Type MC MV-105 5 kV–35 kV Interlocked Armored Mine Plant & Industrial Feeder Cable (4 AWG–1000 kcmil)
Type MC MV-105 5 kV–35 kV Interlocked Armored Feeder Cable provides heavy crush-resistant medium-voltage power distribution from 4 AWG to 1000 kcmil for mineral concentrators, SAG/ball mill substations, overland conveyors and industrial plants. Engineered to UL 1072, ICEA S-93-639 / NEMA WC 74 and NEC Article 328 / NOM-001-SEDE specifications, it combines triple-extruded 105 °C EPR (or 90 °C TR-XLPE) shielded cores, bare copper ground, aluminum or steel interlocked armor, and PVC/CPE/LSZH overall jacketing.
Type MC MV-105 5 kV–35 kV Interlocked Armored Mine Plant and Industrial Feeder Cable delivers conduit-free medium-voltage power across copper/gold concentrators, primary crusher galleries, SX-EW rectiformer yards and refinery racks from 4 AWG up to 1000 kcmil (O.D. 39.1 mm to 109.2 mm, in-air ampacity 120 A to 755 A).
Pulling unarmored single-core medium-voltage cables through thick-wall rigid steel conduit across multi-level grinding bays and trestle bridges inflates installation labor and traps condensation. Type MC MV-105 replaces conduit with a factory-assembled 3-conductor cabled core: compact Class B annealed copper conductors, dry-cured triple-extruded semiconductive screens with discharge-resistant +105 °C EPR (or +90 °C tree-retardant XLPE), individual copper tape or wire metallic shields, a bare copper grounding conductor, and a high-crush aluminum (AIA) or galvanized steel (GSIA) interlocked strip armor sealed beneath a sunlight-, oil- and acid-resistant red or black PVC, CPE or halogen-free LSZH overall jacket.
Specify Type MC MV-105 Interlocked Armor for fixed ladder-tray, aerial messenger, direct-burial-rated and NEC Class I/II Division 2 mineral-processing feeders; choose Type MP-GC or vertical wire-armored Type MPF-GC when MSHA-style pilot ground-check monitoring is required underground, or switch to Type MC-HL continuous corrugated welded aluminum armor for Class I Division 1 vapor-tight VFD runs. Minimum order quantity 300 m; lead time 7 to 45 working days.
Explore the mining and tunneling cable range for related configurations.
Type MC MV-105 5 kV–35 kV Armored Cable Construction
Engineered in accordance with UL 1072, ICEA S-93-639 / NEMA WC 74 (and ICEA S-97-682 utility reference) for 5 kV to 35 kV shielded metal-clad power distribution.

| Component | Material and construction |
|---|---|
| 1. Phase Conductors (3 × Compact Class B Copper) | Annealed uncoated (or tinned) compact concentric-lay Class B copper per ASTM B3, ASTM B8 and ASTM B496 from 4 AWG through 1000 kcmil (AA-8000 aluminum optional on request). |
| 2. Triple-Extruded Screens & 105 °C EPR / TR-XLPE | Extruded thermoset conductor screen + 100% or 133% wall +105 °C EPR (or +90 °C TR-XLPE) primary insulation + controlled-strip extruded thermoset insulation screen. |
| 3. Individual Phase Metallic Shield | Helically applied 5-mil (0.127 mm) bare copper tape with >=12.5%–25% overlap, or helically applied #22–#18 AWG bare copper wire shield per fault-current schedule. |
| 4. Grounding Conductor, Fillers & Binder | Stranded bare annealed copper equipment grounding conductor sized to UL 1072 / NEC Table 250.122 with non-hygroscopic polypropylene fillers and binder tape. |
| 5. Interlocked Metal Armor & Overall Jacket | Helically interlocked Aluminum Strip Armor (AIA, non-magnetic light weight) or Galvanized Steel Strip Armor (GSIA, peak crush resistance) under red or black PVC, CPE or LSZH jacket. |
