4SSA27 & FIMT-EO Armoured Fiber-Optic & Hybrid Electro-Optical Wireline Logging Cable (DTS / DAS)
4SSA27 and FIMT-EO double-armoured fiber-optic and hybrid electro-optical wireline logging cables enclose 1 to 12 pure-silica or graded-index optical fibres (with optional hermetic carbon/polyimide coating up to 300 °C) inside a laser-welded 316L stainless-steel or Alloy 825 FIMT tube plus optional 500 to 1,200 V DC copper conductors and contra-helical wire armour (3.18 to 14.30 mm OD, 8.5 to 90 kN).
4SSA27 and FIMT-EO armoured fiber-optic and hybrid electro-optical wireline logging cables deliver distortion-free distributed acoustic sensing (DAS), distributed temperature sensing (DTS) and gigabit-rate real-time tool telemetry in dynamic winch-deployed wellbores across outer diameters from 3.18 mm (1/8 in) to 14.30 mm.
Conventional copper monoconductors and heptacables throttle data rates above a few hundred kilobits per second over 5,000 m runs and cannot acquire continuous full-wellbore Raman/Brillouin temperature or Rayleigh acoustic backscatter profiles. By sealing 1 to 12 bend-insensitive single-mode (ITU-T G.657.A1 / pure-silica 1550 nm) or 50/125 µm graded-index multimode fibres inside a gel-filled laser-welded 316L stainless-steel or Alloy 825 (UNS N08825) Fibre-in-Metal-Tube (FIMT) core—either armoured directly as a low-profile optical wireline (FIMT-OW125, FIMT-OW250, 4SSA27) or cabled with 2 to 6 fluoropolymer-insulated copper power conductors (FIMT-EO32, FIMT-EO46)—operators simultaneously power active downhole gauges/imagers and interrogate the entire wellbore optically.
Select 4SSA27 (6.60 mm, 12xG.657.A1 SM, 31 kN) or FIMT-OW250 (6.35 mm, 28 kN) for dedicated winch-spooled DAS/DTS hydraulic-fracture, steam-flood, CCUS plume and geothermal profiling; specify FIMT-EO32 (8.18 mm) or 15/32 in FIMT-EO46 (11.80 mm, 6 copper + 6 fibres, 90 kN) when active downhole tools require 1,000 to 1,200 V DC surface power; or see our TEC Tubing Encased Downhole Cable for permanent tubing-clamped completions.
Explore the oil, gas and petrochemical cable range for related configurations.
4SSA27 & FIMT-EO Laser-Welded Optical Tube & Double-Armour Construction
Every 4SSA27 and FIMT-EO cable isolates fragile silica fibres from radial winch crush, hydrostatic collapse and downhole hydrogen darkening through a dual-barrier architecture: hermetic carbon/polymer fibre coatings inside a laser-welded stainless or nickel-alloy FIMT, armoured with torque-balanced contra-helical steel wires.

| Component | Material and construction |
|---|---|
| 1. Harsh-Environment Optical Fibres (SMF & 50/125 µm MMF, up to 300 °C) | 1 to 12 single-mode (9/125 µm G.657.A1 or pure-silica 1550 nm, <= 0.4–0.8 dB/km) and/or 50/125 µm graded-index multimode fibres (<= 3.0 dB/km at 850 nm, <= 1.2 dB/km at 1300 nm) with 150 °C acrylate, 200 °C carbon/silicone/PFA or 300 °C hermetic carbon/polyimide coatings (>= 100–200 kpsi proof test). |
| 2. Laser-Welded 316L Stainless-Steel or Alloy 825 FIMT | Precision cold-formed and continuous laser-welded 316L stainless-steel or Alloy 825 (UNS N08825) tube (1.80 to 2.80 mm OD) with controlled excess fibre length (EFL) and thixotropic hydrogen-scavenging gel. |
| 3. Polymeric Buffer or Hybrid Copper Power Core Layer | Extruded PE, copolymer PP or fluoropolymer FEP/ETFE cushion over the central FIMT on pure optical builds (4SSA27), or 2 to 6 stranded tinned/nickel-coated copper conductors (20 to 16 AWG, 500 to 1,200 V DC) helically cabled with the FIMT on FIMT-EO hybrid builds. |
