VG 95218 Part 60–66 (MGSGO, MGGO, LMGSGO & FMGSGO) Naval Shipboard Cable (BV 3400)
VG 95218 Part 60 to Part 66 (encompassing MGSGO, MGGO, LMGSGO, FMGSGO, FMSGSGO, LFMGSSGO, LFMSGSGO and LFMSGSSGO) is the German naval BV 3400 halogen-free, low-fire-hazard, cross-linked elastomeric shipboard cable series. Covering heavy power up to AC 1,200 V / DC 1,800 V (Part 60), lightweight 550/825 V power/control (Part 61) and single/double copper-braid-screened 250/355 V naval radar and telecom pairs/triples (Parts 62–66), all builds operate from -30 °C to +90 °C with compact 4 × D to 5 × D fixed bending radii.
VG 95218 Part 60 through Part 66 (MGSGO, MGGO, LMGSGO, FMGSGO, FMSGSGO, LFMGSSGO, LFMSGSGO and LFMSGSSGO) is the flagship German naval vessel power, control, signal and telecommunication cable series engineered to VG 95218-2/-5 and BV 3400 fixed-installation requirements for frigates, corvettes, patrol vessels, minehunters, amphibious ships and defense auxiliaries.
Naval compartments impose tighter space, weight, toxic-fume and electromagnetic-compatibility ceilings than standard merchant ships. Every Part 60–66 cable pairs annealed electrolytic copper (DIN EN 60228 Class 2 or flexible Class 5) with thin-wall halogen-free cross-linked polymeric insulation and a rugged cross-linked halogen-free elastomeric outer sheath rated -30 °C to +90 °C with a tight 4 × D (flexible) or 5 × D (standard) fixed bending radius. Dash-number tables cover single- and multi-core power up to 1×300 mm² and 3×120 mm² (Part 60 Types A, B, C, D), slim 0.4 mm-wall light power/control up to 37×1.5 mm² (Part 61), and densely copper-braided twisted pairs and triples down to 0.4 mm² with individual and double overall EMC shields (Parts 62–66).
Choose VG 95218 Part 60–66 to complement our VG 95218-28 lightweight shipboard and VG 95218 naval data/coax range on complete defense-vessel cable schedules; choose DIN 89158 MGCG/MGCH or IEC 60092 M2XCH for commercial merchant hulls. All cables are manufactured to VG 95218 dimensional and electrical parameters with factory routine test documentation (no unverified defense-agency listing claimed). Minimum order 50 m; lead time 7 to 45 working days.
Explore the marine, offshore and shipboard cable range for related configurations.
VG 95218 Part 60–66 Halogen-Free Elastomeric Construction
BV 3400 zero-halogen cross-linked naval build combining DIN EN 60228 Class 2/5 copper, thin-wall cross-linked polymeric insulation, single/individual/double copper braiding and elastomeric low-smoke outer sheath.

| Component | Material and construction |
|---|---|
| 1. Stranded Electrolytic Copper Conductor (Class 2 or Class 5) | Plain annealed copper per DIN EN 60228 from 0.4 mm² (light telecom) and 0.75 mm² (telecom) up to 300 mm² (main naval power feeders). |
| 2. Halogen-Free Cross-Linked Polymeric Insulation | Compact 0.2 mm to 2.4 mm radial wall cross-linked zero-halogen insulation color- or number-coded per VG 95218 / HD 308.S2. |
| 3. Halogen-Free Common Covering & Polyester Separator Foil | Extruded halogen-free bedding (MGSGO Types B/D) or overlapping polyester binder foil keeping core bundles tight through bulkhead glands. |
| 4. Single, Individual or Double Copper Wire Braid Screen | Bare copper wire braid with separating foils (single overall on MGSGO/LMGSGO/FMGSGO; individual+overall on FMSGSGO/LFMSGSGO; double overall on LFMGSSGO/LFMSGSSGO; unscreened on MGGO). |
| 5. Halogen-Free Cross-Linked Elastomeric Outer Sheath | Matte black low-fire-hazard cross-linked elastomer meeting IEC 60332-3-24 Cat. C, IEC 60754-1/-2 and IEC 61034-1/-2 across -30 °C to +90 °C. |
VG 95218 Part 60–66 MGSGO / LMGSGO / FMGSGO Code Breakdown
- L / F / (blank): L = lightweight thin-wall (Parts 61, 64–66); F = telecom/signal pairs or triples (Parts 62–66); blank = main power
- MG: Marine shipboard cable (M) with halogen-free cross-linked elastomeric / polymeric insulation (G)
- S / SS: S = copper wire braid screen; SS = double copper wire braid screen (individual + overall or dual overall)
- GO: Halogen-free cross-linked elastomeric outer sheath (G) with zero-halogen low-fire-hazard formulation (O)
- Part 60–66 + Dash: Exact VG 95218 Part and Dash No. (e.g. Part 60 B047) defining stranding, insulation wall and OD window
VG 95218 Part 60–66 Naval Power, Radar & Combat-System Applications
Engineered for permanent above-deck and below-deck fixed electrical distribution, combat-system signal routing and radar/radio trunks on naval and coast-guard vessels.

