Oil and Gas Cables TEBAOFLEX

TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in)

TEF tubing-encapsulated fiber-optic (downhole FIMT), TEC-2C dual-conductor and TEH hybrid electro-optical permanent downhole cables hermetically seal 2 to 12 carbon-polyimide DTS/DAS optical fibres and/or 18 to 16 AWG fluoropolymer-insulated copper gauge cores (1,000 to 1,700 V DC) inside welded-and-drawn 316L stainless steel or UNS N08825 Alloy 825 tubing (3.18 to 6.35 mm OD, 11×11 mm PVDF/FEP encapsulation, 138 to 303 MPa, -40 to 300 °C).

Product information
SKU
TF-TEF-PDHG-DOWNHOLE
Brand
TEBAOFLEX
Product overview

TEF tubing-encapsulated fiber-optic (downhole FIMT), TEC-2C dual-conductor and TEH hybrid permanent downhole monitoring cables clamp directly onto production tubing strings via cross-coupling protectors, delivering full-wellbore Distributed Temperature and Acoustic Sensing (DTS/DAS) plus 1,000 to 1,700 V DC Permanent Downhole Gauge (PDHG) power/telemetry at pressures from 138 MPa (20,000 psi) to 303 MPa (44,000 psi) and temperatures from -40 °C to 300 °C.

Permanent outside-tubing completions fail when annular H2S/CO2 gas permeates polymer jackets or casing doglegs crush unarmoured control lines during run-in. TEBAOFLEX double- and triple-tube TEF designs enclose 2 to 12 polyimide- or hermetic carbon-polyimide-coated single-mode, multimode or pure-silica-core fibres inside an inner 1.80 to 3.18 mm stainless FIMT surrounded by a cold-drawn 6.35 mm (1/4 in, 0.71 to 1.24 mm wall) 316L or UNS N08825 Alloy 825 outer tube (with an optional 1.02 mm aluminum layer blocking hydrogen 100x more effectively above 150 °C). Extruding an 11.0 x 11.0 mm square PVDF, PP or FEP/PFA jacket — or unitizing TEC + TEF alongside two 4.0 mm galvanized/316L bumper wires in an 11.0 x 24.0 mm flatpack — absorbs run-in impact and hydraulic-fracturing vibration.

Specify TEF-125 or TEF-250 for optical-only DTS/DAS completions, TEC-250-2C for redundant dual-wire PDHG and intelligent-completion valve circuits, or TEH-250 / TEH-FP-1124 when combining quartz pressure gauges and optical sensing in a single clamp pass. For single-core 1/4 in electrical gauge/power tubing see our TEC Tubing Encased Downhole Cable, or for winch-deployed logging cables see our 4SSA27 & FIMT-EO Wireline Cable (MOQ 50 m, 7 to 45 working days).

Explore the oil, gas and petrochemical cable range for related configurations.

Construction

TEF, TEC-2C & TEH Tubing-Encapsulated & Flatpack Downhole Construction

Each TEBAOFLEX permanent downhole cable is formed from longitudinal laser-welded, 100% eddy-current-tested and hydrostatic-verified 316L or UNS N08825 Alloy 825 strip drawn to precise outer diameter and wall tolerances for orbital-weld-free completion integrity.

