Jiangsu Tebaoflex Special Cable · ISO 9001:2015 Manufacturing · Taicang, China
TEBAOFLEX engineers and custom-manufactures complete water-cooled furnace cables, bolted-flange water-cooled compensators, rigid water-cooled copper bus tubes, copper-steel clad electrode arms and extra-flexible air-cooled high-current connectors across 35 mm² to 10,000 mm² (70 MCM to 2,500 MCM, 1 kA to 120 kA, up to 3,000 V AC / 10 kHz). Every custom secondary-circuit assembly is built to customer terminal drawings, hydrostatically tested to 8.5–10 bar, micro-ohm resistance checked and dispatched worldwide in 7 to 45 working days.
Complete Water-Cooled & High-Current Secondary-Circuit Product Matrix
Select the exact TEBAOFLEX product family by furnace type, terminal coupling, cooling architecture and operating frequency:
| TEBAOFLEX Series | Section, Current & Voltage | Key Mechanical / Cooling Feature | Target Furnace / Industrial Duty | Specification Page |
|---|---|---|---|---|
| TF-EAF-LF-WCC | 1,000–7,000 mm² · 5–35 kA | Fluted water core, double-groove bumper rings, rotating swivel head | AC/DC Electric Arc Furnaces (EAF) & Ladle Furnaces (LF) | EAF & LF Water-Cooled Cable |
| TF-SAF / TF-WCF | 750–7,000 mm² · 50/60 Hz | M48–M80 ring-nut & heavy low-GMR pressed copper palms | Submerged-Arc (SAF), Ferroalloy, Silicon & ESR Smelting | SAF High-Current Furnace Cable |
| TF-WCC-COMP (New) | 1,500–10,000 mm² · 6–45 kA | Short 0.5–2.5 m bolted Cu ring flange + non-magnetic 304 SS collar | Transformer bushing to delta closure / busbar thermal expansion | Water-Cooled Busbar Compensator |
| TF-WCP-PIPE (New) | 300–1,480 mm² · 2.9–15 kA · 3,000 V | Detachable Type E / Type D pipe-contact ring & union nut (Ø 40–60 mm) | Direct jump onto rigid copper bus pipes, MF coils & polysilicon CVD | Pipe-Connection Water-Cooled Cable |
| TF-WCT-CLAMP (New) | 95–8,000 mm² · 1–45 kA · 3,000 V | Electrolytic tin-plated anti-chloride Cu + 260–320 mm rigid clamp collar | Coastal / high-chloride water loops & clamped parallel furnace bundles | 3,000 V Clamped & Tin-Plated Cable |
| TF-IFL / TF-WCHC | 70–2,500 MCM · 35–2,000 mm² | SAE 37° JIC swivel flare, NPT/BSPP flat palms & Center-Channel core | Coreless tilting induction melting, foundry & glass furnaces | Induction Furnace Power Lead |
| TF-HC10K / TF-WCCX | 70–1,015 mm² · 2 kHz & 10 kHz | Double-enameled hollow-core Litz & 2-pole open-air coaxial | Medium-frequency billet heating, forging & hardening stations | 10 kHz Hollow-Core & Coaxial Lead |
| TF-VPT-COAX (New) | 2×150–2×1,260 mm² · 1–10 kHz | Concentric 2-pole coaxial + CNC O-ring vacuum bulkhead flange | VIM, VAR, ESR, PAM, EBF & crystal-growth vacuum furnaces | Vacuum Coaxial Feed-Through Cable |
| TF-BT Delta Closure (New) | Ø 40×6–168×16 mm · 5–120 kA | Seamless rigid water-cooled Cu tubes, delta closures & heat-shrink | EAF/LF transformer vaults, ESR dual-station & polysilicon busways | Water-Cooled Copper Bus Tubes |
| TF-EA Electrode Arm (New) | 15–180 t EAF/LF · 15–110 kA | Copper-steel explosion-clad box girder + internal water baffles | UHP AC/DC Electric Arc Furnace & Ladle Furnace electrode arms | Copper-Steel Clad Electrode Arm |