- Main and auxiliary AC 1,200 V / DC 1,800 V power feeders across naval machinery rooms, propulsion buses and weapons-support switchboards (Part 60 MGSGO / MGGO).
- Space-saving 550 V AC / 825 V DC lighting, distribution and multi-core control panels up to 37×1.5 mm² (Part 61 LMGSGO).
- Screened and individually-braided 250 V AC / 355 V DC radio, radar, sonar and command-console pairs (Parts 62 & 63 FMGSGO / FMSGSGO).
- Ultra-compact 0.4 mm² double-braided high-EMC pair and triple instrumentation networks up to 45×2×0.4 mm² (Parts 64–66 LFMGSSGO / LFMSGSGO / LFMSGSSGO).
VG 95218 Part 60–66 vs VG 95218-28 vs DIN 89158 MGCG
| VG 95218 / Marine Family | Codes & Duty | Voltage & Shielding | Primary Vessel Scope |
|---|---|---|---|
| VG 95218 Part 60–61 (this page) | MGSGO, MGGO, LMGSGO | 550–1,200 V AC; unscreened or Cu braid | Naval vessel main power, auxiliary lighting & control trunks |
| VG 95218 Part 62–66 (this page) | FMGSGO to LFMSGSSGO | 250 V AC; single, ind. or double Cu braid | Naval radar, sonar, radio & high-EMC combat telemetry |
| VG 95218-28 Lightweight | L-series thin-wall | Low-voltage weight-critical circuits | Weight-sensitive naval deckhouses & retrofits |
| DIN 89158 MGCG / MGCH | Commercial HEPR/SE1/SHF1 | 0.6/1 kV & 250 V; 90% Cu braid | Commercial merchant fleets, ferries & dredgers |
Always specify the exact VG 95218 Part number and Dash No. (e.g. VG 95218-60 B047) to lock conductor stranding, OD tolerance and core color scheme.
VG 95218 Part 60–66 Naval Cable RFQ Checklist
- Exact VG 95218 Part (Part 60, 61, 62, 63, 64, 65 or 66) and Dash No. (e.g. A009, B047, C001, A023).
- Conductor stranding preference (Class 2 standard vs Class 5 flexible dash numbers) and core numbering (black vs white numbered on Part 61).
- Required reel lengths per item (MOQ 50 m) and any project-specific drum marking or bulkhead gland OD tolerances.
- Requested factory routine test dossier or third-party witnessed inspection scope (lead time 7 to 45 working days).
Related selection resources
- Pair with VG 95218-28 Lightweight Naval Shipboard Cables
- Pair with VG 95218 Naval Data, Bus, Coax & Hook-Up Cables
- Compare Commercial DIN 89158 MGCG & MGCH Marine Cables
- Compare IEC 60092-353 M2XH / M2XCH Shipboard Power Cables
- Browse Complete Marine & Offshore Cable Catalog
- Explore Marine & Naval Designation Solutions Hub
VG 95218 Part 60–66 MGSGO & FMGSGO Naval Cable FAQ
How are VG 95218 Part 60 through Part 66 cables divided by function?
