S05BC4B-F / S07BC4B-F / S1BC4B-F Screened Drinking-Water Pump Cable
S05BC4B-F, S07BC4B-F and S1BC4B-F are screened drinking-water pump cable families in 300/500 V, 450/750 V and 0.6/1 kV classes. Select the sheath and protective-conductor arrangement with the pump entry.
- Plain flexible copper conductors, Class 5.
- Tinned-copper braid with coordinated end terminations.
- EPR insulation with model-specific EPDM or EPR sheath systems.
- 90 °C maximum conductor temperature.
Send the motor-drive details, complete cable designation, entry drawing and drinking-water requirements for a technical quotation.
Screened Drinking-Water Pump Connections in Three Voltage Classes
S05BC4B-F, S07BC4B-F and S1BC4B-F are screened rubber pump cables for electrical equipment in water, including drinking-water installations. The designations identify separate 300/500 V, 450/750 V and 0.6/1 kV voltage classes, with plain Class 5 copper conductors and a tinned-copper braid.
Select the sheath system alongside the voltage class. S05BC4B-F and S07BC4B-F use EPR insulation and EPDM outer sheaths. The S1BC4B-F range uses EPR insulation and an EPR sheath system. Its configurations include single-core, G-type, KON and distributed 3G/3 arrangements, allowing the cable selection to follow the actual motor and protective-conductor connection.
- Select the electrical profile: keep the model, rated voltage and cable-test requirements together.
- Plan the cable entry: compare finished diameter limits, seal range and the fixed or flexible bend requirement.
- Coordinate screening: provide effective braid contact at both cable ends and the specified protective-conductor connection.
The S1BC4B-F configuration tables combine conductor diameter, finished dimensions and reference electrical values. Match these to the pump entry, installed route and circuit design. Specify the selected configuration’s weight with the quotation. Include water composition, motor and drive details, installed length and drinking-water documentation requirements with the enquiry. Support the cable independently of the pump lifting system. Immersion depth and the permitted water-temperature limit are confirmed for the specified project.
For screened drinking-water pump selection, explore the submersible pump cable range; for S05BC4B-F, S07BC4B-F and S1BC4B-F motor-drive planning, read the VFD cable guide.
Construction
Choose the complete model and sheath system. The four-core S07BC4B-F illustration represents the selected EPR/EPDM construction. The S1BC4B-F EPR illustrations show its single-core, KON and distributed protective-conductor arrangements.





| Parameter | Value or condition |
|---|---|
| Common conductor | Plain finely stranded copper, Class 5; the screen uses tinned copper. |
| S05BC4B-F | EPR-insulated cores, overall tinned-copper braid and EPDM outer sheath; no separate inner-sheath layer in this profile. |
| S07BC4B-F | EPR insulation, EPDM inner sheath where selected, tinned-copper braid and EPDM outer sheath. |
| S1BC4B-F | EPR insulation, overall tinned-copper braid and blue EPR sheath system. |
| Protective-conductor arrangement | G configurations include a green/yellow core. Preserve the exact G, KON or distributed 3G/3 configuration marking when ordering. |
| Core identification | DIN EN 50525-1 for the S05BC4B-F and S07BC4B-F profiles; specify the complete motor and protective-conductor arrangement for the selected S1BC4B-F configuration. |
Applications
Screened connections for drinking-water pumps, well systems and electrical equipment in water under medium mechanical stress, including converter-controlled AC drives with coordinated screen terminations.

