High Temperature Cables TEBAOFLEX

WC-2C-LR Low-Reactance Water-Cooled Two-Conductor Coaxial Induction Cable (IEC 60519-3, 50 Hz–50 kHz, 2×95–2×630 mm² & 300–6,000 MCM)

WC-2C-LR is a low-reactance water-cooled two-conductor coaxial and interleaved induction power cable designed to IEC 60519-3, VDE 0721 and JB/T 6314 for 50 Hz to 50 kHz operation (800 V to 3,000 V AC rms, 6–10 kV inter-conductor dielectric test). Housing both Go (+I) and Return (-I) copper conductors concentrically inside a single water-cooled hose cuts loop inductance to 0.04–0.08 µH/m (75–85% below paired single-core leads) across metric 2×95 to 2×630 mm² (1.6–11.5 kA) and imperial 300 to 6,000 MCM (1,400–28,300 A @ 60 Hz).

Product information
SKU
WC-2C-LR-95-630
Brand
TEBAOFLEX
Product overview

WC-2C-LR low-reactance water-cooled two-conductor coaxial induction cables (50 Hz to 50 kHz, 800 V to 3,000 V AC rms, metric 2×95 to 2×630 mm² delivering 1.6 kA to 11.5 kA and North American 300 to 6,000 MCM delivering 1,400 A to 28,300 A at 60 Hz or 600 A to 4,350 A at 3,000 Hz) integrate both the Go (+I) and Return (-I) high-current conductors concentrically inside a single water-cooled flexible rubber hose.

In medium- and high-frequency induction furnaces, billet heaters, seam-welded tube mills and crystal pullers, running two separate single-core water-cooled leads generates large stray magnetic loops that waste inverter kVA in inductive voltage drop and whip cables violently during power pulsing. WC-2C-LR cancels opposing magnetic fields directly within one compact assembly, lowering loop inductance per unit length to 0.04–0.08 µH/m—a 75% to 85% reduction—while maintaining 6.0 kV to 10.0 kV AC rms inter-conductor dielectric strength via a dedicated high-dielectric barrier hose and separator tapes.

Specify WC-2C-LR for open-air low-reactance tilting induction melting furnaces, 1–50 kHz induction hardening/forging/brazing coils and high-power foundry feeders; specify TF-VPT-COAX when a CNC O-ring vacuum chamber bulkhead flange is required, or TF-HC10K for single-pole hollow-core Litz feeders. Minimum order 1 assembly or 1 matched pair, manufactured in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

WC-2C-LR Concentric Go/Return Coaxial Water-Cooled Construction

Engineered to IEC 60519-3, VDE 0721 and JB/T 6314 with concentric/interleaved fine-stranded copper polarity rings separated by a 6–10 kV dielectric water barrier hose.

Clean 2D circular technical cross-section of WC-2C-LR two-conductor coaxial water-cooled cable showing central coolant channel, inner Go copper conductor ring, off-white high-dielectric inter-conductor barrier hose, outer Return copper conductor ring and matte black outer cooling hose
Concentric coaxial cross-section: symmetrical Go/Return copper rings cancel external magnetic flux to deliver 0.04–0.08 µH/m loop inductance.
WC-2C-LR Low-Reactance Water-Cooled Two-Conductor Coaxial Induction Cable (IEC 60519-3, 50 Hz–50 kHz, 2×95–2×630 mm² & 300–6,000 MCM) construction
ComponentMaterial and construction
1. Central Cooling-Water Passage & Inner Go (+I) Fine-Stranded Copper ConductorOpen central coolant bore surrounded by soft-annealed electrolytic copper fine-wire ropes forming the inner Go (+I) polarity with uniform forced-water heat extraction.
2. High-Dielectric Inter-Conductor Barrier Hose & Separator TapesPrecision extruded insulating elastomer barrier tube plus multi-layer separator tapes providing 6.0 kV to 10.0 kV AC rms (50 Hz, 1 min) withstand between Go and Return conductors.
3. Concentric / Interleaved Outer Return (-I) Copper Conductor RingBalanced outer ring of fine-stranded copper bundles surrounding the barrier hose to cancel external magnetic flux and suppress loop inductance to 0.04–0.08 µH/m.
4. Abrasion-Resistant Non-Conductive Outer Water Hose & Split Coaxial TerminalsFiber-reinforced high-dielectric rubber outer cooling hose (0.4–0.6 MPa working, 1.0–1.2 MPa routine hydrostatic test; optional thermal fiberglass sleeve) terminating in CNC-machined coaxial split-palm or stud connectors.

