High Temperature Cables TEBAOFLEX

SiFF Class 6 Extra-Flexible, SiD Solid & SiZ Twin Silicone Wire (300/500 V, 180 °C)

SiFF extra-flexible Class 6, SiD solid Class 1 and SiZ / SiFv twin-core silicone hook-up wires (300/500 V, -60 °C to +180 °C continuous, +200 °C short-time) combine IEC 60228 tinned copper conductors (0.14 mm² to 10 mm²) with halogen-free silicone rubber insulation for ultra-tight 5x/7.5x OD cabinet bends, moving thermal probes and form-holding equipment jumpers.

Product information
SKU
TF-SIFF-SID-SIZ
Brand
TEBAOFLEX
Product overview

SiFF Class 6 extra-flexible, SiD Class 1 solid and SiZ / SiFv twin silicone hook-up wires cover specialized 300/500 V conductor geometries that standard Class 5 SiF cannot serve—spanning 1.35 mm to 6.8 mm outer diameter on single cores (0.14 to 10 mm², expandable to 25 mm²) and 2.1×4.2 mm to 10.4 mm on twin-core sensor and heater leads (-60 °C to +180 °C).

Where standard Class 5 silicone wire experiences work-hardening on hinged heated doors, oscillating hot-runner nozzles or densely packed power electronics, SiFF uses IEC 60228 Class 6 superfine tinned copper strands for a 5x OD fixed and 7.5x OD flexing bend radius without kinking. Conversely, SiD provides a single solid tinned copper wire (0.25 to 6 mm²) that holds neat 90-degree bends and plugs directly into spring-cage PCB/thermostat blocks without ferrules, while SiFv (twisted pair) and SiZ (dividable figure-8 zip twin) streamline two-wire RTD, thermocouple-compensating or 24 V/230 V heater hook-ups.

Specify SiFF for high-flex moving thermal probes and tight-radius electronics, SiD for rigid internal luminaire/control-board jumpers, and SiFv or SiZ for two-core 180 °C connections; choose standard Class 5 SiF for general 0.25 to 150 mm² cabinet wiring (300 m / 500 m standard spools on fine gauges, MOQ 50 m on >= 10 mm² power leads, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

SiFF, SiD, SiFv & SiZ 180 °C Silicone Wire Construction

All four members of the TEBAOFLEX SiFF / SiD / SiFv / SiZ family use corrosion-resistant tinned copper and high-purity halogen-free silicone rubber tailored to the mechanical flex or rigidity demand of the circuit.

Clean 2D engineering cross-section of SiFF Class 6 extra-flexible 180 C silicone wire showing dense superfine tinned copper micro-strands and concentric halogen-free silicone insulation
SiFF cross-section: high-strand-count IEC 60228 Class 6 tinned copper core engineered for 5x fixed / 7.5x flexing bend radius.
SiFF Class 6 Extra-Flexible, SiD Solid & SiZ Twin Silicone Wire (300/500 V, 180 °C) construction
ComponentMaterial and construction
1A. SiFF Superfine Tinned Copper Conductor (IEC 60228 Class 6)Extra-flexible fine-wire tinned copper stranding (0.14 mm² to 10 mm², plus 16 and 25 mm² on request) engineered for minimal restoring force and repeated flexing without tensile load.
1B. SiD Solid Tinned Copper Conductor (IEC 60228 Class 1)Single solid annealed tinned copper conductor (0.25 mm² to 6 mm²) holding formed routing shapes inside luminaires, switchgear and heating appliances.
2. Halogen-Free Silicone Rubber Core InsulationOzone-, oil-, acid/alkali-splash- and cold-resistant silicone elastomer (-60 °C to +180 °C continuous, +200 °C short-term) with >= 2.0 GOhm*km insulation resistance.
3. Twin-Core Configurations (SiFv Twisted & SiZ Parallel Zip)SiFv twists two colour-coded Class 5 silicone cores (red + white, 2x0.25 to 2x6 mm²) for magnetic noise cancellation; SiZ extrudes two Class 6 conductors in a flat dividable figure-8 web (2x0.5 and 2x0.75 mm²).

