MINING & TUNNELING CABLES TEBAOFLEX

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn (2–144F) Armoured Underground Mine Fibre Optic Cable

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn and YOTKGtsFtlyn form the Polish-standard armoured loose-tube underground mine fibre optic cable family (2 to 144 fibres) with a 2.5 mm FRP central strength member, gel-filled 2.4 mm loose tubes, dry water-swelling tape, black PVC inner sheath, galvanized round steel wire (Foyn, 1.54 mm) or lacquered steel tape (Ftlyn, 0.3 mm) armour, and a blue flame-retardant PVC outer sheath.

Product information
SKU
PL-YOTKGTS-ARMOURED-FO
Brand
TEBAOFLEX
Product overview

Permanent optical backbones in underground coal, copper and salt mines must survive rock fall, rodent attack, longitudinal water migration and, in vertical pit shafts, high self-weight tension. The YOTKGts family covers four armoured loose-tube constructions with blue flame-retardant PVC outer sheaths, distinguished by their armour geometry (Foyn round steel wires vs Ftlyn lacquered steel tape) and aramid reinforcement (letter D).

Every variant strands gel-filled 2.4 mm loose tubes (first tube red, second blue, remaining natural; black fillers where needed) in 6-, 8- or 12-element lay-ups around a 2.5 mm fibre-reinforced plastic (FRP) central rod, wrapped in dry water-swelling tape tested to IEC 60794-1-2-F5B (1 m sample, 1 m water head, 24 h) under a black PVC inner sheath. YOTKGtsDFoyn and YOTKGtsFoyn (both to TT1-1764/2/0, 2–144 fibres) apply a full layer of 1.54 mm galvanized round steel wires for vertical pit shaft and horizontal roadway installation; adding aramid yarns in YOTKGtsDFoyn raises dynamic pulling tension from 6000–10000 N to 8000–12000 N.

Where rodent and crush protection is needed in lighter ducts or galleries, YOTKGtsDFtlyn (TT1-1837/2/0, 4–72F, 4000 N dynamic / 2000 N static) and YOTKGtsFtlyn (TT1-1506/2/0, 2–72F, 310 kg/km, 2500 N dynamic / 1250 N static) use 0.3 mm lacquered steel tape armour. Note the strict installation boundary: YOTKGtsDFoyn, YOTKGtsFoyn and YOTKGtsDFtlyn are rated for both horizontal roadways and vertical pit shafts, whereas YOTKGtsFtlyn (TT1-1506/2/0) is designated exclusively for horizontal installation.

Explore the mining and tunneling cable range for related configurations.

Construction

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn Cable Construction

The representative horizontal sample shows YOTKGtsDFoyn 4-72F (6 elements, 17.9 mm O.D.): a 2.5 mm FRP central strength rod surrounded by six 2.4 mm gel-filled loose tubes (first red, second blue, others natural), water-swelling tape, aramid yarns, a 1.0 mm black PVC inner sheath, 1.54 mm galvanized round steel armour wires and a 1.5 mm blue flame-retardant PVC outer sheath.

Flat 2D cross-section diagram of YOTKGtsDFoyn armoured mine fibre optic cable showing central FRP rod, six 2.4 mm gel-filled loose tubes, swelling tape, aramid reinforcement, black PVC inner sheath, round galvanized steel wire armour and blue PVC-FR outer sheath
YOTKGtsDFoyn cross-section: FRP central rod, six 2.4 mm loose tubes, aramid yarns, steel wire armour and blue PVC sheath.
YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn (2–144F) Armoured Underground Mine Fibre Optic Cable construction
ComponentMaterial and construction
Central FRP Strength MemberStraight fibre-reinforced plastic (FRP) dielectric rod, 2.5 mm diameter (with plastic oversheathing when required by the lay-up).
Gel-Filled Loose Tubes (2.4 mm)Thixotropic gel-filled loose tubes (PBT on Ftlyn types) housing ITU-T G.652D fibres colour-coded to IEC 60304; first tube red, second blue, remaining natural, passive fillers black.
Dry Water-Swelling Tape & Aramid (D Types)Interstitial water-swelling tape (approx. 0.20 to 0.25 mm) blocking longitudinal water ingress to IEC 60794-1-2-F5B, plus dielectric aramid yarns on D-designated builds.
Black PVC Inner SheathExtruded black PVC inner bedding: nominal 1.0 mm (min. 0.8 mm) on YOTKGtsDFoyn and YOTKGtsDFtlyn; nominal 1.4 mm (min. 1.2 mm) on YOTKGtsFoyn and YOTKGtsFtlyn.
Round Steel Wire (Foyn) or Steel Tape (Ftlyn) ArmourFoyn types: galvanized round steel wires of 1.54 mm diameter. Ftlyn types: lacquered steel tape of 0.3 mm thickness (0.30 x 20 mm on YOTKGtsFtlyn).
Blue Flame-Retardant PVC Outer SheathSelf-extinguishing blue PVC-FR outer jacket: nominal 1.5 mm (min. spot 1.3 mm) on DFoyn, Foyn and DFtlyn; average 1.70 mm on YOTKGtsFtlyn.

