MINING & TUNNELING CABLES TEBAOFLEX

Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD & Hazardous-Location Mining Cable

Type MC-HL 600 V & 2 kV Armored VFD and Hazardous-Location Mining Cable combines three XLPE or corona-resistant 2 kV EPR phase conductors, three symmetrical bare copper grounds, a gas- and liquid-tight continuous corrugated welded aluminum sheath, and a chemical-resistant CPE/PVC outer jacket from 14 AWG to 750 kcmil. Engineered to UL 2225, ICEA S-95-658 and NEC Articles 501/502, it eliminates motor bearing fluting and conduit runs in Class I/II Division 1 mine plants.

Product information
SKU
TF-MIN-MCHL-VFD
Brand
TEBAOFLEX
Product overview

Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD and Hazardous-Location Cable solves two critical mineral-processing failures simultaneously—IGBT PWM common-mode motor bearing damage and hazardous-vapor ingress—across 14 AWG through 750 kcmil (O.D. 15.2 mm to 78.5 mm, +90 °C ampacity 25 A to 535 A).

Ordinary helical interlocked strip armor (standard Type MC) leaves spiral mechanical gaps that cannot block organic solvent vapors in copper SX-EW extraction mixers or act as a low-inductance path for megahertz VFD switching noise. Type MC-HL forms a continuous longitudinal aluminum strip around a symmetrical 3-phase + 3-ground core, TIG-welds the seam airtight, and annularly/helically corrugates the tube for tray bendability before extruding a heavy black chemical-, oil- and UV-resistant CPE (or low-smoke zero-halogen) jacket. On long >60 m variable-frequency slurry-pump, flotation-agitator and mill-pinion runs, stepping up to the 2000 V EPR dielectric wall prevents standing-wave corona breakdown from fast-rise-time drives.

Specify Type MC-HL 600 V or 2 kV when routing VFD motor leads or hazardous-area feeders in NEC Class I/II Division 1 & 2 concentrators, SX-EW plants, potash refineries and offshore/petrochemical skids; choose portable rubber Mining VFD 2000 V (WC 5916) or 5–15 kV VFD-GC (WC 7047) for mobile trailing machinery, or Type MC MV-105 for 5–35 kV medium-voltage feeders. Minimum order quantity 300 m; lead time 7 to 45 working days.

Explore the mining and tunneling cable range for related configurations.

Construction

Type MC-HL 600 V & 2 kV Welded-Armor VFD Construction

Engineered in accordance with UL 2225, UL 1569, ICEA S-95-658 / NEMA WC 70 and IEEE 1580 / NEC 501–502 design criteria for continuous-corrugated welded armored hazardous-location and VFD power cables.

Type MC-HL symmetrical VFD cable 2D cross-section showing black outer CPE jacket, silver continuous corrugated welded aluminum ring, three XLPE/EPR cores and three interstitial grounds
Balanced 3-phase + 3-symmetrical-ground geometry enclosed inside a gas-tight continuous corrugated welded aluminum sheath.
Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD & Hazardous-Location Mining Cable construction
ComponentMaterial and construction
1. Phase Conductors (3 × Stranded Annealed Copper)Class B concentric-lay or flexible Class C/K annealed bare or tinned copper per ASTM B3 / B8 / B33 from 14 AWG up to 750 kcmil.
2. 90 °C Primary Dielectric (600 V XLPE or 2 kV Corona-Resistant EPR)Low-capacitance cross-linked polyethylene (XLPE / XHHW-2 grade) for 600 V circuits, or heavy-wall 2000 V discharge-resistant EPR (RHW-2 grade) for high-dV/dt VFD leads.
3. Symmetrical 3-Conductor Equipment GroundsThree uninsulated stranded copper grounding conductors positioned symmetrically at 120° in the three outer valleys to cancel net electromagnetic field imbalance.
4. Continuous Corrugated Welded (CCW) Aluminum ArmorImpervious longitudinally welded and corrugated aluminum alloy tube providing crush/impact strength, 100% shield coverage and gas/moisture exclusion.
5. Chemical- & Sunlight-Resistant Outer JacketExtruded heavy-duty black Chlorinated Polyethylene (CPE), PVC or halogen-free polyolefin (LSZH) jacket resisting sulfuric acid mist, SX kerosene diluents and UV.