Clean 2D engineering cross-section of 11x11 mm square PVDF-encapsulated hybrid electro-optical permanent downhole cable showing square polymer outer jacket, thick circular 6.35 mm welded Alloy 825 or 316L metal tube, two insulated 18 AWG copper gauge conductors and one inner stainless-steel FIMT optical tube housing colour-coded fibres
Cross-section of 11x11 mm square encapsulated downhole monitoring cable: outer PVDF crush jacket, 6.35 x 0.89 mm welded 316L/825 tube, dual/hybrid copper cores and inner FIMT.
TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in) construction
ComponentMaterial and construction
1A. Optical Sensing Core (TEF & Hybrid TEH Builds)Two to twelve single-mode (ITU-T G.652.D / pure-silica-core) or 50/125 µm multimode fibres with high-temperature polyimide (150–200 °C) or hermetic carbon-polyimide / metal coatings (260–300 °C), loose-buffered in hydrogen-scavenging gel inside an inner 1.80 to 3.18 mm (0.071 to 0.125 in) laser-welded 316L stainless-steel FIMT.
1B. Dual or Hybrid Copper Gauge Conductors (TEC-2C & TEH Builds)One or two solid or 7-wire stranded annealed/tinned copper (ASTM B 33) or Class 10 nickel-coated copper (ASTM B 355) conductors in 18 AWG or 16 AWG, insulated with high-dielectric ETFE, FEP or PFA fluoropolymer (rated 1,000 to 1,700 V DC, >= 2,000 MΩ·km at 500 V DC) and stabilized with high-temperature polymeric buffer tape/filler.
2. Optional Aluminum Hydrogen-Permeation Barrier (300 °C TEF-250-HT300)Seamless 1.02 mm (0.040 in) concentric aluminum barrier layer swaged between inner and outer metal tubes on > 150 °C SAGD steam and geothermal TEF builds, reducing molecular hydrogen ingress by two orders of magnitude without organic polymers.
3. Outer Pressure-Bearing 316L or Alloy 825 Metal TubeWelded-and-drawn 3.18 mm (1/8 in, 0.41–0.61 mm wall) or 6.35 mm (1/4 in, 0.71 mm / 0.028 in, 0.89 mm / 0.035 in, or 1.24 mm / 0.049 in wall) tube in 316L stainless steel (UNS S31603) for sweet wells or UNS N08825 (Alloy 825) for H2S/CO2/high-chloride sour completions.
4. Square 11x11 mm Encapsulation or Multi-Line Bumper FlatpackAbrasion- and chemical-resistant 11.0 x 11.0 mm square (or 6.35 / 11.0 mm round) outer encapsulation in PP (125 °C), PVDF (150 °C), FEP (205 °C) or PFA (260 °C), or a unitized 11.0 x 24.0 mm flatpack locking 1/4 in TEC + 1/4 in TEF between two 4.0 mm crush-bumper wires for rapid cross-coupling clamping.
TEBAOFLEX workshop macro sample photograph of precision heavy-wall metallic armoured downhole monitoring cable resting on pure white background showing multi-layer steel protection and compact internal sensing core
TEBAOFLEX real workshop sample: precision downhole metallic armour and compact multi-element sensing core verified in factory production.

TEF / TEC-2C / TEH-FP Permanent Downhole Model Code Breakdown

  • TEF / TEC-2C / TEH: Tubing-Encapsulated Fiber-optic (TEF), Dual-Conductor electrical Tubing-Encapsulated Cable (TEC-2C), or Hybrid Electro-Optical (TEH) permanent downhole monitoring line
  • 125 / 250 / FP-1124: outer pressure tube nominal diameter in 1/1000ths of an inch (0.125 in = 3.18 mm, 0.250 in = 6.35 mm) or 11.0 x 24.0 mm dual-line bumper-wire flatpack
  • DT / TT / HT300: double-tube (DT), heavy triple-tube (TT) or 300 °C all-metal concentric aluminum hydrogen-barrier (HT300) optical FIMT architecture
  • 316L / 825: cold-drawn laser-welded tube metallurgy: austenitic 316L stainless steel (UNS S31603) for sweet wells or UNS N08825 Alloy 825 for sour H2S/CO2/chloride wells
  • SQ11 (PVDF / FEP / PFA): 11.0 x 11.0 mm square polymer outer encapsulation engineered to lock into cross-coupling protectors and absorb completion run-in crush/impact
Applications

TEF & PDHG Permanent DTS/DAS, Intelligent Completion & SAGD Applications

Install TEF, TEC-2C and TEH permanent downhole cables clamped outside production tubing, casing strings or velocity strings across onshore unconventional, offshore subsea, thermal SAGD, geothermal and CCUS injection wells.