Type MC MV-105, AIA/GSIA & 100%/133% Designation Breakdown
- Type MC (Metal-Clad): Factory-assembled multi-conductor power cable armored with interlocking metallic strip for direct cable-tray and exposed industrial routing
- MV-105 (105 °C Rating): Medium-voltage power cable architecture rated up to +105 °C continuous conductor operation (+140 °C emergency overload, +250 °C short-circuit with EPR)
- 100% vs. 133% Insulation Level: 100% wall (e.g., 4.45 mm / 175 mils at 15 kV) for grounded systems clearing faults within 1 minute; 133% wall (5.46 mm / 215 mils at 15 kV) for ungrounded/resonant mine grids
- AIA vs. GSIA Armor: Aluminum Interlocked Armor cuts weight and inductive loss in corrosive mill air; Galvanized Steel Interlocked Armor maximizes rock-fall crush resistance
- NOM-001-SEDE / NEC Art. 328: North American and Mexican EPC electrical installation codes governing 5 kV–35 kV Type MC industrial feeders
Type MC MV-105 Mine Concentrator & Plant Feeder Applications
Designed for fixed medium-voltage primary distribution across surface mine processing plants, underground main substations and heavy industrial facilities.

- Copper, gold, lithium and iron-ore concentrator SAG mill, ball mill, HPGR and flotation blower 5 kV, 13.8 kV (15 kV class) and 23–34.5 kV feeders.
- Overland conveyor drive stations, primary gyratory crusher substations, tailings pump boosters and SX-EW transformer-rectifier feeds.
- Ladder cable trays, outdoor pipe racks, concrete trenches, underground ducts and Class I / II Division 2 industrial locations per NEC / NOM-001-SEDE.
- Replacement or US/LATAM EPC alternative to Canadian CSA HVTECK90 armored cables when UL 1072 / ICEA S-93-639 AWG/kcmil schedules are specified.
- Bulk export reel supply (MOQ 300 m per size, 7 to 45 working days) with factory HV AC withstand and partial-discharge routine test reports.
Type MC MV-105 vs. CSA HVTECK, Type MP-GC & Type MPF-GC Matrix
| Cable Type | Armor & Ground-Check | Voltage Range | When to Specify |
|---|---|---|---|
| Type MC MV-105 (this page) | AIA/GSIA interlocked strip armor, 1 ground (no GC) | 5 kV–35 kV | US/LATAM concentrator ladder trays, SAG/ball mills & Class I/II Div 2 plants |
| CSA HVTECK90 (WC 6884) | AIA interlocked armor per CSA C22.2 No. 131/38 | 5 kV–15 kV | Canadian CEC mine mills & cold -40 °C FT4 surface processing plants |
| Type MP-GC (WC 6890) | Unarmored heavy CPE jacket + 2 grounds + 1 GC | 5 kV–35 kV | Underground mine entries, boreholes & semi-mobile skid substations needing GC |
| Type MPF-GC (WC 7122) | Galvanized round steel wire armor (SWA) + GC | 5 kV–35 kV | Vertical mine shafts & steep boreholes requiring self-supporting tensile SWA |
Specify 133% insulation level whenever your mine substation utilizes high-resistance neutral grounding (NGR) or ungrounded fault-alarmed operation.
Type MC MV-105 Medium-Voltage Feeder RFQ Checklist
- System nominal voltage (5, 8, 15, 25 or 35 kV) and insulation level (100% grounded or 133% ungrounded/NGR).
- Phase conductor size (4 AWG to 1000 kcmil) and insulation polymer (+105 °C EPR vs. +90 °C TR-XLPE).
- Armor and outer jacket choice: Aluminum Interlocked Armor (AIA) or Galvanized Steel Interlocked Armor (GSIA) + Red/Black PVC, CPE or LSZH.
- Installation environment: open ladder tray, direct burial, concrete duct bank, high-altitude derating (>1,000 m), or NEC Class I/II Div 2.