WC-2C-LR Metric & Imperial Model Code Breakdown

  • WC-2C-LR: Series code: Water-Cooled (WC) Two-Conductor Coaxial (2C) Low-Reactance (LR) induction power cable
  • 2x95 to 2x630: Metric Go + Return copper cross-section in mm² (1.6 kA to 11.5 kA, 12–52 L/min deionized water)
  • 300MCM to 6000MCM: North American imperial conductor size option (1,400–28,300 A @ 60 Hz; 600–4,350 A @ 3,000 Hz)
  • -THG: Optional woven fiberglass radiant-heat & molten-metal splash protective outer sleeve
  • 1.5m–12m: Exact custom pin-to-pin overall assembly length with customer split-palm spacing and NPT/BSPP water ports
Applications

WC-2C-LR Coreless Induction Melting, Forging & HF Heating Applications

Designed for low-reactance, zero-whip power transfer across medium-frequency and high-frequency induction melting, heating and thermal processing lines.

Modern foundry coreless medium-frequency induction melting furnace bay equipped with curved black WC-2C-LR water-cooled coaxial power cables linking the power supply bus enclosure to the tilting furnace coil
Coreless tilting induction melting furnace fed by low-reactance WC-2C-LR coaxial water-cooled cables for minimal voltage drop and zero cable whip.
  • Coreless tilting induction melting furnaces (foundry iron, steel, aluminum and copper alloys) operating from 50 Hz to 4 kHz at 5.5–11.5 kA.
  • 1–50 kHz HF/MF induction billet forging heaters, seam-welded pipe mills, hardening stations, brazing fixtures and crystal-pulling coils.
  • High-current North American 60 Hz–3,000 Hz industrial induction power supplies sized in 300–6,000 MCM pair-foot impedance ratings.
  • Long-reach flexible transformer-to-workhead induction leads requiring minimal voltage drop and zero electromagnetic cable kick.

WC-2C-LR Coaxial vs Vacuum Bulkhead vs Hollow-Core vs PWHT Coil Leads

WC-2C-LR Open-Air Coaxial vs TF-VPT Vacuum Bulkhead Coaxial vs TF-HC10K Single-Pole Hollow-Core vs Paired Single-Core Leads
Cable ArchitectureLoop Inductance & PolarityFrequency & Current SpanBest Furnace Application
WC-2C-LR Two-Conductor Coaxial (this page)0.04–0.08 µH/m (Go + Return in 1 hose, -75–85% L')50 Hz–50 kHz; 2×95–2×630 mm² & 300–6,000 MCMTilting coreless induction melting, billet forging, tube welding & hardening
TF-VPT-COAX Vacuum Bulkhead CoaxialConcentric coaxial + CNC O-ring chamber flange1–10 kHz; 2×150–2×1,260 mm²VIM, VAR, ESR & crystal-growth vacuum chamber wall feed-throughs
TF-HC10K / TF-HC2K Hollow-Core LitzSingle-pole per cable (paired externally)2 kHz–10 kHz; 70–1,015 mm²Multi-turn MF heating circuits with separate go/return bus terminations
TF-WCIH Water-Cooled PWHT Coil CableØ 24 mm flexible wrap-around heating coil1,000 V / 1,500 A; +1,200 °C workpieceRefinery pipe welds, pressure vessels & stationary field PWHT

Whenever induction inverter voltage drop or electromagnetic cable whipping limits melt rate, replacing two parallel single-core cables with one WC-2C-LR coaxial assembly immediately slashes loop reactance.

WC-2C-LR Water-Cooled Two-Conductor Coaxial Cable RFQ Checklist

  • Operating frequency (50 Hz to 50 kHz), RMS current (kA), inverter output voltage (800–3,000 V AC) and duty cycle.
  • Preferred standard: Metric WC-2C-LR (2×95 to 2×630 mm²) or North American Imperial (300–6,000 MCM).
  • Exact pin-to-pin assembly length (1.5 m to 12 m) and hydraulic tilt / minimum bending radius constraints.
  • Terminal geometry on inverter and coil ends: split-palm spacing, bolt-hole pattern, busbar ridge clearance and water port thread (NPT / G / BSPP).
  • Cooling water inlet temperature, available flow rate (L/min or GPM), conductivity (µS/cm) and optional thermal fiberglass splash sleeve.
  • Order quantity (MOQ 1 piece or 1 pair, standard manufacturing lead time 7 to 45 working days).

Related selection resources

WC-2C-LR Water-Cooled Two-Conductor Coaxial Cable FAQ

How much inductance does WC-2C-LR save compared to two separate single-core water-cooled cables?

