H05SJ-K & SiF/GL Fiberglass-Braided Silicone Wire (300/500 V, 180 °C)
H05SJ-K and SiF/GL fiberglass-braided silicone single-core wires (300/500 V, 2,000 V AC test) pair IEC 60228 Class 5 tinned copper conductors (0.5 to 150 mm²) with cross-linked EI2 silicone rubber insulation (-60 °C to +180 °C continuous, +200 °C peak) and a silicone-impregnated glass-fibre outer braid per EN 50525-2-83, HD 22.3 and DIN VDE 0250.
H05SJ-K and SiF/GL fiberglass-braided silicone single-core wires deliver mechanically protected 300/500 V (up to 450/750 V on heavy VDE feeder sections >= 1.5 mm² in dry switchgear) internal and equipment wiring across -60 °C to +180 °C ambient zones, spanning 2.3 mm to 23.4 mm nominal outer diameter and 15 kg/km to 1,734 kg/km cable weight from 0.5 mm² up to 150 mm².
Standard unbraided silicone hook-up wires tear or notch easily when pulled through punched sheet-metal knockouts, luminaire stems, ceramic heater blocks or cast-iron furnace terminal boxes. By locking a high-density glass-silk outer braid impregnated with high-temperature silicone resin directly over cross-linked EI2 silicone rubber and IEC 60228 Class 5 tinned copper strands, H05SJ-K and SiF/GL resist cut-through, thermal-cycling chafe and glass/foundry radiant heat while remaining halogen-free per IEC 60754-1 and IEC 60754-2.
Specify H05SJ-K (0.75 to 6 mm² European harmonized code) or SiF/GL (0.5 to 150 mm² VDE code, plus Class 1 solid SiD/GL) whenever single-core 180 °C leads require mechanical braid protection; select unbraided SiF or SiFF Class 6 where ultra-tight 5x to 7.5x OD cabinet routing in clean enclosures is needed, or upgrade to MGT mica-glass wire above +200 °C up to +450/+538 °C (300/500 m spools on fine sizes, MOQ 50 m on >= 4 mm², 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
H05SJ-K & SiF/GL Fiberglass-Braided Silicone Wire Construction
Each TEBAOFLEX H05SJ-K, SiF/GL and SiD/GL single-core lead wire combines anti-oxidizing tinned copper conductors, ozone- and oil-resistant EI2 silicone elastomer and fray-resistant silicone-varnished glass-fibre braiding.

| Component | Material and construction |
|---|---|
| 1. Tinned Copper Conductor (Class 5 or Class 1) | Fine-stranded annealed tinned copper per IEC 60228 / DIN EN 60228 Class 5 on H05SJ-K and SiF/GL (0.5 to 150 mm²) to prevent copper oxidation at +180 °C; solid tinned copper Class 1 on SiD/GL (0.5 to 6 mm²); plain bare copper SIAF/GL available to order. |
| 2. Cross-Linked Silicone Rubber Core Insulation (EI2) | Halogen-free heat-vulcanized silicone elastomer compound Type EI2 (EN 50363-1 / DIN VDE 0250), rated -60 °C to +180 °C continuous (+200 °C short-time) with >= 20 MOhm*km (up to 2,000 MOhm*km at 20 °C) insulation resistance. |
| 3. Colour-Coded Core Identification | Natural white outer braid as standard, or pigmented tracer/dyed silicone-varnish finishes in black, blue, brown, red, red-brown, violet and green-yellow protective earth. |
| 4. Silicone-Impregnated Fiberglass Outer Braid (J / GL) | Closely woven alkali-free E-glass / glass-silk outer braid saturated with transparent or colour-matched high-temperature silicone varnish so cut ends strip cleanly for crimping without glass-fibre fraying. |
H05SJ-K, SiF/GL & SiD/GL Type Designation Breakdown
- H05: CENELEC harmonized cable code for 300/500 V AC rated voltage (Uo/U)
- S (in H05SJ-K) / Si (in SiF/GL): Heat-resistant cross-linked silicone rubber core insulation Type EI2 (-60 °C to +180 °C)
- J / GL: Silicone-varnish-impregnated woven glass-fibre / glass-silk outer mechanical protective braid
- -K / F: Flexible fine-stranded conductor per IEC 60228 Class 5 for fixed equipment and panel installation
- SiD/GL: Solid tinned copper conductor variant per IEC 60228 Class 1 (0.5 to 6 mm²) with glass-silk braid
H05SJ-K & SiF/GL Furnace, Switchgear & Luminaire Applications
Deploy H05SJ-K, SiF/GL and SiD/GL braided single-core silicone wires in dry thermal-process machinery, switchgear cubicles, commercial ovens and industrial luminaire assemblies.

