TF-WCIH is a heavy-duty internally water-cooled flexible induction heating coil cable engineered for weld preheating, post-weld heat treatment (PWHT), shrink-fitting and stress relieving on large stationary steel pipelines, pressure vessels and turbine casings up to +1,200 °C workpiece temperature. Rated 1,000 V and up to 1,500 A—three times the current capacity of air-cooled PWHT coils—TF-WCIH combines individually insulated HF-stranded copper wire inside a rugged Ø 24 mm silicone-para-aramid pressure hose (7 bar max, >= 5 L/min, +200 °C continuous hose rating) in 10 m, 15 m or custom lengths.

Product information
SKU
TF-WCIH-1500A
Brand
TEBAOFLEX
Product overview

TF-WCIH water-cooled flexible induction heating and PWHT coil cables (1,000 V, up to 1,500 A continuous current, Ø 24 mm outer diameter, +200 °C continuous cable temperature for stationary workpieces up to +1,200 °C) deliver rapid, high-power electromagnetic heating for heavy-wall pipeline girth welds, refinery reactors, boiler drums, offshore monopiles and steam turbine casings.

While air-cooled induction heating blankets and flexible air-cooled Litz cables top out around 400 A to 550 A and soak up severe radiant heat on thick-wall chrome-molybdenum (P91/P22) welds above 650 °C, TF-WCIH pumps >= 5 L/min of cooling water at up to 7 bar directly through the core of an individually insulated HF-stranded copper Litz conductor encased in a flexible silicone-para-aramid reinforced hose. Because heat is extracted continuously along the entire 10 m or 15 m coil length, contractors achieve faster ramp-up rates, tighter circumferential temperature uniformity and longer coil service life without bulky rigid water-cooled copper tube inductors.

Specify TF-WCIH when weld preheat, PWHT, coating removal or shrink-fit jobs demand 800 A to 1,500 A or workpiece temperatures from +600 °C to +1,200 °C; specify TF-ACIH air-cooled induction cable (350–600 A) for lightweight 35–40 kW portable field units without a water chiller. Minimum order 1 coil assembly, delivered in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-WCIH HF Litz Copper & Silicone-Aramid Hose Construction

Combines individually insulated high-frequency copper Litz stranding with an internal coolant flow passage and a flexible Ø 24 mm para-aramid reinforced silicone pressure hose.

Clean 2D circular technical cross-section of TF-WCIH Ø 24 mm water-cooled induction heating coil cable showing central water bore, densely packed individually insulated fine copper HF Litz strands, inner silicone liner, para-aramid reinforcement braid and terracotta-red outer silicone pressure hose
Internally cooled HF Litz cross-section: radial cooling water extracts 1,500 A I²R heat directly from individually insulated copper wires.
TF-WCIH 1,000 V / 1,500 A Water-Cooled Flexible Induction Heating & PWHT Coil Cable (Ø 24 mm Silicone-Aramid Hose, +1,200 °C Workpiece) construction
ComponentMaterial and construction
1. Individually Insulated HF-Stranded Copper Litz ConductorHundreds of fine individually insulated copper wires arranged in high-frequency Litz stranding around the central cooling bore to minimize 5–25 kHz AC skin-effect losses.
2. Internal Water-Cooling Channel (>= 5 L/min, 7 bar Rated)Continuous unobstructed flow path running end-to-end across 10 m, 15 m or custom lengths so coolant cools both copper strands and hose inner wall simultaneously.
3. Ø 24 mm Silicone-Para-Aramid Reinforced Pressure HoseSmooth flexible +200 °C silicone elastomer hose reinforced with high-tensile para-aramid fiber braid to resist 7 bar internal pressure, tight pipe wrapping and mechanical jobsite abrasion.
4. Water-Cooled High-Current Quick-Plug or Custom OEM TerminalsFitted with combined electrical-and-water high-current plugs, quick-disconnect cam couplings or customer-specified induction power-source adapters (ring lugs optional on custom transitions).

TF-WCIH Water-Cooled Induction Coil Code Breakdown

  • TF-WCIH: Series identifier: TEBAOFLEX Water-Cooled Induction Heating & PWHT flexible coil cable
  • 1500: Maximum continuous current rating in amperes (1,500 A at 1,000 V AC/HF)
  • 5M to 25M: Finished coil assembly length in meters (standard 10 m and 15 m, custom lengths available)
  • -PLUG / -CUST: End-termination suffix: standard water-cooled quick plug (-PLUG) or customer OEM coupling (-CUST)
  • Ø 24 mm: Silicone-para-aramid pressure hose outer diameter rated 7 bar working pressure and +200 °C continuous
Applications

TF-WCIH Pipeline PWHT, Pressure Vessel & Shrink-Fit Applications

Built for high-power mobile and shop induction heating contractors serving oil & gas refineries, power generation plants, heavy fabrication yards and shipbuilding.