75% to 85% lower loop inductance: housing Go (+I) and Return (-I) copper conductors concentrically inside one water-cooled hose drops inductance to 0.04–0.08 µH/m, cutting reactive voltage drop and eliminating violent electromagnetic cable whipping.

What inter-conductor voltage and hydrostatic tests does WC-2C-LR pass before shipment?

6.0 kV to 10.0 kV AC rms (50 Hz, 1 minute) inter-conductor dielectric withstand across the internal barrier hose, plus 1.0 to 1.2 MPa (10–12 bar) routine hydrostatic pressure testing against a 0.4–0.6 MPa working rating.

Can WC-2C-LR be built to North American 300–6,000 MCM dimensions as well as metric 2×95–2×630 mm²?

Yes. We manufacture both IEC metric WC-2C-LR sizes (2×95 to 2×630 mm², 1.6–11.5 kA) and imperial 300–6,000 MCM two-conductor coaxial leads (up to 28,300 A at 60 Hz and 4,350 A at 3,000 Hz) with custom copper palms and NPT or BSPP coolant ports.

What coolant water conductivity is required for WC-2C-LR above 800 V AC?

Maintain closed-loop deionized water conductivity at or below 50 µS/cm (ideally <= 20–30 µS/cm above 1,500 V) with inlet <= 35 °C and outlet <= 55 °C, preventing electrolytic corrosion across the coaxial split terminals.

What is the minimum order quantity and delivery time for WC-2C-LR coaxial assemblies?

1 custom coaxial cable assembly or 1 matched pair, engineered to exact pin-to-pin length (1.5–12 m) and terminal drawing in 7 to 45 working days.

Specifications

WC-2C-LR Metric (2×95–2×630 mm²) & Imperial (300–6,000 MCM) Schedules

WC-2C-LR Frequency, Inductance, Dielectric & Coolant Summary

  • 0.04–0.08 µH/m ultra-low loop inductance: Concentric Go (+I) and Return (-I) polarity cancellation reduces inductive reactance by 75–85% versus two separate single-core water-cooled cables
  • 50 Hz to 50 kHz & 800–3,000 V AC: High-dielectric inter-conductor barrier hose withstands 6.0–10.0 kV AC rms (50 Hz, 1 min) between go and return poles for HF/MF inverters
  • Metric 2×95–2×630 mm² & 300–6,000 MCM: Covers both European/IEC metric sizes (1.6–11.5 kA, 12–52 L/min) and North American pair-foot imperial sizes (up to 28,300 A @ 60 Hz / 4,350 A @ 3 kHz)
  • 1.0–1.2 MPa routine hydrostatic test: Rated 0.4–0.6 MPa continuous working pressure (up to 80 PSI / 5.5 bar imperial), 8.5× OD dynamic furnace-tilt bend radius, 1.5–12 m custom lengths
  • 1 piece or 1 pair custom assembly MOQ: Built to customer copper palm hole pattern, coaxial split-end spacing and water port threads under ISO 9001:2015 manufacturing in 7 to 45 working days
WC-2C-LR Low-Reactance Water-Cooled Two-Conductor Coaxial Induction Cable (IEC 60519-3, 50 Hz–50 kHz, 2×95–2×630 mm² & 300–6,000 MCM) technical data
ParameterValue
Rated voltage800 V to 3,000 V AC rms (50 Hz to 50 kHz operating band; 6.0 to 10.0 kV AC rms 1 min inter-conductor dielectric test)
Loop inductance per unit length0.04 to 0.08 µH/m (75% to 85% lower inductive reactance than two separate single-core water-cooled leads)
Metric and imperial size rangeMetric 2×95 to 2×630 mm² (1.6 to 11.5 kA); Imperial 300 to 6,000 MCM (1,400 to 28,300 A at 60 Hz; 600 to 4,350 A at 3,000 Hz)
Coolant flow, chemistry and pressure12 to 52 L/min deionized water (up to 50 µS/cm, inlet up to 35 °C, outlet up to 55 °C); 0.4 to 0.6 MPa working, 1.0 to 1.2 MPa routine hydro test
Dynamic bending radius and length8.5 × outer hose OD during hydraulic furnace pouring tilt; manufactured to exact pin-to-pin lengths from 1.5 m to 12 m
Minimum order and lead time1 piece or 1 matched pair custom coaxial assembly built to terminal drawing in 7 to 45 working days

WC-2C-LR Metric Coaxial Schedule (2×95–2×630 mm²)