Part 60 (MGSGO/MGGO) covers 660–1,200 V AC main power, Part 61 (LMGSGO) covers 550 V AC lightweight power/control, Parts 62–63 (FMGSGO/FMSGSGO) cover 0.75 mm² 250 V telecom pairs, and Parts 64–66 (LFMGSSGO/LFMSGSGO/LFMSGSSGO) cover 0.4 mm² lightweight high-EMC pairs and triples.
What is the difference between MGSGO and MGGO under VG 95218 Part 60?
MGSGO (Types A, B and D) incorporates a bare copper wire braiding EMC screen beneath the halogen-free elastomeric outer sheath, whereas MGGO (Type C, single-core 1×25 to 1×300 mm²) is unscreened for high-current main bus runs.
What is the maximum operating voltage of VG 95218 Part 60 MGSGO cables?
AC 1,200 V / DC 1,800 V (3.5 kV AC routine test) for Part 60 Types A, B and C, and AC 660 V / DC 1,000 V (3.0 kV test) for Type D multi-core control builds.
Are VG 95218 Part 60–66 cables suitable for permanent underwater submersion?
No. Per VG 95218 and BV 3400, Part 60–66 elastomeric cables are engineered for fixed above- and below-deck dry/damp shipboard installation (-30 °C to +90 °C), not continuous subsea submersion.
What is the MOQ and lead time for VG 95218 Part 60–66 naval cables?
50 m minimum order per dash number, custom-manufactured to VG 95218 dimensional and electrical specifications in 7 to 45 working days.
VG 95218 Part 60–66 Dash-Number & Dimension Schedule
VG 95218 Part 60–66 Electrical, Thermal & EMC Ratings
- Complete VG 95218 Part 60–66 matrix: Power (Part 60 MGSGO/MGGO), light power (Part 61 LMGSGO) and screened/double-screened telecom pairs & triples (Parts 62–66)
- High naval voltage margin (BV 3400): Part 60 Types A/B/C rated AC 1,200 V / DC 1,800 V (3.5 kV test); Part 61 AC 550 V / DC 825 V; Parts 62–66 AC 250 V / DC 355 V
- Single & double copper-braid EMC tiers: Dense bare copper wire braiding with polyester separator foils protects naval radar, sonar and combat-management electronics
- Cross-linked zero-halogen elastomeric build: Halogen-free cross-linked polymeric insulation and elastomeric sheath designed to IEC 60332-3-24 Cat. C, IEC 60754 and IEC 61034
- Compact 4 × D / 5 × D bend & 50 m MOQ: Class 2 or flexible Class 5 copper (0.4–300 mm², -30 to +90 °C), custom-manufactured in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | AC 1,200 V / DC 1,800 V (Part 60 A/B/C), AC 660 V / DC 1,000 V (60 D), AC 550 V / DC 825 V (Part 61), AC 250 V / DC 355 V (Parts 62 to 66) |
| AC routine test voltage | 3.5 kV (Part 60 A/B/C), 3.0 kV (Part 60 D), 2.5 kV (Part 61 LMGSGO), 2.0 kV (Parts 62 to 66 telecom) |
| Operating temperature range | -30 °C to +90 °C fixed service (-15 °C minimum installation; 0 to 60 Hz continuous at 45 °C ambient) |
| Minimum bending radius | 4 × D fixed for flexible Class 5 builds; 5 × D fixed for all standard Class 2 Part 60 to 66 builds |
| Insulation and outer sheath | Halogen-free cross-linked polymeric insulation and cross-linked elastomeric outer sheath with copper braid EMC options |
| Minimum order and lead time | 50 m minimum order quantity per dash number; custom manufacturing lead time 7 to 45 working days |
VG 95218 Part 60–66 Dash-Number & Dimension Schedule
| VG 95218 Part & Model | Dash / Size (mm²) | Max Voltage (AC/DC) | EMC Screen Tier | Outer Diameter (mm) | Approx. Weight (kg/km) | Order MOQ | Next step |
|---|---|---|---|---|---|---|---|
| VG 95218-60 MGSGO 1×95 | A009 · 1×95 | 1,200 / 1,800 V | Copper Wire Braid | 19.5–20.5 | 1,210 | 50 m | Request this size |
