Four-core flexible instrumentation cable for low-power circuits up to 60 V. EPR insulation and a chloroprene rubber sheath are available as unscreened K-PNCT or overall-braid-screened K-PNCT-SB.

Product information
Brand
TEBAOFLEX
Product overview

K-PNCT cable connects instruments and measurement equipment in low-power circuits up to 60 V. The construction uses flexible stranded conductors, EPR insulation and a chloroprene rubber sheath, with an 80°C temperature rating. K-PNCT is the unscreened version; K-PNCT-SB adds an overall braided screen around the four insulated cores.

The family is intended for semi-fixed instrument connections where cable flexibility helps installation and equipment handling. Civil engineering measurement systems are a typical application. Choose the screened version when the instrument circuit calls for an overall screen, then coordinate its termination with the equipment grounding arrangement. The screen surrounds the complete core group rather than individual cores or pairs.

Both versions are listed in 4 × 0.3 mm² and 4 × 0.5 mm² sizes. The larger conductor size reduces the maximum conductor resistance, while the screened construction changes the finished diameter and cable mass. Use the separate model tables to choose the cable entry, sealing gland and connection space for the required version.

For a quotation, provide the exact K-PNCT or K-PNCT-SB designation, conductor size, cable length and instrument circuit details. Include the installation layout and handling conditions so the selected construction suits the route. Where the project requires fixed instrumentation wiring or a higher-voltage flexible signal circuit, compare the related cable families by installation method and circuit requirements.

Explore the port and festoon cable range for related configurations.

When specifying K-PNCT or braided-shield K-PNCT-SB flexible rubber instrumentation cable alongside power or video crane circuits, compare these JIS constructions: 600V 2PNCT Flexible Rubber Cable (JIS C 3327) (600 V JIS C 3327 EPDM/chloroprene flexible rubber power cable for crane motors and heavy portable tools); ENCT 75 Ohm Flexible Coaxial Cable for Festoon Systems (75 Ohm chloroprene-sheathed flexible coaxial cable for crane spreader cameras and festoon video links). Separate low-voltage instrumentation pairs from unshielded power conductors or specify K-PNCT-SB copper braid screening.

Construction

Construction

The illustration shows K-PNCT-SB 4 × 0.5 mm²: four insulated signal cores arranged as a compact two-by-two group, surrounded by filler, tapes, an overall braid and a rubber sheath.

K-PNCT-SB 4 × 0.5 mm² cross-section showing four EPR-insulated cores, overall braid and chloroprene sheath
Representative cable construction.
K-PNCT / K-PNCT-SB Flexible Instrumentation Cable construction
ComponentMaterial and construction
ConductorsFlexible stranded conductors: 12 × 0.18 mm for 0.3 mm² or 20 × 0.18 mm for 0.5 mm².
Separator and insulationA separator over each conductor, followed by 0.5 mm EPR insulation.
Core identificationFour cores identified by black, white, red and green colours or tracers.
K-PNCT assemblyFour insulated cores within a chloroprene rubber sheath; unscreened construction.
K-PNCT-SB assemblyFour cores assembled with filler and an inner tape, followed by a 0.3 mm overall shield braid and an outer tape.
Outer sheathChloroprene rubber; wall thickness and finished diameter depend on the model and conductor size.
Applications

Applications

K-PNCT and K-PNCT-SB serve semi-fixed, low-power instrument circuits where flexible rubber cable construction is required.

Flexible black instrumentation cable connecting a civil engineering sensor enclosure to a supported measurement connection box
Application illustration.
  • Civil engineering measurement equipment and associated sensor connections.
  • Low-power instrument circuits up to 60 V.
  • Semi-fixed connections between measuring equipment, connection boxes and data-acquisition equipment.
  • K-PNCT-SB for circuits requiring an overall braided screen; terminate the screen according to the instrument system design.
  • Use supported routes and strain relief at cable entries, with sufficient space for handling and smooth bends.

For fixed process-plant instrumentation standards or heavy motorized reel cables operating alongside K-PNCT control loops, review these references: PAS 5308 and BS 5308 Instrumentation Cable: Specification Guide (engineering guide to collective and individual screen designs, pair twist lays, and PE/XLPE/PVC insulation in fixed instrumentation cables); PNCT Reeling Cable 600 V–1 kV — Round, Flat and Reinforced Types (600 V–1 kV round, flat, and aramid-reinforced PNCT reeling cables for crane travel drives). Verify whether your circuit requires fixed plant instrumentation cable or dynamic elastomeric K-PNCT.

Specifications

Specifications

K-PNCT / K-PNCT-SB Flexible Instrumentation Cable technical data
ParameterValue
Circuit applicationLow-power instrumentation circuits up to 60 V
Temperature rating80°C
Core count4
Conductor sizes0.3 and 0.5 mm²
Insulation / outer sheathEPR / chloroprene rubber
Screen optionK-PNCT: unscreened; K-PNCT-SB: overall braid
Minimum insulation resistance at 20°C500 MΩ·km
Maximum conductor resistance at 20°C66.3 Ω/km for 0.3 mm²; 39.8 Ω/km for 0.5 mm²
Installation methodSemi-fixed instrument connections requiring flexibility
Construction featuresFlexible construction with weather resistance and sheath sealing performance
K-PNCT unscreened four-core cable: complete configuration table
Model and configuration (mm²)Conductor strands (No. × mm)Conductor OD (mm)EPR insulation (mm)CR sheath (mm)Approx. cable OD (mm)Approx. mass (kg/km)Max. conductor resistance at 20°C (Ω/km)Min. insulation resistance at 20°C (MΩ·km)
K-PNCT 4 × 0.312 × 0.180.70.51.26.86566.3500
K-PNCT 4 × 0.520 × 0.181.00.51.37.78539.8500
K-PNCT-SB overall-screened four-core cable: complete configuration table
Model and configuration (mm²)Conductor strands (No. × mm)Conductor OD (mm)EPR insulation (mm)Braid thickness (mm)CR sheath (mm)Approx. cable OD (mm)Approx. mass (kg/km)Max. conductor resistance at 20°C (Ω/km)Min. insulation resistance at 20°C (MΩ·km)
K-PNCT-SB 4 × 0.312 × 0.180.70.50.31.17.67566.3500
K-PNCT-SB 4 × 0.520 × 0.181.00.50.31.28.59539.8500

The four cores are signal-circuit conductors. Specify the instrument terminal assignment together with the cable designation.

Screened and unscreened models have different sheath walls, finished diameters and masses; select the table for the ordered model.

Conductor and insulation resistance values apply at 20°C.

Dimensions and masses are nominal selection data. Include the cable route and equipment entry dimensions with the enquiry.

Standards

Standards

K-PNCT / K-PNCT-SB Flexible Instrumentation Cable standards and test references
Standard or specificationApplication
K-PNCT construction referenceModel-specific four-core EPR-insulated, chloroprene-sheathed instrumentation construction.
K-PNCT-SB construction referenceOverall-braid-screened version with filler and tapes around the four-core assembly.
Circuit and temperature scopeLow-power measurement circuits up to 60 V; temperature rating 80°C.
Resistance measurement conditionsConductor resistance and insulation resistance values specified at 20°C.
Core identificationColour and tracer identification using black, white, red and green for four-core constructions.
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.