SANS 1520-1 & SANS 1520-2 Flexible Rubber & TPU Mining Trailing and Reeling Cable (640/1100 V to 19/33 kV)
SANS 1520-1 & SANS 1520-2 Flexible Mining Trailing and Reeling Cable covers the Southern and Central African standard architecture from 640/1,100 V and 1.9/3.3 kV (Part 1: Type 61, Type 63, Type 64) up to 3.8/6.6 kV, 6.35/11 kV, 12.7/22 kV and 19/33 kV (Part 2: Type 611, Type 622) across 4 mm² to 240 mm². Built with Class 5 tinned copper, 90 °C EPR, composite or elastomeric screens, central pilot cradle, anti-torsion braid, and HD-PCP or EHD TPU sheathing.
SANS 1520-1 & SANS 1520-2 (formerly SABS 1520) Flexible Rubber and TPU Mining Trailing and Reeling Cable provides the dedicated metric engineering construction specified across South African gold/platinum/coal mines and the Zambian and DRC Katanga copper-cobalt belt from 640/1,100 V through 19/33 kV (4 mm² to 240 mm², O.D. 24.5 mm to 96.0 mm, +30/+40 °C ampacity 46 A to 495 A).
African underground hard-rock and mechanized coal operations rely on specific earth-leakage and pilot-continuity relay impedances that differ from North American ICEA 2-ground cables and German VDE split-earth cables. Under SANS 1520-1 (up to 1.9/3.3 kV, Types 61, 63 and 64), three IEC 60228 Class 5 tinned-copper phase cores insulated with +90 °C EPR and individually screened with tinned-copper/nylon composite braids (or conductive elastomer screens) are cabled symmetrically around a central pilot/earth-continuity core inside a profiled elastomeric cradle. Under SANS 1520-2 (3.8/6.6 kV to 19/33 kV, Types 611 and 622), triple-extruded stress-controlled EPR phases, metallic/elastomeric phase earth screens, an inner PCP sheath, an open-weave anti-torsion textile reinforcement braid, and an extra-heavy-duty HD-PCP (or tear-resistant yellow TPU) outer sheath withstand open-pit shovel dragging and mono-spiral drum reeling.
Specify SANS 1520-1 Type 63/64 for 640/1,100 V and 1.9/3.3 kV drill jumbos, LHDs, shuttle cars and continuous miners; specify SANS 1520-2 Type 611/622 for 6.6 kV, 11 kV, 22 kV and 33 kV open-pit shovels, draglines and stacker-reclaimers; or cross-check BS 6708 and AS/NZS 1802/2802 where British or Australian mine specs apply. Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days.
Explore the mining and tunneling cable range for related configurations.
SANS 1520-1 & SANS 1520-2 Mining Cable Construction
Engineered in accordance with SANS 1520-1 (up to 1.9/3.3 kV) and SANS 1520-2 (3.8/6.6 kV to 19/33 kV) construction, dimensional and routine dielectric test specifications.

| Component | Material and construction |
|---|---|
| 1. Flexible Tinned Copper Conductors (IEC 60228 Class 5) | Fine-stranded annealed tinned copper conductors (4 mm² to 240 mm²) offering high flex-fatigue life and sulfide/moisture corrosion resistance. |
| 2. Conductor Screen & 90 °C EPR Insulation | Semiconductive conductor stress-control layer (mandatory on 1.9/3.3 kV and Part 2 MV) plus ozone- and thermal-aging-resistant +90 °C EPR dielectric. |
| 3. Individual Phase Earth / Fault Screens | Composite tinned-copper wire and nylon cord braid screen (or semiconductive elastomer screen per SANS Type code) providing collective earth-fault capacity. |
| 4. Central Pilot Core & Elastomeric Cradle | Central flexible tinned-copper earth-continuity pilot conductor cushioned inside a shaped semiconductive or insulating rubber center cradle. |
| 5. Inner Sheath, Anti-Torsion Mesh & HD-PCP / TPU Outer Sheath | Vulcanized inner elastomer bedding + cross-helical synthetic anti-torsion braid + heavy-duty black or yellow polychloroprene (HD-PCP / CSP) or EHD TPU outer sheath. |
SANS 1520 Type 61/63/64 & Type 611/622 Code Breakdown
- SANS 1520-1 (640/1100 V & 1.9/3.3 kV): Part 1 specification covering low-voltage and 3.3 kV underground coal-cutter, drill jumbo, shuttle-car and LHD flexible trailing cables
- Type 61 / Type 63 / Type 64: SANS 1520-1 multi-core trailing constructions featuring three screened power phases laid around a central pilot/earth-continuity core
- SANS 1520-2 (3.8/6.6 kV to 19/33 kV): Part 2 specification covering medium-voltage heavy-duty trailing and reeling cables for open-pit excavators, drills and stacker-reclaimers
- Type 611 / Type 622: SANS 1520-2 3-phase screened medium-voltage flexible trailing and reeling constructions with anti-torsion reinforcement
- HD-PCP / EHD TPU Sheathing: Heavy-duty vulcanized polychloroprene rubber or optional high-visibility yellow ether-based TPU for laterite, quartzite and wet rock benches
SANS 1520 African Copperbelt, Gold & Coal Mining Applications
Built for mobile underground and surface mining equipment across Southern, Central and West African hard-rock and coal operations.

