KGG, KGGR, KGGP, KGGRP & KGG22/KGG32 450/750 V Silicone Rubber Control & Armoured Cable
KGG, flexible KGGR, copper-braid-screened KGGP / KGGRP, copper-tape-screened KGGP2, and steel-armoured KGG22 / KGG32 (TF-KGG-KGGR-750V) are 450/750 V metallurgical silicone rubber control cables rated from -60 °C to +180 °C. Available from 2×0.75 mm² up to 61×2.5 mm² for blast-furnace, EAF, boiler and coking-plant PLC, interlock and valve circuits.
KGG, Class 5 flexible KGGR, EMC-screened KGGP / KGGRP / KGGP2 and steel-armoured KGG22 / KGG32 450/750 V silicone rubber control cables safeguard multi-channel PLC I/O, limit switches, burner interlocks and hydraulic valve solenoids from -60 °C to +180 °C across 2×0.75 mm² drops up to 61×2.5 mm² marshalling trunks.
In blast-furnace hot-blast stove galleries, EAF melt shops, utility coal/biomass boilers and coking ovens, PVC control cables (KVV / KVVP) soften above +70 °C and release corrosive HCl gas, whereas European 300/500 V SiHF cables stop at 24–25 cores and lack heavy steel-tape (22) or vertical-shaft steel-wire (32) armour options. KGG-series control cables pair white-numbered high-tear silicone cores with non-hygroscopic fiberglass lappings, >= 80 % tinned-copper EMC braids or galvanized steel armour under a halogen-free silicone jacket.
Specify KGG or KGGP for fixed tray and conduit marshalling; specify KGGR or KGGRP (6× OD bend radius) on moving furnace dampers, lance carriages and vibrating screens; specify KGG22 for crush/rodent protection in hot cable trenches, or KGG32 where vertical furnace tower risers impose tensile load; for hot acid/solvent immersion up to +260 °C, switch to KFF / KFFP fluoroplastic control cable. MOQ 50 m (100 m on light unarmoured <= 10-core sizes), 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
KGG, KGGR, KGGP & KGG22/KGG32 450/750 V Construction
Engineered to GB/T 9330 metallurgical silicone control geometry with IEC 60228 copper conductors and 2,500 V AC 5-minute dielectric verification.

| Component | Material and construction |
|---|---|
| 1. Solid/Stranded (KGG) or Class 5 Fine-Stranded Copper (KGGR) | IEC 60228 Class 1 or Class 2 bare/tinned copper on fixed KGG / KGGP / KGG22 / KGG32, or Class 5 extra-flexible bare/tinned copper on KGGR and KGGRP. |
| 2. 450/750 V Extruded Silicone Rubber Core Insulation | High-purity silicone rubber cores clearly numbered in permanent heat-cured white digits (1, 2, 3...) or colour-coded on 2–5 core sizes. |
| 3. Fiberglass Bedding + Optional Screen (P / P2) + Steel Armour (22 / 32) | Concentric multi-layer core lay wrapped in E-glass tape; >= 80 % tinned-copper wire braid (KGGP/KGGRP), overlapped copper tape (KGGP2), double steel tape (KGG22) or fine galvanized steel wires (KGG32). |
| 4. Halogen-Free Brick-Red or Black Silicone Rubber Outer Sheath | Ozone-, UV- and thermal-aging-resistant silicone rubber jacket rated -60 °C to +180 °C continuous (+200 °C short-term). |
KGG, KGGR, KGGP & KGG22/KGG32 Code Breakdown
- K: Industrial control, signalling and interlock cable family (450/750 V)
- G + G: Silicone rubber core insulation (G) + silicone rubber outer sheath (G)
- R (in KGGR / KGGRP): Extra-flexible IEC 60228 Class 5 fine-stranded copper conductors
- P / P2: Tinned-copper wire braid EMC screen (P) or overlapped copper-tape electrostatic screen (P2)
- 22 / 32: Double galvanized steel-tape armour (22) or fine galvanized round steel-wire armour (32)
KGG & KGGP Blast-Furnace, EAF, Coking & Boiler Circuits
Designed for 24 V DC to 450/750 V AC control, signalling, protection-relay and actuator circuits in high-temperature industrial plants.

- Blast-furnace hot-blast valve stands, tuyere stock instrumentation, top-charging bellless chute controls and torpedo-ladle track switches.