Onshore or offshore completion rig floor clamping 11x11 mm square encapsulated permanent downhole TEF and PDHG cable onto production tubing string with metallic cross-coupling protector descending through wellhead spider
Completion crew clamping square encapsulated TEF / PDHG monitoring cable across production tubing couplings during well run-in.
  • Permanent Distributed Temperature Sensing (DTS) and Distributed Acoustic Sensing (DAS) along horizontal multi-stage hydraulic fracturing, waterflood/gas-lift allocation and CCUS CO2 plume monitoring wells.
  • Dual-conductor redundant Permanent Downhole Gauge (PDHG) quartz pressure/temperature transducers and surface-controlled intelligent-completion interval control valves (ICV).
  • Single-pass hybrid electro-optical completions (TEH-250 and TEH-FP-1124 flatpack) simultaneously powering bottomhole electronic gauges and recording continuous wellbore DTS/DAS profiles.
  • 260 °C to 300 °C Steam-Assisted Gravity Drainage (SAGD) heavy-oil wells, deep HPHT sour gas completions (UNS N08825 Alloy 825) and engineered geothermal reservoirs.

TEF & Dual-Core PDHG vs Single-Core TEC vs Retrievable Wireline FIMT

Permanent TEF / Dual-Core TEC-2C / Hybrid TEH vs Single-Core TEC vs Retrievable Wireline Logging Cable
Downhole Cable FamilyDeployment MethodCore & Barrier ArchitecturePrimary Wellbore Duty
TEF / TEC-2C / TEH Flatpack (this page)Permanently clamped outside tubing string2–12F FIMT, 2C 18/16 AWG Cu or Hybrid in 316L / Alloy 825 + 11x11 mm PVDFPermanent reservoir DTS/DAS, dual-circuit PDHG & intelligent completions
Single-Conductor 1/4 in TEC CablePermanently clamped outside tubing string1 x 18 or 16 AWG Cu + ETFE/FEP in 6.35 mm 316L / Alloy 825 tubeSingle-line DC power and digital telemetry for standard bottomhole gauges
4SSA27 & FIMT-EO Wireline Logging CableRetrievable winch spooling via grease headCentral SS FIMT + optional Cu inside double contra-helical SWAShort-term intervention DTS/DAS fracture diagnostics & optical wireline runs
Sour-Service Monoconductor / HeptacableRetrievable winch spooling under well pressure1C or 7C copper inside bare preformed S75 / MP35N double wire armourLive-well cased-hole perforating, PLT & open-hole formation evaluation

Never deploy polymer-encapsulated TEF/TEC on a dynamic wireline logging winch; conversely, bare stranded wireline cables cannot provide a hermetic gas-tight barrier through permanent wellhead tubing hangers.

TEF, Dual-Core TEC & Hybrid PDHG Flatpack RFQ Ordering Checklist

  • Completion architecture: optical-only TEF (DTS/DAS), dual-conductor electrical TEC-2C (PDHG/ICV), single-tube hybrid TEH-250, or multi-line bumper-wire flatpack (TEH-FP-1124).
  • Metal tube outer diameter, wall thickness and alloy: 1/8 in (3.18 mm) or 1/4 in (6.35 x 0.71 / 0.89 / 1.24 mm) in 316L stainless steel or UNS N08825 Alloy 825 (state H2S/CO2/Cl- levels).
  • Optical fibre count/type (SM G.652.D, pure-silica-core SM or 50/125 µm MM; polyimide vs carbon-polyimide coating) and/or copper gauge count, AWG size and DC voltage.
  • Outer encapsulation geometry and polymer: bare metal tube (for wellhead feedthrough), 11.0 x 11.0 mm square PVDF (150 °C), FEP (205 °C), PFA (260 °C) or 11.0 x 24.0 mm flatpack.
  • Maximum bottomhole temperature/pressure, continuous orbital-weld-free length per reel (MOQ 50 m) and required delivery window (7 to 45 working days).

Related selection resources

TEF Tubing-Encapsulated Fiber-Optic & PDHG Cable Frequently Asked Questions

What is the difference between TEF (Tubing-Encapsulated Fiber) and TEC (Tubing-Encapsulated Conductor) downhole cables?