- Underground copper-cobalt, gold and platinum drill jumbos, roof bolters, load-haul-dump (LHD) loaders and submersible face pumps (640/1,100 V & 1,000 V).
- Mechanized underground coal continuous miners, longwall shearers and shuttle cars operating on 1,000 V and 1.9/3.3 kV flameproof gate-end boxes.
- Open-pit 6.6 kV, 11 kV and 22 kV electric rope shovels, hydraulic face excavators, rotary blast-hole drills and mobile in-pit crushing rigs.
- Stockyard bucket-wheel stacker-reclaimers, rail-mounted ship loaders and overland conveyor take-up reels operating up to 19/33 kV.
- Export drum supply (MOQ 50 m, 7 to 45 working days) proven across DRC, Zambian and Southern African mining logistics corridors.
SANS 1520 vs. BS 6708, AS/NZS 1802/2802 & DIN VDE 0250 Matrix
| Standard Family | Typical Voltage Tiers | Earth / Pilot Architecture | Primary Mining Region |
|---|---|---|---|
| SANS 1520-1 / -2 (this page) | 640/1100 V, 3.3, 6.6, 11, 22, 33 kV | 3 phase screens + central pilot core | South Africa, Zambia, DRC, Zimbabwe, Botswana, Namibia |
| BS 6708 (Type 7/62/63/321/830) | 640/1100 V & 1.9/3.3 kV | Collective/individual screens + pilot | UK, West Africa & Commonwealth underground coal/hard-rock |
| AS/NZS 1802 & 2802 (Type 241/441) | 1.1/1.1 kV to 33/33 kV | 3 interstitial earths + central pilot (241) or semiconductive (275) | Australia, Papua New Guinea, Indonesia |
| DIN VDE 0250-813 ((N)TSCGEWÖU) | 3.6/6 kV to 18/30 kV | 3 split interstitial earth cores (no pilot unless -FO/ctrl) | Europe, Turkey, CIS, global stacker-reclaimers & TBMs |
Check gate-end box coupler gland bore and pilot-earth diode relay specification before substituting VDE (N)TSCGEWÖU or ICEA SHD-GC on SANS 1520 mine sites.
SANS 1520 Mining Trailing & Reeling Cable RFQ Checklist
- SANS part, type number and rated voltage: SANS 1520-1 (640/1100 V or 1.9/3.3 kV, Type 61/63/64) or SANS 1520-2 (6.6, 11, 22 or 33 kV, Type 611/622).
- Phase conductor cross-section (4 mm² to 240 mm²) and screen style (metallic copper/nylon composite braid vs. conductive elastomer screen).
- Outer sheath material and color: heavy-duty vulcanized black/yellow polychloroprene (HD-PCP/CSP) or extra-heavy-duty yellow polyurethane (TPU).
- Mechanical duty: open-pit shovel ground trailing, underground jumbo reeling, or high-speed mono-spiral stacker-reclaimer drum.
- Drum cut length, total meterage and destination port/inland corridor (MOQ 50 m; lead time 7 to 45 working days).
Related selection resources
- Mining & Tunneling Cables Full Catalog
- TPU vs. CPE Mining Trailing Cable Jacket Selection Guide
- Global Mining Cable Designation Cross-Reference (ICEA, VDE, BS, AS/NZS, SANS)
- BS 6708 Mining Cable Types & Replacement Guide
- AS/NZS 1802 & 2802 Mining Cable Selection Guide
SANS 1520-1 & SANS 1520-2 Mining Cable FAQ
What is the difference between SANS 1520-1 and SANS 1520-2 mining cables?
1.9/3.3 kV is the voltage boundary: SANS 1520-1 covers low-voltage 640/1,100 V and 1.9/3.3 kV underground trailing cables (such as Types 61, 63 and 64), while SANS 1520-2 governs 3.8/6.6 kV through 19/33 kV medium-voltage trailing and reeling cables (Types 611 and 622).
Can SANS 1520 cables be ordered with an extra-heavy-duty yellow TPU outer sheath for Copperbelt open-pit mines?
