WC-2C-LR Low-Reactance Water-Cooled Two-Conductor Coaxial Induction Cable (IEC 60519-3, 50 Hz–50 kHz, 2×95–2×630 mm² & 300–6,000 MCM)
WC-2C-LR is a low-reactance water-cooled two-conductor coaxial and interleaved induction power cable designed to IEC 60519-3, VDE 0721 and JB/T 6314 for 50 Hz to 50 kHz operation (800 V to 3,000 V AC rms, 6–10 kV inter-conductor dielectric test). Housing both Go (+I) and Return (-I) copper conductors concentrically inside a single water-cooled hose cuts loop inductance to 0.04–0.08 µH/m (75–85% below paired single-core leads) across metric 2×95 to 2×630 mm² (1.6–11.5 kA) and imperial 300 to 6,000 MCM (1,400–28,300 A @ 60 Hz).
WC-2C-LR low-reactance water-cooled two-conductor coaxial induction cables (50 Hz to 50 kHz, 800 V to 3,000 V AC rms, metric 2×95 to 2×630 mm² delivering 1.6 kA to 11.5 kA and North American 300 to 6,000 MCM delivering 1,400 A to 28,300 A at 60 Hz or 600 A to 4,350 A at 3,000 Hz) integrate both the Go (+I) and Return (-I) high-current conductors concentrically inside a single water-cooled flexible rubber hose.
In medium- and high-frequency induction furnaces, billet heaters, seam-welded tube mills and crystal pullers, running two separate single-core water-cooled leads generates large stray magnetic loops that waste inverter kVA in inductive voltage drop and whip cables violently during power pulsing. WC-2C-LR cancels opposing magnetic fields directly within one compact assembly, lowering loop inductance per unit length to 0.04–0.08 µH/m—a 75% to 85% reduction—while maintaining 6.0 kV to 10.0 kV AC rms inter-conductor dielectric strength via a dedicated high-dielectric barrier hose and separator tapes.
Specify WC-2C-LR for open-air low-reactance tilting induction melting furnaces, 1–50 kHz induction hardening/forging/brazing coils and high-power foundry feeders; specify TF-VPT-COAX when a CNC O-ring vacuum chamber bulkhead flange is required, or TF-HC10K for single-pole hollow-core Litz feeders. Minimum order 1 assembly or 1 matched pair, manufactured in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
WC-2C-LR Concentric Go/Return Coaxial Water-Cooled Construction
Engineered to IEC 60519-3, VDE 0721 and JB/T 6314 with concentric/interleaved fine-stranded copper polarity rings separated by a 6–10 kV dielectric water barrier hose.

| Component | Material and construction |
|---|---|
| 1. Central Cooling-Water Passage & Inner Go (+I) Fine-Stranded Copper Conductor | Open central coolant bore surrounded by soft-annealed electrolytic copper fine-wire ropes forming the inner Go (+I) polarity with uniform forced-water heat extraction. |
| 2. High-Dielectric Inter-Conductor Barrier Hose & Separator Tapes | Precision extruded insulating elastomer barrier tube plus multi-layer separator tapes providing 6.0 kV to 10.0 kV AC rms (50 Hz, 1 min) withstand between Go and Return conductors. |
| 3. Concentric / Interleaved Outer Return (-I) Copper Conductor Ring | Balanced outer ring of fine-stranded copper bundles surrounding the barrier hose to cancel external magnetic flux and suppress loop inductance to 0.04–0.08 µH/m. |
| 4. Abrasion-Resistant Non-Conductive Outer Water Hose & Split Coaxial Terminals | Fiber-reinforced high-dielectric rubber outer cooling hose (0.4–0.6 MPa working, 1.0–1.2 MPa routine hydrostatic test; optional thermal fiberglass sleeve) terminating in CNC-machined coaxial split-palm or stud connectors. |
WC-2C-LR Metric & Imperial Model Code Breakdown
- WC-2C-LR: Series code: Water-Cooled (WC) Two-Conductor Coaxial (2C) Low-Reactance (LR) induction power cable
- 2x95 to 2x630: Metric Go + Return copper cross-section in mm² (1.6 kA to 11.5 kA, 12–52 L/min deionized water)
- 300MCM to 6000MCM: North American imperial conductor size option (1,400–28,300 A @ 60 Hz; 600–4,350 A @ 3,000 Hz)
- -THG: Optional woven fiberglass radiant-heat & molten-metal splash protective outer sleeve
- 1.5m–12m: Exact custom pin-to-pin overall assembly length with customer split-palm spacing and NPT/BSPP water ports
WC-2C-LR Coreless Induction Melting, Forging & HF Heating Applications
Designed for low-reactance, zero-whip power transfer across medium-frequency and high-frequency induction melting, heating and thermal processing lines.