SiFF, SiD, SiFv & SiZ VDE Designation Code Breakdown

  • Si: Heat- and cold-resistant halogen-free cross-linked silicone rubber insulation (-60 °C to +180 °C, 300/500 V)
  • FF (in SiFF): Feinstdraehtig — extra-flexible superfine tinned copper stranding per IEC 60228 Class 6
  • D (in SiD): Draht — single solid tinned copper conductor per IEC 60228 Class 1 (0.25 to 6 mm²)
  • Fv (in SiFv): Two flexible Class 5 silicone-insulated cores twisted together for two-wire sensor/heater runs
  • Z (in SiZ): Zwillingsleitung — two Class 6 silicone cores extruded in a flat parallel dividable zip profile
Applications

SiFF Extra-Flexible & SiD Solid Silicone Wire Applications

Select the exact conductor stranding class across laboratory instruments, plastics hot-runners, semiconductor chambers, commercial ovens and lighting gear.

Precision thermal test chamber and heated platen sensor assembly wired with ultra-flexible blue and red SiFF Class 6 silicone hook-up wires around tight-radius brackets
Articulated heated platen and thermal probe wiring using kink-free SiFF Class 6 extra-flexible silicone leads.
  • Oscillating heated platens, packaging impulse-sealing jaws, 3D printer / hot-runner heads and articulated oven doors (SiFF Class 6).
  • Precision test probes, battery cycler leads, power-electronics bus sensors and ultra-compact thermal chambers down to 0.14 mm² / 1.35 mm OD (SiFF).
  • Form-holding luminaire internal bridges, thermostat push-in terminals and rigid appliance control panels requiring ferrule-free termination (SiD Class 1).
  • Two-wire high-temperature sensors, bimetallic thermal cutouts, halogen low-voltage spots and compact heater feeds (SiFv twisted & SiZ zip twin).

SiFF Class 6 vs SiD Class 1 vs SiF Class 5 vs SiZ Twin Wire

SiFF (Class 6) vs SiD (Class 1) vs SiF (Class 5) vs SiZ / SiFv Twin Silicone Wire
VDE Type CodeConductor ClassMin. Bend (Fixed / Flex)Primary Engineering Use Case
SiFF Extra-Flexible (this page)IEC 60228 Class 6 tinned Cu5x OD / 7.5x ODMoving heated platens, hinged oven doors, test leads & tight cabinets
SiD Solid Core (this page)IEC 60228 Class 1 solid tinned Cu10x OD / 15x ODForm-holding internal bends & ferrule-free push-in spring terminals
SiZ & SiFv Twin (this page)Class 6 zip (SiZ) / Class 5 twisted (SiFv)5x OD / 7.5x OD2-wire thermal sensors, halogen spots & compact heater pairs
SiF Standard FlexibleIEC 60228 Class 5 tinned Cu5x OD / 7.5x OD (static routing)General-purpose fixed 180 °C internal wiring from 0.25 to 150 mm²

Upgrading from Class 5 SiF to Class 6 SiFF multiplies strand count to eliminate copper work-hardening on hinged or vibrating 180 °C equipment.

SiFF, SiD & SiZ Silicone Hook-Up Wire RFQ Ordering Checklist

  • Exact VDE type code: SiFF (Class 6 extra-flexible), SiD (Class 1 solid), SiFv (twisted 2-core) or SiZ (flat dividable 2-core).
  • Cross-section (0.14 mm² to 25 mm² single-core, or 2x0.25 to 2x6 mm² twin) and required insulation colour(s).
  • Dynamic or static installation details: hinge/probe bend radius, flexing frequency and maximum ambient temperature (-60 to +180 °C).
  • Special strand requests if needed (for example 0.05 mm / 0.07 mm ultra-limp test-lead stranding or transparent silicone).
  • Number of spools per colour (500 m spools on <= 1.5 mm², 300 m on 2.5–6 mm², MOQ 50 m on >= 10 mm²; 7 to 45 working days).