Yes. Alongside traditional vulcanized heavy-duty polychloroprene (HD-PCP), TEBAOFLEX manufactures SANS 1520-1 and SANS 1520-2 cables with high-visibility yellow ether-based TPU outer sheaths to resist sharp laterite/quartzite rock cutting and wet mud hydrolysis.
Does TEBAOFLEX have export experience supplying mining cables into Zambia and the DRC?
Yes. As documented in our company profile, TEBAOFLEX exports mining trailing and reeling cables into more than 20 countries and regions, including copper, cobalt and coal mining operations in the DRC and Zambia.
Does this SANS 1520 series carry third-party SABS permit markings?
No. Our cables are engineered and routine-tested to SANS 1520-1 and SANS 1520-2 dimensional, conductor-resistance and high-voltage withstand specifications; SABS mark certification is not claimed.
What is the minimum order quantity and production lead time for SANS 1520 trailing cables?
50 m per size and voltage rating is our minimum order quantity, delivered on heavy export drums with a manufacturing lead time of 7 to 45 working days.
SANS 1520-1 & SANS 1520-2 Dimensional & Ampacity Schedules
SANS 1520 Key Engineering Highlights
- Complete SANS 1520-1 & SANS 1520-2 coverage: Spans Part 1 underground 640/1,100 V & 1.9/3.3 kV face equipment (Type 61/63/64) and Part 2 surface/reeling 3.8/6.6 kV to 19/33 kV excavators (Type 611/622)
- Central earth-continuity pilot & cradle: Resilient semiconductive or EPR-insulated central pilot core absorbs radial rock-crush forces and trips earth-leakage/continuity relays before phase damage
- Composite copper/nylon or conductive-rubber screens: Individual phase screens (tinned-copper/polyamide braid or semiconductive elastomer) match South African, Zambian and DRC earth-fault protection relays
- HD-PCP polychloroprene or EHD TPU outer sheath: Cross-braided polyester anti-torsion mesh embedded between inner elastomer bedding and high-visibility yellow or black HD-PCP / polyurethane outer sheath
- Proven African Copperbelt export supply: Manufactured from 50 m minimum order quantity per cross-section (lead time 7 to 45 working days) on fumigated export wooden or steel-wood drums
| Parameter | Value |
|---|---|
| Rated voltage | SANS 1520-1: 640/1100 V and 1.9/3.3 kV; SANS 1520-2: 3.8/6.6 kV, 6.35/11 kV, 12.7/22 kV and 19/33 kV |
| Operating temperature range | -25 °C (-40 °C with TPU sheath) up to +90 °C continuous conductor temperature (+250 °C short-circuit rating) |
| Conductor and screen build | 3 × IEC 60228 Class 5 tinned copper phases (4 to 240 mm²) with composite copper/textile or conductive-elastomer screens + central pilot |
| Inner and outer sheathing | Double-sheathed vulcanized HD-PCP / CSP elastomer with embedded anti-torsion textile braid (or optional high-visibility EHD TPU) |
| Minimum bending radius | 6 × overall cable diameter for free trailing service; 10 × overall diameter for motorized mono-spiral or level-wind reeling |
| Standards and flame reference | Engineered to SANS 1520-1, SANS 1520-2, IEC 60228 and IEC 60332-1-2 flame-propagation criteria; SABS mark approval is not claimed |
| Minimum order and lead time | 50 m minimum order quantity per cross-section and voltage class; manufacturing lead time 7 to 45 working days |
SANS 1520-1 (640/1,100 V & 1.9/3.3 kV) Underground Trailing & Reeling Schedule
| Model & Configuration | Voltage Class | EPR Wall (mm) | Pilot Core (mm²) | Nominal OD (mm) | Approx. Weight (kg/km) | In-Air Ampacity (A) | MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| SANS 1520-1 Type 63 3×10+P | 640/1100 V | 1.5 | 1×6 | 28.5 | 1240 | 73 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×16+P | 640/1100 V | 1.5 | 1×10 | 31.8 | 1620 | 96 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×25+P | 640/1100 V | 1.6 | 1×10 | 35.6 | 2180 | 127 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×35+P | 640/1100 V | 1.6 | 1×16 | 39.2 | 2790 | 156 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×50+P | 640/1100 V | 1.8 | 1×16 | 44.0 | 3650 | 193 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×70+P | 640/1100 V | 1.8 | 1×16 | 48.8 | 4720 | 240 | 50 m | Request this size |
