MINING & TUNNELING CABLES TEBAOFLEX

MSHA Double-Jacket 600V Remote Control and Drill Cord

Extra-heavy-duty 600 V double-jacketed remote control, pendent switch and handheld coal/rock drill cord engineered to ICEA S-75-381 / NEMA WC 58 and MSHA flame-resistance requirements in 14 AWG, 12 AWG and 10 AWG (2 to 6 conductors). Features Class K tinned copper conductors, 90 C EPR insulation and a dual-layer contrasting inner/outer thermoset CPE/PCP sheath for visual abrasion wear indication. MOQ 50 m; lead time 7 to 45 working days.

Product information
SKU
MSHA-DJ-DRILL-CORD
Brand
TEBAOFLEX
Product overview

Handheld underground coal and rock drills, roof-bolter pendent stations, continuous-miner umbilical remote controls and conveyor pull-cord switches operate in the immediate face zone where small-diameter cords suffer constant rib abrasion, boot trampling and coal-slurry immersion. Standard single-jacket portable cords can wear through to energized insulation without warning; MSHA Double-Jacket 600 V Remote Control and Electric Drill Cord solves this hazard with a two-layer contrasting thermoset sheath architecture.

Engineered to ICEA S-75-381 / NEMA WC 58 and UL 62 / CSA C22.2 No. 49 heavy-duty cord schedules, this construction pairs finely stranded Class K (30 AWG strand) annealed tinned copper conductors in 14 AWG, 12 AWG and 10 AWG (2 to 6 cores) with 90 C thermoset EP/EPR rubber insulation. The cabled core is enclosed in a high-visibility yellow or orange elastomeric inner jacket bonded or reinforced under a tough black MSHA-accepted flame-retardant polychloroprene (PCP) or chlorinated polyethylene (CPE) outer jacket.

When drag abrasion along coal ribs or steel chutes wears through the outer black sheath, the contrasting yellow inner jacket becomes immediately visible during pre-shift safety inspections before dielectric integrity is compromised. TEBAOFLEX supplies both standard double-jacket and synthetic-braid-reinforced drill cords from a 50 m MOQ with a 7 to 45 working day lead time.

Explore the mining and tunneling cable range for related configurations.

Construction

MSHA Double-Jacket 600V Remote Control and Drill Cord Construction & Layer Breakdown

The representative horizontal sample illustrates the 4C x 12 AWG 600 V MSHA Double-Jacket Remote Control and Drill Cord, showing four rope-flexible Class K tinned copper conductors with color-coded 90 C EPR insulation (black, white, red, green), an extruded contrasting yellow elastomeric wear-indicator inner jacket, optional open-weave synthetic reinforcing braid and a heavy black MSHA flame-retardant CPE/PCP outer jacket.

Flat 2D cross-section diagram of MSHA Double-Jacket 600 V drill cord showing 4 colour-coded EPR cores with tinned copper strands, yellow inner jacket, reinforcing braid and black outer jacket
Cross-section of MSHA Double-Jacket 600 V drill cord showing 4 Class K tinned copper EPR-insulated cores inside a high-visibility yellow inner wear-indicator jacket and black outer MSHA CPE sheath.
MSHA Double-Jacket 600V Remote Control and Drill Cord construction
ComponentMaterial and construction
Conductors (2 to 6 x Class K Tinned Copper)Bunch-/rope-stranded Class K (0.254 mm / 30 AWG individual strands) annealed tinned copper conductors per ASTM B174 / B33 for high-cycle flexing.
90 C Thermoset EPR InsulationColour-coded (black, white, red, green, orange, blue per ICEA Method 1) 90 C ethylene propylene rubber (EPR) insulation resisting ozone, moisture and crushing.
Core Lay & Elastomeric FillersShort pitch helical core lay with non-wicking rubber fillers or full interstitial extrusion for a round, kink-resistant cross-section.
Contrasting Wear-Indicator Inner JacketExtruded high-visibility yellow or orange thermoset elastomeric inner jacket providing mechanical cushioning and visual abrasion warning.
Optional Synthetic Reinforcing BraidOpen-weave high-tenacity synthetic cord braid between the inner and outer jackets on reinforced handheld drill cord variants.
Outer MSHA Flame-Retardant CPE/PCP JacketExtra-heavy-duty black oil-, cut- and flame-resistant thermoset CPE or neoprene (PCP) outer jacket passing MSHA 30 CFR Part 18 flame test criteria.