Related selection resources

SiFF, SiD, SiFv & SiZ Silicone Wire Frequently Asked Questions

What is the difference between SiFF Class 6 and standard SiF Class 5 silicone wire?

SiFF uses IEC 60228 Class 6 superfine tinned copper stranding (finer individual wire diameter and substantially higher strand count than Class 5 SiF), giving lower spring-back force and superior flex-fatigue life on hinged oven doors, moving sensor heads and tight 5x/7.5x OD electronic layouts.

When should engineers specify solid-conductor SiD instead of stranded SiF or SiFF?

Specify Class 1 solid tinned-copper SiD (0.25 to 6 mm²) when internal luminaire or control-panel jumpers must hold their bent shape in open air without cable ties, or when inserting stripped ends directly into push-in spring-cage terminals without crimping bootlace ferrules.

How do SiFv and SiZ twin-core 180 °C silicone wires differ?

SiFv twists two round colour-coded Class 5 silicone cores (red and white, 2x0.25 to 2x6 mm²) to reject electromagnetic pickup on sensor and low-voltage heater circuits, whereas SiZ extrudes two Class 6 tinned copper cores side-by-side in a flat 2.1x4.2 mm or 2.4x4.8 mm figure-8 web that zips apart cleanly at termination.

What spool minimum order quantity applies to SiFF, SiD and SiZ silicone hook-up wires?

Fine cross-sections from 0.14 mm² to 1.5 mm² are supplied on 500 m standard factory spools per colour and 2.5 mm² to 6 mm² sizes on 300 m spools, while heavy 10 mm² to 25 mm² SiFF flexible jumper cables support a 50 m minimum order length in 7 to 45 working days.

Can SiFF and SiD silicone wires be used in sub-zero -60 °C cryogenic or freezer chambers?

Yes. Unlike PVC or standard elastomers that stiffen and crack below -20 °C to -30 °C, cross-linked silicone rubber on SiFF, SiD, SiFv and SiZ remains supple from -60 °C up to +180 °C continuous (+200 °C short-term).

Specifications

SiFF, SiD, SiFv & SiZ Dimensional & Spool Specifications

SiFF & SiD Key Voltage, Stranding Class, Bend & Spool Summary

  • Three specialized VDE geometries: SiFF (IEC 60228 Class 6 ultra-fine strand, 0.14–10 mm²), SiD (Class 1 solid core, 0.25–6 mm²) and SiFv / SiZ (twisted or zip-cord twin, 2x0.25–2x6 mm²)
  • 7.5x OD flexing bend radius: Sub-0.10 mm micro-stranded tinned copper in SiFF prevents strand fatigue on articulated heated platens, hinged oven doors and compact sensor heads
  • -60 °C to +180 °C halogen-free: Cross-linked silicone insulation maintains >= 2.0 GOhm*km insulation resistance, +200 °C peak tolerance and IEC 60754-1/2 zero-halogen safety
  • 1,500 / 2,000 V AC test voltage: 300/500 V AC working rating verified at 1,500 V AC up to 1.0 mm² and 2,000 V AC above 1.0 mm² across single and twin constructions
  • Standard factory spool supply: 500 m spools on 0.14–1.5 mm² and 300 m spools on 2.5–6 mm² (100 m / 50 m reels on 10–25 mm² heavy SiFF leads) in 7 to 45 working days
SiFF Class 6 Extra-Flexible, SiD Solid & SiZ Twin Silicone Wire (300/500 V, 180 °C) technical data
ParameterValue
Rated voltage300/500 V AC (Uo/U) working voltage with 1500 V AC test up to 1.0 mm2 and 2000 V AC test above 1.0 mm2
Conductor stranding classesIEC 60228 Class 6 extra-flexible tinned copper (SiFF, SiZ), Class 1 solid tinned copper (SiD) and Class 5 twisted pair (SiFv)
Cross-section and OD envelope0.14 mm2 to 10 mm2 on SiFF (1.35 to 6.8 mm OD), 0.25 to 6 mm2 on SiD (1.7 to 4.6 mm OD) and 2x0.25 to 2x6 mm2 on SiFv/SiZ
Temperature and bend radius-60 C to +180 C continuous (+200 C short-time); 5x OD fixed / 7.5x OD flexing on SiFF, SiZ and SiFv (10x / 15x OD on solid SiD)
Spool MOQ and lead time500 m standard spools (0.14 to 1.5 mm2) and 300 m spools (2.5 to 6 mm2), or MOQ 50 m on 10 to 25 mm2 leads in 7 to 45 working days
Insulation resistance and fire testAt least 2.0 GOhm*km at +20 C; halogen-free per IEC 60754-1/2 and flame-retardant per IEC 60332-1-2
Available insulation coloursBlue, black, red, white, brown, green-yellow, yellow, violet, red-brown and transparent