YOTKGtsDFoyn and YOTKGtsFtlyn Type Designation Breakdown

  • YO: PVC-sheathed optical (optotelekomunikacyjny) cable
  • TK: telecommunication loose-tube core (2.4 mm gel-filled tubes around 2.5 mm FRP rod)
  • G: mining (gorniczy) duty
  • ts: dry swelling-tape longitudinal water barrier (IEC 60794-1-2-F5B)
  • D: dielectric aramid yarn reinforcement (on YOTKGtsDFoyn and YOTKGtsDFtlyn)
  • Foyn / Ftlyn: galvanized round steel wire armour (Foy) or lacquered steel tape armour (Ftl) with blue flame-retardant PVC sheath (yn)
Applications

YOTKGtsDFoyn, YOTKGtsFoyn & YOTKGtsFtlyn Mine Shaft & Roadway Applications

Match the YOTKGts suffix to shaft vs horizontal routing and required pulling tension.

Blue-sheathed YOTKGtsDFoyn steel-wire-armoured fibre optic cable clamped vertically down an underground mine pit shaft
YOTKGtsDFoyn armoured fibre optic cable installed in an underground mine shaft.
  • Vertical pit shaft optical backbones and steep inclines requiring 1.54 mm galvanized round steel wire armour and up to 12000 N dynamic / 5000 N static tensile load (YOTKGtsDFoyn and YOTKGtsFoyn).
  • Medium-tension shaft and main haulageway optical trunks up to 72 fibres using aramid-reinforced lacquered steel tape armour (YOTKGtsDFtlyn).
  • Horizontal underground mine roadways, drifts and surface-to-underground ducts up to 72 fibres where 2500 N dynamic tension and lacquered steel tape rodent/crush protection suffice (YOTKGtsFtlyn).
  • High-voltage substation and conveyor telemetry routes requiring dielectric optical cores immune to electromagnetic interference.

YOTKGtsDFoyn Family vs ZW-(QG)GNOTKSdD Selection Boundary

YOTKGts armoured variants compared with non-metallic mine fibre optic cables
ModelArmour & reinforcementMax. dynamic / static pullInstallation scope
YOTKGtsDFoyn (this page)1.54 mm round steel wires + aramid + FRP rod8000 to 12000 N / 3000 to 5000 NVertical pit shafts and horizontal roadways (2-144F)
YOTKGtsFoyn (this page)1.54 mm round steel wires + FRP rod6000 to 10000 N / 3000 to 5000 NVertical pit shafts and horizontal roadways (2-144F)
YOTKGtsDFtlyn (this page)0.3 mm lacquered steel tape + aramid + FRP rod4000 N / 2000 NVertical shafts and horizontal galleries (4-72F)
YOTKGtsFtlyn (this page)0.30 x 20 mm lacquered steel tape + FRP rod2500 N / 1250 NHorizontal mine installation only (2-72F)
ZW-(QG)GNOTKSdDNon-metallic FRP rods (1.0 mm) + aramid, TPR/PU sheaths6000 N / 4000 NHorizontal, vertical and moving parts of machines (4-8F)

Do not substitute horizontal-only YOTKGtsFtlyn (TT1-1506/2/0) into a vertical pit shaft; specify YOTKGtsDFoyn, YOTKGtsFoyn or YOTKGtsDFtlyn for vertical shaft suspension.

Related selection resources

YOTKGtsDFoyn, YOTKGtsFoyn and YOTKGtsFtlyn Frequently Asked Questions

What is the difference between YOTKGtsDFoyn and YOTKGtsFoyn?

Both are built to TT1-1764/2/0 with 1.54 mm galvanized round steel wire armour and a blue PVC-FR outer sheath in 4-72F (6 elements), 28-96F (8 elements) and 36-144F (12 elements). YOTKGtsDFoyn adds dielectric aramid yarn reinforcement over a 1.0 mm inner sheath, increasing dynamic tensile capacity to 8000, 10000 and 12000 N (versus 6000, 8000 and 10000 N on YOTKGtsFoyn, which uses a 1.4 mm inner sheath).