WC-2C-LR Metric Water-Cooled Two-Conductor Coaxial Induction Cable Schedule (IEC 60519-3, 2×95 to 2×630 mm²)
Order DesignationGo + Return Area (mm²)Voltage & FrequencyApprox. Hose OD (mm)Rated Current (kA)Water Flow (L/min)Min. Bend R (mm)Next step
WC-2C-LR-2x952×95 (Go & Return)1.5 kV · 1–50 kHz38.01.612320Request this size
WC-2C-LR-2x1502×150 (Go & Return)1.5 kV · 1–50 kHz45.02.516380Request this size
WC-2C-LR-2x2402×240 (Go & Return)2.0 kV · 0.5–10 kHz54.04.022460Request this size
WC-2C-LR-2x3202×320 (Go & Return)2.5 kV · 0.25–4 kHz62.05.528530Request this size
WC-2C-LR-2x4002×400 (Go & Return)3.0 kV · 0.1–3 kHz68.07.034580Request this size
WC-2C-LR-2x5002×500 (Go & Return)3.0 kV · 0.05–2 kHz75.09.042650Request this size
WC-2C-LR-2x6302×630 (Go & Return)3.0 kV · 0.05–1 kHz84.011.552720Request this size

WC-2C-LR Imperial 300–6,000 MCM Coaxial Sizing Reference

WC-2C-LR North American Imperial Two-Conductor Coaxial Reference (300–6,000 MCM — 60 Hz & 3,000 Hz Pair-Foot Impedance)
Model & Imperial SizeOD (in)Min. Bend Dia (in)60 Hz Current (A)60 Hz Rac / Z (μΩ/pair-ft)3,000 Hz Current (A)3,000 Hz Rac / Z (μΩ/pair-ft)Next step
WC-2C-LR-300MCM (300 MCM)2.62211,40077 / 76600187 / 1,035Request this size
WC-2C-LR-1000MCM (1,000 MCM)3.62294,70023 / 271,17588 / 726Request this size
WC-2C-LR-1500MCM (1,500 MCM)5.00407,00016 / 231,29087 / 828Request this size
WC-2C-LR-2000MCM (2,000 MCM)5.50449,40012 / 211,59071 / 829Request this size
WC-2C-LR-2500MCM (2,500 MCM)5.504411,70011 / 192,02058 / 785Request this size
WC-2C-LR-3000MCM (3,000 MCM)6.004814,1009 / 182,54050 / 797Request this size
WC-2C-LR-4000MCM (4,000 MCM)6.004818,8007 / 162,80047 / 725Request this size
WC-2C-LR-6000MCM (6,000 MCM)7.506028,3006 / 184,35039 / 830Request this size

Imperial sizing equations (pair-foot = 1 ft Go + 1 ft Return): Power Loss (W) = I² × Rac × L; Voltage Drop (V) = I × Z × L; Min Water Flow (GPM at 30 °F ΔT) = Power Loss / 4,410 (minimum design flow >= 2 GPM; max water inlet 90 °F / 32 °C, max outlet 150 °F / 65 °C, max pressure 80 PSI).

ASCII part references for BOM and ERP entry: WC-2C-LR-2x95, WC-2C-LR-2x150, WC-2C-LR-2x240, WC-2C-LR-2x320, WC-2C-LR-2x400, WC-2C-LR-2x500, WC-2C-LR-2x630, WC-2C-LR-300MCM to WC-2C-LR-6000MCM.

Standards

WC-2C-LR Reference Induction Heating & Testing Standards

WC-2C-LR Low-Reactance Water-Cooled Two-Conductor Coaxial Induction Cable (IEC 60519-3, 50 Hz–50 kHz, 2×95–2×630 mm² & 300–6,000 MCM) standards and test references
Standard or specificationApplication
IEC 60519-3 & DIN VDE 0721Safety in electroheat and electromagnetic processing installations — particular requirements for induction and conduction heating and induction melting (design and manufacturing basis; not a third-party listing).
JB/T 6314 & ISO 9001:2015 Workshop VerificationWater-cooled furnace cable construction reference with 100% routine 6–10 kV AC inter-conductor dielectric withstand and 1.0–1.2 MPa hydrostatic pressure verification prior to dispatch.

Certifications and document support

TEBAOFLEX ISO 9001:2015 manufacturing and 1.0 MPa hydrostatic test records

IEC 60519-3 — Safety in Electroheat Installations: Induction and Conduction Heating & Melting

DIN EN 60519-3 (VDE 0721) — Particular Requirements for Induction Heating & Melting

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.