- Heat-treatment furnaces, foundry drying ovens, glass annealing lehrs, ceramic kilns and plastics extruder barrel heater-band terminal wiring.
- Low-voltage switchgear, resistor load banks, transformer terminal boxes and motor/generator lead connections exposed to elevated busbar temperatures.
- High-wattage industrial floodlights, infrared curing lamps, commercial bakery equipment and sauna/HVAC heating elements requiring fray-free braided leads.
- Form-holding internal panel jumpers (using Class 1 solid SiD/GL 0.5 to 6 mm²) and high-current 10 to 150 mm² single-core furnace power risers (SiF/GL).
H05SJ-K / SiF/GL vs SIAF/GL vs Braidless SiF vs MGT 450 °C Wire
| Wire Designation | Voltage & Temp Rating | Conductor & Outer Layer | When to Specify |
|---|---|---|---|
| H05SJ-K & SiF/GL (this page) | 300/500 V, -60 to +180 °C (+200 °C peak) | Class 5 tinned Cu + EI2 silicone + varnished fiberglass braid | Harmonized European OEM panels, ovens & 0.5–150 mm² braided feeders |
| SIAF/GL Silicone Wire | 300/500 V, -60 to +180 °C | Plain or tinned Class 5 Cu + thinner non-HAR silicone + glass braid | Compact luminaire & appliance harnesses needing slimmer non-HAR OD |
| SiF & SiFF Class 6 Braidless Silicone | 300/500 V, -60 to +180 °C | Class 5 (SiF) or Class 6 (SiFF) tinned Cu + smooth silicone only | Cleanroom/appliance wiring where glass fibres are prohibited & 5x–7.5x OD bends |
| MGT / UL 5359 Mica-Glass Lead Wire | 300/600 V, up to +450 °C / +538 °C | Nickel-plated Cu (2%/27% Ni) + mica tapes + treated fiberglass braid | Heater bands, kiln burners & molten-metal zones exceeding +200 °C |
Choose H05SJ-K / SiF/GL whenever metal panel pass-throughs or heater terminal vibration would cut unbraided silicone insulation at up to +180 °C.
H05SJ-K & SiF/GL Braided Silicone Wire RFQ Ordering Checklist
- Target designation (H05SJ-K harmonized 0.75–6 mm², SiF/GL 0.5–150 mm² Class 5, or SiD/GL 0.5–6 mm² Class 1 solid).
- Conductor finish: standard annealed tinned copper (+180 °C), plain copper, or nickel-plated copper for terminal oxidation resistance.
- Nominal cross-section (mm²), braid colour / tracer code (natural white, red-brown, black, blue, brown or green-yellow).
- Installation environment: ventilated dry air temperature (-60 °C to +180 °C), conduit/gland ID and fixed bend radius.
- Order quantity per colour (300 m / 500 m standard spools on 0.5–2.5 mm²; MOQ 50 m reels on 4–150 mm²) and delivery schedule (7 to 45 working days).
Related selection resources
- High-temperature silicone, fluoropolymer and mica-glass wire catalog
- Custom high-temperature wire and furnace cable manufacturing solutions
- SIAF/GL 180 °C Slim-Wall Fiberglass-Braided Silicone Wire
- SiF 180 °C Braidless Flexible Silicone Single-Core Wire
- MGT 450 °C / 538 °C Mica-Glass Ultra-High-Temperature Lead Wire
- Engineering guide: High-temperature wire insulation ratings (Silicone vs PTFE vs Mica)
H05SJ-K & SiF/GL Braided Silicone Wire Frequently Asked Questions
What is the difference between H05SJ-K, SiF/GL and SIAF/GL fiberglass-braided silicone wires?
