BFCU, BFCU(i) & BFCU(c) NEK 606 Fire-Resistant Armoured Offshore Cable (0.6/1 kV & 250 V)
BFCU, BFCU(i) and BFCU(c) are NEK TS 606 fire-resistant, mud-resistant, halogen-free offshore power (0.6/1 kV) and instrumentation (150/250 V) cables armored with galvanized steel wire braiding (GSWB). Combining tinned copper conductors, phlogopite mica glass fire-barrier tape (180-minute IEC 60331 circuit integrity), 90 °C EPR insulation, halogen-free inner bedding and a thermoset SHF2 mud-resistant outer sheath rated -40 °C to +90 °C, they withstand both hydrocarbon fires and mechanical deck impacts on drilling rigs and FPSOs.
BFCU, BFCU(i) and BFCU(c) form the steel-braid-armoured, fire-resistant offshore cable family under Norwegian standard NEK TS 606 and IEC 60092-353/-376 for oil and gas drilling platforms, jack-ups, semi-submersibles and FPSO topside process modules.
While copper-braided BFOU dominates general offshore fire-survival runs, exposed pipe-racks, drill-floor perimeters, subsea-control riser bays and outdoor module walkways require stronger mechanical crush resistance and steel armour grounding. Substituting a galvanized steel wire braid ('C' in BFCU) over the extruded halogen-free inner covering ('F') delivers rugged mechanical armouring without sacrificing compact 10 × D offshore tray routing. Beneath the armour, every tinned stranded copper conductor carries overlapping phlogopite mica fire-barrier tape ('B') and 90 °C EPR insulation, finished in a cross-linked SHF2 mud-resistant, zero-halogen outer jacket ('U') capable of surviving drilling fluids, H2S mist and direct flame exposure.
Choose BFCU (0.6/1 kV) for fire-water deluge pumps, ESD valves, emergency generators and blow-out preventer backups; specify BFCU(i) (individual pair/triple Al-PES foil + overall screen) or BFCU(c) (collective foil screen) at 150/250 V for fire/gas detection and ESD telemetry. Where tinned copper braid EMC shielding is preferred over steel armour, choose NEK 606 BFOU; where flame retardance without mica survival suffices, choose RFOU or RFCU. Minimum order 50 m; lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
BFCU, BFCU(i) & BFCU(c) NEK 606 Mica-Barrier & GSWB Construction
NEK TS 606 fire-survival offshore architecture pairing tinned copper, phlogopite mica tape, 90 °C EPR insulation, extruded halogen-free bedding, galvanized steel wire braid armour and SHF2 mud-resistant outer sheath.

| Component | Material and construction |
|---|---|
| 1. Stranded Tinned Electrolytic Copper Conductor | IEC 60228 Class 2 or flexible Class 5 tinned copper (1.5–300 mm² for 0.6/1 kV BFCU power; 0.75–2.5 mm² for 250 V BFCU(i)/(c) pairs and triples). |
| 2. Phlogopite Mica Fire-Barrier Tape & 90 °C EPR Insulation | Overlapping mica glass tape directly on each conductor beneath halogen-free cross-linked EPR insulation designed for 180-minute IEC 60331 circuit integrity. |
| 3. Pair/Triple Foil Screening (BFCU(i) / BFCU(c)) & Halogen-Free Inner Bedding | BFCU(i) applies individual aluminum-polyester foil + tinned drain per pair/triple plus overall screen; BFCU(c) applies collective foil screen, all beneath an extruded halogen-free inner covering (F). |
| 4. Galvanized Steel Wire Braid Armour (GSWB) | High-coverage galvanized steel wire braid (letter code 'C') providing mechanical crush, impact and abrasion protection across exposed offshore decks. |
| 5. Mud-Resistant Thermoset SHF2 Outer Sheath (U) | Cross-linked low-smoke, zero-halogen SHF2 compound (grey standard, orange emergency or blue Ex-i) resistant to drilling mud, mineral oils and UV from -40 °C to +90 °C. |
BFCU NEK TS 606 Designation Letter-Code Breakdown
- B: Fire-resistant construction: overlapping phlogopite mica glass tape + 90 °C EPR insulation (IEC 60331, 180 min)
- F: Extruded halogen-free flame-retardant inner covering / bedding
- C: Galvanized steel wire braid armour (GSWB) for mechanical crush and deck-impact resistance
- U: Thermoset cross-linked halogen-free SHF2 outer sheath resistant to offshore drilling muds
- (i) / (c): 250 V instrumentation tiers: (i) = individual + overall Al-PES foil screen; (c) = collective foil screen
BFCU Offshore Rig, FPSO Topside & ESD Safety Applications
Engineered for fixed fire-survival emergency power, ESD shutdown and safety instrumentation across severe mud- and impact-exposed offshore oil and gas decks.

- Emergency fire-water deluge pumps, foam skids, emergency diesel generators and muster-station power trunks on offshore drilling rigs.
- Blow-out preventer (BOP) controls, wellhead emergency shutdown (ESD) actuators and exposed pipe-rack power runs requiring steel-braid mechanical armour.
