Submersible Pump Cables TEBAOFLEX

S05BC4B-F / S07BC4B-F / S1BC4B-F Screened Drinking-Water Pump Cable

S05BC4B-F, S07BC4B-F and S1BC4B-F are screened drinking-water pump cable families in 300/500 V, 450/750 V and 0.6/1 kV classes. Select the sheath and protective-conductor arrangement with the pump entry.

  • Plain flexible copper conductors, Class 5.
  • Tinned-copper braid with coordinated end terminations.
  • EPR insulation with model-specific EPDM or EPR sheath systems.
  • 90 °C maximum conductor temperature.

Send the motor-drive details, complete cable designation, entry drawing and drinking-water requirements for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

Screened Drinking-Water Pump Connections in Three Voltage Classes

S05BC4B-F, S07BC4B-F and S1BC4B-F are screened rubber pump cables for electrical equipment in water, including drinking-water installations. The designations identify separate 300/500 V, 450/750 V and 0.6/1 kV voltage classes, with plain Class 5 copper conductors and a tinned-copper braid.

Select the sheath system alongside the voltage class. S05BC4B-F and S07BC4B-F use EPR insulation and EPDM outer sheaths. The S1BC4B-F range uses EPR insulation and an EPR sheath system. Its configurations include single-core, G-type, KON and distributed 3G/3 arrangements, allowing the cable selection to follow the actual motor and protective-conductor connection.

  • Select the electrical profile: keep the model, rated voltage and cable-test requirements together.
  • Plan the cable entry: compare finished diameter limits, seal range and the fixed or flexible bend requirement.
  • Coordinate screening: provide effective braid contact at both cable ends and the specified protective-conductor connection.

The S1BC4B-F configuration tables combine conductor diameter, finished dimensions and reference electrical values. Match these to the pump entry, installed route and circuit design. Specify the selected configuration’s weight with the quotation. Include water composition, motor and drive details, installed length and drinking-water documentation requirements with the enquiry. Support the cable independently of the pump lifting system. Immersion depth and the permitted water-temperature limit are confirmed for the specified project.

For screened drinking-water pump selection, explore the submersible pump cable range; for S05BC4B-F, S07BC4B-F and S1BC4B-F motor-drive planning, read the VFD cable guide.

Construction

Construction

Choose the complete model and sheath system. The four-core S07BC4B-F illustration represents the selected EPR/EPDM construction. The S1BC4B-F EPR illustrations show its single-core, KON and distributed protective-conductor arrangements.

S07BC4B-F four-core cross-section with EPR insulation, EPDM inner sheath and tinned-copper braid
Representative S07BC4B-F four-core construction with the EPDM inner-sheath option.
S05BC4B-F four-core cross-section with braid directly over EPR-insulated cores
Representative S05BC4B-F four-core construction with the braid over the core assembly.
S1BC4B-F EPR 3×25+3G16/3 cross-section with three phase cores and three protective conductors
S1BC4B-F EPR 3×25+3G16/3: representative three-phase arrangement with three distributed protective conductors.
S1BC4B-F EPR 3×10/10KON three-core cross-section with an overall tinned-copper braid
S1BC4B-F EPR 3×10/10KON: representative three-core arrangement with an overall tinned-copper braid.
S1BC4B-F 1x95 single-core cross-section with plain copper, EPR insulation and tinned-copper braid
S1BC4B-F 1x95: representative single-core EPR construction with a tinned-copper braid and EPR sheath system.
Screened drinking-water cable construction profiles
ParameterValue or condition
Common conductorPlain finely stranded copper, Class 5; the screen uses tinned copper.
S05BC4B-FEPR-insulated cores, overall tinned-copper braid and EPDM outer sheath; no separate inner-sheath layer in this profile.
S07BC4B-FEPR insulation, EPDM inner sheath where selected, tinned-copper braid and EPDM outer sheath.
S1BC4B-FEPR insulation, overall tinned-copper braid and blue EPR sheath system.
Protective-conductor arrangementG configurations include a green/yellow core. Preserve the exact G, KON or distributed 3G/3 configuration marking when ordering.
Core identificationDIN EN 50525-1 for the S05BC4B-F and S07BC4B-F profiles; specify the complete motor and protective-conductor arrangement for the selected S1BC4B-F configuration.
Applications

Applications

Screened connections for drinking-water pumps, well systems and electrical equipment in water under medium mechanical stress, including converter-controlled AC drives with coordinated screen terminations.

Screened drinking-water pump cable in a supported waterworks wellhead connection
Application illustration: independently supported cable connections at a drinking-water wellhead.
Screened drinking-water pump installation selection
ParameterValue or condition
Motor and driveSelect the cable voltage and construction with the motor circuit and converter output.
Screen terminationProvide effective screen contact to ground at both ends and coordinate the protective-conductor connection separately.
Pump entryMatch the finished diameter, sealing range, braid breakout and strain relief to the exact pump-entry drawing.
Bending and supportsApply the selected material profile or row-specific bend radii; use independent supports and a separate pump lifting system.
Water chemistryExclude water with chlorine contents above 0.5 mg/l. State treatment chemicals and cleaning conditions for material selection.
Installation environmentThe selected profiles exclude explosion-hazard areas.
Drinking-water contactCoordinate cable sheath, joints, gland and entry materials with the destination’s documentation requirements.
Project water dutyConfirm immersion depth and the permitted maximum water temperature with the project enquiry.
Specifications