TEF encloses 2 to 12 hermetically protected single-mode or multimode optical fibres inside double or triple laser-welded 316L or Alloy 825 metal tubes for continuous Distributed Temperature and Acoustic Sensing (DTS/DAS), whereas TEC houses 1 or 2 fluoropolymer-insulated copper conductors (1,000 to 1,700 V DC) for Permanent Downhole Gauge (PDHG) power; hybrid TEH cables integrate both inside one 6.35 mm tube or 11x24 mm flatpack.

When is UNS N08825 (Alloy 825) required instead of 316L stainless steel for 1/4 in TEF and PDHG downhole tubing?

316L stainless steel (UNS S31603) is suited to sweet oil, water-injection and low-chloride geothermal wells below chloride stress-corrosion thresholds, whereas UNS N08825 Alloy 825 (38–46% Ni, Cr-Mo-Cu stabilized per ASTM B 704 and ISO 15156-3) is mandatory whenever H2S sour gas, CO2 carbonic acid or hot concentrated chloride brines risk pitting or sulphide stress cracking.

How do TEF downhole fiber-optic cables prevent hydrogen darkening above 150 °C to 300 °C?

Up to 150–200 °C, TEF cables combine hydrogen-scavenging gel, pure-silica-core single-mode glass and hermetic carbon-polyimide fibre coatings inside double laser-welded metal tubes; from 150 °C to 300 °C (such as SAGD steam wells), TEF-250-HT300 adds a 1.02 mm concentric aluminum barrier whose hydrogen permeability is roughly 100 times lower than stainless steel.

Why is an 11 mm x 11 mm square PVDF encapsulation preferred on TEF and PDHG tubing-clamped completions?

11.0 x 11.0 mm square PVDF encapsulation seats flat and non-rotating inside cast or stamped cross-coupling protectors across every tubing joint, absorbs run-in casing impact and frac-fluid vibration up to 150 °C, resists H2S/methane/aromatics, and strips cleanly at the wellhead using standard 11 mm square encapsulation strippers.

What are the minimum order quantity and splice-free length options for TEF and dual-core PDHG cables?

50 m minimum order quantity (MOQ), with a factory lead time of 7 to 45 working days covering both 50 to 500 m wellhead/test assemblies and continuous orbital-weld-free 3,000 to 9,000 m completion drums.

Specifications

TEF, TEC-2C & TEH Dimensional, Collapse-Pressure & Thermal Schedule

TEF & PDHG Key Tube Alloy, Pressure, Temperature & Encapsulation Summary

  • Three permanent completion families: Optical-only TEF (1/8 in & 1/4 in double/triple FIMT), dual-core electrical TEC-2C (2x18 / 2x16 AWG) and hybrid electro-optical TEH / flatpack
  • Sweet & H2S sour metallurgy: Cold-drawn laser-welded 316L stainless steel (UNS S31603, ASTM A 632) or UNS N08825 Alloy 825 (ASTM B 704, ISO 15156-3 sour service)
  • HPHT & SAGD thermal tiers: 150 °C (PVDF/PP encapsulation), 200 to 260 °C (FEP/PFA fluoropolymer) and 300 °C all-metal aluminum hydrogen-permeation barrier TEF
  • Crush-resistant completion profiles: Bare 3.18 mm (1/8 in) and 6.35 mm (1/4 in) tubing, 11.0x11.0 mm square PVDF/FEP encapsulation, or 11.0x24.0 mm bumper-wire flatpack
  • Splice-free & custom drum supply: Minimum order quantity 50 m (from test/wellhead pigtails to continuous orbital-weld-free completion spools) in 7 to 45 working days
TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in) technical data
ParameterValue
Rated voltage1,000 V DC to 1,700 V DC on TEC-2C and hybrid TEH copper gauge cores (optical-only dielectric sensing on TEF FIMT models)
Tube dimensions and metallurgy1/8 in (3.18 mm) and 1/4 in (6.35 mm, 0.028 / 0.035 / 0.049 in wall) cold-drawn 316L stainless steel or UNS N08825 Alloy 825
Encapsulation and flatpack profilesBare metal tube, 6.35 to 11.0 mm round, 11.0x11.0 mm square PVDF/PP/FEP/PFA, or 11.0x24.0 mm dual-line flatpack with 4.0 mm bumper wires
Operating pressure and temperature138 MPa (20,000 psi) working and up to 303 MPa (44,000 psi) tube collapse rating across -40 °C to 150 °C, 200 °C, 260 °C and 300 °C tiers
Minimum bend radius and supply320 mm to 450 mm dynamic installation bend radius with MOQ 50 m and 7 to 45 working days factory lead time
Optical fibre and hydrogen protection2 to 12 SM (G.652.D / pure-silica-core) or MM fibres with carbon-polyimide coating, H2-scavenging gel or aluminum barrier
Factory NDE and dielectric testing100% inline eddy-current weld inspection, hydrostatic/nitrogen pressure test, OTDR trace (1310/1550 nm) and >= 2,000 MΩ·km IR at 500 V DC