SiFF Class 6 Extra-Flexible & SiD Class 1 Solid Single-Core Schedule

SiFF Class 6 Extra-Flexible & SiD Class 1 Solid Silicone Single-Core Wire — Dimensional & Weight Schedule
Model & Cross-SectionIEC 60228 ClassNominal OD (mm)Copper Index (kg/km)Approx. Weight (kg/km)Min. Bend Fixed | FlexStandard Spool MOQNext step
SiFF 1x0.14 mm²Class 6 Superfine1.351.43.05x | 7.5x OD500 m spoolRequest this size
SiFF 1x0.25 mm²Class 6 Superfine1.92.45.45x | 7.5x OD500 m spoolRequest this size
SiFF 1x0.5 mm²Class 6 Superfine2.24.89.05x | 7.5x OD500 m spoolRequest this size
SiFF 1x0.75 mm²Class 6 Superfine2.57.210.05x | 7.5x OD500 m spoolRequest this size
SiFF 1x1.0 mm²Class 6 Superfine2.69.615.05x | 7.5x OD500 m spoolRequest this size
SiFF 1x1.5 mm²Class 6 Superfine2.914.420.05x | 7.5x OD500 m spoolRequest this size
SiFF 1x2.5 mm²Class 6 Superfine3.524.032.05x | 7.5x OD300 m spoolRequest this size
SiFF 1x4 mm²Class 6 Superfine4.438.050.05x | 7.5x OD300 m spoolRequest this size
SiFF 1x6 mm²Class 6 Superfine5.258.072.05x | 7.5x OD300 m spoolRequest this size
SiFF 1x10 mm²Class 6 Superfine6.896.0117.05x | 7.5x OD100 m / MOQ 50 mRequest this size
SiD 1x0.25 mm²Class 1 Solid1.72.44.310x | 15x OD500 m spoolRequest this size
SiD 1x0.5 mm²Class 1 Solid2.04.89.010x | 15x OD500 m spoolRequest this size
SiD 1x0.75 mm²Class 1 Solid2.27.213.010x | 15x OD500 m spoolRequest this size
SiD 1x1.0 mm²Class 1 Solid2.39.615.010x | 15x OD500 m spoolRequest this size
SiD 1x1.5 mm²Class 1 Solid2.614.421.010x | 15x OD500 m spoolRequest this size
SiD 1x2.5 mm²Class 1 Solid3.224.034.010x | 15x OD300 m spoolRequest this size
SiD 1x4 mm²Class 1 Solid3.938.052.010x | 15x OD300 m spoolRequest this size
SiD 1x6 mm²Class 1 Solid4.658.071.010x | 15x OD300 m spoolRequest this size

