High Temperature Cables TEBAOFLEX

FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C)

FEP/PFA-GSWB and stainless-steel-braided PFA-SSWB 0.6/1 kV high-temperature armoured power cables (TF-FEP-PFA-GSWB-1KV) combine IEC 60228 Class 5 plated copper conductors, FEP (+200 °C) or PFA (+260 °C) insulation and inner sheathing, a woven E-glass thermal barrier and galvanized (GSWB) or 304/316 stainless steel wire braid (SSWB). Built for 3G1.5 to 4G35 mm² hot-zone and acid-plant motor feeders on 300 m drums.

Product information
SKU
TF-FEP-PFA-GSWB-1KV
Brand
TEBAOFLEX
Product overview

FEP/PFA-GSWB and stainless PFA-SSWB 0.6/1 kV steel-wire-braided fluoropolymer power cables protect three-phase motor and heater feeders where +200 °C to +260 °C radiant heat coincides with mechanical impact, metal splatter or corrosive chemical splash, spanning 3G1.5 mm² auxiliary drives up to 4G35 mm² and 5G16 mm² heavy industrial feeders.

In steel continuous-casting spray chambers, aluminum smelters, glass furnaces, polymer melt-pump skids and HPAL / SX-EW acid-leach plants, armoured N2GFAF / SiHF-GL-P silicone power cables absorb hot hydraulic ester oils, synthetic heat-transfer fluids and acid fumes until their elastomer walls soften and split. Replacing silicone rubber with melt-extruded FEP (+200 °C) or PFA (+260 °C) beneath an E-glass thermal cushion and >= 80 % steel wire braid delivers dual chemical and mechanical survival across multi-year furnace campaigns.

Select galvanized steel braided FEP/PFA-GSWB for dry foundry, furnace, kiln and glass-plant catwalks, or select 304/316L stainless braided PFA-SSWB (with optional extruded PFA outer chemical jacket) for wet pickling tanks, offshore chemical skids and washdown reactors. Every production drum undergoes routine 3,500 V AC 5-minute dielectric testing (MOQ 300 m per size, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Cable Construction

Engineered to IEC 60502-1 0.6/1 kV voltage geometry using high-temperature plated Class 5 copper, pinhole-free fluoropolymer extrusion and high-tensile steel braiding.

Clean 2D engineering cross-section of 4G 0.6/1 kV PFA-SSWB power cable showing outer steel wire braid armour, fiberglass thermal buffer, PFA inner sheath and brown, black, grey and green-yellow cores
0.6/1 kV fluoropolymer armoured power cross-section: HD 308 phase + earth cores, impervious PFA/FEP inner sheath, glass tape and >= 80 % steel braid.
FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C) construction
ComponentMaterial and construction
1. Plated Flexible Copper Conductors (IEC 60228 Class 5)Fine-stranded tinned copper (up to +180/+200 °C on FEP-GSWB), silver-plated copper (up to +205/+250 °C) or 27 % nickel-plated copper (up to +260 °C continuous on PFA-SSWB).
2. 0.6/1 kV Extruded FEP or PFA Core Insulation (HD 308 S2)Thick-wall fluoropolymer phase insulation colour-coded per HD 308 S2 (brown, black, grey + green/yellow protective earth on G builds) or numbered black cores.
3. Extruded Fluoropolymer Inner Sheath & E-Glass Thermal BufferImpervious FEP or PFA inner sheath seals the core assembly against fluids, wrapped with woven alkali-free E-glass tape to cushion clamping and radiant heat.
4. Galvanized (GSWB) or 304/316 Stainless Steel Wire Braid (SSWB)Dense >= 80 % coverage abrasion/rodent/impact steel wire braid armour (optional outer translucent/black FEP or PFA oversheath on -F builds).