Type MC-HL, CCW Aluminum & 3+3 VFD Designation Breakdown

  • MC-HL (Metal-Clad Hazardous Location): Continuous-sheath armored cable architecture engineered for Class I, II and III Division 1 & 2 hazardous plant zones with listed MC-HL barrier glands
  • CCW (Continuous Corrugated Welded): Seamless welded aluminum tube armor delivering impervious vapor sealing plus 360-degree low-transfer-impedance VFD EMI containment
  • 3C + 3G Symmetrical VFD Core: Balanced triangular phase layout with three equal interstitial grounds eliminating stray ground-loop currents through mill structural steel
  • 2 kV RHW-2 EPR Option: Thickened 2000 V thermoset EPR wall surviving 2×–3× DC-bus reflected voltage peaks on long variable-frequency motor cable runs
  • SX-EW & Prep-Plant Ready: Outer CPE compound formulated against solvent-extraction organic diluents, raffinate acid splash and coal-washery flotation reagents
Applications

Type MC-HL SX-EW, Prep-Plant & Mill VFD Applications

Engineered for fixed VFD motor drives and hazardous-atmosphere power circuits in mineral processing, chemical leaching and coal preparation facilities.

Type MC-HL continuous corrugated welded aluminum armored cables terminated with barrier glands on variable-frequency slurry pump motors in a copper SX-EW processing plant
Hazardous-location mineral processing and SX-EW variable-frequency pump drives wired with impervious Type MC-HL armored cable.
  • Copper, cobalt, nickel and uranium SX-EW (Solvent Extraction & Electrowinning) mixer-settler drives and tankhouse pump skids (Class I Div 1/2 organic vapors).
  • SAG/ball mill cyclone feed slurry pumps, thickener underflow VFD drives, filter presses and flotation blowers on 480 V, 600 V and 690 V PWM inverters.
  • Coal preparation plants, methane degasification compressor skids, grain/potash/sulfur dust handling conveyors (Class II Div 1/2).
  • Long-run (>50 m to 250 m) IGBT VFD motor feeders using the 2000 V EPR construction to stop premature insulation pinholing and shaft EDM bearing pitting.
  • Supplied in 300 m minimum bulk reels (lead time 7 to 45 working days) with factory spark, AC dielectric and weld-seam pressure/integrity testing.

Type MC-HL vs. Type MC MV-105 & Portable Mining VFD Matrix

Mining VFD & Hazardous-Area Cable Selection: Type MC-HL vs. Type MC MV-105 vs. Portable 2 kV Mining VFD
Cable ArchitectureMetallic Sheath / ScreenInstallation MobilityTarget Mining Duty
Type MC-HL 600V/2kV (this page)Impervious continuous corrugated welded Al + 3 groundsFixed tray / Div 1 & 2SX-EW solvent tankhouses, prep plants & mill VFD slurry pumps
Type MC MV-105 (NM4)Helical AIA/GSIA interlocked strip + phase shieldsFixed tray / Div 25 kV–35 kV primary concentrator & SAG/ball mill substation feeders
Mining VFD 2000 V (WC 5916)Flexible tinned Cu braid/foil + 3 grounds + GCFlexible trailing / reelingMobile underground VFD shuttle cars, shearers & drill rigs
37-102 Instrumentation (WC 7449)Individual & overall foil shields + crush jacketFixed / semi-mobile tray0.6/1 kV 4–20 mA, Hart & PLC sensor pairs in mine plants

For 480–690 V PWM VFD motor leads longer than 50 m or driven by active-front-end (AFE) inverters, always select the 2000 V EPR Type MC-HL table.

Type MC-HL Hazardous-Location & VFD Cable RFQ Checklist

  • Voltage tier: 600 V XLPE (XHHW-2 grade) vs. 2000 V corona-resistant EPR (RHW-2 grade for long VFD runs).
  • Phase conductor size (14 AWG to 750 kcmil) and stranding class (Class B standard vs. Class C/K flexible for tight gland bends).
  • Optional integrated control pair (e.g., 1 shielded pair 16 AWG or 14 AWG for motor space heater, thermistor or brake).
  • Outer jacket compound: chemical-resistant black CPE (SX-EW kerosene/acid service), sunlight PVC, or halogen-free LSZH.
  • Cut lengths per reel and total meterage (minimum order quantity 300 m per size; lead time 7 to 45 working days).

Related selection resources

Type MC-HL Corrugated Welded Aluminum VFD Cable FAQ

Why is continuous corrugated welded aluminum (Type MC-HL) superior to interlocked armor on VFD motor drives?

100% 360-degree solid tube continuity is the reason: welded corrugated aluminum provides a low-impedance, zero-gap return path for high-frequency PWM common-mode noise and blocks flammable solvent vapors, whereas helical interlocked strip armor exhibits inductive slot leakage and vapor gaps.

When should I upgrade from 600 V XLPE Type MC-HL to 2000 V EPR Type MC-HL?

Above 50 m motor lead length on 480 V–690 V IGBT drives (or on any active-front-end VFD), reflected-wave voltage doubling creates 1,300–1,800 V spikes at the motor terminals; the thicker 2000 V corona-resistant EPR wall prevents premature partial-discharge pinholing.