| 4. Water-Blocking Bedding & Inter-Armour Sealant | High-temperature polymeric tape wrap and pressure-sealing anti-corrosion compound preventing wellbore gas migration and cushioning inner armour contact. |
| 5. Double Contra-Helical Preformed Wire (or Aramid-PUR) Armour | Two opposing helical layers of preformed GIPS/GEIPS galvanized steel or sour-service S75 / MP35N alloy wires (plus aramid-braided black PUR option on FIMT-6XM383 for non-metallic borehole electromagnetic surveys). |

4SSA27 / FIMT-OW / FIMT-EO Model & Coating Code Breakdown
- 4SSA27 / 4SSA27-80: double contra-helical galvanized steel wire armoured pure optical borehole cable housing up to 12 single-mode fibres in a 2.54–2.80 mm stainless-steel FIMT (6.60 / 8.00 mm OD)
- FIMT-OW125 / FIMT-OW250: low-profile 1/8 in (3.18 mm) and 1/4 in (6.35 mm) slickline-geometry armoured optical wirelines with 316L or Alloy 825 FIMT up to 300 °C
- FIMT-EO32 / FIMT-EO46: 5/16 in (8.18 mm) and 15/32 in (11.80 mm) hybrid electro-optical wirelines combining 2 or 6 fluoropolymer copper conductors (1,000–1,200 V DC) with a central multi-fibre FIMT
- CP / CSPFA / MTDA: downhole fibre coating tiers: Hermetic Carbon/Polyimide (300 °C), Carbon/Silicone/PFA (200 °C) and Mid-Temp Dual Acrylate (150 °C)
4SSA27 & FIMT-EO Downhole DTS, DAS, Geothermal & VSP Logging Applications
Deploy 4SSA27 and FIMT-EO optical and electro-optical wirelines across unconventional shale hydraulic-fracturing diagnostics, geothermal stimulation, CCUS injection monitoring and offshore borehole seismic surveys.

- Winch-deployed Distributed Acoustic Sensing (DAS) and Distributed Temperature Sensing (DTS) for multi-stage hydraulic fracture cluster efficiency, cross-well strain and leak detection.
- High-enthalpy geothermal borehole profiling (200 to 300 °C) and steam-assisted gravity drainage (SAGD) thermal chamber mapping using hermetic carbon/polyimide fibres.
- Vertical Seismic Profiling (VSP), downhole microseismic monitoring and CCUS CO2 storage plume verification without deploying heavy multi-level mechanical geophone shuttles.
- Hybrid electro-optical open-hole and cased-hole logging (FIMT-EO32 / FIMT-EO46) powering active downhole cameras, ultrasonic scanners, flowmeters and pressure gauges at 1,000–1,200 V DC.
4SSA27 Optical Wireline vs FIMT-EO Hybrid vs Permanent Downhole TEC
| Downhole Optical Architecture | Deployment Method | Electrical Power? | Primary Sensing & Logging Use Case |
|---|---|---|---|
| 4SSA27 / FIMT-OW Optical Wireline (this page) | Dynamic winch spooling (3.18–8.00 mm SWA) | No (100% optical FIMT) | Slickline-profile multi-well DAS, DTS, VSP & frac-hit diagnostics |
| FIMT-EO32 / FIMT-EO46 Hybrid (this page) | Dynamic wireline winch (8.18–11.80 mm SWA) | Yes (2 to 6 Cu cores, 1–1.2 kV DC) | Simultaneous powered downhole gauges/cameras/imagers + real-time DAS/DTS |
| FIMT-6XM383 Aramid-PUR EO (this page) | Portable borehole winch (14.30 mm PUR) | Yes (2x1.5 + 2x2x0.34 mm², 500 V) | Non-magnetic borehole EM surveys, shallow marine & hydrogeological sensing |
| Permanent Tubing Encased TEC / TEF | Clamped outside production tubing | 1–2 Cu cores or permanent FIMT | Life-of-well permanent PDHG gauge power & reservoir DTS/DAS monitoring |
Choose slim 3.18 to 6.60 mm FIMT-OW / 4SSA27 when shutting in a live high-pressure well through small lubricator grease tubes; choose 11.80 mm FIMT-EO46 when active logging tools require surface DC/AC power.