- Reel cut lengths and total meterage (minimum order quantity 300 m per size; lead time 7 to 45 working days).
Related selection resources
- Mining & Tunneling Cables Catalog
- TPU vs. CPE Mining Trailing Cable Jacket Selection Guide
- Type MV-105 Cable 5kV, 15kV & 35kV Engineering Selection Guide
- Type MP-GC 5kV–35kV EPR/CPE Mine Power Feeder Cable
- CSA TECK90 & HVTECK Armored Mine Cable
Type MC MV-105 Interlocked Armored Cable FAQ
When should a mine concentrator specify 133% insulation level on Type MC MV-105 cable?
133% wall thickness is required whenever phase-to-ground faults are not cleared automatically within 1 minute—including resistance-grounded (NGR) or ungrounded mine distribution buses that stay energized up to 1 hour during fault location.
Should I select Aluminum Interlocked Armor (AIA) or Galvanized Steel Interlocked Armor (GSIA) on Type MC MV-105?
Aluminum Interlocked Armor cuts cable weight by 18%–26% and resists humid acid-mist corrosion in flotation and SX-EW halls, whereas Galvanized Steel Interlocked Armor delivers maximum impact and rock-crush protection in coarse-ore crusher tunnels.
Does Type MC MV-105 include a ground-check pilot wire for underground mobile couplers?
No. Standard Type MC MV-105 contains three shielded phases plus one bare equipment ground for fixed plant switchgear; if your circuit feeds MSHA-monitored underground power centers with pilot relays, specify Type MP-GC or wire-armored Type MPF-GC (custom pilot-equipped MC builds available on 300 m+ order).
Is TEBAOFLEX Type MC MV-105 supplied with UL Listing or ANCE certification marks?
No. This series is engineered and manufactured to UL 1072, ICEA S-93-639 and NOM-001-SEDE construction and HV routine test specifications (AC withstand + partial discharge), and third-party NRTL/ANCE certification is not claimed.
What is the minimum order quantity and delivery time for Type MC MV-105 5 kV–35 kV cable?
300 m per voltage and cross-section is our factory minimum order quantity, shipped on heavy steel-wood export reels in 7 to 45 working days.
Type MC MV-105 5 kV–35 kV Dimensional & Ampacity Schedules
Type MC MV-105 Key Engineering Highlights
- Full 5, 8, 15, 25 & 35 kV voltage range: Manufactured in 100% and 133% insulation levels (2.29 mm to 8.76 mm nominal wall) across 4 AWG through 1000 kcmil Class B compact copper
- True triple-extruded dry-cured MV core: Simultaneously extruded conductor screen, 105 °C EPR (or TR-XLPE) dielectric and strippable insulation screen eliminate micro-void partial discharge
- Copper tape or wire shield + bare ground: 5-mil helically overlapped bare copper tape shield (or concentric copper wire shield) over each phase plus dedicated bare copper equipment ground
- AIA aluminum or GSIA steel interlocked armor: High-crush helical interlocked strip armor eliminates heavy rigid conduit installation across ladder trays, trestles and Class I/II Div 2 zones
- 300 m bulk MOQ & custom reel lengths: Produced to order on heavy export reels from 300 m minimum order quantity per size with a 7 to 45 working days lead time
| Parameter | Value |
|---|---|
| Rated voltage | 5 kV, 8 kV, 15 kV, 25 kV and 35 kV in 100% and 133% insulation levels (engineered to UL 1072 and ICEA S-93-639) |