Why does TEBAOFLEX Type MC-HL use three bare grounds instead of a single ground wire?

3 symmetrical grounds spaced 120° apart equalize phase-to-ground capacitance across all three phases, preventing unbalanced circulating ground currents from discharging through motor roller bearings (EDM fluting).

Does this Type MC-HL series carry UL 2225 Listing marks?

No. Our Type MC-HL cables are manufactured in accordance with UL 2225, UL 1569 and ICEA S-95-658 construction, weld-seam integrity and dielectric test specifications; third-party UL Listing is not claimed.

What is the minimum order quantity and delivery schedule for Type MC-HL cable?

300 m per cross-section and voltage rating is the minimum order quantity for continuous-welded aluminum armor runs, with delivery in 7 to 45 working days.

Specifications

Type MC-HL 600 V & 2000 V Dimensional & Ampacity Schedules

Type MC-HL Key Engineering Highlights

  • Impervious continuous welded aluminum armor: Argon-arc welded and corrugated seamless aluminum tube creates a 100% gas-, vapor- and moisture-impervious barrier Plus 360° low-impedance EMC VFD shielding
  • 3 symmetrical ground wires (3+3 VFD geometry): Three equal bare copper grounds placed symmetrically in the phase valleys balance capacitive coupling and drain high-frequency IGBT common-mode shaft currents
  • Dual 600 V XHHW-2 & 2 kV RHW-2 EPR ratings: Choose 600 V cross-linked XLPE for general VFD/plant feeders or thick-wall 2000 V corona-resistant EPR to withstand >1,600 V PWM reflected-wave spikes
  • Built for SX-EW, coal prep & mill drives: Resists organic kerosene/acid mist in copper SX-EW tankhouses, coal dust in wash plants, and cyanide/reagent splashes in gold CIL/CIP circuits
  • 300 m bulk MOQ & gland-ready roundness: Manufactured from 300 m minimum order quantity (lead time 7 to 45 working days) with precision sheath concentricity for explosion-proof MC-HL barrier glands
Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD & Hazardous-Location Mining Cable technical data
ParameterValue
Rated voltage600 V (1000 V IEC ref) XLPE and 2000 V (2 kV) corona-resistant EPR VFD and hazardous-location power ratings
Operating temperature range-40 °C cold impact/bend up to +90 °C continuous wet or dry conductor temperature (+130 °C overload, +250 °C short-circuit)
Core and ground geometry3 insulated copper phase conductors (14 AWG to 750 kcmil) plus 3 symmetrical bare copper interstitial grounds
Armor and outer jacketImpervious continuous corrugated welded aluminum sheath (100% EMC shield) under black chemical- and sunlight-resistant CPE or PVC jacket
Minimum bending radius10 × to 12 × overall cable diameter during installation for continuous corrugated welded aluminum sheath
Standards and flame referenceEngineered to UL 2225, UL 1569, ICEA S-95-658 and IEEE 1202 / FT4 tray flame test criteria; third-party NRTL listing is not claimed
Minimum order and lead time300 m minimum order quantity per voltage and gauge; manufacturing lead time 7 to 45 working days

Type MC-HL 600 V Symmetrical 3-Ground XLPE/CCW-Al/CPE Dimensional Schedule

Type MC-HL 600 V Symmetrical 3-Ground VFD & Hazardous-Location Cable (90 °C XLPE + Continuous Corrugated Welded Al + CPE) — Dimensional Schedule
Model & GaugePhase StrandsXLPE Wall (mm)3 × Symm. GroundsWelded Al OD (mm)Overall OD (mm / in)Approx. Weight (kg/km)Ampacity @90 °C (A)Bulk MOQNext step
Type MC-HL 600V 3/C 14 AWG70.763 × 18 AWG12.415.2 / 0.6026525300 mRequest this size
Type MC-HL 600V 3/C 12 AWG70.763 × 16 AWG13.516.3 / 0.6432530300 mRequest this size
Type MC-HL 600V 3/C 10 AWG70.763 × 14 AWG15.017.8 / 0.7041540300 mRequest this size
Type MC-HL 600V 3/C 8 AWG71.143 × 14 AWG18.821.6 / 0.8561055300 mRequest this size
Type MC-HL 600V 3/C 6 AWG71.143 × 12 AWG21.124.1 / 0.9582075300 mRequest this size
Type MC-HL 600V 3/C 4 AWG71.143 × 12 AWG24.127.2 / 1.07113595300 mRequest this size
Type MC-HL 600V 3/C 2 AWG71.143 × 10 AWG27.430.7 / 1.211610130300 mRequest this size
Type MC-HL 600V 3/C 1/0 AWG191.403 × 10 AWG33.036.6 / 1.442380170300 mRequest this size
Type MC-HL 600V 3/C 2/0 AWG191.403 × 10 AWG35.639.4 / 1.552860195300 mRequest this size
Type MC-HL 600V 3/C 4/0 AWG191.403 × 8 AWG41.745.7 / 1.804195260300 mRequest this size
Type MC-HL 600V 3/C 250 kcmil371.653 × 8 AWG46.050.3 / 1.984910290300 mRequest this size
Type MC-HL 600V 3/C 350 kcmil371.653 × 6 AWG52.156.6 / 2.236640350300 mRequest this size
Type MC-HL 600V 3/C 500 kcmil371.653 × 6 AWG59.464.3 / 2.539120430300 mRequest this size
Type MC-HL 600V 3/C 750 kcmil612.033 × 4 AWG72.978.5 / 3.0913480535300 mRequest this size