- Coreless tilting induction melting furnaces (foundry iron, steel, aluminum and copper alloys) operating from 50 Hz to 4 kHz at 5.5–11.5 kA.
- 1–50 kHz HF/MF induction billet forging heaters, seam-welded pipe mills, hardening stations, brazing fixtures and crystal-pulling coils.
- High-current North American 60 Hz–3,000 Hz industrial induction power supplies sized in 300–6,000 MCM pair-foot impedance ratings.
- Long-reach flexible transformer-to-workhead induction leads requiring minimal voltage drop and zero electromagnetic cable kick.
WC-2C-LR Coaxial vs Vacuum Bulkhead vs Hollow-Core vs PWHT Coil Leads
| Cable Architecture | Loop Inductance & Polarity | Frequency & Current Span | Best Furnace Application |
|---|---|---|---|
| WC-2C-LR Two-Conductor Coaxial (this page) | 0.04–0.08 µH/m (Go + Return in 1 hose, -75–85% L') | 50 Hz–50 kHz; 2×95–2×630 mm² & 300–6,000 MCM | Tilting coreless induction melting, billet forging, tube welding & hardening |
| TF-VPT-COAX Vacuum Bulkhead Coaxial | Concentric coaxial + CNC O-ring chamber flange | 1–10 kHz; 2×150–2×1,260 mm² | VIM, VAR, ESR & crystal-growth vacuum chamber wall feed-throughs |
| TF-HC10K / TF-HC2K Hollow-Core Litz | Single-pole per cable (paired externally) | 2 kHz–10 kHz; 70–1,015 mm² | Multi-turn MF heating circuits with separate go/return bus terminations |
| TF-WCIH Water-Cooled PWHT Coil Cable | Ø 24 mm flexible wrap-around heating coil | 1,000 V / 1,500 A; +1,200 °C workpiece | Refinery pipe welds, pressure vessels & stationary field PWHT |
Whenever induction inverter voltage drop or electromagnetic cable whipping limits melt rate, replacing two parallel single-core cables with one WC-2C-LR coaxial assembly immediately slashes loop reactance.
WC-2C-LR Water-Cooled Two-Conductor Coaxial Cable RFQ Checklist
- Operating frequency (50 Hz to 50 kHz), RMS current (kA), inverter output voltage (800–3,000 V AC) and duty cycle.
- Preferred standard: Metric WC-2C-LR (2×95 to 2×630 mm²) or North American Imperial (300–6,000 MCM).
- Exact pin-to-pin assembly length (1.5 m to 12 m) and hydraulic tilt / minimum bending radius constraints.
- Terminal geometry on inverter and coil ends: split-palm spacing, bolt-hole pattern, busbar ridge clearance and water port thread (NPT / G / BSPP).
- Cooling water inlet temperature, available flow rate (L/min or GPM), conductivity (µS/cm) and optional thermal fiberglass splash sleeve.
- Order quantity (MOQ 1 piece or 1 pair, standard manufacturing lead time 7 to 45 working days).
Related selection resources
- Need a Vacuum Chamber Flange? See TF-VPT-COAX Vacuum Feed-Through Assemblies
- Compare Single-Pole 2 kHz / 10 kHz Hollow-Core Litz Water-Cooled Leads
- Compare Single-Core 70–2,500 MCM Induction Melting Furnace Power Leads
- Read Water-Cooled Cable Sizing, Flow, Skin-Effect & 4-Wire Kelvin Guide
- Explore Complete Water-Cooled Furnace Cable & Secondary-Circuit Hub
WC-2C-LR Water-Cooled Two-Conductor Coaxial Cable FAQ
How much inductance does WC-2C-LR save compared to two separate single-core water-cooled cables?
75% to 85% lower loop inductance: housing Go (+I) and Return (-I) copper conductors concentrically inside one water-cooled hose drops inductance to 0.04–0.08 µH/m, cutting reactive voltage drop and eliminating violent electromagnetic cable whipping.
What inter-conductor voltage and hydrostatic tests does WC-2C-LR pass before shipment?
6.0 kV to 10.0 kV AC rms (50 Hz, 1 minute) inter-conductor dielectric withstand across the internal barrier hose, plus 1.0 to 1.2 MPa (10–12 bar) routine hydrostatic pressure testing against a 0.4–0.6 MPa working rating.
