TF-VPT Vacuum Furnace Coaxial Water-Cooled Power Feed-Through & Bulkhead Cable Assembly (VIM / VAR / ESR)
TF-VPT-COAX is a concentric two-pole coaxial water-cooled power cable and custom-machined O-ring vacuum bulkhead assembly (300 MCM to 2,500 MCM / 150 mm² to 1,260 mm², 1,200 A to 9,000 A, 50 Hz to 10 kHz) engineered for Vacuum Induction Melting (VIM), Vacuum Arc Remelting (VAR), Electroslag Remelting (ESR), plasma-hearth and directional-solidification superalloy furnaces where minimal inductive reactance and vacuum-tight chamber pass-through integrity are mandatory.
TF-VPT-COAX coaxial water-cooled power cables and vacuum bulkhead feed-through assemblies (300 MCM to 2,500 MCM / 150 mm² to 1,260 mm², 1,200 A to 9,000 A across 50 Hz to 10 kHz) deliver maximum medium-frequency power throughput into vacuum chambers while eliminating inductive wall heating and chamber-penetration clutter.
Passing separate unipolar forward and return cables through stainless-steel vacuum furnace bulkheads induces strong eddy currents in the chamber shell, wastes kW in reactive voltage drop and doubles the number of vacuum sealing ports. TF-VPT-COAX stacks both electrical polarities coaxially around a central water passage separated by a high-dielectric PTFE/polymer insulating barrier, transitioning seamlessly into precision-machined solid copper O-ring vacuum flanges, bulkhead adapters or plug-sealed induction ports so the external magnetic field self-cancels over the entire span.
Specify TF-VPT-COAX for VIM, VAR, ESR, PAM, electron-beam and crystal-growth vacuum furnaces requiring concentric coaxial bulkhead entry or plug-sealed coaxial leads; choose TF-HC10K / TF-WCCX for open-air medium-frequency induction coils without vacuum bulkhead flanges, or TF-IFL / TF-WCHC for unipolar coreless melting furnaces. Minimum order 1 assembly or 2 pieces (1 pair), manufactured to drawing in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-VPT-COAX Vacuum Coaxial Water-Cooled Assembly Construction
Custom-machined to customer vacuum chamber bulkhead drawings using oxygen-free Cu-HCP copper, PTFE/polymer inter-pole dielectric sleeves and 10 bar hydro-tested hoses.

| Component | Material and construction |
|---|---|
| 1. Concentric Inner & Outer Oxygen-Free Cu-HCP Conductors | High-conductivity fine-stranded inner copper pole around a central coolant bore paired with a symmetrical outer concentric copper return conductor layer for balanced impedance and low AC/DC resistance ratio. |
| 2. High-Dielectric Inter-Pole PTFE / Polymer Insulating Tube | Continuous dielectric separator isolating positive and negative polarities up to 1,500–3,000 V peak coil voltage while maintaining concentricity under tight bending inside furnace enclosures. |
| 3. CNC-Machined O-Ring Vacuum Bulkhead Flange & Stepped Coaxial Terminals | Precision-turned flat sealing faces with concentric Viton/elastomer O-ring grooves, ceramic/PTFE bulkhead insulating collars, vacuum plug terminations and dedicated inlet/outlet cooling ports. |
| 4. Dual-Path Coolant Channels & 15 kV Cord-Reinforced EPDM Outer Hose | Independent or counter-flow water cooling across inner and outer copper poles inside an abrasion- and ozone-resistant non-conductive EPDM hose (6 bar working / 10 bar hydro-test) with non-magnetic 304/316 stainless clamps. |
TF-VPT-COAX Model & Vacuum Bulkhead Code Breakdown
- TF-VPT-COAX: Series identifier for TEBAOFLEX vacuum-chamber coaxial water-cooled power cables and bulkhead assemblies
- 150 to 1260: Nominal copper cross-section per electrical pole in mm² (300 MCM to 2,500 MCM per pole)
- -BF / -VP: Vacuum interface code: Circular O-Ring Bulkhead Flange (-BF) or Machined Vacuum-Plug Coaxial Lead (-VP)
- -PTFE: High-dielectric PTFE/polymer concentric inter-pole insulating separator rated for 1–10 kHz duty
- -AG / -SN: Optional silver-plated (-AG) or tin-plated (-SN) contact blocks and anti-chloride conductor strands
TF-VPT-COAX VIM, VAR, ESR & Crystal-Growth Furnace Applications
Engineered for aerospace superalloy remelting, controlled-atmosphere metallurgy and semiconductor/photovoltaic crystal-growth chambers requiring low-loss vacuum power entry.