Type MC-HL 2000 V (2 kV EPR) Long-Lead PWM VFD Motor Cable Schedule

Type MC-HL 2000 V (2 kV Heavy Corona-Resistant EPR) Long-Run Mill & Slurry-Pump VFD Drive Cable — Dimensional Schedule
Model & GaugePhase Strands2 kV EPR Wall (mm)3 × Symm. GroundsWelded Al OD (mm)Overall OD (mm / in)Approx. Weight (kg/km)Ampacity @90 °C (A)Bulk MOQNext step
Type MC-HL 2kV 3/C 8 AWG191.783 × 14 AWG22.125.1 / 0.9974555300 mRequest this size
Type MC-HL 2kV 3/C 6 AWG191.783 × 12 AWG24.427.7 / 1.0997075300 mRequest this size
Type MC-HL 2kV 3/C 4 AWG191.783 × 12 AWG27.430.7 / 1.21130595300 mRequest this size
Type MC-HL 2kV 3/C 2 AWG191.783 × 10 AWG30.734.3 / 1.351815130300 mRequest this size
Type MC-HL 2kV 3/C 1/0 AWG192.033 × 10 AWG36.340.1 / 1.582620170300 mRequest this size
Type MC-HL 2kV 3/C 2/0 AWG192.033 × 10 AWG38.942.9 / 1.693130195300 mRequest this size
Type MC-HL 2kV 3/C 4/0 AWG372.033 × 8 AWG45.049.3 / 1.944510260300 mRequest this size
Type MC-HL 2kV 3/C 350 kcmil372.413 × 6 AWG56.161.0 / 2.407120350300 mRequest this size
Type MC-HL 2kV 3/C 500 kcmil372.413 × 6 AWG63.568.6 / 2.709680430300 mRequest this size

Ampacities follow NEC Table 310.15(B)(16) for 3 current-carrying copper conductors at +90 °C conductor and +30 °C ambient; include optional 1-pair #16/#14 AWG shielded brake/RTD control pair in the core lay-up on request, and final dimensions are confirmed on the quotation drawing.

Ensure cable gland procurement specifies continuous-corrugated MC-HL compound-filled barrier glands matching the Armor OD and Overall OD columns.

ASCII part references for BOM and ERP entry: TF-MIN-MCHL-VFD, TYPE-MC-HL-600V-4AWG, TYPE-MC-HL-600V-2/0AWG, TYPE-MC-HL-600V-4/0AWG, TYPE-MC-HL-600V-500, TYPE-MC-HL-2KV-2/0AWG, TYPE-MC-HL-2KV-4/0AWG, TYPE-MC-HL-2KV-350.

Standards

Type MC-HL Standards & Weld-Seam Test References

Type MC-HL 600 V & 2 kV Continuous Corrugated Welded Aluminum Armored VFD & Hazardous-Location Mining Cable standards and test references
Standard or specificationApplication
UL 2225 (Construction Reference)Cables and cable-fittings design criteria for continuous-corrugated welded sheath Type MC-HL hazardous-location installations (NRTL listing not claimed).
ICEA S-95-658 / NEMA WC 70600 V and 2000 V cross-linked XLPE and EPR power cable dielectric and physical aging specification.
NEC Articles 501, 502 & 330Hazardous Class I / Class II Division 1 & 2 and industrial tray routing geometry reference.
IEEE 1202 / FT4 & -40 °C Cold ImpactVertical tray flame-retardant and sub-zero cold-bend/impact outer jacket test references.

NFPA 70 (NEC) Articles 330, 501 & 502 Hazardous Location Wiring Reference

ICEA S-95-658 / NEMA WC 70 600 V–2000 V Power Cable Standard

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.