FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C)
FEP/PFA-GSWB and stainless-steel-braided PFA-SSWB 0.6/1 kV high-temperature armoured power cables (TF-FEP-PFA-GSWB-1KV) combine IEC 60228 Class 5 plated copper conductors, FEP (+200 °C) or PFA (+260 °C) insulation and inner sheathing, a woven E-glass thermal barrier and galvanized (GSWB) or 304/316 stainless steel wire braid (SSWB). Built for 3G1.5 to 4G35 mm² hot-zone and acid-plant motor feeders on 300 m drums.
FEP/PFA-GSWB and stainless PFA-SSWB 0.6/1 kV steel-wire-braided fluoropolymer power cables protect three-phase motor and heater feeders where +200 °C to +260 °C radiant heat coincides with mechanical impact, metal splatter or corrosive chemical splash, spanning 3G1.5 mm² auxiliary drives up to 4G35 mm² and 5G16 mm² heavy industrial feeders.
In steel continuous-casting spray chambers, aluminum smelters, glass furnaces, polymer melt-pump skids and HPAL / SX-EW acid-leach plants, armoured N2GFAF / SiHF-GL-P silicone power cables absorb hot hydraulic ester oils, synthetic heat-transfer fluids and acid fumes until their elastomer walls soften and split. Replacing silicone rubber with melt-extruded FEP (+200 °C) or PFA (+260 °C) beneath an E-glass thermal cushion and >= 80 % steel wire braid delivers dual chemical and mechanical survival across multi-year furnace campaigns.
Select galvanized steel braided FEP/PFA-GSWB for dry foundry, furnace, kiln and glass-plant catwalks, or select 304/316L stainless braided PFA-SSWB (with optional extruded PFA outer chemical jacket) for wet pickling tanks, offshore chemical skids and washdown reactors. Every production drum undergoes routine 3,500 V AC 5-minute dielectric testing (MOQ 300 m per size, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Cable Construction
Engineered to IEC 60502-1 0.6/1 kV voltage geometry using high-temperature plated Class 5 copper, pinhole-free fluoropolymer extrusion and high-tensile steel braiding.

| Component | Material and construction |
|---|---|
| 1. Plated Flexible Copper Conductors (IEC 60228 Class 5) | Fine-stranded tinned copper (up to +180/+200 °C on FEP-GSWB), silver-plated copper (up to +205/+250 °C) or 27 % nickel-plated copper (up to +260 °C continuous on PFA-SSWB). |
| 2. 0.6/1 kV Extruded FEP or PFA Core Insulation (HD 308 S2) | Thick-wall fluoropolymer phase insulation colour-coded per HD 308 S2 (brown, black, grey + green/yellow protective earth on G builds) or numbered black cores. |
| 3. Extruded Fluoropolymer Inner Sheath & E-Glass Thermal Buffer | Impervious FEP or PFA inner sheath seals the core assembly against fluids, wrapped with woven alkali-free E-glass tape to cushion clamping and radiant heat. |
| 4. Galvanized (GSWB) or 304/316 Stainless Steel Wire Braid (SSWB) | Dense >= 80 % coverage abrasion/rodent/impact steel wire braid armour (optional outer translucent/black FEP or PFA oversheath on -F builds). |
FEP/PFA-GSWB & PFA-SSWB Code Breakdown
- FEP / PFA: 0.6/1 kV fluoropolymer insulation & inner sheath: FEP (+200 °C) or PFA (+260 °C)
- GSWB: Galvanized steel wire braid armour (>= 80 % coverage) for dry impact & slag zones
- SSWB: 304 / 316L stainless steel wire braid armour for acid mist, washdown & marine/chemical skids
- -F (Optional): Extruded outer FEP or PFA chemical oversheath over the metallic steel braid
- 3G / 4G / 5G: Core count including green/yellow protective earth conductor per HD 308 S2
FEP/PFA-GSWB Melt-Pump, Smelter & Acid-Plant Applications
Built for heavy-industry 380 V / 400 V / 480 V / 690 V AC power distribution where unarmoured fluoropolymer or armoured silicone cables fail.

- Polymer spinning & extrusion melt-pump drives, thermal-oil (Dowtherm / Therminol) circulation pumps and high-pressure reactor agitator motors.
- Steel pickling & hot-dip galvanizing drive motors, continuous-casting run-out roller tables, ladle transfer cars and billet reheat furnace fans.
- HPAL nickel-cobalt autoclave feed pumps, phosphoric/sulfuric acid transfer skids, chlor-alkali cell-room auxiliaries and chemical incinerator blowers.
- Industrial electric resistance immersion heaters, flange process heaters, glass-lehr heating zones and autoclave air-circulation blowers.