- Electric arc furnace (EAF) and ladle furnace (LF) roof limit switches, oxy-fuel burner panels, baghouse damper actuators and fume-hood sensors.
- Thermal power-plant boiler sootblower control loops, steam-turbine bypass valve cabinets, rotary kiln burner BMS wiring and glass-tank batch chargers.
- Export EPC metallurgical, cement and chemical projects specifying KGG, KGGR, KGGP, KGGRP, KGGP2, KGG22 or KGG32 on design-institute schedules.
KGG / KGG22 (450/750 V) vs SiHF / SiHFC vs KFF / KFFP
| Control Family | Voltage & Max Cores | Shield / Armour & Temp | Best Engineering Fit |
|---|---|---|---|
| KGG / KGGR / KGGP / KGG22 / KGG32 (this page) | 450/750 V; 2 to 61 cores | -60 to +180 °C silicone; Cu braid, Cu tape, STA (22) or SWA (32) | Heavy metallurgical/power-plant 450/750 V trunks, trenches & vertical shafts |
| SiHF & SiHFC / SiHF-C-Si | 300/500 V; 2 to 25 cores | -60 to +180 °C EN 50525-2-83 Class 5 tinned Cu (unscreened or Cu braid) | Compact European 24 V DC / 230 V AC machine and oven control drops |
| SiHF-P (GSWB Braided) | 300/500 V; 2 to 24 cores | -60 to +180 °C silicone + external galvanized steel wire braid | Flexible external abrasion guard on dry 300/500 V machine drops |
| KFF / KFFP / KFFP2-22 | 450/750 V; 2 to 37 cores | -60 to +200/+260 °C FEP or PFA + Cu screen / steel-tape armour | Hot acid mist, hydraulic ester oil, solvent immersion or +200 to +260 °C zones |
Need individual pair shields for 4–20 mA analog transmitters or RS-485 signals in hot zones? Specify DJGPGP (silicone computer cable) or DJFPFP (+200/+260 °C fluoroplastic computer cable) on your RFQ.
KGG, KGGR, KGGP & KGG22/KGG32 Control Cable RFQ Checklist
- Exact sub-model (KGG, KGGR, KGGP, KGGRP, KGGP2, KGG22 or KGG32) and core count × cross-section (0.75 to 6.0 mm²).
- Conductor class and finish: Class 1/2 fixed vs Class 5 flexible, bare vs tinned copper.
- Flame-retardant category if required (standard IEC 60332-1-2 or bunched tray ZRC / ZRB / ZRA per IEC 60332-3).
- Total project meterage and drum cut schedule (MOQ 50 m on >= 12C / screened / armoured, 100 m on light <= 10C; 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Silicone & Fluoroplastic Control Cables
- Pair with YGC, YGCR & YGC22 0.6/1 kV Metallurgical Silicone Power Cable
- Compare KFF, KFFP & DJFPFP +200/+260 °C Acid-Proof Fluoroplastic Control Cable
- Compare SiHFC / SiHF-C-Si 300/500 V European Screened Silicone Cable
- Compare SiHF-P 300/500 V GSWB Steel-Wire-Braided Silicone Cable
- Engineering guide: Elastomer vs fluoropolymer oil & chemical resistance
KGG, KGGR, KGGP & KGG22/KGG32 Control Cable FAQ
How does 450/750 V KGG / KGGR differ from 300/500 V SiHF silicone control cable?
KGG and KGGR carry a thicker 450/750 V silicone insulation wall (tested at 2,500 V AC vs 2,000 V AC on SiHF), scale up to 61 control cores per trunk, and offer heavy double steel-tape armour (KGG22) and vertical-shaft fine steel-wire armour (KGG32) not covered by EN 50525-2-83 SiHF.
When should I specify KGG22 steel-tape armour versus KGG32 fine steel-wire armour?
Specify KGG22 for horizontal cable trenches, furnace catwalks and floor ducts requiring radial crush and rodent protection; specify KGG32 whenever the cable hangs in a vertical blast-furnace shaft, boiler tower or long pull duct because helical steel wires carry longitudinal tensile load that steel tape cannot.
Should I choose KGGP / KGGRP copper braid or KGGP2 copper tape screening?
Choose KGGRP or KGGP (>= 80 % tinned-copper wire braid) whenever the cable flexes, vibrates or requires low high-frequency transfer impedance against VFD and EAF arc noise; choose KGGP2 overlapped copper tape only on strictly fixed runs.