Specifications

Screened drinking-water pump cable selection summary
ParameterValue
Voltage classes300/500 V; 450/750 V; 0.6/1 kV
ConductorPlain flexible copper, Class 5
InsulationEPR
ScreenTinned-copper braid
Maximum conductor temperature90 °C
S05BC4B-F and S07BC4B-F — separate electrical and installation profiles
ParameterS05BC4B-FS07BC4B-F
Rated voltage U₀/U300/500 V450/750 V
Maximum AC operating voltage0.318/0.55 kV0.476/0.825 kV
Maximum DC operating voltage0.413/0.825 kV0.619/1.238 kV
AC test voltage — main cores2 kV / 15 minutes2.5 kV / 15 minutes
ConductorPlain finely stranded copper, Class 5Plain finely stranded copper, Class 5
Core insulationEPREPR
Inner sheathNo separate inner sheath in this profileEPDM where applied in the selected construction
ScreenTinned-copper braid between cores and outer sheathTinned-copper braid between inner and outer sheath
Outer sheathEPDMEPDM
Maximum conductor temperature90 °C90 °C
Short-circuit conductor temperature250 °C250 °C
Minimum ambient temperature — fixed installation−50 °C−50 °C
Minimum ambient temperature — flexible use−25 °C−25 °C
Maximum tensile load on the conductor15 N/mm²15 N/mm²
Minimum bending radius — fixed installation4 × maximum cable OD4 × maximum cable OD
Minimum bending radius — flexible use6 × maximum cable OD6 × maximum cable OD
Cross-section family limitUp to 2.5 mm²Up to 70 mm²

Select core count and conductor cross-section together. Use the selected finished dimensions for gland and seal design.

Additional S07BC4B-F connection conditions
ParameterValue or condition
Protected fixed connectionFor protected fixed installations in conduits, equipment or wells: up to 1000 V AC, or 750 V DC against earth.
Motor-test conditionS07BC4B-F motor tests: 3 kV AC for a maximum of 3 minutes. This is separate from the main-core cable test above.
S1BC4B-F 0.6/1 kV — EPR construction and installation profile
ParameterValue or condition
Rated voltage U₀/U0.6/1 kV
Highest system voltage Um1.2 kV
Cable-test voltage3 kV
ConductorPlain finely stranded copper, Class 5
Insulation / sheathEPR insulation / EPR sheath system
ScreenTinned-copper braid
Maximum conductor temperature90 °C
Short-circuit conductor temperature250 °C
Minimum ambient temperature — fixed installation−50 °C
Minimum ambient temperature — flexible use−50 °C
Maximum permanent tensile stress15 N/mm²
Minimum bending radius — fixed installation4 × maximum cable OD
Minimum bending radius — flexible use6 × maximum cable OD
Water-resistance design referenceAD8
S1BC4B-F EPR configurations — dimensions and mass
S1BC4B-F configuration (mm²)Conductor Ø (mm)Minimum OD (mm)Maximum OD (mm)Approx. mass (kg/km)
S1BC4B-F 1x9512.219.721.51130
S1BC4B-F 3X2,5/2,5KON210.512.1250
S1BC4B-F 3X4/4KON2.411.813.4304
S1BC4B-F 3X6/6KON2.913.615.2410
S1BC4B-F 3X10/10KON3.917.819.8610
S1BC4B-F 3X16/16KON520.922.9970
S1BC4B-F 3X25+3G16/36.325.328.31470
S1BC4B-F 3X35+3G16/37.528.331.32020
S1BC4B-F 3X50+3G25/38.933.236.22582
S1BC4B-F 3X70+3G35/310.738.741.73560
S1BC4B-F 3X95+3G50/312.343.747.75130
S1BC4B-F 3X120+3G70/314.348.851.86130
S1BC4B-F 3X150+3G70/31651.754.77090
S1BC4B-F 3X240+3G120/320.363.568.511220
S1BC4B-F 4G1,51.61213260
S1BC4B-F 12G2,5218.820.8On request
S1BC4B-F 7G2,5216.118.1500
S1BC4B-F EPR configurations — reference electrical values
S1BC4B-F configuration (mm²)Reference current (A)1 s short-circuit current (kA)
S1BC4B-F 1x9530113.6
S1BC4B-F 3X2,5/2,5KON300.36
S1BC4B-F 3X4/4KON410.57
S1BC4B-F 3X6/6KON530.86
S1BC4B-F 3X10/10KON741.43
S1BC4B-F 3X16/16KON992.29
S1BC4B-F 3X25+3G16/31313.58
S1BC4B-F 3X35+3G16/31625.01
S1BC4B-F 3X50+3G25/32027.15
S1BC4B-F 3X70+3G35/325010.01
S1BC4B-F 3X95+3G50/330113.6
S1BC4B-F 3X120+3G70/335217.2
S1BC4B-F 3X150+3G70/340421.5
S1BC4B-F 3X240+3G120/354534.3
S1BC4B-F 4G1,5230.21
S1BC4B-F 12G2,5300.36
S1BC4B-F 7G2,5300.36

Select current-carrying capacity for the actual loading and installation, including supported air and water sections. Use the listed short-circuit values with their 1 s duration. Weight for the selected configuration is confirmed with the quotation. Immersion depth and permitted water temperature are confirmed for the specified project.

Standards

Standards

Construction, installation and water-service references
ReferenceApplication
EN 50525-2-21Construction reference for the three model families.
DIN EN 60228 / IEC 60228Class 5 conductor reference.
DIN EN 50525-1Core identification for S05BC4B-F and S07BC4B-F.
DIN EN 50525-2-21Water-resistance reference for S05BC4B-F and S07BC4B-F.
DIN EN 50565-2General cable-use and installation guidance.
AD8Water-resistance design reference for the selected S1BC4B-F family.
Drinking-water material documentationSpecify the water-contact documentation required for the selected construction and project destination.

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.