MSHA Double-Jacket 600V Remote Control and Drill Cord Designation Breakdown

  • MSHA 30 CFR Part 18: Mine Safety and Health Administration flame-resistance acceptance marking embossed on the outer jacket for underground coal and gassy mine faces
  • DJ-RC 600V: Double-Jacket Remote Control Cord — 600 V Class K tinned-copper multi-conductor cord (14 AWG, 12 AWG and 10 AWG, 2 to 6 cores) with two distinct elastomeric sheaths
  • DJ-Drill-Reinforced 600V: Braid-reinforced heavy-duty handheld drill cord incorporating an open-weave high-tenacity synthetic braid between the inner and outer jackets
  • Contrasting Inner Jacket: High-visibility yellow or orange thermoset CPE/EPR inner sheath providing an immediate visual wear indicator when the black outer jacket is cut or abraded
  • Class K + 90 °C EPR / CPE: Finely stranded 30 AWG tinned copper conductors per ASTM B174 with 90 °C EPR core insulation and oil/emulsion-resistant MSHA CPE or PCP outer jacket
Applications

MSHA Double-Jacket 600V Handheld Coal Drill, Remote Pendant & Solenoid Applications

Specify MSHA Double-Jacket 600 V Remote Control and Drill Cord wherever portable 600 V handheld tools, operator pendents or face-zone safety switches require visual sheath-wear detection.

Underground miner operating a handheld roof-bolter remote control pendent connected via a rugged MSHA double-jacket 600 V cord
MSHA Double-Jacket 600 V remote control and drill cords powering handheld coal drills and continuous-miner control pendants at an underground mine face.
  • Handheld electric rotary coal drills, pneumatic-electric roof bolting controls and portable face pumps in underground coal and trona mines.
  • Continuous miner, roadheader and LHD scooptram tethered operator remote-control pendent cords exposed to floor rock and rib abrasion.
  • Longwall armored face conveyor (AFC) lockout pull-switches, belt-alignment trip switches and stage-loader emergency stop circuits.
  • Heavy industrial foundry, tunnel boring and quarry maintenance tool drops where contrasting double-jacket wear indication prevents shock hazards.

MSHA Double-Jacket 600V Drill Cord vs Single-Jacket SOOW & Multi-Core SOOW Selection Matrix

MSHA Double-Jacket 600 V Remote Control & Drill Cord vs Single-Jacket SOOW & Multi-Core SOOW Comparison
Cord SeriesCore Count & Size RangeJacket & Wear-Indicator ConstructionPrimary Underground / Surface Duty
MSHA Double-Jacket (DJ-RC 600V)2 to 6 cores (14 AWG, 12 AWG, 10 AWG)Contrasting yellow/orange inner jacket + heavy black MSHA CPE/PCP outer jacketRemote-control pendants, roof-bolter solenoid valves and handheld coal/rock face tools
MSHA Braid-Reinforced (DJ-Drill-Reinforced)3x14 AWG, 4x12 AWG, 4x10 AWG (600 V)Yellow/orange inner jacket + open-weave synthetic reinforcing braid + black MSHA CPE/PCP sheathHigh-pull handheld rotary coal drills and face equipment dragged across blasted muck piles
Single-Jacket Type SOOW (2–5C)2 to 5 cores (18 AWG to 2 AWG)Single-layer oil- and weather-resistant thermoset CPE/EPDM jacket without inner wear layerGeneral industrial portable tools, pumps and light surface auxiliary power cords
SOOW Multi-Core Control (5–60C)5 to 60 cores (18 AWG to 10 AWG)Planetary multi-core lay with separator tape and single heavy CPE outer jacketMulti-channel PLC I/O trunks, dragline festoons and longwall valve-bank control harnesses

Specify MSHA Double-Jacket DJ-RC or DJ-Drill-Reinforced 600 V cord whenever underground coal/metal mine safety rules require a contrasting inner wear-indicator sheath to expose outer jacket cuts before core insulation is breached.

Related selection resources

MSHA Double-Jacket 600V Remote Control and Drill Cord Engineering FAQ

How does the contrasting inner jacket work on MSHA Double-Jacket 600 V Drill Cord?

The cable uses a two-layer sheath architecture: an inner jacket extruded in high-visibility yellow or orange thermoset CPE/EPR and an outer jacket in heavy-duty black MSHA flame-retardant CPE or polychloroprene (PCP). When rock abrasion or pinch cuts through the black outer sheath on a coal face, the bright yellow or orange inner layer becomes immediately visible to the operator so the cord can be repaired or replaced before the 90 °C EPR core insulation is exposed.