When should I switch from KGG silicone control cable to KFF / KFFP fluoroplastic control cable?
Switch to KFF or KFFP when continuous ambient temperature exceeds +180 °C (up to +260 °C on PFA) or when cables contact pressurized synthetic hydraulic oils, concentrated pickling acids or aromatic solvents that swell silicone rubber.
What is the minimum order quantity and delivery lead time for KGG-series cables?
50 m per specification on 12-core through 61-core, screened or armoured constructions (100 m on 2-core to 10-core unscreened sizes), delivered in 7 to 45 working days.
KGG, KGGR, KGGP, KGG22 & KGG32 Dimensional Schedule
KGG & KGGR 450/750 V Core Range, Armour & Drum Summary
- 450/750 V & up to 61 control cores: Higher 450/750 V insulation rating (2,500 V AC test) and high-density 2-core to 61-core trunking beyond 300/500 V European SiHF control cables
- Fixed Class 1/2 or Class 5 flex: KGG / KGGP for rigid terminal-block termination in furnace galleries, or KGGR / KGGRP with IEC 60228 Class 5 fine copper for vibrating damper actuators
- EMC braid or copper-tape shields: KGGP and KGGRP (>= 80 % tinned-copper braid) or KGGP2 (helical copper tape) block thyristor rectifier, EAF arc and VFD switching interference
- KGG22 tape & KGG32 wire armour: Double galvanized steel tape (KGG22) for horizontal hot trenches, or fine galvanized steel wire armour (KGG32) for vertical furnace shafts and tension pulls
- 50 m / 100 m factory drums: Supplied in 100 m drums on light 2–10 core builds and 50 m drums on >= 12-core, screened or armoured trunks in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 450/750 V AC with 2500 V AC 5-minute routine dielectric withstand test between cores and screen |
| Core count and cross-sections | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52 and 61 cores in 0.75, 1.0, 1.5, 2.5, 4.0 and 6.0 mm2 |
| Screening and armouring options | Unscreened (KGG, KGGR), tinned-copper braid (KGGP, KGGRP), copper tape (KGGP2), steel-tape armoured (KGG22) and fine steel-wire armoured (KGG32) |
| Operating temperature and bend radius | -60 C to +180 C continuous; minimum bend radius 6x OD (unarmoured KGG and KGGR), 10x OD (screened KGGP and KGGP2) and 12x OD (armoured KGG22 and KGG32) |
| Minimum order and lead time | 50 m on 12-core and above, screened or armoured builds (100 m on 2 to 10 core unarmoured sizes); 7 to 45 working days |
| Insulation resistance | At least 100 MOhm*km at +20 C and at least 12 MOhm*km at +70 C hot-state verification |
| Halogen-free fire safety | Halogen-free per IEC 60754-1, low smoke acidity per IEC 60754-2 and flame-retardant per IEC 60332-1-2 |
KGG & KGGR 450/750 V Unscreened Silicone Control Schedule
| Model & Core × mm² | Conductor Class (KGG / KGGR) | Max. R at 20 °C Class 5 (Ω/km) | Nom. OD KGG / KGGR (mm) | Min. Bend Radius | Approx. Weight (kg/km) | Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| KGGR 3×0.75 mm² | Class 1/2 or Class 5 | 26.0 | 8.0 / 8.4 | 6× OD | 86 | 100 m | Request this size |
| KGGR 4×1.0 mm² | Class 1/2 or Class 5 | 19.5 | 9.2 / 9.7 | 6× OD | 118 | 100 m | Request this size |
| KGGR 4×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 10.2 / 10.8 | 6× OD | 152 | 100 m | Request this size |
| KGGR 5×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 11.2 / 11.8 | 6× OD | 184 | 100 m | Request this size |
| KGGR 7×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 12.4 / 13.1 | 6× OD | 238 | 100 m | Request this size |
| KGGR 10×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 15.6 / 16.4 | 6× OD | 345 | 100 m | Request this size |
| KGGR 12×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 16.2 / 17.0 | 6× OD | 398 | 50 m | Request this size |
| KGGR 14×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 17.1 / 18.0 | 6× OD | 452 | 50 m | Request this size |