- Vacuum Induction Melting (VIM) and Vacuum Induction Precision Casting (VIC) aerospace turbine-blade furnaces.
- Vacuum Arc Remelting (VAR), Electroslag Remelting (ESR) and Plasma Arc Melting (PAM) titanium and nickel-superalloy furnaces.
- Directional Solidification (DS) and Single-Crystal (SX) Equiax investment casting and Electron Beam Furnace (EBF) chambers.
- Controlled-atmosphere Hot Isostatic Press (HIP), vacuum sintering and sapphire/silicon crystal-growth bulkhead power feeds.
TF-VPT-COAX Vacuum Coaxial vs Open-Air MF Coaxial vs Unipolar Leads
| Product Family | Polarity & Reactance | Chamber / Terminal Interface | Primary Furnace Duty |
|---|---|---|---|
| TF-VPT-COAX (this page) | Concentric 2-pole coaxial (ultra-low reactance, zero shell eddy current) | CNC O-ring vacuum bulkhead flange or vacuum-plug coaxial assembly | VIM, VAR, ESR, PAM, EBF, DS/SX superalloy & crystal-growth vacuum furnaces |
| TF-HC10K / TF-WCCX MF Coaxial | Hollow-core enameled Litz or 2-pole open-air coaxial (up to 10 kHz) | Flat copper flags or standard flange terminals (non-vacuum) | Open-air 2–10 kHz induction billet heaters, forging & hardening stations |
| TF-IFL / TF-WCHC Unipolar Leads | Single-pole forward/return pairs (higher loop reactance) | Flat palms, 45°/90° flags or JIC 37° swivel nuts | Coreless air-melt tilting induction furnaces & mains-frequency melters |
| TF-WCP-PIPE Pipe-Connection | Single-pole pipe-coupled (525–1,480 mm²) | Detachable Type D/E pipe-contact ring onto Ø 40–60 mm copper pipes | Polysilicon CVD copper pipe networks & non-vacuum bus transitions |
In vacuum chambers above 500 Hz, switching from twin unipolar pass-throughs to a concentric TF-VPT-COAX coaxial feed-through cuts inductive wall heating and simplifies vacuum sealing to a single bulkhead flange.
TF-VPT-COAX Vacuum Assembly Drawing & RFQ Checklist
- Furnace process type (VIM, VAR, ESR, PAM, EBF, HIP or crystal growth) and chamber vacuum level / atmosphere.
- Operating current (A), voltage (V) and power-supply frequency (50/60 Hz up to 10 kHz).
- Required cable assembly scope: vacuum-plug coaxial cable only, or complete CNC-machined O-ring bulkhead coaxial feed-through assembly.
- Chamber bulkhead flange drawing (flange OD, bolt circle, O-ring groove spec, insulator sleeve length) and internal/external terminal dimensions.
- Cooling water inlet temperature, available supply pressure (bar/PSI), water conductivity (μS/cm) and port thread spec (NPT or G/BSPP).
- Quantity required (MOQ 1 custom assembly or 1 pair, lead time 7 to 45 working days).
Related selection resources
- Compare Open-Air 2 kHz & 10 kHz Hollow-Core Litz & Coaxial Leads
- Compare TF-IFL & TF-WCHC Unipolar Induction & Vacuum Power Leads
- Compare Heavy ESR & SAF Smelting Water-Cooled Furnace Cables
- Compare Steelmaking EAF & LF Water-Cooled Power Cables
- Browse All Water-Cooled & High-Temperature Furnace Cables
TF-VPT-COAX Vacuum Coaxial Water-Cooled Feed-Through FAQ
Why do VIM and VAR vacuum furnaces use TF-VPT-COAX coaxial power assemblies instead of two separate cables?