4SSA27 & FIMT Electro-Optical Wireline Cable RFQ Ordering Checklist
- Cable architecture: pure optical armoured wireline (FIMT-OW125, FIMT-OW250, 4SSA27), hybrid copper + optical wireline (FIMT-EO32, FIMT-EO46) or non-metallic aramid-PUR (FIMT-6XM383).
- Optical fibre count and mix inside the FIMT (for example 2 SM + 2 MM 50/125 µm for combined DAS + Raman DTS, or 12 x G.657.A1 SM on 4SSA27).
- Maximum bottomhole temperature and hydrogen exposure (150 °C acrylate, 200 °C carbon/PFA or 300 °C hermetic carbon/polyimide).
- Target outer diameter, minimum breaking load (kN) and armour metallurgy (GIPS galvanized steel vs S75 / MP35N sour-service alloy).
- Continuous splice-free length per drum (MOQ 50 m; lead time 7 to 45 working days) plus required OTDR test wavelengths.
Related selection resources
- Oil, gas and downhole electro-optical cable catalog
- Oilfield, HPHT downhole and offshore cable engineering guide
- Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable
- TEC Tubing Encased Permanent Downhole Gauge & Power Cable
- A302351 & A304097 (0.680 / 0.681 in) Steel-Armoured Electro-Optical Winch Cable
- Engineering guide: Monoconductor vs 4-Core Quad vs 7-Core Heptacable & FIMT Optical Wireline
4SSA27 & FIMT Electro-Optical Wireline Cable Frequently Asked Questions
What optical fibre combination should be specified inside a 4SSA27 or FIMT-EO wireline cable for simultaneous DTS and DAS logging?
2 single-mode fibres (ITU-T G.657.A1 or pure-silica 1550 nm) paired with 2 graded-index 50/125 µm multimode fibres inside one 2.4 to 2.54 mm laser-welded FIMT is the standard dual-sensing configuration: single-mode fibres drive coherent Rayleigh DAS/VSP interrogators while 50/125 µm multimode fibres serve Raman DTS temperature boxes.
How do 4SSA27 and FIMT-EO downhole cables prevent optical hydrogen darkening above 150 °C?
3 concentric barriers protect the glass core: a seamless laser-welded 316L stainless-steel or Alloy 825 metallic tube blocks bulk gas permeation, hydrogen-scavenging gel absorbs trace H2, and hermetic pyrolytic carbon + polyimide coatings on pure-silica fibres operate continuously up to 300 °C.
Can FIMT-EO46 hybrid electro-optical wireline run on a standard 15/32 inch (11.80 mm) heptacable logging drum?
Yes. FIMT-EO46 maintains the exact 11.80 ± 0.10 mm (15/32 in) outer diameter and 90 kN contra-helical steel armour envelope of a standard W7BPP-11.8 / 7J46 heptacable, replacing only the central core with a laser-welded 6-fibre FIMT surrounded by six 20 AWG copper power conductors.
When is non-metallic FIMT-6XM383 aramid-reinforced PUR cable preferred over steel-armoured 4SSA27?
0% ferromagnetic steel content makes FIMT-6XM383 (14.30 mm OD, 18 kN aramid braid, 2x1.5 mm² + 2x2x0.34 mm² + 4SM FIMT) essential for borehole electromagnetic (TEM/borehole radar) surveys where galvanized steel wire armour would distort downhole magnetic induction fields.
What are the minimum order quantity and delivery lead time for 4SSA27 and FIMT-EO optical logging cables?
50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days and factory 1310/1550 nm or 850/1300 nm OTDR test reports included per reel.
