actuators and thruster emergency backup.
- Escape-route lighting, muster-station illumination, general alarm horns and emergency navigation power panels.
- Enclosed passenger-vessel and ferry stairwells requiring zero-halogen, low-smoke toxicity control alongside circuit survival.
M2XH-FFR / M2XCH-FFR vs Standard M2XH vs NEK 606 BFOU
| Cable Series | Fire Integrity | Outer Sheath | Best Vessel / Offshore Use |
|---|---|---|---|
| M2XH-FFR / M2XCH-FFR (this page) | Mica tape (IEC 60331) | SHF1 LSZH (Orange / Black) | Merchant ship fire pumps, emergency lighting & steering gear |
| M2XH / M2XCH / M2XSH | Flame-retardant only | SHF1 LSZH (Black) | General non-emergency 0.6/1 kV shipboard power distribution |
| FM2XCH-FFR / FM2XAAH-FFR | Mica tape (IEC 60331) | SHF1 LSZH (Orange / Grey) | 150/250 V emergency fire alarm, PA/GA & radar signal loops |
| NEK 606 BFOU / BFCU | Mica tape (IEC 60331) | SHF2 Mud-Resistant | Offshore drilling platforms & FPSO hydrocarbon hazard zones |
Always match fire-resistant cables with fire-rated multi-cable transits (MCTs) and ceramic terminal blocks at bulkhead crossings.
M2XH-FFR & M2XCH-FFR Fire-Resistant Cable RFQ Checklist
- Designation: M2XH-FFR (unscreened) or M2XCH-FFR (90% copper braid EMC screen), plus FI extruded bedding or NOFI tape wrap.
- Outer sheath color preference (orange for rapid emergency-circuit tracing or black) and conductor class (Class 2 or Class 5).
- Core count and cross-section (1.0–300 mm²) plus required IEC 60331 test profile (750 °C 90 min or 830 °C mechanical shock).
- Order length per size (MOQ 50 m) and any third-party witnessed inspection requirements (lead time 7 to 45 working days).
Related selection resources
- Compare Standard M2XH / M2XCH / M2XSH Halogen-Free Shipboard Cables
- Pair with FM2XCH-FFR & FM2XAAH-FFR Fire-Resistant Signal Cables
- Explore General IEC 60331 Fire-Resistant Shipboard Power Series
- Upgrade to NEK 606 BFOU Mud-Resistant Fire-Survival Offshore Cables
- Browse Complete Marine & Offshore Shipboard Cable Catalog
- Explore Shipboard & Offshore Marine Cable Solutions Hub
M2XH-FFR & M2XCH-FFR Fire-Resistant Marine Cable FAQ
What does the FFR suffix mean on M2XH-FFR and M2XCH-FFR marine cables?
FFR stands for Fire-Resistant (Feuerwiderstandsfähig / Flame & Fire Resistant), indicating a phlogopite mica glass tape fire barrier wrapped directly around each copper conductor so the circuit continues carrying rated 0.6/1 kV voltage during a shipboard fire per IEC 60331.
Why are M2XH-FFR and M2XCH-FFR commonly supplied with an orange outer sheath?
An orange SHF1 jacket lets shipyard electricians, surveyors and crew distinguish safety-critical fire-survival circuits (fire pumps, emergency generators, escape lighting) instantly from standard black power trays during installation and maintenance.
Can M2XCH-FFR be installed through watertight bulkhead cable transits?
Yes. Specifying the FI (extruded halogen-free inner bedding) variant ensures a tightly round profile beneath the braid and sheath for consistent gas- and water-tight compression inside marine MCT bulkhead frames.
What is the difference between M2XCH-FFR and MGCH-FFR?
M2XCH-FFR uses XLPE insulation (2X) per modern IEC 60092-353 compact profiles, whereas MGCH-FFR uses HEPR/EPR rubber insulation (G) per traditional DIN 89158 specifications; both use mica tape and SHF1 halogen-free sheathing for 0.6/1 kV fire-survival service.
What is the MOQ and production lead time for M2XH-FFR and M2XCH-FFR?
50 m minimum order per size, custom-manufactured in 7 to 45 working days with full factory routine dielectric and dimensional records.