| KGGR 19×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 19.2 / 20.2 | 6× OD | 595 | 50 m | Request this size |
| KGGR 24×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 22.4 / 23.5 | 6× OD | 755 | 50 m | Request this size |
| KGGR 37×1.5 mm² | Class 1/2 or Class 5 | 13.3 | 26.2 / 27.6 | 6× OD | 1,110 | 50 m | Request this size |
| KGG 10×2.5 mm² | Class 1/2 or Class 5 | 7.98 | 18.8 / 19.6 | 6× OD | 515 | 50 m | Request this size |
| KGG 61×0.75 mm² | Class 1/2 Fixed | 24.5 | 27.0 / — | 6× OD | 1,020 | 50 m | Request this size |
KGGP, KGGRP, KGGP2, KGG22 & KGG32 Screened & Armoured Schedule
| Model & Core × mm² | Screen / Armour Construction | Nom. OD (mm) | Min. Bend Radius | Approx. Weight (kg/km) | Primary Furnace Duty | Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| KGGP 4×1.5 mm² | >=80% Tinned Cu Braid | 11.8 | 10× OD | 198 | Burner / valve EMC feedback | 100 m | Request this size |
| KGGRP 7×1.5 mm² | Class 5 + Tinned Cu Braid | 14.8 | 10× OD | 312 | Mobile actuator EMC control | 50 m | Request this size |
| KGGRP 12×1.5 mm² | Class 5 + Tinned Cu Braid | 18.6 | 10× OD | 495 | EAF / LF hydraulic rack I/O | 50 m | Request this size |
| KGGP 19×1.5 mm² | >=80% Tinned Cu Braid | 21.0 | 10× OD | 695 | Hot-blast stove PLC trunk | 50 m | Request this size |
| KGGP 24×1.0 mm² | >=80% Tinned Cu Braid | 20.8 | 10× OD | 610 | Multi-channel interlock trunk | 50 m | Request this size |
| KGGP2 14×1.5 mm² | Helical Copper Tape Screen | 18.5 | 12× OD | 535 | Fixed cabinet electrostatic shield | 50 m | Request this size |
| KGG22 7×1.5 mm² | Double Galv. Steel Tape | 16.8 | 12× OD | 430 | Hot cable trench / catwalk | 50 m | Request this size |
| KGG22 12×1.5 mm² | Double Galv. Steel Tape | 20.4 | 12× OD | 645 | Crush-resistant kiln gallery | 50 m | Request this size |
| KGG22 19×1.5 mm² | Double Galv. Steel Tape | 23.2 | 12× OD | 885 | Blast-furnace marshalling trench | 50 m | Request this size |
| KGG22 37×1.5 mm² | Double Galv. Steel Tape | 29.8 | 12× OD | 1,460 | Main hot-zone control trunk | 50 m | Request this size |
| KGG32 12×1.5 mm² | Fine Galv. Steel Wire Armour | 22.6 | 12× OD | 790 | Vertical furnace tower riser | 50 m | Request this size |
All KGG-series sizes are available with tinned copper conductors (-Sn) at +180 °C for anti-oxidation terminal reliability, and in flame-retardant ZR-KGG / ZRC-KGGP bunched-tray grades (IEC 60332-3-24). Final OD and weight are confirmed on the quotation drawing.
ASCII part references for BOM and ERP entry: TF-KGG-7X1.5, TF-KGG-12X1.5, TF-KGGR-12X1.5, TF-KGGR-19X1.5, TF-KGGP-12X1.5, TF-KGGRP-12X1.5, TF-KGGP2-14X1.5, TF-KGG22-12X1.5, TF-KGG22-19X1.5, TF-KGG32-12X1.5.
KGG & KGGR Reference Standards (GB/T 9330 & IEC 60228)
| Standard or specification | Application |
|---|---|
| GB/T 9330 & TICW Metallurgical Control Cable Reference | 450/750 V insulation wall thickness, core numbering, 2,500 V AC voltage test and 22 / 32 steel armouring dimensions. |
| IEC 60228 Class 1, Class 2 & Class 5 | Solid, stranded and extra-flexible annealed bare or tinned copper conductor DC resistance limits. |
| IEC 60332-1-2, IEC 60332-3-24 & IEC 60754 | Vertical flame retardance (ZR / ZRC bunched tray option) and zero-halogen low-corrosivity smoke compliance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 2.5 kV control cable routine testing
IEC 60228 — Conductors of insulated cables (Class 1, Class 2 & Class 5)
IEC 60332-1-2 — Flame propagation testing of insulated control cables
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)
A related cable option for a different application or duty profile.
View productKFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable
A related cable option for a different application or duty profile.
View productSiHFC & SiHF-C-Si EMC Screened Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.