H05SJ-K is the CENELEC EN 50525-2-83 (HD 22.3) harmonized designation covering 0.75 mm² to 6 mm² at 300/500 V with slightly thicker regulated EI2 insulation, whereas SiF/GL is the DIN VDE 0250 tinned-copper designation extending down to 0.25–0.5 mm² and up to 150–240 mm²; SIAF/GL uses a slimmer non-harmonized wall and often plain copper unless tinned copper is specified.
Does the fiberglass braid on H05SJ-K and SiF/GL fray when stripped for terminal crimping?
No. TEBAOFLEX saturates the woven E-glass outer braid with heat-cured silicone varnish bonded lightly to the underlying EI2 silicone rubber, allowing mechanical or rotary wire strippers to make clean square cuts without glass-wool unravelling or loose airborne fibres.
Can H05SJ-K and SiF/GL wires operate continuously at +180 °C inside a sealed junction box?
H05SJ-K and SiF/GL are rated for +180 °C continuous conductor temperature (+200 °C short-circuit peak) in ventilated dry enclosures; if ambient temperature exceeds +100 °C inside a hermetically sealed, unventilated housing with trapped moisture, specify cabinet breathers or switch to our UL PFA / PTFE fluoropolymer hook-up wire.
Are H05SJ-K and SiF/GL single-core wires halogen-free and flame-retardant?
Yes. Both the EI2 cross-linked silicone core and the silicone-impregnated glass braid contain zero halogens per IEC 60754-1 and IEC 60754-2, pass IEC 60332-1-2 vertical flame testing, and leave a non-conductive SiO2 silica ash layer if exposed to direct fire.
What minimum order quantity applies to H05SJ-K and SiF/GL sizes from 0.5 mm² to 150 mm²?
Small hook-up cross-sections from 0.5 mm² to 2.5 mm² are supplied on 300 m or 500 m standard spools per colour, whereas power feeder cross-sections from 4 mm² to 150 mm² have a 50 m minimum order quantity with 7 to 45 working days manufacturing lead time.
H05SJ-K, SiF/GL & SiD/GL Dimensional & Weight Specifications
H05SJ-K & SiF/GL Key Electrical, Thermal & Put-Up Summary
- Harmonized & VDE cross-sections: 0.75 to 6 mm² harmonized H05SJ-K schedule (EN 50525-2-83 / HD 22.3) plus 0.5 mm² and 10 to 150 mm² VDE 0250 SiF/GL feeder extensions
- Abrasion-shielded EI2 silicone: Extruded halogen-free EI2 silicone insulation armoured by a tightly woven silicone-varnished glass-silk braid against sharp panel edges
- Wide thermal operating window: -60 °C to +180 °C continuous conductor temperature (+200 °C short-circuit rating) with SiO2 ceramic ash retention under flame exposure
- Flexible Class 5 & solid SiD/GL: Fine-stranded annealed tinned copper (IEC 60228 Class 5) as standard, plus Class 1 solid tinned copper SiD/GL (0.5 to 6 mm²) for form-holding bends
- Spool & feeder reel put-up: 300 m or 500 m factory spools on 0.5 to 2.5 mm² hook-up gauges and 50 m minimum order length on 4 to 150 mm² furnace feeder cross-sections (7 to 45 working days)
| Parameter | Value |
|---|---|
| Rated voltage | 300/500 V AC (Uo/U) per EN 50525-2-83 and VDE 0250 with 2000 V AC 50 Hz routine dielectric test (1500 V up to 1.0 mm2) |
| Conductor and cross-section range | IEC 60228 Class 5 tinned copper from 0.5 mm2 to 150 mm2 (H05SJ-K and SiF/GL) plus Class 1 solid tinned copper from 0.5 mm2 to 6 mm2 (SiD/GL) |