Concentric coaxial geometry cancels external magnetic fields by 60% to 80%, preventing eddy-current overheating of the stainless-steel vacuum chamber bulkhead, minimizing reactive kVA voltage drop at 500 Hz to 10 kHz, and reducing vacuum leak paths to one circular O-ring flange.
Can TEBAOFLEX manufacture TF-VPT-COAX flanges and stepped coaxial terminals from an existing furnace drawing or worn sample?
Yes. Every TF-VPT-COAX assembly is custom-machined from oxygen-free Cu-HCP copper bar and PTFE/ceramic insulating spacers to match your exact bulkhead bolt pattern, O-ring groove tolerances and coil spacing for 1:1 direct replacement.
How are the positive and negative poles insulated inside a TF-VPT-COAX coaxial water-cooled cable?
A continuous high-dielectric PTFE/polymer insulating separator tube isolates the inner and outer concentric copper poles up to 1,500–3,000 V peak coil voltage, verified by inter-pole isolation testing and micro-ohm resistance inspection before shipment.
What water conductivity and pressure should be maintained on TF-VPT-COAX vacuum furnace circuits?
Use filtered low-conductivity deionized cooling water (typically below 20 μS/cm above 600 V) at 2.5 to 6.0 bar (35 to 87 PSI) inlet pressure with outlet temperatures held below +60 °C (+140 °F); assemblies are hydrostatically factory-tested to 10 bar.
What is the minimum order quantity and delivery lead time for TF-VPT-COAX assemblies?
1 custom-engineered coaxial assembly or 2 pieces (1 matched pair), fabricated strictly to your approved vacuum bulkhead and terminal drawings with a standard lead time of 7 to 45 working days.
TF-VPT-COAX Coaxial Cross-Section, Current & Flow Schedule
TF-VPT-COAX Voltage, Coaxial Span, Flange & MOQ Summary
- Zero-cancellation coaxial inductance: Concentric forward-and-return copper geometry cancels external magnetic fields, cutting reactive voltage drop and adjacent steel-chamber eddy heating
- Precision O-ring vacuum bulkhead flanges: CNC-machined Cu-HCP vacuum flanges and plug-sealed terminals with concentric elastomer O-ring grooves built strictly to chamber drawings
- 50 Hz to 10 kHz superalloy furnace duty: Sized for VIM, VAR, ESR, PAM, electron-beam and DS/SX single-crystal aerospace investment casting furnaces from 1,200 A to 9,000 A
- PTFE/polymer inter-pole isolation: High-dielectric concentric insulation separates positive and negative poles inside a single compact 15 kV outer coolant hose
- 1 assembly or 1 pair custom MOQ: Hydrostatically pressure-tested (10 bar), micro-ohm checked and dielectric-inspected per custom chamber drawing in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 1500 V to 3000 V AC/DC coil operating voltage with 15 kV dielectric outer hose and inter-pole PTFE/polymer isolation |
| Coaxial section and current range | 300 MCM to 2500 MCM per pole (150 mm2 to 1260 mm2), rated 1200 A to 9000 A continuous across 50 Hz to 10 kHz |
| Vacuum interface geometry | Custom CNC-machined Cu-HCP circular O-ring vacuum bulkhead flanges, ceramic/PTFE insulator rings and vacuum-plug induction terminals |
| Coolant pressure and flow check | 6 bar max continuous operating pressure, 10 bar factory hydrostatic test, coolant outlet temperature up to +60 C (+140 F) |
| Minimum order and lead time | 1 custom coaxial assembly or 2 pieces (1 pair) built strictly to vacuum chamber drawing in 7 to 45 working days |