| Parameter | Value or condition |
|---|---|
| Motor and drive | Select the cable voltage and construction with the motor circuit and converter output. |
| Screen termination | Provide effective screen contact to ground at both ends and coordinate the protective-conductor connection separately. |
| Pump entry | Match the finished diameter, sealing range, braid breakout and strain relief to the exact pump-entry drawing. |
| Bending and supports | Apply the selected material profile or row-specific bend radii; use independent supports and a separate pump lifting system. |
| Water chemistry | Exclude water with chlorine contents above 0.5 mg/l. State treatment chemicals and cleaning conditions for material selection. |
| Installation environment | The selected profiles exclude explosion-hazard areas. |
| Drinking-water contact | Coordinate cable sheath, joints, gland and entry materials with the destination’s documentation requirements. |
| Project water duty | Confirm immersion depth and the permitted maximum water temperature with the project enquiry. |
Specifications
| Parameter | Value |
|---|---|
| Voltage classes | 300/500 V; 450/750 V; 0.6/1 kV |
| Conductor | Plain flexible copper, Class 5 |
| Insulation | EPR |
| Screen | Tinned-copper braid |
| Maximum conductor temperature | 90 °C |
| Parameter | S05BC4B-F | S07BC4B-F |
|---|---|---|
| Rated voltage U₀/U | 300/500 V | 450/750 V |
| Maximum AC operating voltage | 0.318/0.55 kV | 0.476/0.825 kV |
| Maximum DC operating voltage | 0.413/0.825 kV | 0.619/1.238 kV |
| AC test voltage — main cores | 2 kV / 15 minutes | 2.5 kV / 15 minutes |
| Conductor | Plain finely stranded copper, Class 5 | Plain finely stranded copper, Class 5 |
| Core insulation | EPR | EPR |
| Inner sheath | No separate inner sheath in this profile | EPDM where applied in the selected construction |
| Screen | Tinned-copper braid between cores and outer sheath | Tinned-copper braid between inner and outer sheath |
| Outer sheath | EPDM | EPDM |
| Maximum conductor temperature | 90 °C | 90 °C |
| Short-circuit conductor temperature | 250 °C | 250 °C |
| Minimum ambient temperature — fixed installation | −50 °C | −50 °C |
| Minimum ambient temperature — flexible use | −25 °C | −25 °C |
| Maximum tensile load on the conductor | 15 N/mm² | 15 N/mm² |
| Minimum bending radius — fixed installation | 4 × maximum cable OD | 4 × maximum cable OD |
| Minimum bending radius — flexible use | 6 × maximum cable OD | 6 × maximum cable OD |
| Cross-section family limit | Up to 2.5 mm² | Up to 70 mm² |
Select core count and conductor cross-section together. Use the selected finished dimensions for gland and seal design.
| Parameter | Value or condition |
|---|---|
| Protected fixed connection | For protected fixed installations in conduits, equipment or wells: up to 1000 V AC, or 750 V DC against earth. |
| Motor-test condition | S07BC4B-F motor tests: 3 kV AC for a maximum of 3 minutes. This is separate from the main-core cable test above. |
| Parameter | Value or condition |
|---|---|
| Rated voltage U₀/U | 0.6/1 kV |
| Highest system voltage Um | 1.2 kV |
| Cable-test voltage | 3 kV |
| Conductor | Plain finely stranded copper, Class 5 |
| Insulation / sheath | EPR insulation / EPR sheath system |
| Screen | Tinned-copper braid |
| Maximum conductor temperature | 90 °C |
| Short-circuit conductor temperature | 250 °C |
| Minimum ambient temperature — fixed installation | −50 °C |