4SSA27 & FIMT-EO Dimensional, Optical, Thermal & Tensile Specifications
4SSA27 & FIMT-EO Key Fibre, Temperature, Voltage & Breaking-Load Summary
- Pure optical & hybrid EO wireline: Covers pure FIMT optical wirelines (3.18 to 8.00 mm, including 4SSA27 12SM) and hybrid copper + FIMT logging cables (8.18 to 14.30 mm)
- Hydrogen-resistant 150–300 °C fibres: Mid-temp acrylate (150 °C), carbon/silicone/PFA (200 °C) and hermetic carbon/polyimide pure-silica SMF & 50/125 µm MMF rated to 300 °C
- Laser-welded 316L & Alloy 825 FIMT: Seamless laser-welded metallic micro-tubes with hydrogen-scavenging gel withstand downhole hydrostatic pressures up to 100–140 MPa
- DTS, DAS & real-time HD logging: Enables distributed temperature sensing (DTS), distributed acoustic sensing (DAS), microseismic VSP and gigabit downhole imaging
- Winch-ready splice-free lengths: Minimum order quantity 50 m (calibration coils through continuous 3,000 to 8,500 m slickline/wireline drums) in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Optical-only dielectric core on 4SSA27 and FIMT-OW; 500 V to 1,200 V DC on hybrid copper-plus-fibre FIMT-EO builds |
| Optical fibre counts and modes | 1 to 12 fibres per FIMT combining ITU-T G.657.A1 / pure-silica 1550 nm SMF and 50/125 µm or 62.5/125 µm graded-index MMF |
| Fibre thermal and H2 protection | 150 °C mid-temp acrylate, 200 °C hermetic carbon/silicone/PFA, or 300 °C hermetic carbon/polyimide in hydrogen-scavenging gel |
| Outer diameter and breaking load | 3.18 mm (1/8 in, 8.5 kN), 6.35 mm (1/4 in, 28 kN), 6.60 mm (4SSA27, 31 kN), 8.18 mm (52 kN), 11.80 mm (90 kN) and 14.30 mm |
| Minimum bend diameter and supply | 250 mm to 610 mm minimum sheave diameter with MOQ 50 m and 7 to 45 working days manufacturing lead time |
| FIMT tube & armour metallurgy | 316L stainless steel or Alloy 825 (UNS N08825) FIMT inside preformed GIPS steel, S75/MP35N sour-service alloy or aramid-PUR armour |
| Optical attenuation benchmark | <= 0.4 to 0.8 dB/km at 1550 nm (SMF) and <= 3.0 / 1.2 dB/km at 850 / 1300 nm (50/125 µm carbon/polyimide MMF, > 300 MHz·km) |
4SSA27 & FIMT-EO Optical and Hybrid Wireline Dimensional & Tensile Schedule
| Model & Wireline Architecture | Nominal OD (mm) | Optical FIMT & Electrical Core | Temp. Class (°C) | Armour / Outer Package | Weight in Air (kg/km) | Min. Sheave | Breaking Load (mm | kN) | Next step |
|---|---|---|---|---|---|---|---|
| FIMT-OW125 Slim Optical Wireline (1/8 in) | 3.18 ± 0.08 | 1–4 SM/MM in 1.8 mm 316L/825 FIMT | 150 / 200 / 300 | 2-Layer Preformed GIPS or Alloy SWA | 42 | 250 | 8.5 | Request this size |
| FIMT-OW250 Optical Wireline (1/4 in) | 6.35 ± 0.10 | 4–8 SM/MM in 2.4 mm 316L/825 FIMT + Buffer | 150 / 200 / 300 | 2-Layer Preformed GIPS or MP35N SWA | 165 | 355 | 28.0 | Request this size |
| 4SSA27 12SM Armoured Optical Borehole | 6.60 ± 0.10 | 12xG.657.A1 SM in 2.54 mm SS FIMT + PE | 80 / 150 | 2-Layer Contra-Helical Hot-Dip Galv. SWA | 185 | 360 | 31.0 | Request this size |
| 4SSA27-80 Heavy Optical FIMT Wireline | 8.00 ± 0.10 | 4–12 SM/MM in 2.8 mm SS FIMT + PP/ETFE | 150 / 232 | 2-Layer Preformed GIPS SWA | 268 | 430 | 48.0 | Request this size |
| FIMT-EO32 Hybrid 2C+4F Wireline (5/16 in) | 8.18 ± 0.10 | 2x18 AWG Cu (1000 V) + 4F FIMT | 150 / 232 | 2-Layer Preformed GIPS or Alloy SWA | 275 | 460 | 52.0 | Request this size |