| Insulation and protective braid | Halogen-free cross-linked EI2 silicone rubber core insulation under a silicone-varnish-impregnated fiberglass braid |
| Operating temperature and bend radius | -60 C to +180 C continuous (+200 C short-time) with 10x to 15x OD minimum fixed bending radius and 15x OD occasional flexing radius |
| Standard put-up and lead time | 300 m or 500 m spools on 0.5 to 2.5 mm2 hook-up sizes and MOQ 50 m reels on 4 to 150 mm2 feeders in 7 to 45 working days |
| Halogen-free and flame behaviour | Halogen-free and non-corrosive combustion gases per IEC 60754-1 / IEC 60754-2; flame-retardant per IEC 60332-1-2 |
| Ventilation engineering note | Ensure natural air circulation when operating continuously above +100 C so silicone elastomer prevents sealed-enclosure steam reversion |
H05SJ-K & SiF/GL Class 5 Tinned Copper Dimensional & Weight Schedule
| Model & Cross-Section | Standard Scope | H05SJ-K Nom. OD (mm) | SiF/GL Nom. OD (mm) | Copper Index (kg/km) | Approx. Weight (kg/km) | Standard Put-Up / MOQ | Next step |
|---|---|---|---|---|---|---|---|
| H05SJ-K / SiF/GL 1x0.5 mm² | DIN VDE 0250 | 2.3 | 2.8 | 4.8 | 11 – 15 | 500 m spool | Request this size |
| H05SJ-K / SiF/GL 1x0.75 mm² | EN 50525-2-83 (HAR) | 2.6 – 2.9 | 2.9 | 7.2 | 14 – 19 | 500 m spool | Request this size |
| H05SJ-K / SiF/GL 1x1.0 mm² | EN 50525-2-83 (HAR) | 2.7 – 3.2 | 3.0 | 9.6 | 16 – 23 | 500 m spool | Request this size |
| H05SJ-K / SiF/GL 1x1.5 mm² | EN 50525-2-83 (HAR) | 3.0 – 3.5 | 3.2 | 14.4 | 22 – 30 | 500 m spool | Request this size |
| H05SJ-K / SiF/GL 1x2.5 mm² | EN 50525-2-83 (HAR) | 3.8 – 4.2 | 3.8 | 24.0 | 34 – 42 | 300 m spool | Request this size |
| H05SJ-K / SiF/GL 1x4 mm² | EN 50525-2-83 (HAR) | 4.6 – 4.7 | 4.6 | 38.0 | 53 – 55 | 100 m / MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x6 mm² | EN 50525-2-83 (HAR) | 5.3 – 5.6 | 5.4 | 58.0 | 76 – 90 | 100 m / MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x10 mm² | VDE 0250 Feeder | 7.2 | 7.6 | 96.0 | 131 – 145 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x16 mm² | VDE 0250 Feeder | 8.3 – 8.4 | 8.4 | 154.0 | 195 – 212 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x25 mm² | VDE 0250 Feeder | 10.2 – 10.4 | 10.2 | 240.0 | 294 – 320 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x35 mm² | VDE 0250 Feeder | 11.4 – 11.7 | 11.3 | 336.0 | 392 – 475 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x50 mm² | VDE 0250 Feeder | 13.8 – 14.0 | 13.4 | 480.0 | 551 – 605 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x70 mm² | VDE 0250 Feeder | 15.2 – 15.9 | 15.5 | 672.0 | 800 – 815 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x95 mm² | VDE 0250 Feeder | 18.6 – 18.7 | 18.5 | 912.0 | 1097 – 1110 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x120 mm² | VDE 0250 Feeder | 20.4 | 20.0 | 1152.0 | 1362 | MOQ 50 m | Request this size |
| H05SJ-K / SiF/GL 1x150 mm² | VDE 0250 Feeder | 23.4 | 21.2 | 1440.0 | 1715 – 1734 | MOQ 50 m | Request this size |
SiF/GL Companion Construction: SiD/GL Class 1 Solid Tinned Copper Schedule
| Designation & Size | Conductor Class | Nominal OD (mm) | Copper Index (kg/km) | Approx. Weight (kg/km) | Typical Panel & Fixture Duty |
|---|---|---|---|---|---|