- BFCU(i) individually screened 250 V fire-and-gas detector loops, H2S sensors and safety-PLC analog telemetry near high-current motor feeders.
- BFCU(c) collectively screened emergency PA/GA evacuation speakers, lifeboat communications and offshore platform radar/beacon loops.
BFCU (GSWB) vs BFOU (Cu Braid) vs M2XCH-FFR Selection
| Cable Series | Metallic Layer | Fire & Mud Tier | Primary Offshore / Marine Use |
|---|---|---|---|
| BFCU / BFCU(i) / BFCU(c) (this page) | Galvanized steel wire braid (GSWB) | Mica 180 min + SHF2 Mud-Res. | Impact-exposed rig decks, pipe-racks & offshore ESD circuits |
| BFOU / BFOU(i) / BFOU(c) | Tinned copper wire braid | Mica 180 min + SHF2 Mud-Res. | General offshore fire-survival & high-EMC topside modules |
| RFOU / RFCU | Tinned Cu (O) or GSWB (C) | Flame-retardant + SHF2 Mud | Non-emergency offshore power & process control feeders |
| M2XH-FFR / M2XCH-FFR | Unscreened or 90% Cu braid | Mica IEC 60331 + SHF1 LSZH | Commercial merchant shipboard emergency circuits (no mud) |
Select BFCU over BFOU whenever mechanical steel-braid armouring is mandated by offshore deck mechanical-risk zoning.
BFCU, BFCU(i) & BFCU(c) Offshore Cable RFQ Checklist
- Exact NEK 606 code: BFCU (0.6/1 kV power/control), BFCU(i) (250 V individual+overall screened) or BFCU(c) (250 V collective screened).
- Core, pair or triple count and conductor cross-section (0.75–300 mm², Class 2 or Class 5 tinned copper).
- Outer SHF2 mud-resistant jacket color (grey standard, orange emergency fire circuit or RAL 5015 blue Ex-i).
- Order length per size (MOQ 50 m), cold-climate rating (-15 °C standard or -40 °C Arctic) and any witnessed test scope.
Related selection resources
- Compare Tinned-Copper Braided NEK 606 BFOU Offshore Cables
- Explore BFOU VFD 1.8/3 kV Symmetrical Fire-Resistant Offshore VFD Cables
- Compare Flame-Retardant NEK 606 RFOU Mud-Resistant Offshore Cables
- Compare Commercial Shipboard M2XH-FFR & M2XCH-FFR Cables
- Browse Complete Marine & Offshore Cable Catalog
- Explore Marine & Offshore Designation Solutions Hub
BFCU, BFCU(i) & BFCU(c) NEK 606 Offshore Cable FAQ
What is the difference between NEK 606 BFCU and BFOU offshore cables?
Both are 0.6/1 kV and 250 V mica fire-resistant, SHF2 mud-resistant NEK TS 606 offshore cables, but BFCU uses galvanized steel wire braid armour ('C') for higher mechanical crush resistance whereas BFOU uses tinned copper wire braiding ('O') for lightweight EMC shielding.
How do BFCU(i) and BFCU(c) differ for 250 V offshore instrumentation?
BFCU(i) shields every 250 V twisted pair or triple with an individual aluminum-polyester foil plus drain wire inside an overall foil screen to stop adjacent-channel crosstalk, whereas BFCU(c) applies a single collective foil screen over all pairs beneath the galvanized steel braid.
How long do BFCU, BFCU(i) and BFCU(c) maintain circuit integrity during fire?
180 minutes under IEC 60331 direct flame exposure: overlapping phlogopite mica glass tapes wrapped directly over every tinned copper conductor preserve insulation resistance after outer polymers char.
Are BFCU offshore cables resistant to oil-based drilling muds at -40 °C?
Yes. The thermoset cross-linked SHF2 outer sheath ('U') is formulated to resist oil-based and synthetic drilling fluids across -40 °C to +90 °C fixed offshore service.
What is the MOQ and manufacturing lead time for NEK 606 BFCU cables?
50 m minimum order per size, custom-manufactured in 7 to 45 working days with full factory routine electrical and dimensional test records.