When should I choose DJ-Drill-Reinforced over standard DJ-RC 600 V cord?

Standard DJ-RC 600 V (2 to 6 cores in 14 AWG, 12 AWG and 10 AWG) is ideal for operator remote-control pendants, solenoid banks and light portable tools. Choose DJ-Drill-Reinforced (3x14 AWG, 4x12 AWG or 4x10 AWG) for handheld rotary coal drills and face equipment that are repeatedly yanked or dragged under tension, as the open-weave synthetic braid between the two jackets boosts tensile pull and tear resistance.

Why are Class K tinned copper conductors used in MSHA Double-Jacket 600 V cord?

Class K stranding (built from fine 30 AWG wires per ASTM B174) provides a tight 5 x O.D. minimum bend radius and high flex-fatigue life at operator wrists and cable entries, while the tin coating prevents copper sulphide corrosion from rubber curing and acidic mine water.

What are the MOQ and delivery lead time for MSHA Double-Jacket 600 V Remote Control and Drill Cord?

TEBAOFLEX supplies MSHA Double-Jacket 600 V DJ-RC and DJ-Drill-Reinforced cords from a 50 m MOQ with a manufacturing lead time of 7 to 45 working days.

Specifications

MSHA Double-Jacket 600V Remote Control and Drill Cord Technical Specifications & Size Schedule

MSHA Double-Jacket 600V Remote Control and Drill Cord Key Electrical & Wear-Indicator Ratings

  • Standard & Models: MSHA 30 CFR Part 18, ICEA S-75-381 / NEMA WC 58 and UL 62 Double-Jacket Remote Control (DJ-RC) and Drill Cord
  • Voltage & Core Range: 600 V rating across 2, 3, 4, 5 and 6 conductors in 14 AWG, 12 AWG and 10 AWG (plus braid-reinforced drill variants)
  • Conductors & Insulation: Class K (30 AWG strand) flexible tinned copper per ASTM B174 / B33 with -40 °C to +90 °C thermoset EPR insulation
  • Wear-Indicator Sheath: High-visibility yellow/orange inner jacket under black MSHA oil- and flame-resistant CPE/PCP outer sheath
  • Commercial Terms: MOQ 50 m; manufacturing lead time 7 to 45 working days in custom cut lengths or continuous master reels
MSHA Double-Jacket 600V Remote Control and Drill Cord technical data
ParameterValue
Design standard referenceEngineered to ICEA S-75-381 / NEMA WC 58, UL 62 / CSA C22.2 No. 49 and MSHA 30 CFR Part 18 flame test criteria
Rated voltage & conductor sizes600 V rating across 14 AWG (2.08 mm2), 12 AWG (3.31 mm2) and 10 AWG (5.26 mm2) in 2, 3, 4, 5 and 6 conductors
Double-jacket safety mechanismBlack outer CPE/PCP sheath over contrasting yellow/orange inner elastomeric sheath reveals outer jacket cuts before core exposure
Operating temperature range-40 C cold-flex to +90 C continuous conductor temperature in wet or dry mine locations
Minimum dynamic bend radius6 x overall cord diameter for continuous flexing and handheld tool handling
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days on wooden reels or coils
Selection boundary vs SOOW Multi-CoreSelect Double-Jacket 600 V Cord (2 to 6 cores, 14 to 10 AWG) for handheld drills and pendents; select SOOW Multi-Core (5 to 60 cores) for multi-channel control harnesses.

MSHA Double-Jacket 600 V Remote Control & Drill Cord (14 AWG & 12 AWG, 2 to 6 Conductors) Schedule

MSHA Double-Jacket 600 V Remote Control & Electric Drill Cord (14 AWG & 12 AWG, 2 to 6 Conductors) — Nominal Dimensions & Ampacity
Part DesignationNo. of CoresConductor SizeClass K StrandingEPR Insulation Wall (mm)Dual Jacket Wall (mm)Nominal Overall O.D. (mm)Approx. Net Mass (kg/km)Ampacity at 30 °C Ambient (A)Next step
DJ-RC 600V 2x14 AWG214 AWG (2.08 mm²)41/301.142.412.419518Request this size
DJ-RC 600V 3x14 AWG314 AWG (2.08 mm²)41/301.142.413.223518Request this size
DJ-RC 600V 4x14 AWG414 AWG (2.08 mm²)41/301.142.414.528515Request this size
DJ-RC 600V 5x14 AWG514 AWG (2.08 mm²)41/301.142.515.834012Request this size
DJ-RC 600V 6x14 AWG614 AWG (2.08 mm²)41/301.142.517.139512Request this size
DJ-RC 600V 2x12 AWG212 AWG (3.31 mm²)65/301.142.513.824525Request this size
DJ-RC 600V 3x12 AWG312 AWG (3.31 mm²)65/301.142.514.730525Request this size
DJ-RC 600V 4x12 AWG412 AWG (3.31 mm²)65/301.142.516.037520Request this size
DJ-RC 600V 5x12 AWG512 AWG (3.31 mm²)65/301.142.617.645016Request this size
DJ-RC 600V 6x12 AWG612 AWG (3.31 mm²)65/301.142.619.152516Request this size