Can YOTKGtsFtlyn be installed vertically in a mine pit shaft?

No. Under works standard TT1-1506/2/0, YOTKGtsFtlyn (2-72F, 2500 N dynamic / 1250 N static) is rated solely for horizontal installation in mines. For vertical pit shafts, specify round-wire-armoured YOTKGtsDFoyn or YOTKGtsFoyn (up to 12000 N / 5000 N) or aramid-reinforced tape-armoured YOTKGtsDFtlyn (TT1-1837/2/0, 4000 N / 2000 N).

Why do the dimensional tables list 4-72F, 28-96F and 36-144F while the family header states 2-144 fibres?

The 6-, 8- and 12-element core geometries accommodate 1 to 12 fibres per 2.4 mm loose tube (replacing unused positions with black passive fillers), so a 2-fibre build uses the same 6-element outer diameter and mechanical schedule as the 4-72F row.

How are loose tubes and optical fibres colour-coded inside YOTKGts cables?

The first loose tube is red, the second tube is blue, remaining active tubes are natural and any dummy filler rods are black. Individual fibres inside each tube follow the 12-colour IEC 60304 sequence: red, green, blue, white, violet, orange, grey, yellow, brown, pink, black and turquoise.

Specifications

YOTKGtsDFoyn Family Dimensions, Tensile Ratings & Technical Specifications

YOTKGtsDFoyn Family Key Specifications

  • Wire-armoured (Foyn): YOTKGtsDFoyn (with aramid, 8000-12000 N) & YOTKGtsFoyn (6000-10000 N), 2-144F, 1.54 mm steel wires, vertical shaft & horizontal
  • Tape-armoured (Ftlyn): YOTKGtsDFtlyn (4-72F, 4000/2000 N, shaft/horizontal) & YOTKGtsFtlyn (2-72F, 2500/1250 N, horizontal only)
  • Core & water blocking: 2.5 mm FRP central rod, gel-filled 2.4 mm loose tubes (red, blue, natural), dry swelling tape (IEC 60794-1-2-F5B)
  • Sheath system: Black PVC inner sheath (1.0-1.4 mm) and blue self-extinguishing PVC-FR outer sheath (1.5-1.7 mm)
  • Temperatures: Installation -15 °C to +60 °C; operating -40 °C to +70 °C (+75 °C on YOTKGtsDFtlyn)
YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn (2–144F) Armoured Underground Mine Fibre Optic Cable technical data
ParameterValue
Construction referencesYOTKGtsDFoyn & YOTKGtsFoyn to TT1-1764/2/0; YOTKGtsDFtlyn to TT1-1837/2/0; YOTKGtsFtlyn to TT1-1506/2/0
Fibre & element counts2 to 144 fibres across 6, 8 or 12 elements (DFoyn/Foyn); 4 to 72F in 6 elements (DFtlyn); 2 to 72F in 6 elements (Ftlyn)
Optical attenuation (G.652D)Max. 0.4 dB/km at 1310 nm and 0.25 dB/km at 1550 nm (DFoyn, Foyn, DFtlyn); max. 0.5 / 0.35 dB/km (Ftlyn)
Tensile load ratings (dynamic / static)DFoyn: 8000-12000 / 3000-5000 N; Foyn: 6000-10000 / 3000-5000 N; DFtlyn: 4000 / 2000 N; Ftlyn: 2500 / 1250 N
Temperatures & water tightnessInstallation -15 °C to +60 °C; operation -40 °C to +70 °C (+75 °C on DFtlyn); water penetration to IEC 60794-1-2-F5B
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing
Selection boundary vs PSKD and ZW-(QG)GNOTKSdDChoose YOTKGtsDFoyn, YOTKGtsFoyn or YOTKGtsDFtlyn for fixed armoured shaft and roadway backbones (and YOTKGtsFtlyn for horizontal-only armoured runs); choose PSKD for portable tactical reels and ZW-(QG)GNOTKSdD for non-metallic flexible machine cables.