BFCU, BFCU(i) & BFCU(c) Dimension & Weight Schedule
BFCU Electrical, Fire-Survival & Mud-Resistance Ratings
- Galvanized steel wire braid armour (C): Replaces copper braiding with high-strength galvanized steel wire braiding (GSWB) for superior crush and deck-impact protection
- 180-minute mica fire-survival barrier (B): Overlapping phlogopite mica glass tape over every tinned copper conductor sustains live emergency circuits per IEC 60331
- Power (BFCU) & screened signal (BFCU(i)/BFCU(c)): 0.6/1 kV power/control (1–37 cores, 1.5–300 mm²) plus 250 V individual+overall (i) and collective (c) foil-screened pairs/triples
- Mud-resistant thermoset SHF2 outer sheath (U): Engineered to resist oil-based drilling muds, mineral oils, salt spray and ozone from -40 °C to +90 °C (IEC 60092-360 SHF2)
- 50 m MOQ and custom offshore dispatch: Available in grey, orange (fire-safety) or blue (Ex-i) SHF2 jackets, manufactured to order in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (3.5 kV test) for BFCU power; 150/250 V AC (1.5 kV test) for BFCU(i) and BFCU(c) instrumentation |
| Fire resistance design reference | Phlogopite mica fire barrier engineered for 180-minute IEC 60331-21 circuit integrity during direct fire |
| Operating temperature range | -40 °C to +90 °C continuous service (-15 °C minimum installation; 250 °C short-circuit) |
| Armour and mud-resistant sheath | Galvanized steel wire braid armour (GSWB) under thermoset SHF2 drilling-mud resistant halogen-free jacket |
| Minimum bending radius | 10 × D fixed installation across BFCU power, BFCU(i) and BFCU(c) armoured builds |
| Minimum order and lead time | 50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days |
BFCU, BFCU(i) & BFCU(c) NEK 606 Dimension & Weight Schedule
| Model & Size (mm²) | Voltage & Screen Tier | Armour & Sheath | Nominal OD (mm) | Approx. Weight (kg/km) | Copper Weight (kg/km) | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| BFCU 1×95 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 21.4 | 1,350 | 912 | 50 m | Request this size |
| BFCU 2×2.5 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 13.5 | 350 | 48 | 50 m | Request this size |
| BFCU 3×16 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 23.2 | 1,150 | 461 | 50 m | Request this size |
| BFCU 4×50 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 34.9 | 3,010 | 1,920 | 50 m | Request this size |
| BFCU 4×95 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 45.6 | 5,790 | 3,648 | 50 m | Request this size |
| BFCU 5×10 | 0.6/1 kV Power | GSWB + SHF2 Mud-Res. | 22.9 | 1,090 | 480 | 50 m | Request this size |
| BFCU 12×1.5 | 0.6/1 kV Control | GSWB + SHF2 Mud-Res. | 21.3 | 890 | 173 | 50 m | Request this size |
| BFCU 24×2.5 | 0.6/1 kV Control | GSWB + SHF2 Mud-Res. | 30.1 | 2,010 | 576 | 50 m | Request this size |
| BFCU(i) 2×2×0.75 | 250 V Ind.+Coll. Foil | GSWB + SHF2 Mud-Res. | 17.1 | 300 | 39 | 50 m | Request this size |
| BFCU(i) 4×2×1.5 | 250 V Ind.+Coll. Foil | GSWB + SHF2 Mud-Res. | 22.6 | 550 | 135 | 50 m | Request this size |
| BFCU(i) 12×2×0.75 | 250 V Ind.+Coll. Foil | GSWB + SHF2 Mud-Res. | 29.8 | 900 | 231 | 50 m | Request this size |
| BFCU(c) 4×2×0.75 | 250 V Collective Foil | GSWB + SHF2 Mud-Res. | 19.3 | 460 | 72 | 50 m | Request this size |
| BFCU(c) 7×3×1.5 | 250 V Collective Foil | GSWB + SHF2 Mud-Res. | 29.2 | 1,430 | 308 | 50 m | Request this size |
Table values reflect EPR-insulated NEK TS 606 constructions; full size ranges cover 1×1.5 to 1×300 mm², 2–5 core up to 185 mm², 7–37 core control, and 1–24 pairs/triples in 0.75, 1.5 and 2.5 mm². Factory routine electrical tests and optional third-party witnessed inspection are available per order.
ASCII part references for BOM and ERP entry: BFCU-1x95, BFCU-2x2.5, BFCU-3x16, BFCU-4x50, BFCU-4x95, BFCU-5x10, BFCU-12x1.5, BFCU-24x2.5, BFCU-I-2x2x0.75, BFCU-I-4x2x1.5, BFCU-I-12x2x0.75, BFCU-C-4x2x0.75, BFCU-C-7x3x1.5.
BFCU NEK TS 606, IEC 60331 & IEC 60092 Standards
| Standard or specification | Application |
|---|---|
| NEK TS 606 & IEC 60092-353 / -376 | Norwegian offshore mud-resistant power (0.6/1 kV) and instrumentation (150/250 V) cable design reference. |
| IEC 60331-21 & IEC 60332-3-22 Cat. A | 180-minute direct-flame circuit integrity and vertical bunched flame-retardance reference. |
| IEC 60754-1/-2, IEC 61034-1/-2 & IEC 60092-360 (SHF2) | Zero-halogen corrosive gas, low smoke density and thermoset mud-resistant outer sheathing reference. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing quality and factory routine test records
NEK (Norwegian Electrotechnical Committee) — NEK TS 606 Cables for Offshore Installations
IEC 60092-353 — Electrical Installations in Ships: 1 kV and 3 kV Power Cables
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
VG 95218 Part 60–66 (MGSGO, MGGO, LMGSGO & FMGSGO) Naval Shipboard Cable (BV 3400)
A related cable option for a different application or duty profile.
View productNEK 606 BFOU Cable | P5/P12 Power & Instrumentation
A related cable option for a different application or duty profile.
View productBFOU VFD 1.8/3 kV Offshore Cable — 3C+3E LSZH
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.