Heavy industrial steel refinery pipeline weld joint undergoing post-weld heat treatment wrapped tightly in multiple turns of terracotta-red TF-WCIH water-cooled flexible induction heating coil cable over ceramic thermal blanket
Heavy-wall pipeline weld preheating and PWHT using flexible terracotta-red TF-WCIH water-cooled induction coil cables over ceramic thermal insulation.
  • Heavy-wall refinery pipeline, boiler header and P91/P22 alloy weld preheating and post-weld heat treatment (PWHT) up to +1,200 °C workpiece temperature.
  • Pressure vessel, heat-exchanger shell, wind-monopile flange and offshore jacket structural weld stress relieving.
  • Large steam/gas turbine rotor, gear ring and bearing-housing thermal shrink-fitting and disassembly.
  • High-power stationary forging, bending and localized annealing on balanced non-moving steel assemblies.

TF-WCIH Water-Cooled Coil vs Air-Cooled PWHT Cable vs Coaxial Feeder

TF-WCIH Water-Cooled Induction Coil vs TF-ACIH Air-Cooled Induction Cable vs WC-2C-LR Furnace Feeder
Induction Cable TypeMax Current & CoolingOD & Length FormatPrimary Industrial Duty
TF-WCIH Water-Cooled PWHT Coil (this page)1,500 A / 1,000 V; internal water (>= 5 L/min, 7 bar)Ø 24 mm silicone-aramid; 5–25 m wrap coilsHeavy-wall pipe/vessel preheat, PWHT (+1,200 °C workpiece) & shrink-fit
TF-ACIH Air-Cooled Induction Cable350–600 A / 1,000 V; passive air (+450 °C cable)Ø 20 mm stainless-braided Litz; bulk/coilsPortable 35–40 kW field preheat & PWHT where no water chiller is available
WC-2C-LR Water-Cooled Coaxial Lead1.6–11.5 kA / 3,000 V; 0.04–0.08 µH/m coaxialØ 38–84 mm rubber hose; 1.5–12 m feedersInverter-to-furnace low-reactance feeders for melting & billet heating
TF-IFL Induction Melting Power Lead70–2,500 MCM single-pole; JIC 37° / flat palmØ 25–115 mm; custom short catenary leadsCoreless tilting foundry induction melting furnaces

Use TF-WCIH as the actual flexible wrap-around heating coil on high-mass stationary steel joints; use WC-2C-LR to deliver low-inductance power from the inverter cabinet to the workhead.

TF-WCIH Water-Cooled Induction Heating Coil Cable RFQ Checklist

  • Induction power-source output rating (kW, frequency kHz, max current up to 1,500 A and max voltage up to 1,000 V).
  • Required coil length (standard 10 m or 15 m, or custom 5–25 m) and workpiece diameter / minimum wrap radius.
  • Target workpiece heating temperature (up to +1,200 °C) and ceramic insulation blanket thickness.
  • Power-source end connector interface: standard high-current water-cooled quick plug, threaded hydraulic union or OEM-specific plug drawing/photos.
  • Chiller water supply pressure (up to 7 bar) and flow capacity (>= 5 L/min).
  • Quantity required (MOQ 1 coil assembly, delivery 7 to 45 working days).

Related selection resources

TF-WCIH 1,500 A Water-Cooled Induction Heating Coil Cable FAQ

Why choose TF-WCIH water-cooled induction coil cable over an air-cooled PWHT cable?

3× higher current capacity: TF-WCIH carries up to 1,500 A continuously at 1,000 V versus 400–550 A for air-cooled induction cables, enabling rapid weld preheating and +1,200 °C PWHT on thick-wall refinery pipes, boiler drums and turbine casings without overheating the coil.

Can TF-WCIH be wrapped directly onto bare +1,200 °C glowing steel without insulation?

No. Always place a ceramic-fiber thermal blanket between the glowing steel workpiece (up to +1,200 °C) and TF-WCIH so the Ø 24 mm silicone-para-aramid outer hose stays within its +200 °C continuous temperature rating.

What water flow and pressure does TF-WCIH require during 1,500 A heating cycles?

At least 5 L/min of clean cooling water at up to 7 bar maximum working pressure for 10 m and 15 m coils (6–7 L/min for 20–25 m coils), interlocked with a flow switch on the induction inverter.

Can TEBAOFLEX fit TF-WCIH with custom plugs matching our existing European or North American induction heater?

Yes. Send photos or dimensional drawings of your induction power unit's water-cooled output sockets and we will custom-machine or assemble compatible high-current plugs before hydrostatic testing.

What is the minimum order quantity and standard lead time for TF-WCIH coils?

1 complete water-cooled induction heating coil assembly (standard 10 m or 15 m, or custom 5–25 m length), manufactured and pressure-tested in 7 to 45 working days.