TEF, TEC-2C & TEH Permanent Downhole Cable Dimensional, Pressure & Thermal Schedule

TEF, TEC-2C & TEH Permanent Downhole Tubing-Encapsulated & Flatpack Cable — Dimensional, Pressure & Thermal Schedule
Model & Completion TypeOuter Tube Size & WallInternal Optical / Copper CoreEncapsulation ProfileTemp. Rating (°C)Working | Collapse Pressure (MPa)Weight | Min. Bend (kg/km | mm)Next step
TEF-125-DT 1/8 in Double-Tube FIMT3.18 x 0.41 mm (316L / 825)2–6 SM/MM carbon-PI fibres + H2 gelBare 3.18 mm or 6.35 mm PVDF-40 to +200138 | 145–20732–74 | 320Request this size
TEF-125-TT 1/8 in Triple-Tube FIMT3.18 x 0.61 mm (316L / 825)2–6 SM/MM carbon-PI fibres + H2 gelBare 3.18 mm or 6.35 mm PVDF-40 to +200172 | 220–30342–84 | 320Request this size
TEF-250-SQ11 1/4 in Double-Tube TEF6.35 x 0.89 mm (0.035 in WT)3.18 mm SS FIMT (2–12 SM/MM fibres)11.0 x 11.0 mm Square PVDF / PP-40 to +150138 | 190245 | 350Request this size
TEF-250-HT300 1/4 in All-Metal H2-Barrier6.35 x 0.71 mm + 1.02 mm Al2.39 mm SS FIMT (2–8 pure-silica/C-PI)Bare 6.35 mm or FEP/PFA jacket-40 to +300138 | 172144–230 | 380Request this size
TEC-250-2C18 1/4 in Dual-Core PDHG6.35 x 0.89 mm (316L / 825)2 x 18 AWG Cu (1,000 V DC, ETFE/FEP)11.0 x 11.0 mm Square PVDF-40 to +200138 | 190268 | 350Request this size
TEC-250-2C16-HT 1/4 in HPHT PDHG6.35 x 1.24 mm (0.049 in 825)2 x 16 AWG Ni-Cu (1,000 V DC, PFA)11.0 x 11.0 mm Square FEP / PFA-40 to +260172 | 240332 | 380Request this size
TEH-250-1C18-FO 1/4 in Hybrid PDHG+TEF6.35 x 0.89 mm (316L / 825)1 x 18 AWG Cu + 1.80 mm SS FIMT (2–6F)11.0 x 11.0 mm Square PVDF-40 to +150138 | 190258 | 350Request this size
TEH-FP-1124 Dual PDHG+TEF Flatpack2 x (6.35 x 0.89 mm Alloy 825)1C/2C PDHG TEC + 4–12F TEF + 2x4 mm wire11.0 x 24.0 mm PVDF / FEP Flatpack-40 to +200138 | 190625 | 450Request this size