MSHA Double-Jacket 600 V Heavy-Duty Drill & Auxiliary Control Cord (10 AWG & Braid-Reinforced) Schedule

MSHA Double-Jacket 600 V Heavy Drill Cord (10 AWG & Braid-Reinforced Series) — Nominal Dimensions & Ampacity
Part DesignationNo. of CoresConductor SizeStranding & ReinforcementEPR Insulation Wall (mm)Dual Jacket Wall (mm)Nominal Overall O.D. (mm)Approx. Net Mass (kg/km)Ampacity at 30 °C Ambient (A)Next step
DJ-RC 600V 2x10 AWG210 AWG (5.26 mm²)104/301.142.815.633530Request this size
DJ-RC 600V 3x10 AWG310 AWG (5.26 mm²)104/301.142.816.842030Request this size
DJ-RC 600V 4x10 AWG410 AWG (5.26 mm²)104/301.142.818.452024Request this size
DJ-RC 600V 5x10 AWG510 AWG (5.26 mm²)104/301.143.020.263020Request this size
DJ-RC 600V 6x10 AWG610 AWG (5.26 mm²)104/301.143.021.874520Request this size
DJ-Drill-Reinforced 600V 3x14 AWG314 AWG (2.08 mm²)41/30 + Braid1.142.814.026018Request this size
DJ-Drill-Reinforced 600V 4x12 AWG412 AWG (3.31 mm²)65/30 + Braid1.143.016.841020Request this size
DJ-Drill-Reinforced 600V 4x10 AWG410 AWG (5.26 mm²)104/30 + Braid1.143.219.256524Request this size

Current ratings are based on 30 C ambient air per NEC Table 400.5(A)(1) / ICEA S-75-381 for 2-core, 3-core and 4-to-6-core portable cords.

Reverse jacket colours (yellow outer jacket with black inner wear-indicator jacket) can be specified for high-visibility rib routing.

ASCII part references for BOM and ERP entry: DJ-RC 600V 2x14 AWG, DJ-RC 600V 3x14 AWG, DJ-RC 600V 4x14 AWG, DJ-RC 600V 5x14 AWG, DJ-RC 600V 6x14 AWG, DJ-RC 600V 2x12 AWG, DJ-RC 600V 3x12 AWG, DJ-RC 600V 4x12 AWG, DJ-RC 600V 5x12 AWG, DJ-RC 600V 6x12 AWG, DJ-RC 600V 2x10 AWG, DJ-RC 600V 3x10 AWG, DJ-RC 600V 4x10 AWG, DJ-RC 600V 5x10 AWG, DJ-RC 600V 6x10 AWG, DJ-Drill-Reinforced 600V 3x14 AWG, DJ-Drill-Reinforced 600V 4x12 AWG, DJ-Drill-Reinforced 600V 4x10 AWG.

Standards

MSHA Double-Jacket 600V Remote Control and Drill Cord Applicable Standards & Related Cords

MSHA Double-Jacket 600V Remote Control and Drill Cord standards and test references
Standard or specificationApplication
ICEA S-75-381 / NEMA WC 58Portable and power feeder cables for use in mines (heavy-duty double-jacket portable cord construction and physical tests).
UL 62 & CSA C22.2 No. 49Flexible cords and cables — 600 V thermoset oil-, water- and weather-resistant cord dielectric and mechanical endurance.
ASTM B174 & ASTM B33Bunch-stranded Class K flexible annealed tinned copper conductors (30 AWG wires).
MSHA 30 CFR Part 18Flame-resistance acceptance test criteria for underground coal mine portable cords and control cables.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

NEMA — WC 58 / ICEA S-75-381 Heavy-Duty Portable Mining Cord Standard

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.