| Operating temperature range | -40 °C fixed installation up to +105 °C continuous with EPR (+90 °C with TR-XLPE); +130/+140 °C overload and +250 °C short-circuit |
| Conductor and shielding | 3 × Class B compact copper (4 AWG to 1000 kcmil) with triple-extruded screens, copper tape or wire shield, plus bare copper ground |
| Armor and outer jacket | Aluminum (AIA) or galvanized steel (GSIA) interlocked strip armor under sunlight- and oil-resistant PVC, thermoset CPE or LSZH jacket |
| Minimum bending radius | 7 × overall cable diameter during fixed installation for interlocked-armor Type MC MV-105 constructions |
| Standards and flame reference | Manufactured to UL 1072, ICEA S-93-639 / NEMA WC 74 and IEEE 1202 / FT4 vertical tray flame test methods; NRTL listing not claimed |
| Minimum order and lead time | 300 m minimum order quantity per voltage and conductor size; manufacturing lead time 7 to 45 working days |
Type MC MV-105 5 kV & 8 kV (100% Wall) Interlocked Armored Feeder Schedule
| Model & Size | Strands | Insulation Wall (mm) | Ground Size | Armor OD (mm) | Overall OD (mm / in) | Approx. Weight (kg/km) | In-Air Ampacity (A) | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|---|---|
| Type MC MV-105 5kV 3/C 4 AWG | 7 | 2.29 | 6 AWG | 36.6 | 39.1 / 1.54 | 2300 | 120 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 2 AWG | 7 | 2.29 | 6 AWG | 39.6 | 42.7 / 1.68 | 2865 | 160 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 1/0 AWG | 19 | 2.29 | 4 AWG | 43.2 | 46.5 / 1.83 | 3690 | 215 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 2/0 AWG | 19 | 2.29 | 4 AWG | 45.5 | 48.8 / 1.92 | 4160 | 245 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 4/0 AWG | 19 | 2.29 | 3 AWG | 52.8 | 56.1 / 2.21 | 5720 | 325 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 250 kcmil | 37 | 2.29 | 3 AWG | 55.9 | 59.2 / 2.33 | 6470 | 360 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 350 kcmil | 37 | 2.29 | 2 AWG | 61.2 | 65.0 / 2.56 | 8360 | 440 | 300 m | Request this size |
| Type MC MV-105 5kV 3/C 500 kcmil | 37 | 2.29 | 1 AWG | 67.8 | 71.6 / 2.82 | 10970 | 545 | 300 m | Request this size |
| Type MC MV-105 8kV 3/C 2/0 AWG | 19 | 2.92 | 4 AWG | 50.3 | 53.6 / 2.11 | 4480 | 245 | 300 m | Request this size |
| Type MC MV-105 8kV 3/C 4/0 AWG | 19 | 2.92 | 3 AWG | 55.6 | 58.9 / 2.32 | 5975 | 325 | 300 m | Request this size |
| Type MC MV-105 8kV 3/C 350 kcmil | 37 | 2.92 | 2 AWG | 64.0 | 67.8 / 2.67 | 8625 | 440 | 300 m | Request this size |
| Type MC MV-105 8kV 3/C 500 kcmil | 37 | 2.92 | 1 AWG | 71.9 | 75.7 / 2.98 | 11415 | 545 | 300 m | Request this size |
Type MC MV-105 15 kV, 25 kV & 35 kV (100% Wall) Interlocked Armored Feeder Schedule
| Model & Size | Strands | Insulation Wall (mm) | Ground Size | Armor OD (mm) | Overall OD (mm / in) | Approx. Weight (kg/km) | In-Air Ampacity (A) | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|---|---|