FEP/PFA-GSWB & PFA-SSWB vs SiHF-GL-P vs KFFP2-22
| Cable Type | Voltage & Temp. | Oil / Acid & Crush Rating | Primary Feeder Duty |
|---|---|---|---|
| FEP/PFA-GSWB (this page) | 0.6/1 kV, +200 °C | Thermal-oil/solvent immune + GSWB impact braid | Melt pumps, steelworks, glass kilns & hot hydraulic zones |
| PFA-SSWB (this page) | 0.6/1 kV, +260 °C | Acid/alkali immune + 316 stainless steel braid | 260 °C chemical reactors, pickling lines & HPAL autoclaves |
| SiHF-GL-P (Silicone + GSWB) | 300/500 V, +180 °C | Good dry heat; silicone swells in hot oils/acids | Dry foundry auxiliaries without chemical or ester-oil splash |
| KFFP2-22 (FLU09) | 450/750 V, +200/+260 °C | Steel tape armour for control cores <= 6 mm² | Multi-core control & CT circuits (not heavy motor power) |
Always apply high-ambient current derating factors when sizing 0.6/1 kV motor feeders routed through +100 °C to +220 °C furnace zones.
FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Feeder RFQ Checklist
- Core count and cross-section (for example 4G4, 4G10, 4G25 or 5G6 mm²) plus motor kW / full-load current and ambient air temperature.
- Thermal/polymer tier: FEP/PFA-GSWB (+200 °C with tinned/silver Cu) or PFA-SSWB (+260 °C with 27 % nickel-plated Cu).
- Armour configuration: exposed galvanized GSWB, exposed 304/316 stainless SSWB, or fluoropolymer-oversheathed (-F) for acid washdown.
- Required drum length (MOQ 300 m per cross-section, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer & Armoured Cables
- Pair with KFFP / KFFP2-22 Control & DJFPFP Computer Cables
- Compare Unarmoured FEP-6Y & Copper-Screened FEP-C-6Y Cable
- Compare 300/500 V SiHF-P / SiHF-GL-P Steel-Braided Silicone Cable
- Engineering guide: Silicone vs FEP vs PFA high-temperature boundaries
FEP/PFA-GSWB & PFA-SSWB Armoured Power Cable FAQ
Why specify FEP/PFA-GSWB or PFA-SSWB instead of armoured silicone (SiHF-GL-P) power cable?
2 decisive advantages: true 0.6/1 kV (3,500 V AC test) motor feeder insulation up to +260 °C, and complete chemical immunity to synthetic thermal oils (Dowtherm/Therminol), hydraulic esters, concentrated acids and caustic washdowns that rapidly swell and degrade silicone rubber.
When should I choose 316 stainless steel braid (PFA-SSWB) over galvanized steel braid (FEP/PFA-GSWB)?
Choose 304/316 stainless steel wire braid (PFA-SSWB, optionally with an outer PFA jacket) whenever hydrochloric/sulfuric acid mist, salt spray or caustic CIP washdown would corrode zinc-galvanized steel wire.
Which conductor plating is used on +260 °C PFA-SSWB 0.6/1 kV power cables?
27 % nickel-plated Class 5 copper (NPC) is used for continuous +260 °C service so copper strands cannot oxidize inside high-current motor terminal boxes; use high-temperature nickel ring lugs during termination.
Can FEP/PFA-GSWB power cables feed VFD-driven hot-zone motors?
Yes — the >= 80 % metallic wire braid (especially when paired with a copper braid screen or concentric earth bond through 360-degree brass/stainless armoured glands) provides low-impedance high-frequency return paths for PWM inverter drives.
What is the minimum order quantity and manufacturing lead time for FEP/PFA-GSWB and PFA-SSWB?
300 m per cross-section on export drums is our standard factory MOQ, manufactured and tested at 3,500 V AC in 7 to 45 working days.
FEP/PFA-GSWB (+200 °C) & PFA-SSWB (+260 °C) Schedules
FEP/PFA-GSWB Voltage, Ampacity, Armour & Drum Summary
- True 0.6/1 kV motor feeder duty: 3,500 V AC 5-minute dielectric withstand rating engineered for 380–690 V AC melt pumps, kiln fans, autoclaves and immersion heaters
- GSWB or 316 SSWB steel braid: Galvanized steel wire braid (FEP/PFA-GSWB) for impact/slag protection in steelworks, or 304/316 stainless braid (PFA-SSWB) for acid-washdown zones
- All-fluoropolymer + glass barrier: FEP (+200 °C) or PFA (+260 °C) cores and inner sheath sealed beneath an E-glass thermal buffer prevent oil/acid swelling where N2GFAF silicone fails
- Optional outer fluoropolymer jacket: Available with exposed metallic braid for maximum radiant heat dissipation or an extruded FEP/PFA outer oversheath for direct chemical immersion
- 300 m EPC production drums: Supplied in 300 m minimum order continuous factory export drums across 3G1.5 to 4G35 mm² and 5G2.5 to 5G16 mm² in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 0.6/1 kV AC (600/1000 V, Um 1.2 kV) per IEC 60502-1 with 3500 V AC 5-minute routine dielectric withstand test |
| Conductor and core range | 3G1.5 mm2 to 4G35 mm2 and 5G2.5 mm2 to 5G16 mm2 in IEC 60228 Class 5 tinned, silver-plated or nickel-plated copper |
| Fluoropolymer and armour tiers | FEP/PFA-GSWB (+200 C FEP + galvanized steel braid) and PFA-SSWB (+260 C PFA + 304/316 stainless steel wire braid, optional outer PFA sheath) |
| Operating temperature and bend radius | -60 C (-90 C fixed) to +200 C (FEP) or +260 C continuous (PFA with NPC); 10x OD fixed and 15x OD flexing minimum bend radius |