| TF-KICKLESS / TF-WCRW | 120–630 mm² · 300–800 MCM | 6-rope alternate-polarity bipolar kickless & ISO 8205-2 unipolar | Automotive BIW robotic spot-welding & resistance welding guns | Kickless / ISO 8205-2 Welding |
| TF-SIHC 3kV/6kV (New) | 2.5–300 mm² · 1.8/3 & 3.6/6 kV | 0.07/0.10 mm Cu, dual-wall +180 °C halogen-free silicone (EN 45545) | Compact MV switchboards, traction converters & pressed jumpers | 1.8/3 & 3.6/6 kV Silicone Cable |
| TF-LIFY / ESUY / TPE-U (New) | 2.5–240 mm² · 450/750 V & 1 kV | LifY PVC, clear-sheathed braided ESUY earthing & oil-proof TPE-U | Control cabinets, test benches, safety grounding & rugged LV leads | LifY, ESUY & TPE-U Cables |
| TF-SHUNT / TF-ACHC / TF-ACC | 70–4,500 mm² · Air-Cooled | Press-welded 0.1 mm Cu foil shunts, NEMA braids & +800 °C sleeves | Dry busbar expansion, furnace jumpers, PWHT & resistance welders | Shunts / ACHC / ACC / ACIH |
| WC-2C-LR Coaxial (New) | 2×95–2×630 mm² / 300–6,000 MCM | IEC 60519-3 Go/Return coaxial (0.04–0.08 μH/m, -75–85% L′, 50 Hz–50 kHz) | Low-reactance coreless induction melting, forging & HF heating | Two-Conductor Coaxial Cable |
| TF-WCIH PWHT Coil (New) | 1,500 A · 1,000 V · Ø 24 mm | Silicone-para-aramid hose (7 bar, ≥ 5 L/min), +1,200 °C workpiece | Refinery pipelines, pressure vessels & heavy weld PWHT coils | Water-Cooled PWHT Induction Coil |
| TF-IBR Insulated Braid (New) | 10–210 mm² · 145–540 A · 1 kV | Extruded 1 kV halogen-free silicone / FR PVC + press-welded Cu ends | Switchgear cubicles, transformers, UPS & BESS battery bus links | Insulated Flat Braided Connector |
Real Workshop Production & Hydrostatic Verification
Every assembly is manufactured, cold-pressed, hydrostatically pressure-tested and export-crated under traceable shop quality inspection (never third-party drop-shipped):



Water-Cooled Cable Engineering & Maintenance Guides
- Water-Cooled Furnace Cable Sizing, Coolant Flow, Pressure Drop & 4-Wire Resistance Testing Guide — Covers 4.5–8.4 A/mm² economic loading, 0.4 K/s water-loss rise, 1 m/kV AC hose isolation, 60 Hz–10 kHz skin effect and 4-wire Kelvin burnout rate math.
- EAF Water-Cooled Cable Failure Modes, Torsion Relief & Terminal Selection Guide — Explains why healthy parallel cables run hotter when a neighbor fails, rotating swivel relief, double-groove bumper rings, 5 terminal interfaces and 1:1 replacement drawings.
- Air-to-Water-Cooled Furnace Cable Conversion, Silent I²R Power Loss & Coaxial Upgrade Guide — Quantifies hidden secondary resistance losses, air-to-water conversion thresholds, 0.04–0.08 μH/m coaxial inductance reduction and 1,500 A PWHT coil upgrades.
- Also explore our High-Temperature Silicone & Fluoropolymer Wire Hub, High-Voltage Silicone Cable Hub and Welding Cable Solutions Hub.
Frequently Asked Questions on Water-Cooled Furnace Cables
What furnace secondary-circuit products does TEBAOFLEX manufacture?
18 coordinated product families span EAF/LF/SAF water-cooled cables (750–7,000 mm²), induction power leads (70–2,500 MCM), 10 kHz hollow-core & coaxial leads, bolted-flange water-cooled compensators (1,500–10,000 mm²), Ø 40–60 mm pipe-connection cables, 3,000 V tin-plated/clamped cables, vacuum coaxial bulkhead assemblies, rigid water-cooled copper bus tubes, copper-steel clad electrode arms and air-cooled switchgear/shunt connectors.