| Type MC MV-105 15kV 3/C 2 AWG | 7 | 4.45 | 6 AWG | 51.1 | 54.4 / 2.14 | 3645 | 165 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 1/0 AWG | 19 | 4.45 | 4 AWG | 54.9 | 57.9 / 2.28 | 4510 | 215 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 2/0 AWG | 19 | 4.45 | 4 AWG | 57.2 | 60.2 / 2.37 | 5070 | 245 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 3/0 AWG | 19 | 4.45 | 3 AWG | 59.7 | 63.5 / 2.50 | 5895 | 285 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 4/0 AWG | 19 | 4.45 | 3 AWG | 62.5 | 66.3 / 2.61 | 6710 | 325 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 250 kcmil | 37 | 4.45 | 3 AWG | 65.5 | 69.3 / 2.73 | 7500 | 360 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 350 kcmil | 37 | 4.45 | 2 AWG | 71.9 | 75.9 / 2.99 | 9495 | 440 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 500 kcmil | 37 | 4.45 | 1 AWG | 78.5 | 83.1 / 3.27 | 12285 | 545 | 300 m | Request this size |
| Type MC MV-105 15kV 3/C 750 kcmil | 61 | 4.45 | 1/0 AWG | 88.1 | 92.7 / 3.65 | 16690 | 685 | 300 m | Request this size |
| Type MC MV-105 25kV 3/C 1/0 AWG | 19 | 6.60 | 4 AWG | 63.8 | 67.6 / 2.66 | 5460 | 215 | 300 m | Request this size |
| Type MC MV-105 25kV 3/C 4/0 AWG | 19 | 6.60 | 3 AWG | 72.6 | 76.5 / 3.01 | 7785 | 325 | 300 m | Request this size |
| Type MC MV-105 25kV 3/C 350 kcmil | 37 | 6.60 | 2 AWG | 80.8 | 85.3 / 3.36 | 10620 | 440 | 300 m | Request this size |
| Type MC MV-105 25kV 3/C 500 kcmil | 37 | 6.60 | 1 AWG | 87.4 | 91.9 / 3.62 | 13390 | 545 | 300 m | Request this size |
| Type MC MV-105 35kV 3/C 4/0 AWG | 19 | 8.76 | 3 AWG | 82.6 | 86.9 / 3.42 | 9060 | 325 | 300 m | Request this size |
| Type MC MV-105 35kV 3/C 500 kcmil | 37 | 8.76 | 1 AWG | 97.3 | 101.9 / 4.01 | 14740 | 545 | 300 m | Request this size |
Dimensional weights reflect galvanized steel interlocked armor (GSIA) construction reference values; choosing Aluminum Interlocked Armor (AIA) reduces approximate cable mass by 18%–26%, and final values are confirmed on the quotation drawing.
133% insulation wall schedules (2.92 mm at 5 kV, 3.56 mm at 8 kV, 5.46 mm at 15 kV, 8.13 mm at 25 kV, 10.67 mm at 35 kV) and 600–1000 kcmil cross-sections are manufactured to order.
ASCII part references for BOM and ERP entry: TF-MIN-MCMV105-5-35KV, TYPE-MC-MV105-5KV-4/0, TYPE-MC-MV105-15KV-2/0, TYPE-MC-MV105-15KV-4/0, TYPE-MC-MV105-15KV-350, TYPE-MC-MV105-15KV-500, TYPE-MC-MV105-25KV-4/0, TYPE-MC-MV105-35KV-500.
Type MC MV-105 Standards & HV Routine Test References
| Standard or specification | Application |
|---|---|
| UL 1072 (Construction Reference) | Medium-voltage solid-dielectric power cable dimensional, triple-extrusion screen and routine HV withstand/partial-discharge reference (NRTL listing not claimed). |
| ICEA S-93-639 / NEMA WC 74 | 5–46 kV shielded power cable conductor, EPR/TR-XLPE wall thickness and metallic shield specification. |
| UL 1569 & NEC Article 328 / NOM-001-SEDE | Metal-clad interlocked armor construction and industrial tray / Division 2 routing framework across US and Mexican mine plants. |
| IEEE 1202 / CSA FT4 | Vertical cable-tray flame-propagation test reference for PVC, CPE and halogen-free LSZH outer jackets. |
ICEA S-93-639 / NEMA WC 74 5–46 kV Shielded Power Cable Standard
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD & Hazardous-Location Mining Cable
A related cable option for a different application or duty profile.
View productType MV-105 EPR Copper-Tape-Screened Distribution Cable, 15 kV and 35 kV
A related cable option for a different application or duty profile.
View productPolymeric-Armored Type MV-105 / MP-GC Feeder Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.