| SANS 1520-1 Type 63 3×95+P | 640/1100 V | 2.0 | 1×25 | 54.5 | 6140 | 290 | 50 m | Request this size |
| SANS 1520-1 Type 64 3×35+P | 1.9/3.3 kV | 2.4 | 1×16 | 44.2 | 3280 | 158 | 50 m | Request this size |
| SANS 1520-1 Type 64 3×70+P | 1.9/3.3 kV | 2.4 | 1×16 | 53.6 | 5290 | 242 | 50 m | Request this size |
| SANS 1520-1 Type 64 3×120+P | 1.9/3.3 kV | 2.4 | 1×25 | 64.2 | 8180 | 338 | 50 m | Request this size |
SANS 1520-2 (6.6 kV, 11 kV & 22 kV) Open-Pit Excavator & Reeling Schedule
| Model & Configuration | Voltage Class | EPR Wall (mm) | Pilot Core (mm²) | Nominal OD (mm) | Approx. Weight (kg/km) | In-Air Ampacity (A) | MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| SANS 1520-2 Type 611 3×25+P | 3.8/6.6 kV | 3.0 | 1×16 | 48.0 | 3560 | 131 | 50 m | Request this size |
| SANS 1520-2 Type 611 3×35+P | 3.8/6.6 kV | 3.0 | 1×16 | 51.5 | 4240 | 162 | 50 m | Request this size |
| SANS 1520-2 Type 611 3×50+P | 3.8/6.6 kV | 3.0 | 1×16 | 55.8 | 5180 | 198 | 50 m | Request this size |
| SANS 1520-2 Type 611 3×70+P | 3.8/6.6 kV | 3.0 | 1×16 | 60.5 | 6390 | 247 | 50 m | Request this size |
| SANS 1520-2 Type 611 3×95+P | 3.8/6.6 kV | 3.0 | 1×25 | 66.0 | 7920 | 298 | 50 m | Request this size |
| SANS 1520-2 Type 611 3×120+P | 3.8/6.6 kV | 3.0 | 1×25 | 70.8 | 9360 | 346 | 50 m | Request this size |
| SANS 1520-2 Type 622 3×35+P | 6.35/11 kV | 3.8 | 1×16 | 56.2 | 4890 | 164 | 50 m | Request this size |
| SANS 1520-2 Type 622 3×70+P | 6.35/11 kV | 3.8 | 1×16 | 65.4 | 7120 | 250 | 50 m | Request this size |
| SANS 1520-2 Type 622 3×120+P | 6.35/11 kV | 3.8 | 1×25 | 75.6 | 10180 | 350 | 50 m | Request this size |
| SANS 1520-2 Type 622 3×95+P | 12.7/22 kV | 6.0 | 1×25 | 82.4 | 10650 | 302 | 50 m | Request this size |
Reference ampacities assume single cable uncoiled in free air at +30 °C ambient (+90 °C conductor) per SANS 1520; apply ambient correction (e.g., 0.91 at +40 °C) and drum-layer derating for reeling service, and final values are confirmed on the quotation drawing.
19/33 kV SANS 1520-2 builds and integrated single-mode / multimode optical-fiber composite variants are engineered to project specifications.
ASCII part references for BOM and ERP entry: TF-MIN-SANS1520, SANS1520-1-T63-3X35, SANS1520-1-T63-3X70, SANS1520-1-T64-3X70, SANS1520-2-T611-3X50, SANS1520-2-T611-3X95, SANS1520-2-T622-3X70, SANS1520-2-T622-3X120.
SANS 1520 Standards & Routine Test References
| Standard or specification | Application |
|---|---|
| SANS 1520-1 & SANS 1520-2 | South African National Standard construction, dimensional, screen-conductance and test reference for flexible rubber trailing cables (SABS mark not claimed). |
| IEC 60228 Class 5 | Flexible annealed tinned-copper conductor stranding and maximum 20 °C DC resistance specification. |
| IEC 60502-1 / IEC 60502-2 | Supplementary EPR dielectric physical aging, partial-discharge and high-voltage AC routine test reference. |
| IEC 60332-1-2 & ISO 4649 | Single-cable vertical flame-retardance and elastomer abrasion-loss test methods. |
SABS Standards Catalog — SANS 1520-1 & SANS 1520-2 Flexible Trailing Cables
IEC 60228 Conductors of Insulated Cables (Class 5 Stranding Reference)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
SHD-GC LED 2 kV–25 kV High-Visibility Transparent-TPU Helical LED Strip Mining Trailing Cable
A related cable option for a different application or duty profile.
View productType SHD-CGC 5 kV (2 kV–15 kV Range) Center-Ground-Check Shielded Portable Mining Power Cable
A related cable option for a different application or duty profile.
View productBS 6708 Type 830 6.35/11 kV High-Voltage Mining Trailing Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.