| VG 95218-60 MGSGO 3×25 | B047 · 3×25 | 1,200 / 1,800 V | Copper Wire Braid | 24.0–25.6 | 1,455 | 50 m | Request this size |
| VG 95218-60 MGSGO 3×70 | B050 · 3×70 | 1,200 / 1,800 V | Copper Wire Braid | 34.5–36.9 | 3,260 | 50 m | Request this size |
| VG 95218-60 MGSGO 4×16 | B056 · 4×16 | 1,200 / 1,800 V | Copper Wire Braid | 22.0–23.7 | 1,235 | 50 m | Request this size |
| VG 95218-60 MGGO 1×150 | C001 · 1×150 | 1,200 / 1,800 V | Unscreened | 21.5–24.0 | 1,625 | 50 m | Request this size |
| VG 95218-60 MGSGO 19×6 | D002 · 19×6 | 660 / 1,000 V | Copper Wire Braid | 29.4–30.8 | 1,860 | 50 m | Request this size |
| VG 95218-61 LMGSGO 3×2.5 | A023 · 3×2.5 | 550 / 825 V | Copper Wire Braid | 8.0–9.4 | 170 | 50 m | Request this size |
| VG 95218-61 LMGSGO 19×1.5 | A010 · 19×1.5 | 550 / 825 V | Copper Wire Braid | 13.9–15.3 | 480 | 50 m | Request this size |
| VG 95218-62 FMGSGO 4×2×0.75 | A002 · 4P×0.75 | 250 / 355 V | Overall Cu Braid | 9.6–11.2 | 190 | 50 m | Request this size |
| VG 95218-63 FMSGSGO 7×2×0.75 | A003 · 7P×0.75 | 250 / 355 V | Ind.+Overall Cu Braid | 14.9–16.4 | 480 | 50 m | Request this size |
| VG 95218-64 LFMGSSGO 12×2×0.4 | A004 · 12P×0.4 | 250 / 355 V | Double Overall Cu Braid | 12.8–14.5 | 320 | 50 m | Request this size |
| VG 95218-65 LFMSGSGO 7×2×0.4 | A003 · 7P×0.4 | 250 / 355 V | Ind.+Overall Cu Braid | 12.0–13.7 | 320 | 50 m | Request this size |
| VG 95218-66 LFMSGSSGO 12×3×0.4 | A002 · 12T×0.4 | 250 / 355 V | Ind.+Double Cu Braid | 16.9–18.9 | 650 | 50 m | Request this size |
All VG 95218 Part 60–66 dash numbers (including flexible Class 5 variants such as A016–A020 and B062–B074, plus white-numbered vs black-numbered Part 61 cores) are manufactured to VG 95218-2/-5 dimensional and electrical criteria; factory routine test sheets accompany each shipment.
ASCII part references for BOM and ERP entry: VG95218-60-A009, VG95218-60-B047, VG95218-60-B050, VG95218-60-B056, VG95218-60-C001, VG95218-60-D002, VG95218-61-A023, VG95218-61-A010, VG95218-62-A002, VG95218-63-A003, VG95218-64-A004, VG95218-65-A003, VG95218-66-A002.
VG 95218-2/-5, BV 3400 & IEC Low-Fire-Hazard Standards
| Standard or specification | Application |
|---|---|
| VG 95218 Part 60–66, VG 95218-2/-5 & BV 3400 | German naval vessel cable construction, current-rating (45 °C ambient, 0.8 cluster factor) and test design reference. |
| IEC 60332-1-2 & IEC 60332-3-24 Cat. C | Single-cable and vertical bunched naval flame-propagation design reference. |
| IEC 60754-1/-2 & IEC 61034-1/-2 (DIN EN 50268) | Zero-halogen acid-gas toxicity and low smoke optical density design reference for enclosed naval decks. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 production quality management and routine test records
VG 95218-60 — Electric Cables for Ships: Power Cables MGSGO / MGGO
IEC 60332-3 — Vertical Flame Spread Tests for Bunched Cables
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
BFCU, BFCU(i) & BFCU(c) NEK 606 Fire-Resistant Armoured Offshore Cable (0.6/1 kV & 250 V)
A related cable option for a different application or duty profile.
View productVG 95218-28 Lightweight Naval Shipboard Cable
A related cable option for a different application or duty profile.
View productVG 95218 Naval Data, Bus, Coax & Hook-Up Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.