How does TEBAOFLEX test water-cooled cables before export shipment?
Every water-cooled furnace cable and compensator assembly undergoes factory hydrostatic pressure inspection (8.5–10 bar / 0.85–1.0 MPa against a 6 bar continuous working rating) and 4-wire Kelvin micro-ohm conductor DC resistance verification prior to crating; formal test records are confirmed per order quotation.
Can TEBAOFLEX manufacture 1:1 direct replacements for worn European or North American furnace cables?
Yes. Send us your terminal drawing, pin-to-pin length, bolt-hole pattern, water-port thread (NPT, G/BSPP or 37° JIC swivel) or worn cable photographs. We custom-machine forged Cu-ETP/Cu-HCP copper heads and build 1:1 new-build direct replacements without cross-border repair customs delays.
What is the minimum order quantity and delivery lead time for custom water-cooled assemblies?
1 piece or 1 matched 3-phase set for large EAF cables, water-cooled compensators, bus tubes and electrode arms; 2 pieces (1 pair) for induction, pipe-connection and vacuum coaxial leads; 5 pieces for kickless/welding leads; 50 m for bulk air-cooled reels. Standard manufacturing lead time is 7 to 45 working days.
Shipment QA & Material Traceability Package (5-Document Export Dossier)
For export orders of heavy-duty EAF water-cooled cables and rotary (swivel) water-cooled furnace cables, TEBAOFLEX supplies an order-specific 5-document Factory Quality Inspection & Material Traceability Dossier under TEBAOFLEX letterhead—verifying hydrostatic integrity, electrical resistance, forged terminal dimensions and incoming copper/EPDM lot traceability prior to ocean shipment.
| Document | Inspection Scope | Representative Verified Benchmark |
|---|---|---|
| 1. Certificate of Conformity (CoC) | Batch release tying customer drawing, serialized quantity and proof pressure | Serialized matched sets (e.g., 4,000 mm² rotary × 8 pcs; 4,500 mm² EAF × 6 pcs) |
| 2. Hydrostatic Pressure Test Report | Entire-assembly cooling-circuit water hold with pressure-time curve at approx. 35 °C | 1.0 MPa × 30 min (rotary) or 0.8 MPa × 12 h endurance (EAF) — zero leakage |
| 3. Final Assembly Inspection Report | Non-magnetic stainless check, rope lay pitch, micro-ohm DC resistance & sleeve insulation | Lay pitch 1.2–1.4 m · sleeve > 10 MΩ · 17.29 µΩ on 4,500 mm² × 10.5 m |
| 4. Terminal Dimensional Sheet | Piece-by-piece caliper and gauge record of forged copper pad, bolt holes & water threads | Length ±50 mm · 305 ± 2 × 40 ± 1 mm pad · 8-φ18 ± 1 mm · 3-G1″ ports |
| 5. Incoming Raw-Material MTCs | Soft stranded copper rope, T2 copper bar stock & reinforced NR/EPDM hose/bumper rings | Cu ≥ 99.95% · 0.0443 Ω/km (TJR 400 mm²) · 3,000 V / 5 min & 1.2 MPa sleeve proof |
Scope note: Factory QA & MTC packages verify batch conformance to approved drawings under ISO 9001:2015 manufacturing management (Certificate No. 244-24-QI-17425-R0-Q) and are not third-party UL/VDE/CE product type certifications. Witnessed FAT or third-party inspection (SGS, BV or TÜV) is available by order agreement.
Download Sample 5-Document QA Dossier (PDF) Read Case 27: Verified 4,000–4,500 mm² QA Record →
Request a Custom Water-Cooled Cable or Secondary-Circuit Quotation
Upload your terminal drawing, bolt-hole pattern, pin-to-pin length, operating current/frequency and water-port thread specification for an engineering quote (standard delivery 7 to 45 working days):