Can WC-2C-LR be built to North American 300–6,000 MCM dimensions as well as metric 2×95–2×630 mm²?
Yes. We manufacture both IEC metric WC-2C-LR sizes (2×95 to 2×630 mm², 1.6–11.5 kA) and imperial 300–6,000 MCM two-conductor coaxial leads (up to 28,300 A at 60 Hz and 4,350 A at 3,000 Hz) with custom copper palms and NPT or BSPP coolant ports.
What coolant water conductivity is required for WC-2C-LR above 800 V AC?
Maintain closed-loop deionized water conductivity at or below 50 µS/cm (ideally <= 20–30 µS/cm above 1,500 V) with inlet <= 35 °C and outlet <= 55 °C, preventing electrolytic corrosion across the coaxial split terminals.
What is the minimum order quantity and delivery time for WC-2C-LR coaxial assemblies?
1 custom coaxial cable assembly or 1 matched pair, engineered to exact pin-to-pin length (1.5–12 m) and terminal drawing in 7 to 45 working days.
WC-2C-LR Metric (2×95–2×630 mm²) & Imperial (300–6,000 MCM) Schedules
WC-2C-LR Frequency, Inductance, Dielectric & Coolant Summary
- 0.04–0.08 µH/m ultra-low loop inductance: Concentric Go (+I) and Return (-I) polarity cancellation reduces inductive reactance by 75–85% versus two separate single-core water-cooled cables
- 50 Hz to 50 kHz & 800–3,000 V AC: High-dielectric inter-conductor barrier hose withstands 6.0–10.0 kV AC rms (50 Hz, 1 min) between go and return poles for HF/MF inverters
- Metric 2×95–2×630 mm² & 300–6,000 MCM: Covers both European/IEC metric sizes (1.6–11.5 kA, 12–52 L/min) and North American pair-foot imperial sizes (up to 28,300 A @ 60 Hz / 4,350 A @ 3 kHz)
- 1.0–1.2 MPa routine hydrostatic test: Rated 0.4–0.6 MPa continuous working pressure (up to 80 PSI / 5.5 bar imperial), 8.5× OD dynamic furnace-tilt bend radius, 1.5–12 m custom lengths
- 1 piece or 1 pair custom assembly MOQ: Built to customer copper palm hole pattern, coaxial split-end spacing and water port threads under ISO 9001:2015 manufacturing in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 800 V to 3,000 V AC rms (50 Hz to 50 kHz operating band; 6.0 to 10.0 kV AC rms 1 min inter-conductor dielectric test) |
| Loop inductance per unit length | 0.04 to 0.08 µH/m (75% to 85% lower inductive reactance than two separate single-core water-cooled leads) |
| Metric and imperial size range | Metric 2×95 to 2×630 mm² (1.6 to 11.5 kA); Imperial 300 to 6,000 MCM (1,400 to 28,300 A at 60 Hz; 600 to 4,350 A at 3,000 Hz) |
| Coolant flow, chemistry and pressure | 12 to 52 L/min deionized water (up to 50 µS/cm, inlet up to 35 °C, outlet up to 55 °C); 0.4 to 0.6 MPa working, 1.0 to 1.2 MPa routine hydro test |
| Dynamic bending radius and length | 8.5 × outer hose OD during hydraulic furnace pouring tilt; manufactured to exact pin-to-pin lengths from 1.5 m to 12 m |
| Minimum order and lead time | 1 piece or 1 matched pair custom coaxial assembly built to terminal drawing in 7 to 45 working days |
WC-2C-LR Metric Coaxial Schedule (2×95–2×630 mm²)
| Order Designation | Go + Return Area (mm²) | Voltage & Frequency | Approx. Hose OD (mm) | Rated Current (kA) | Water Flow (L/min) | Min. Bend R (mm) | Next step |
|---|---|---|---|---|---|---|---|
| WC-2C-LR-2x95 | 2×95 (Go & Return) | 1.5 kV · 1–50 kHz | 38.0 | 1.6 | 12 | 320 | Request this size |
| WC-2C-LR-2x150 | 2×150 (Go & Return) | 1.5 kV · 1–50 kHz | 45.0 | 2.5 | 16 | 380 | Request this size |
| WC-2C-LR-2x240 | 2×240 (Go & Return) | 2.0 kV · 0.5–10 kHz | 54.0 | 4.0 | 22 | 460 | Request this size |