| FIMT-EO46 Hybrid 6C+6F Wireline (15/32 in) | 11.80 ± 0.10 | 6x20 AWG Cu (1200 V) + Center 6F FIMT | 150 / 232 / 260 | 20/26 Preformed GIPS or MP35N SWA | 505 | 550 | 90.0 | Request this size |
| FIMT-6XM383 Non-Metallic Borehole EO | 14.30 ± 0.20 | 2x1.5 + 2x2x0.34 mm² (500 V) + 4SM FIMT | 90 | Foil/Braid Shield + Aramid Braid + Black PUR | 230 | 280 | 18.0 | Request this size |
4SSA27 & FIMT Downhole Optical Fibre Coating & Hydrogen Protection Matrix
| Fibre Coating Grade | Operating Temp. (°C) | Hermetic H2 Barrier | Supported Fibre Geometries | Typical Attenuation & Proof Test |
|---|---|---|---|---|
| Mid-Temp Dual Acrylate (MTDA) | -40 to +150 °C | Optional Carbon + H2 Gel | 9/125 µm G.657.A1 SM & 50/125/245 µm MM | <= 0.4 dB/km (1550 nm); >= 100 kpsi |
| Carbon / Silicone / PFA (CSPFA) | -40 to +200 °C | Hermetic Carbon Layer | Pure-Silica 125/250–400 µm SM & 50/125 µm MM | <= 0.8 dB/km (1550 nm); >= 100–150 kpsi |
| Hermetic Carbon / Polyimide (CP) | -65 to +300 °C | Full Hermetic Carbon + Pure Silica | 125/155 µm Pure-Silica SM & 50/125/155 µm MM | <= 0.8 dB/km (1550 nm) | <= 3.0/1.2 (850/1300 nm); >= 100–200 kpsi |
On 15/32 in FIMT-EO46 (11.80 mm), replacing the central 7th copper wire of a standard 6+1 heptacable with a 2.0 to 2.4 mm laser-welded 316L/Alloy 825 FIMT preserves full compatibility with standard 15/32 in winch drums, Lebus grooves and grease-injection pack-off tubes.
Above 150 °C in hydrogen-rich gas or geothermal wells, always specify pure-silica-core single-mode fibre and hermetic carbon/polyimide coating inside hydrogen-scavenging gel to prevent OH-absorption darkening at 1383 nm and 1550 nm.
Minimum order quantity is 50 m with a factory lead time of 7 to 45 working days, including full two-way OTDR attenuation traces at 1310/1550 nm (SM) or 850/1300 nm (MM) on every shipping drum.
ASCII part references: 4SSA27; 4SSA27-80; FIMT-OW125; FIMT-OW250; FIMT-EO32; FIMT-EO46; FIMT-6XM383; 6XM383; SMF-CP-125; MMF-50-CP-125.
4SSA27 & FIMT Downhole Optical Fibre, OTDR & Sour-Service Standards
| Standard or specification | Application |
|---|---|
| ITU-T G.657.A1 & Pure-Silica 1550 nm SMF | Macro-bend-insensitive single-mode optical fibres maintaining low Rayleigh backscatter loss inside compact 1.8 to 2.8 mm metallic tubes. |
| IEC 60794-1-2 & OTDR / Hydrostatic Verification | 100% bi-directional OTDR continuity/attenuation testing, excess fibre length (EFL) control and laser-weld eddy-current/pressure integrity checks. |
| ISO 15156 / UNS N08825 & UNS R30035 Metallurgy | Alloy 825 FIMT tubes and MP35N / S75 sour-service contra-helical armour options for H2S/CO2 intervention and geothermal brine wells. |
Certifications and document support
TEBAOFLEX ISO 9001 quality system, OTDR optical attenuation and tensile test documentation
ITU-T G.657 — Bending-loss insensitive single-mode optical fibre characteristics for FIMT cables
ISO 15156-3 — Corrosion-resistant Alloy 825 and superalloy selection for sour downhole service
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in)
A related cable option for a different application or duty profile.
View productHeptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC)
A related cable option for a different application or duty profile.
View product4H18, A240 & 6SSA5 4-Conductor Quad & Multi-Core Borehole Geophysical Logging Cable (300–1200 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.