| Minimum ambient temperature — flexible use | −50 °C |
| Maximum permanent tensile stress | 15 N/mm² |
| Minimum bending radius — fixed installation | 4 × maximum cable OD |
| Minimum bending radius — flexible use | 6 × maximum cable OD |
| Water-resistance design reference | AD8 |
| S1BC4B-F configuration (mm²) | Conductor Ø (mm) | Minimum OD (mm) | Maximum OD (mm) | Approx. mass (kg/km) |
|---|---|---|---|---|
| S1BC4B-F 1x95 | 12.2 | 19.7 | 21.5 | 1130 |
| S1BC4B-F 3X2,5/2,5KON | 2 | 10.5 | 12.1 | 250 |
| S1BC4B-F 3X4/4KON | 2.4 | 11.8 | 13.4 | 304 |
| S1BC4B-F 3X6/6KON | 2.9 | 13.6 | 15.2 | 410 |
| S1BC4B-F 3X10/10KON | 3.9 | 17.8 | 19.8 | 610 |
| S1BC4B-F 3X16/16KON | 5 | 20.9 | 22.9 | 970 |
| S1BC4B-F 3X25+3G16/3 | 6.3 | 25.3 | 28.3 | 1470 |
| S1BC4B-F 3X35+3G16/3 | 7.5 | 28.3 | 31.3 | 2020 |
| S1BC4B-F 3X50+3G25/3 | 8.9 | 33.2 | 36.2 | 2582 |
| S1BC4B-F 3X70+3G35/3 | 10.7 | 38.7 | 41.7 | 3560 |
| S1BC4B-F 3X95+3G50/3 | 12.3 | 43.7 | 47.7 | 5130 |
| S1BC4B-F 3X120+3G70/3 | 14.3 | 48.8 | 51.8 | 6130 |
| S1BC4B-F 3X150+3G70/3 | 16 | 51.7 | 54.7 | 7090 |
| S1BC4B-F 3X240+3G120/3 | 20.3 | 63.5 | 68.5 | 11220 |
| S1BC4B-F 4G1,5 | 1.6 | 12 | 13 | 260 |
| S1BC4B-F 12G2,5 | 2 | 18.8 | 20.8 | On request |
| S1BC4B-F 7G2,5 | 2 | 16.1 | 18.1 | 500 |
| S1BC4B-F configuration (mm²) | Reference current (A) | 1 s short-circuit current (kA) |
|---|---|---|
| S1BC4B-F 1x95 | 301 | 13.6 |
| S1BC4B-F 3X2,5/2,5KON | 30 | 0.36 |
| S1BC4B-F 3X4/4KON | 41 | 0.57 |
| S1BC4B-F 3X6/6KON | 53 | 0.86 |
| S1BC4B-F 3X10/10KON | 74 | 1.43 |
| S1BC4B-F 3X16/16KON | 99 | 2.29 |
| S1BC4B-F 3X25+3G16/3 | 131 | 3.58 |
| S1BC4B-F 3X35+3G16/3 | 162 | 5.01 |
| S1BC4B-F 3X50+3G25/3 | 202 | 7.15 |
| S1BC4B-F 3X70+3G35/3 | 250 | 10.01 |
| S1BC4B-F 3X95+3G50/3 | 301 | 13.6 |
| S1BC4B-F 3X120+3G70/3 | 352 | 17.2 |
| S1BC4B-F 3X150+3G70/3 | 404 | 21.5 |
| S1BC4B-F 3X240+3G120/3 | 545 | 34.3 |
| S1BC4B-F 4G1,5 | 23 | 0.21 |
| S1BC4B-F 12G2,5 | 30 | 0.36 |
| S1BC4B-F 7G2,5 | 30 | 0.36 |
Select current-carrying capacity for the actual loading and installation, including supported air and water sections. Use the listed short-circuit values with their 1 s duration. Weight for the selected configuration is confirmed with the quotation. Immersion depth and permitted water temperature are confirmed for the specified project.
Standards
| Reference | Application |
|---|---|
| EN 50525-2-21 | Construction reference for the three model families. |
| DIN EN 60228 / IEC 60228 | Class 5 conductor reference. |
| DIN EN 50525-1 | Core identification for S05BC4B-F and S07BC4B-F. |
| DIN EN 50525-2-21 | Water-resistance reference for S05BC4B-F and S07BC4B-F. |
| DIN EN 50565-2 | General cable-use and installation guidance. |
| AD8 | Water-resistance design reference for the selected S1BC4B-F family. |
| Drinking-water material documentation | Specify the water-contact documentation required for the selected construction and project destination. |
For conductor classes, see the IEC 60228 standard scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
S07BB-F / S1BB-F Round Drinking Water Pump Cable
A related cable option for a different application or duty profile.
View productS1BC4N8-F 0.6/1 kV Screened Wastewater Pump Cable
A related cable option for a different application or duty profile.
View productSUBCAB Cable for Submersible Pump Motors with Control Cores
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.