316L vs UNS N08825 Alloy 825 Tube & Polymer Encapsulation Selection Matrix

Permanent Downhole Tube Metallurgy & Outer Polymer Encapsulation Selection Matrix
Tube / Polymer CodeMaterial & Standard BasisContinuous Temp. WindowChemical & H2S / Brine LimitPrimary Completion Environment
316L SS (UNS S31603)Cold-drawn laser-welded austenitic SS (ASTM A 632)-40 to +260 °C (tube)Sweet oil/gas, low chloride, CO2 waterfloodLand unconventional frac monitoring, geothermal & water injection
Alloy 825 (UNS N08825)Ni-Fe-Cr-Mo-Cu-Ti alloy (ASTM B 704 / ISO 15156-3)-40 to +300 °C (tube)High H2S partial pressure, hot chloride brine & acidOffshore subsea trees, deep sour gas, HPHT & CCUS injection
PP / TPV EncapsulationImpact-grade copolymer polypropylene or TPV-40 to +125 °CAqueous completion brines & moderate hydrocarbonsCost-effective shallow-to-medium land DTS/DAS & gauge wells
PVDF Square (11x11 mm)High-modulus polyvinylidene fluoride (abrasion grade)-40 to +150 °CH2S, CO2, methane, diesel, aromatics & frac sandStandard offshore/onshore Cross-Coupling Protector clamp runs
FEP / PFA EncapsulationMelt-extruded perfluorinated fluoropolymer-40 to +205 °C (FEP) / +260 °C (PFA)Extreme sour fluids, steam condensate & solventsDeep HPHT gas, SAGD thermal recovery & high-enthalpy geothermal

Pressure values distinguish continuous completion working pressure (138 to 172 MPa / 20,000 to 25,000 psi) from cold-worked metal-tube collapse pressure calculated from tube yield strength and D/t wall ratio; final pressure, orbital-weld policy and clamp spacing are confirmed on the quotation drawing.

All 11.0 x 11.0 mm square and 11.0 x 24.0 mm flatpack encapsulations are dimensioned for standard oilfield encapsulation strippers and cast/stamped cross-coupling cable protectors.

Minimum order quantity is 50 m with a manufacturing lead time of 7 to 45 working days, available from short wellhead crossover test lengths up to continuous splice-free 3,000 to 9,000 m completion reels.

ASCII part references for BOM and ERP entry: TEF-125-DT; TEF-125-TT; TEF-250-SQ11-316L; TEF-250-SQ11-825; TEF-250-HT300; TEC-250-2C18-316L; TEC-250-2C18-825; TEC-250-2C16-HT; TEH-250-1C18-FO; TEH-FP-1124; TF-TEF-PDHG-DOWNHOLE.

Standards

TEF & PDHG ASTM B 704 / A 632 Tube Metallurgy & Optical Test Standards

TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in) standards and test references
Standard or specificationApplication
ASTM B 704 / ASTM B 751 (UNS N08825 Alloy 825)Welded nickel-iron-chromium-molybdenum-copper alloy tubing specification and general NDE test requirements for sour-service downhole control and monitoring lines.
ASTM A 632 (UNS S31603 / 316L Stainless Steel)Small-diameter seamless and welded austenitic stainless-steel tubing dimensional and mechanical standard for sweet-well TEF and TEC-2C encapsulation.
ISO 15156-3 / NACE MR0175Metallurgical selection reference for cracking-resistant nickel-base Alloy 825 tubing exposed to H2S-containing production fluids.
ASTM B 33, ASTM B 355 & ITU-T G.652.DTinned and Class 10 nickel-coated copper gauge conductors plus single-mode optical transmission baseline for permanent PDHG and DTS/DAS completions.

Certifications and document support

TEBAOFLEX ISO 9001 quality management, eddy-current tube NDE, hydrostatic and OTDR test records

ISO 15156-3 — Cracking-resistant CRAs and UNS N08825 nickel-base alloys for H2S oil and gas service

ASTM B 355 — Standard specification for nickel-coated copper conductors in high-temperature downhole cores

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.