| WC-2C-LR-2x320 | 2×320 (Go & Return) | 2.5 kV · 0.25–4 kHz | 62.0 | 5.5 | 28 | 530 | Request this size |
| WC-2C-LR-2x400 | 2×400 (Go & Return) | 3.0 kV · 0.1–3 kHz | 68.0 | 7.0 | 34 | 580 | Request this size |
| WC-2C-LR-2x500 | 2×500 (Go & Return) | 3.0 kV · 0.05–2 kHz | 75.0 | 9.0 | 42 | 650 | Request this size |
| WC-2C-LR-2x630 | 2×630 (Go & Return) | 3.0 kV · 0.05–1 kHz | 84.0 | 11.5 | 52 | 720 | Request this size |
WC-2C-LR Imperial 300–6,000 MCM Coaxial Sizing Reference
| Model & Imperial Size | OD (in) | Min. Bend Dia (in) | 60 Hz Current (A) | 60 Hz Rac / Z (μΩ/pair-ft) | 3,000 Hz Current (A) | 3,000 Hz Rac / Z (μΩ/pair-ft) | Next step |
|---|---|---|---|---|---|---|---|
| WC-2C-LR-300MCM (300 MCM) | 2.62 | 21 | 1,400 | 77 / 76 | 600 | 187 / 1,035 | Request this size |
| WC-2C-LR-1000MCM (1,000 MCM) | 3.62 | 29 | 4,700 | 23 / 27 | 1,175 | 88 / 726 | Request this size |
| WC-2C-LR-1500MCM (1,500 MCM) | 5.00 | 40 | 7,000 | 16 / 23 | 1,290 | 87 / 828 | Request this size |
| WC-2C-LR-2000MCM (2,000 MCM) | 5.50 | 44 | 9,400 | 12 / 21 | 1,590 | 71 / 829 | Request this size |
| WC-2C-LR-2500MCM (2,500 MCM) | 5.50 | 44 | 11,700 | 11 / 19 | 2,020 | 58 / 785 | Request this size |
| WC-2C-LR-3000MCM (3,000 MCM) | 6.00 | 48 | 14,100 | 9 / 18 | 2,540 | 50 / 797 | Request this size |
| WC-2C-LR-4000MCM (4,000 MCM) | 6.00 | 48 | 18,800 | 7 / 16 | 2,800 | 47 / 725 | Request this size |
| WC-2C-LR-6000MCM (6,000 MCM) | 7.50 | 60 | 28,300 | 6 / 18 | 4,350 | 39 / 830 | Request this size |
Imperial sizing equations (pair-foot = 1 ft Go + 1 ft Return): Power Loss (W) = I² × Rac × L; Voltage Drop (V) = I × Z × L; Min Water Flow (GPM at 30 °F ΔT) = Power Loss / 4,410 (minimum design flow >= 2 GPM; max water inlet 90 °F / 32 °C, max outlet 150 °F / 65 °C, max pressure 80 PSI).
ASCII part references for BOM and ERP entry: WC-2C-LR-2x95, WC-2C-LR-2x150, WC-2C-LR-2x240, WC-2C-LR-2x320, WC-2C-LR-2x400, WC-2C-LR-2x500, WC-2C-LR-2x630, WC-2C-LR-300MCM to WC-2C-LR-6000MCM.
WC-2C-LR Reference Induction Heating & Testing Standards
| Standard or specification | Application |
|---|---|
| IEC 60519-3 & DIN VDE 0721 | Safety in electroheat and electromagnetic processing installations — particular requirements for induction and conduction heating and induction melting (design and manufacturing basis; not a third-party listing). |
| JB/T 6314 & ISO 9001:2015 Workshop Verification | Water-cooled furnace cable construction reference with 100% routine 6–10 kV AC inter-conductor dielectric withstand and 1.0–1.2 MPa hydrostatic pressure verification prior to dispatch. |
Certifications and document support
TEBAOFLEX ISO 9001:2015 manufacturing and 1.0 MPa hydrostatic test records
IEC 60519-3 — Safety in Electroheat Installations: Induction and Conduction Heating & Melting
DIN EN 60519-3 (VDE 0721) — Particular Requirements for Induction Heating & Melting
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-WCIH 1,000 V / 1,500 A Water-Cooled Flexible Induction Heating & PWHT Coil Cable (Ø 24 mm Silicone-Aramid Hose, +1,200 °C Workpiece)
A related cable option for a different application or duty profile.
View productTF-VPT Vacuum Furnace Coaxial Water-Cooled Power Feed-Through & Bulkhead Cable Assembly (VIM / VAR / ESR)
A related cable option for a different application or duty profile.
View productTF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.