FEP/PFA-GSWB & PFA-SSWB Code Breakdown

  • FEP / PFA: 0.6/1 kV fluoropolymer insulation & inner sheath: FEP (+200 °C) or PFA (+260 °C)
  • GSWB: Galvanized steel wire braid armour (>= 80 % coverage) for dry impact & slag zones
  • SSWB: 304 / 316L stainless steel wire braid armour for acid mist, washdown & marine/chemical skids
  • -F (Optional): Extruded outer FEP or PFA chemical oversheath over the metallic steel braid
  • 3G / 4G / 5G: Core count including green/yellow protective earth conductor per HD 308 S2
Applications

FEP/PFA-GSWB Melt-Pump, Smelter & Acid-Plant Applications

Built for heavy-industry 380 V / 400 V / 480 V / 690 V AC power distribution where unarmoured fluoropolymer or armoured silicone cables fail.

Stainless-steel-braided FEP/PFA-GSWB 0.6/1 kV high-temperature power cables entering armoured glands on a melt-pump motor beside a hot industrial furnace
Armoured fluoropolymer motor feeders supplying a high-temperature melt-pump drive in a radiant furnace bay.
  • Polymer spinning & extrusion melt-pump drives, thermal-oil (Dowtherm / Therminol) circulation pumps and high-pressure reactor agitator motors.
  • Steel pickling & hot-dip galvanizing drive motors, continuous-casting run-out roller tables, ladle transfer cars and billet reheat furnace fans.
  • HPAL nickel-cobalt autoclave feed pumps, phosphoric/sulfuric acid transfer skids, chlor-alkali cell-room auxiliaries and chemical incinerator blowers.
  • Industrial electric resistance immersion heaters, flange process heaters, glass-lehr heating zones and autoclave air-circulation blowers.

FEP/PFA-GSWB & PFA-SSWB vs SiHF-GL-P vs KFFP2-22

FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV vs SiHF-GL-P Silicone vs Unarmoured FEP-6Y vs KFFP2-22
Cable TypeVoltage & Temp.Oil / Acid & Crush RatingPrimary Feeder Duty
FEP/PFA-GSWB (this page)0.6/1 kV, +200 °CThermal-oil/solvent immune + GSWB impact braidMelt pumps, steelworks, glass kilns & hot hydraulic zones
PFA-SSWB (this page)0.6/1 kV, +260 °CAcid/alkali immune + 316 stainless steel braid260 °C chemical reactors, pickling lines & HPAL autoclaves
SiHF-GL-P (Silicone + GSWB)300/500 V, +180 °CGood dry heat; silicone swells in hot oils/acidsDry foundry auxiliaries without chemical or ester-oil splash
KFFP2-22 (FLU09)450/750 V, +200/+260 °CSteel tape armour for control cores <= 6 mm²Multi-core control & CT circuits (not heavy motor power)

Always apply high-ambient current derating factors when sizing 0.6/1 kV motor feeders routed through +100 °C to +220 °C furnace zones.

FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Feeder RFQ Checklist

  • Core count and cross-section (for example 4G4, 4G10, 4G25 or 5G6 mm²) plus motor kW / full-load current and ambient air temperature.
  • Thermal/polymer tier: FEP/PFA-GSWB (+200 °C with tinned/silver Cu) or PFA-SSWB (+260 °C with 27 % nickel-plated Cu).
  • Armour configuration: exposed galvanized GSWB, exposed 304/316 stainless SSWB, or fluoropolymer-oversheathed (-F) for acid washdown.
  • Required drum length (MOQ 300 m per cross-section, 7 to 45 working days).

Related selection resources

FEP/PFA-GSWB & PFA-SSWB Armoured Power Cable FAQ

Why specify FEP/PFA-GSWB or PFA-SSWB instead of armoured silicone (SiHF-GL-P) power cable?

2 decisive advantages: true 0.6/1 kV (3,500 V AC test) motor feeder insulation up to +260 °C, and complete chemical immunity to synthetic thermal oils (Dowtherm/Therminol), hydraulic esters, concentrated acids and caustic washdowns that rapidly swell and degrade silicone rubber.

When should I choose 316 stainless steel braid (PFA-SSWB) over galvanized steel braid (FEP/PFA-GSWB)?

Choose 304/316 stainless steel wire braid (PFA-SSWB, optionally with an outer PFA jacket) whenever hydrochloric/sulfuric acid mist, salt spray or caustic CIP washdown would corrode zinc-galvanized steel wire.