Specifications

TF-WCIH Standard 5 m–25 m Water-Cooled Coil Schedule

TF-WCIH Current, Workpiece Temp, Flow & Hose Pressure Summary

  • 1,500 A & 1,000 V continuous duty: Internal water cooling triples current capacity versus 400–550 A air-cooled induction coils for thick-wall refinery pipes and heavy pressure vessels
  • Up to +1,200 °C workpiece temperature: Wraps directly over ceramic thermal blankets on glowing welds while forced coolant holds cable jacket temperature within its +200 °C envelope
  • Ø 24 mm silicone-para-aramid hose: High-flexibility para-aramid fiber reinforced silicone pressure jacket rated 7 bar working pressure and >= 5 L/min cooling flow without kinking
  • Individually insulated HF-stranded copper: Enamel/film-insulated fine copper Litz stranding suppresses 5–25 kHz skin and proximity eddy losses along 10 m to 15 m wrapped coil turns
  • 1 coil assembly custom MOQ: Supplied in 10 m (6 kg), 15 m (10 kg) or custom lengths with factory-fitted high-current water-cooled quick plugs or custom OEM couplings in 7 to 45 working days
TF-WCIH 1,000 V / 1,500 A Water-Cooled Flexible Induction Heating & PWHT Coil Cable (Ø 24 mm Silicone-Aramid Hose, +1,200 °C Workpiece) technical data
ParameterValue
Rated voltage1,000 V operating voltage and 1,500 A continuous AC/HF current (5 to 25 kHz portable and stationary induction inverters)
Workpiece and cable temperature limitsWorkpiece up to +1,200 °C (over ceramic insulation blanket); continuous cable hose rating up to +200 °C
Cooling pressure and minimum flowMaximum 7 bar (0.7 MPa) continuous water pressure; minimum 5 L/min cooling water flow per coil
Conductor and hose constructionIndividually insulated HF-stranded copper Litz wire inside Ø 24 mm silicone-para-aramid reinforced hose
Standard coil lengths and weights10 m standard coil (approx. 6 kg dry) and 15 m standard coil (approx. 10 kg dry); custom 5 to 25 m lengths on request
Minimum order and lead time1 piece (1 complete water-cooled induction coil assembly) built with custom power-source plugs in 7 to 45 working days

TF-WCIH Standard Water-Cooled Induction Coil Configurations

TF-WCIH 1,000 V / 1,500 A Water-Cooled Induction Heating & PWHT Coil Cable Standard Assemblies
Model CodeCoil Length (m)Max Current / VoltageHose OD (mm)Max Workpiece / Cable TempMin. Flow / Max PressureApprox. Dry Weight (kg)Next step
TF-WCIH-1500-5M5.01,500 A / 1,000 V24.0+1,200 °C / +200 °C5 L/min / 7 bar3.2Request this size
TF-WCIH-1500-10M10.01,500 A / 1,000 V24.0+1,200 °C / +200 °C5 L/min / 7 bar6.0Request this size
TF-WCIH-1500-15M15.01,500 A / 1,000 V24.0+1,200 °C / +200 °C5 L/min / 7 bar10.0Request this size
TF-WCIH-1500-20M20.01,500 A / 1,000 V24.0+1,200 °C / +200 °C6 L/min / 7 bar13.2Request this size
TF-WCIH-1500-25M25.01,500 A / 1,000 V24.0+1,200 °C / +200 °C7 L/min / 7 bar16.5Request this size

Always separate TF-WCIH from direct contact with glowing > +200 °C steel surfaces using ceramic-fiber insulation blankets (typically 13–25 mm thick), and maintain closed-loop chiller flow >= 5 L/min with flow-interlock protection on the induction power source.

ASCII part references for BOM and ERP entry: TF-WCIH-1500-5M, TF-WCIH-1500-10M, TF-WCIH-1500-15M, TF-WCIH-1500-20M, TF-WCIH-1500-25M.

Standards

TF-WCIH Reference Induction Safety & Pressure Test Standards

TF-WCIH 1,000 V / 1,500 A Water-Cooled Flexible Induction Heating & PWHT Coil Cable (Ø 24 mm Silicone-Aramid Hose, +1,200 °C Workpiece) standards and test references
Standard or specificationApplication
IEC 60519-3 & EN 60519-3Electroheat installation safety design reference for flexible induction heating work coils and water-cooled power leads.
100% Factory 10 bar Hydrostatic & Continuity InspectionEvery TF-WCIH silicone-para-aramid hose and high-current plug coupling is hydrostatically proof-tested and resistance-verified under ISO 9001:2015 manufacturing.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and hydrostatic pressure verification

IEC 60519-3 — Safety in Electroheat Installations: Induction Heating Equipment

DIN EN 60519-3 — Particular Requirements for Induction and Conduction Heating Installations

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.