| SiD/GL 1x0.5 mm² | IEC 60228 Class 1 Solid | 2.4 | 4.8 | 11.0 | Luminaires, thermostats & rigid terminal bridges |
| SiD/GL 1x0.75 mm² | IEC 60228 Class 1 Solid | 2.6 | 7.2 | 15.0 | Oven control panels & push-in spring terminals |
| SiD/GL 1x1.0 mm² | IEC 60228 Class 1 Solid | 2.7 | 9.6 | 17.0 | Commercial catering & sterilization switchgear |
| SiD/GL 1x1.5 mm² | IEC 60228 Class 1 Solid | 3.0 | 14.4 | 24.0 | High-ambient distribution boards & lamp holders |
| SiD/GL 1x2.5 mm² | IEC 60228 Class 1 Solid | 3.6 | 24.0 | 34.0 | Heater bank bus wiring & dry kiln junction boxes |
| SiD/GL 1x4 mm² | IEC 60228 Class 1 Solid | 4.3 | 38.0 | 56.0 | Form-holding furnace contactor interconnect leads |
| SiD/GL 1x6 mm² | IEC 60228 Class 1 Solid | 5.0 | 58.0 | 75.0 | Rigid earthing & thermal process bus jumpers |
Outer diameter ranges reflect CENELEC EN 50525-2-83 / HD 22.3 S4 wall thickness (H05SJ-K, 0.75 to 6 mm² harmonized core range; Nordic reference RHH H05SJ-K) alongside DIN VDE 0250 glass-silk braided SiF/GL (0.5 to 150 mm², plus 185 mm² and 240 mm² on request); final values are confirmed on the quotation drawing.
Above +100 °C ambient in hermetically sealed enclosures without air exchange, silicone elastomer mechanical strength can degrade prematurely via hydrolysis reversion; maintain cabinet ventilation or upgrade to fluoropolymer (PTFE/PFA) leads for sealed housings.
Fine hook-up cross-sections (0.5 to 2.5 mm²) are supplied on 300 m or 500 m standard factory spools per colour, while heavy feeder cross-sections (4 to 150 mm²) support a minimum order quantity of 50 m with a production lead time of 7 to 45 working days.
ASCII part references for BOM and ERP entry: TF-H05SJK-1X0.75; TF-H05SJK-1X1.0; TF-H05SJK-1X1.5; TF-H05SJK-1X2.5; TF-H05SJK-1X4; TF-H05SJK-1X6; TF-SIFGL-1X10; TF-SIFGL-1X16; TF-SIFGL-1X25; TF-SIFGL-1X35; TF-SIFGL-1X50; TF-SIFGL-1X70; TF-SIFGL-1X95; TF-SIFGL-1X120; TF-SIFGL-1X150; TF-SIDGL-1X1.5.
H05SJ-K & SiF/GL Harmonized EN, IEC & DIN VDE Reference Standards
| Standard or specification | Application |
|---|---|
| EN 50525-2-83 / CENELEC HD 22.3 S4 / IEC 60245-3 | European harmonized construction, EI2 silicone insulation wall schedule and 2,000 V AC spark/dielectric verification basis for H05SJ-K (0.75 to 6 mm²). |
| DIN VDE 0250 & DIN VDE 0282-3 | German industrial silicone single-core reference governing SiF/GL (0.5 to 240 mm² Class 5) and SiD/GL (0.5 to 6 mm² Class 1) extended cross-sections. |
| IEC 60228 / DIN EN 60228 (Class 5 & Class 1) | Conductor DC resistance at 20 °C and fine-stranded or solid tinned copper stranding geometry. |
| IEC 60754-1, IEC 60754-2 & IEC 60332-1-2 | Zero halogen acid gas evolution, low gas acidity/conductivity and single vertical wire flame-retardance testing. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine 2,000 V AC spark/dielectric verification
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
High Temperature Silicone Rubber SIAF/GL Cable with Fiberglass Braid
A related cable option for a different application or duty profile.
View productSiF Single-Core Flexible Silicone Wire & Power Lead (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productHigh Temperature Silicone Rubber SIA / SIAF Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.