Which conductor plating is used on +260 °C PFA-SSWB 0.6/1 kV power cables?

27 % nickel-plated Class 5 copper (NPC) is used for continuous +260 °C service so copper strands cannot oxidize inside high-current motor terminal boxes; use high-temperature nickel ring lugs during termination.

Can FEP/PFA-GSWB power cables feed VFD-driven hot-zone motors?

Yes — the >= 80 % metallic wire braid (especially when paired with a copper braid screen or concentric earth bond through 360-degree brass/stainless armoured glands) provides low-impedance high-frequency return paths for PWM inverter drives.

What is the minimum order quantity and manufacturing lead time for FEP/PFA-GSWB and PFA-SSWB?

300 m per cross-section on export drums is our standard factory MOQ, manufactured and tested at 3,500 V AC in 7 to 45 working days.

Specifications

FEP/PFA-GSWB (+200 °C) & PFA-SSWB (+260 °C) Schedules

FEP/PFA-GSWB Voltage, Ampacity, Armour & Drum Summary

  • True 0.6/1 kV motor feeder duty: 3,500 V AC 5-minute dielectric withstand rating engineered for 380–690 V AC melt pumps, kiln fans, autoclaves and immersion heaters
  • GSWB or 316 SSWB steel braid: Galvanized steel wire braid (FEP/PFA-GSWB) for impact/slag protection in steelworks, or 304/316 stainless braid (PFA-SSWB) for acid-washdown zones
  • All-fluoropolymer + glass barrier: FEP (+200 °C) or PFA (+260 °C) cores and inner sheath sealed beneath an E-glass thermal buffer prevent oil/acid swelling where N2GFAF silicone fails
  • Optional outer fluoropolymer jacket: Available with exposed metallic braid for maximum radiant heat dissipation or an extruded FEP/PFA outer oversheath for direct chemical immersion
  • 300 m EPC production drums: Supplied in 300 m minimum order continuous factory export drums across 3G1.5 to 4G35 mm² and 5G2.5 to 5G16 mm² in 7 to 45 working days
FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C) technical data
ParameterValue
Rated voltage0.6/1 kV AC (600/1000 V, Um 1.2 kV) per IEC 60502-1 with 3500 V AC 5-minute routine dielectric withstand test
Conductor and core range3G1.5 mm2 to 4G35 mm2 and 5G2.5 mm2 to 5G16 mm2 in IEC 60228 Class 5 tinned, silver-plated or nickel-plated copper
Fluoropolymer and armour tiersFEP/PFA-GSWB (+200 C FEP + galvanized steel braid) and PFA-SSWB (+260 C PFA + 304/316 stainless steel wire braid, optional outer PFA sheath)
Operating temperature and bend radius-60 C (-90 C fixed) to +200 C (FEP) or +260 C continuous (PFA with NPC); 10x OD fixed and 15x OD flexing minimum bend radius
Standard put-up and lead time300 m minimum order continuous factory export drums delivered in 7 to 45 working days
Chemical and oil immunityImpervious to synthetic heat-transfer oils, hydraulic fluids, concentrated acids, caustic washdowns, solvents, ozone and molten slag splash
Flame performanceSelf-extinguishing and flame-retardant per IEC 60332-1-2 and bunched vertical tray test IEC 60332-3-24