SiFF Family Companion Twin Wires: SiFv Twisted Pair & SiZ Dividable Zip Schedule

SiFv Twisted-Pair & SiZ Dividable Parallel Twin Silicone Wire Schedule (300/500 V, 180 °C)
Twin Designation & SizeCore Geometry & ClassNominal OD / Profile (mm)Copper Index (kg/km)Approx. Weight (kg/km)Standard Core Colours
SiFv 2x0.25 mm²2 Twisted Cores (Class 5)3.84.811.1Red + White
SiFv 2x0.5 mm²2 Twisted Cores (Class 5)4.29.616.7Red + White
SiFv 2x0.75 mm²2 Twisted Cores (Class 5)4.814.423.3Red + White
SiFv 2x1.0 mm²2 Twisted Cores (Class 5)5.019.228.2Red + White
SiFv 2x1.5 mm²2 Twisted Cores (Class 5)5.629.038.7Red + White
SiFv 2x2.5 mm²2 Twisted Cores (Class 5)6.848.062.2Red + White
SiFv 2x4 mm²2 Twisted Cores (Class 5)8.476.898.3Red + White
SiFv 2x6 mm²2 Twisted Cores (Class 5)10.4116.0146.1Red + White
SiZ 2x0.5 mm²Flat Dividable Zip (Class 6)2.1 x 4.29.618.0Red-Brown or Black
SiZ 2x0.75 mm²Flat Dividable Zip (Class 6)2.4 x 4.814.424.0Red-Brown, Black, White or Grey

Dimensional, copper-index and linear-mass values follow DIN VDE 0250 / IEC 60228 reference schedules (including intermediate 1x0.28 mm² SiD and 16/25 mm² heavy SiFF builds on request); final values are confirmed on the quotation drawing.

Ensure natural air circulation above +100 °C ambient to prevent sealed-enclosure silicone steam reversion, and avoid routing unjacketed single-core wires under tensile load or across sharp unbushed metal edges.

Standard fine-wire sizes (0.14 to 6 mm² and twin SiZ/SiFv) ship on 300 m or 500 m factory spools per colour, whereas heavy 10 to 25 mm² SiFF jumper cables support a 50 m minimum order quantity with 7 to 45 working days production lead time.

ASCII part references for BOM and ERP entry: TF-SIFF-1X0.14; TF-SIFF-1X0.25; TF-SIFF-1X0.5; TF-SIFF-1X0.75; TF-SIFF-1X1.0; TF-SIFF-1X1.5; TF-SIFF-1X2.5; TF-SIFF-1X4; TF-SIFF-1X6; TF-SIFF-1X10; TF-SID-1X0.75; TF-SID-1X1.5; TF-SID-1X2.5; TF-SIFV-2X0.75; TF-SIFV-2X1.5; TF-SIZ-2X0.75.

Standards

SiFF & SiD IEC 60228 Conductor & VDE Silicone Standards

SiFF Class 6 Extra-Flexible, SiD Solid & SiZ Twin Silicone Wire (300/500 V, 180 °C) standards and test references
Standard or specificationApplication
IEC 60228 / DIN EN 60228 (Class 1, Class 5 & Class 6)Defines solid (SiD), flexible (SiFv) and extra-flexible superfine (SiFF, SiZ) tinned copper conductor stranding and 20 °C DC resistance.
DIN VDE 0250 & EN 50363-1Reference criteria for 300/500 V silicone rubber insulation thickness, thermal class H (+180 °C) ageing and 1.5/2.0 kV AC dielectric testing.
IEC 60754-1 & IEC 60754-2Zero halogen acid gas release and low smoke corrosivity for sensitive electronic, medical and clean-industrial enclosures.
IEC 60332-1-2Self-extinguishing vertical flame-retardance performance on single insulated wires.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and IEC 60228 resistance test reports

IEC 60228 — Conductors of insulated cables: Class 1 solid, Class 5 flexible and Class 6 extra-flexible specifications

DIN VDE 0250 — Silicone-insulated single-core and twin hook-up wires (SiD, SiF, SiFF, SiFv, SiZ)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.