| Inductive reactance advantage | Concentric forward-and-return copper layout reduces loop inductance by 60 to 80 percent compared with side-by-side unipolar leads |
| Factory inspection sequence | Micro-ohm DC resistance, inter-pole high-potential dielectric isolation, coolant flow verification and 10 bar hydrostatic testing |
TF-VPT-COAX (2×150 to 2×1,260 mm²) Vacuum Furnace Coaxial Schedule
| Model & Pole Cross-Section | Imperial Equiv. (per Pole) | Ref. Current at 60 Hz – 1 kHz (A) | Ref. Current at 3 kHz – 10 kHz (A) | Outer Hose Nom. OD (mm) | Min. Coolant Flow (L/min) | Vacuum Interface Option | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-VPT-150 (2×150 mm²) | 300 MCM | 1,200 – 1,800 | 900 – 1,400 | 55 | 10 – 14 | O-Ring Flange / Vacuum Plug | 1 assembly / pair | Request this size |
| TF-VPT-250 (2×250 mm²) | 500 MCM | 2,000 – 2,800 | 1,500 – 2,100 | 68 | 14 – 20 | O-Ring Flange / Vacuum Plug | 1 assembly / pair | Request this size |
| TF-VPT-380 (2×380 mm²) | 750 MCM | 3,000 – 3,800 | 2,200 – 2,900 | 82 | 20 – 28 | O-Ring Flange / Coax Bulkhead | 1 assembly / pair | Request this size |
| TF-VPT-500 (2×500 mm²) | 1,000 MCM | 3,800 – 4,800 | 2,800 – 3,600 | 94 | 26 – 36 | O-Ring Flange / Coax Bulkhead | 1 assembly / pair | Request this size |
| TF-VPT-750 (2×750 mm²) | 1,500 MCM | 5,200 – 6,500 | 3,600 – 4,600 | 112 | 36 – 50 | Heavy Coaxial Vacuum Bulkhead | 1 assembly / pair | Request this size |
| TF-VPT-1000 (2×1,000 mm²) | 2,000 MCM | 6,500 – 7,800 | 4,400 – 5,400 | 128 | 48 – 64 | Heavy Coaxial Vacuum Bulkhead | 1 assembly / pair | Request this size |
| TF-VPT-1260 (2×1,260 mm²) | 2,500 MCM | 7,800 – 9,000 | 5,000 – 6,200 | 145 | 60 – 80 | Custom VAR/ESR Coax Assembly | 1 assembly / pair | Request this size |
Because vacuum chamber port diameters, bolt patterns, elastomer O-ring groove tolerances and internal crucible coil spacing vary across VIM, VAR, ESR and HIP furnace OEMs, all TF-VPT-COAX flange dimensions, vacuum-sealing collars and step-back coaxial terminals are CNC-machined strictly to approved customer drawings.
ASCII part references for BOM and ERP entry: TF-VPT-150, TF-VPT-250, TF-VPT-380, TF-VPT-500, TF-VPT-750, TF-VPT-1000, TF-VPT-1260.
TF-VPT-COAX Reference Copper & Vacuum Sealing Standards
| Standard or specification | Application |
|---|---|
| ASTM B187 / DIN EN 13601 (Oxygen-Free Cu-HCP) | High-purity oxygen-free copper for vacuum-tight machined bulkhead flanges, stepped coaxial blocks and low-outgassing conductors. |
| ISO 3601 (O-Ring Groove Geometry) & High-Potential / Hydrostatic Factory Testing | Precision flat flange faces and concentric O-ring grooves inspected alongside micro-ohm resistance, inter-pole isolation and 10 bar water-pressure testing. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and coaxial dielectric / hydrostatic inspection
ASTM B187 — Standard Specification for Copper Bar, Bus Bar, Rod and Shapes
ISO 3601-2 — Fluid Power Systems: O-Rings Housing Dimensions for General Applications
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-WCP Pipe-Connection Water-Cooled High-Current & Hollow-Core Cable — Type E / Type D Copper Pipe Coupling (300–1,480 mm²)
A related cable option for a different application or duty profile.
View productTF-BT Water-Cooled Rigid Copper Bus Tube & Furnace Transformer Delta Closure System (Ø 40–168 mm / 5–120 kA)
A related cable option for a different application or duty profile.
View productTF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.