FEP/PFA-GSWB 0.6/1 kV (+200 °C) Galvanized Steel-Braided Power Schedule

FEP/PFA-GSWB 0.6/1 kV (+200 °C FEP + Galvanized Steel Wire Braid) High-Temperature Power Cable — Dimensional & Ampacity Schedule
Model & Cross-SectionConductor PlatingInner Sheath / ArmourNom. OD (mm)Ref. Ampacity at +150 °C Air (A)Min. Fixed BendApprox. Weight (kg/km)Standard Drum MOQNext step
FEP/PFA-GSWB 3G1.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB8.61810x OD138300 m drumRequest this size
FEP/PFA-GSWB 4G1.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB9.41610x OD168300 m drumRequest this size
FEP/PFA-GSWB 5G1.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB10.31610x OD202300 m drumRequest this size
FEP/PFA-GSWB 3G2.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB9.82510x OD192300 m drumRequest this size
FEP/PFA-GSWB 4G2.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB10.82210x OD238300 m drumRequest this size
FEP/PFA-GSWB 5G2.5 mm²Class 5 TPC/SPCFEP + Glass + GSWB11.82210x OD286300 m drumRequest this size
FEP/PFA-GSWB 4G4.0 mm²Class 5 TPC/SPCFEP + Glass + GSWB12.43010x OD335300 m drumRequest this size
FEP/PFA-GSWB 5G4.0 mm²Class 5 TPC/SPCFEP + Glass + GSWB13.63010x OD408300 m drumRequest this size
FEP/PFA-GSWB 4G6.0 mm²Class 5 TPC/SPCFEP + Glass + GSWB14.23910x OD465300 m drumRequest this size
FEP/PFA-GSWB 4G10 mm²Class 5 TPC/SPCFEP + Glass + GSWB17.45410x OD735300 m drumRequest this size
FEP/PFA-GSWB 4G16 mm²Class 5 TPC/SPCFEP + Glass + GSWB20.47210x OD1,065300 m drumRequest this size
FEP/PFA-GSWB 4G25 mm²Class 5 TPC/SPCFEP + Glass + GSWB24.69610x OD1,590300 m drumRequest this size
FEP/PFA-GSWB 4G35 mm²Class 5 TPC/SPCFEP + Glass + GSWB27.811810x OD2,140300 m drumRequest this size

PFA-SSWB 0.6/1 kV (+260 °C) Stainless Steel-Braided Power Schedule

PFA-SSWB 0.6/1 kV (+260 °C PFA + 304/316 Stainless Steel Wire Braid) Extreme-Temp Chemical Power Cable Schedule
Model & Cross-SectionConductor PlatingInner Sheath / ArmourContinuous Temp.Nom. OD (mm)Approx. Weight (kg/km)Standard Drum MOQNext step
PFA-SSWB 4G2.5 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C10.8245300 m drumRequest this size
PFA-SSWB 4G4.0 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C12.4345300 m drumRequest this size
PFA-SSWB 4G6.0 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C14.2478300 m drumRequest this size
PFA-SSWB 5G6.0 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C15.6580300 m drumRequest this size
PFA-SSWB 4G10 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C17.4752300 m drumRequest this size
PFA-SSWB 5G16 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C22.51,310300 m drumRequest this size
PFA-SSWB 4G25 mm²Class 5 NPC (27 % Ni)PFA + Glass + 316 SSWB-90 to +260 °C24.61,625300 m drumRequest this size

ASCII part references for BOM entry: TF-FEP-GSWB-3G25, TF-FEP-GSWB-4G40, TF-FEP-GSWB-4G10, TF-FEP-GSWB-4G16, TF-FEP-GSWB-4G35, TF-PFA-SSWB-4G40, TF-PFA-SSWB-4G10, TF-PFA-SSWB-F-4G16.

Add suffix -F (for example PFA-SSWB-F 4G10) when an extruded outer FEP or PFA chemical oversheath over the steel wire braid is required for direct acid washdown.

Standards

FEP/PFA-GSWB IEC 60502-1, IEC 60228 & Flame Standards

FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C) standards and test references
Standard or specificationApplication
IEC 60502-1 (0.6/1 kV Power Architecture)Phase-to-earth (0.6 kV) and phase-to-phase (1.0 kV) insulation geometry and 3,500 V AC 5-minute dielectric withstand testing.
IEC 60228 & HD 308 S2Class 5 flexible plated copper conductor resistance and 3/4/5-core phase + protective-earth colour coding.
IEC 60332-1-2 & IEC 60332-3-24Single-cable and bunched vertical ladder flame-retardant performance.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 3,500 V AC 0.6/1 kV routine test reports

IEC 60502-1 — Power cables with extruded insulation for rated voltages of 1 kV (Um = 1.2 kV)

IEC 60228 — Conductors of insulated cables

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.