| Standard put-up and lead time | 300 m minimum order continuous factory export drums delivered in 7 to 45 working days |
| Chemical and oil immunity | Impervious to synthetic heat-transfer oils, hydraulic fluids, concentrated acids, caustic washdowns, solvents, ozone and molten slag splash |
| Flame performance | Self-extinguishing and flame-retardant per IEC 60332-1-2 and bunched vertical tray test IEC 60332-3-24 |
FEP/PFA-GSWB 0.6/1 kV (+200 °C) Galvanized Steel-Braided Power Schedule
| Model & Cross-Section | Conductor Plating | Inner Sheath / Armour | Nom. OD (mm) | Ref. Ampacity at +150 °C Air (A) | Min. Fixed Bend | Approx. Weight (kg/km) | Standard Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| FEP/PFA-GSWB 3G1.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 8.6 | 18 | 10x OD | 138 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G1.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 9.4 | 16 | 10x OD | 168 | 300 m drum | Request this size |
| FEP/PFA-GSWB 5G1.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 10.3 | 16 | 10x OD | 202 | 300 m drum | Request this size |
| FEP/PFA-GSWB 3G2.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 9.8 | 25 | 10x OD | 192 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G2.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 10.8 | 22 | 10x OD | 238 | 300 m drum | Request this size |
| FEP/PFA-GSWB 5G2.5 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 11.8 | 22 | 10x OD | 286 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G4.0 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 12.4 | 30 | 10x OD | 335 | 300 m drum | Request this size |
| FEP/PFA-GSWB 5G4.0 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 13.6 | 30 | 10x OD | 408 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G6.0 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 14.2 | 39 | 10x OD | 465 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G10 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 17.4 | 54 | 10x OD | 735 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G16 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 20.4 | 72 | 10x OD | 1,065 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G25 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 24.6 | 96 | 10x OD | 1,590 | 300 m drum | Request this size |
| FEP/PFA-GSWB 4G35 mm² | Class 5 TPC/SPC | FEP + Glass + GSWB | 27.8 | 118 | 10x OD | 2,140 | 300 m drum | Request this size |
PFA-SSWB 0.6/1 kV (+260 °C) Stainless Steel-Braided Power Schedule
| Model & Cross-Section | Conductor Plating | Inner Sheath / Armour | Continuous Temp. | Nom. OD (mm) | Approx. Weight (kg/km) | Standard Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| PFA-SSWB 4G2.5 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 10.8 | 245 | 300 m drum | Request this size |
| PFA-SSWB 4G4.0 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 12.4 | 345 | 300 m drum | Request this size |
| PFA-SSWB 4G6.0 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 14.2 | 478 | 300 m drum | Request this size |
| PFA-SSWB 5G6.0 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 15.6 | 580 | 300 m drum | Request this size |
| PFA-SSWB 4G10 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 17.4 | 752 | 300 m drum | Request this size |
| PFA-SSWB 5G16 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 22.5 | 1,310 | 300 m drum | Request this size |
| PFA-SSWB 4G25 mm² | Class 5 NPC (27 % Ni) | PFA + Glass + 316 SSWB | -90 to +260 °C | 24.6 | 1,625 | 300 m drum | Request this size |
ASCII part references for BOM entry: TF-FEP-GSWB-3G25, TF-FEP-GSWB-4G40, TF-FEP-GSWB-4G10, TF-FEP-GSWB-4G16, TF-FEP-GSWB-4G35, TF-PFA-SSWB-4G40, TF-PFA-SSWB-4G10, TF-PFA-SSWB-F-4G16.
Add suffix -F (for example PFA-SSWB-F 4G10) when an extruded outer FEP or PFA chemical oversheath over the steel wire braid is required for direct acid washdown.
FEP/PFA-GSWB IEC 60502-1, IEC 60228 & Flame Standards
| Standard or specification | Application |
|---|---|
| IEC 60502-1 (0.6/1 kV Power Architecture) | Phase-to-earth (0.6 kV) and phase-to-phase (1.0 kV) insulation geometry and 3,500 V AC 5-minute dielectric withstand testing. |
| IEC 60228 & HD 308 S2 | Class 5 flexible plated copper conductor resistance and 3/4/5-core phase + protective-earth colour coding. |
| IEC 60332-1-2 & IEC 60332-3-24 | Single-cable and bunched vertical ladder flame-retardant performance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 3,500 V AC 0.6/1 kV routine test reports
IEC 60502-1 — Power cables with extruded insulation for rated voltages of 1 kV (Um = 1.2 kV)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
YGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)
A related cable option for a different application or duty profile.
View productTF-PYRO-SM 0.6/1 kV Slag-Splash Protected Pyrojacketed EAF & Steel-Mill Power/Control Cable (+260 / +1,090 °C)
A related cable option for a different application or duty profile.
View productKFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.