M2XH-FFR & M2XCH-FFR Dimension & Weight Schedule
M2XH-FFR / M2XCH-FFR Electrical & Fire-Integrity Ratings
- Mica-tape fire-barrier circuit integrity: Overlapping phlogopite mica glass tape directly over every copper conductor sustains voltage under IEC 60331 flame exposure
- Unscreened (M2XH-FFR) & EMC braided (M2XCH-FFR): Choose lightweight M2XH-FFR for safety lighting or 90% copper-braided M2XCH-FFR for fire-pump VFD and steering circuits
- IEC 60092-353 0.6/1 (1.2) kV rating: 3.5 kV AC test voltage, -40 °C to +90 °C fixed service, 250 °C short-circuit rating with zero-halogen SHF1 sheath
- FI and NOFI flexible Class 5 builds: Extruded halogen-free inner bedding (FI) for firestop bulkhead transit sealing or slim NOFI tape-wrapped trays
- 50 m MOQ in orange or black SHF1: 1 to 37 cores across 1.0 mm² to 300 mm², custom-built to order in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (1.2 kV Um), 3.5 kV AC routine test voltage per IEC 60092-353 |
| Fire resistance design reference | Phlogopite mica glass barrier designed to IEC 60331-1/-2/-21 circuit integrity during fire |
| Operating temperature range | -40 °C to +90 °C fixed service (-15 °C minimum installation temperature; 250 °C short-circuit) |
| Minimum bending radius | 4 × D for M2XH-FFR up to 25 mm OD (6 × D above 25 mm OD); 6 × D for braided M2XCH-FFR |
| Conductor and outer sheath | Class 2 or Class 5 copper (1.0–300 mm², 1–37 cores) with orange or black SHF1 halogen-free outer sheath |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
M2XH-FFR & M2XCH-FFR 0.6/1 kV Dimension & Weight Schedule
| Designation & Build | Cores × Size (mm²) | Fire Barrier & Screen | Nominal OD (mm) | Approx. Weight (kg/km) | Min. Bend Radius | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| M2XH-FFR (FI) 2×1.5 | 2 × 1.5 | Mica + Unscreened | 10.8 | 150 | 4 × D | 50 m | Request this size |
| M2XH-FFR (FI) 3×2.5 | 3 × 2.5 | Mica + Unscreened | 12.4 | 215 | 4 × D | 50 m | Request this size |
| M2XH-FFR (FI) 4×6 | 4 × 6 | Mica + Unscreened | 16.8 | 445 | 4 × D | 50 m | Request this size |
| M2XH-FFR (FI) 3×25 | 3 × 25 | Mica + Unscreened | 24.2 | 1,090 | 4 × D | 50 m | Request this size |
| M2XH-FFR (FI) 3×70 | 3 × 70 | Mica + Unscreened | 35.6 | 2,620 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 2×1.5 | 2 × 1.5 | Mica + 90% Cu Braid | 11.8 | 205 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 3×2.5 | 3 × 2.5 | Mica + 90% Cu Braid | 13.4 | 285 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 4×10 | 4 × 10 | Mica + 90% Cu Braid | 20.4 | 795 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 3×35 | 3 × 35 | Mica + 90% Cu Braid | 28.4 | 1,740 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 3×95 | 3 × 95 | Mica + 90% Cu Braid | 42.6 | 4,120 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 7×1.5 | 7 × 1.5 | Mica + 90% Cu Braid | 16.6 | 430 | 6 × D | 50 m | Request this size |
| M2XCH-FFR (FI) 1×150 | 1 × 150 | Mica + 90% Cu Braid | 24.5 | 1,710 | 6 × D | 50 m | Request this size |
Mica-tape barrier adds approximately 0.8 to 2.0 mm over standard M2XH/M2XCH outer diameters; confirm exact OD against MCT bulkhead transit modules before ordering. Both orange (emergency circuit standard) and black SHF1 sheaths are available.
ASCII part references for BOM and ERP entry: M2XH-FFR-2x1.5, M2XH-FFR-3x2.5, M2XH-FFR-4x6, M2XH-FFR-3x25, M2XH-FFR-3x70, M2XCH-FFR-2x1.5, M2XCH-FFR-3x2.5, M2XCH-FFR-4x10, M2XCH-FFR-3x35, M2XCH-FFR-3x95, M2XCH-FFR-7x1.5, M2XCH-FFR-1x150.
M2XH-FFR & M2XCH-FFR IEC 60331 & IEC 60092-353 Standards
| Standard or specification | Application |
|---|---|
| IEC 60331-1 / -2 / -21 | Circuit integrity under direct flame (750 °C / 830 °C options) design reference for emergency shipboard circuits. |
| IEC 60092-353 & IEC 60092-360 | 0.6/1 kV XLPE-insulated, SHF1 halogen-free sheathed shipboard power cable construction reference. |
| IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2 | Bunched flame retardance, acid-gas zero-halogen safety and low smoke density reference. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing and routine quality documentation
IEC 60092-353 — Electrical Installations in Ships: 1 kV and 3 kV Power Cables
IEC 60332-3-22 — Bunched Cable Vertical Flame Propagation Test (Category A)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
M2XH, M2XCH & M2XSH 0.6/1 kV Halogen-Free Shipboard Power Cable (IEC 60092-353)
A related cable option for a different application or duty profile.
View productFM2XH, FM2XCH, FM2XCCH, FM2XAH & FM2XAAH (-FFR) 150/250 V Marine Communication & Control Cable
A related cable option for a different application or duty profile.
View productMGCG, FMGCG, MGG & MGCH (-FFR) DIN 89158 / 89159 / 89160 Marine Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.