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn Dimensional & Tensile Schedule

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn — Dimensional, Tensile & Bending Radius Schedule
Variant & Fibre RangeTube O.D. (mm)Elements (Tubes/Fillers)Outer Diameter (mm)Cable Weight (kg/km)Max. Dynamic Tensile Load (N)Max. Static Tensile Load (N)Min. Dynamic Bend Radius (mm)Min. Static Bend Radius (mm)Next step
YOTKGtsDFoyn 4-72F (6 elements)2.4617.9+/-0.262080003000360540Request this size
YOTKGtsDFoyn 28-96F (8 elements)2.4819.0+/-0.2740100004000380570Request this size
YOTKGtsDFoyn 36-144F (12 elements)2.41221.9+/-0.21000120005000450680Request this size
YOTKGtsFoyn 4-72F (6 elements)2.4618.2+/-0.263060003000370550Request this size
YOTKGtsFoyn 28-96F (8 elements)2.4819.2+/-0.276080004000385580Request this size
YOTKGtsFoyn 36-144F (12 elements)2.41222.1+/-0.21020100005000460690Request this size
YOTKGtsDFtlyn 4-72F (6 elements)2.4615.1+/-2Confirmed on drawing40002000300225Request this size
YOTKGtsFtlyn 2-72F (6 elements, horizontal only)2.4615.131025001250300230Request this size

YOTKGts Armoured Family Construction & Installation Matrix

YOTKGts Armoured Mine Fibre Optic Family — Construction & Installation Boundary Matrix
DesignationWorks StandardStrength & ReinforcementArmour ConstructionInner / Outer PVC SheathsMax. Attenuation 1310 / 1550 nmPermitted Mine Installation
YOTKGtsDFoyn (2-144F)TT1-1764/2/0FRP rod 2.5 mm + aramid yarnsGalvanized round steel wires 1.54 mmBlack PVC 1.0 mm nom. / Blue PVC-FR 1.5 mm nom.0.4 / 0.25 dB/kmHorizontal roadways and vertical pit shafts
YOTKGtsFoyn (2-144F)TT1-1764/2/0FRP rod 2.5 mmGalvanized round steel wires 1.54 mmBlack PVC 1.4 mm nom. / Blue PVC-FR 1.5 mm nom.0.4 / 0.25 dB/kmHorizontal roadways and vertical pit shafts
YOTKGtsDFtlyn (4-72F)TT1-1837/2/0FRP rod 2.5 mm + aramid yarnsLacquered steel tape 0.3 mmBlack PVC 1.0 mm nom. / Blue PVC 1.5 mm nom.0.4 / 0.25 dB/kmHorizontal roadways and vertical pit shafts
YOTKGtsFtlyn (2-72F)TT1-1506/2/0FRP rod 2.5 mm (aramid noted in text)Lacquered steel tape 0.30 x 20 mmBlack PVC 1.4 mm nom. / Blue PVC 1.70 mm avg.0.5 / 0.35 dB/kmHorizontal mine installation only (not for shafts)

In the TT1-1837/2/0 table for YOTKGtsDFtlyn (4-72F), the catalogue prints outer diameter 15.1+/-2 mm and omits the numeric mass cell (confirmed on the quotation drawing; compare 310 kg/km on 15.1 mm YOTKGtsFtlyn). On YOTKGtsFtlyn (TT1-1506/2/0), the static bending radius is 230 mm and dynamic bending radius is 300 mm, and installation is restricted to horizontal routes.

Polish and Central European designations and the TT1 / ZN works specifications are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.

ASCII part references for BOM and ERP entry: YOTKGtsDFoyn 4-72F, YOTKGtsDFoyn 28-96F, YOTKGtsDFoyn 36-144F, YOTKGtsFoyn 4-72F, YOTKGtsFoyn 28-96F, YOTKGtsFoyn 36-144F, YOTKGtsDFtlyn 4-72F, YOTKGtsFtlyn 2-72F.

Standards

YOTKGtsDFoyn Family Standards & Test References (TT1-1764/2/0, TT1-1837/2/0, TT1-1506/2/0)

YOTKGtsDFoyn, YOTKGtsFoyn, YOTKGtsDFtlyn & YOTKGtsFtlyn (2–144F) Armoured Underground Mine Fibre Optic Cable standards and test references
Standard or specificationApplication
TT1-1764/2/0Works construction specification for YOTKGtsDFoyn and YOTKGtsFoyn 2-144F round-steel-wire-armoured mine fibre optic cables.
TT1-1837/2/0 & TT1-1506/2/0Works specifications for YOTKGtsDFtlyn (4-72F shaft/horizontal) and YOTKGtsFtlyn (2-72F horizontal-only) steel-tape-armoured mine fibre optic cables.
IEC 60794-1-2-F5BLongitudinal water penetration test (1 m sample, 1 m water head, 24 hours) verified on the swelling-tape sealed core.
ITU-T G.652D & IEC 60304Single-mode optical fibre transmission specification and 12-colour fibre identification code.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 60794-1-2-F5B water penetration and IEC 60304 optical fibre colour code publications (international references)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.