Get a Quote

Aircraft GPU, bridge, apron and fixed ground power systems

Airport Ground Power Cable Solutions for GPU, FEGP & PCA

Design the cable around the aircraft interface, current, route length and handling system. This solution connects 400Hz and 28VDC ground power duties to GPU carts, passenger boarding bridges, FEGP, PCA, reels, retrievers and aircraft connectors.

  • 400Hz AC and 28VDC
  • GPU, FEGP, PCA and bridge
  • Reel, retriever and connector
Airport ground power cables for aircraft GPU and bridge systems

Choose by system duty, not by name alone

Use this page to narrow the cable route before comparing a product model or submitting a specification.

Start with the equipment

Identify the machine, circuit function, route and the consequence of cable failure at that location.

Define the complete duty

State voltage or transmission needs together with movement, bending, load, fluids, temperature and installation exposure.

Confirm one construction

Review conductor or fibre elements, screens, reinforcement, sheath, termination, standards and documentation as one schedule.

Match the cable to the equipment and route

The correct cable assembly depends on where power is converted, how the cable reaches the aircraft and how often operators extend, retract, drag or reel it across the apron.

Mobile GPU carts

Flexible 400Hz or 28VDC connections handled on the apron, exposed to dragging, fuel, weather and vehicle activity.

Passenger boarding bridges

Cable assemblies integrated with bridge movement, cable retrievers and aircraft parking positions.

Fixed electrical ground power

FEGP and frequency-converter routes that combine feeder, service cable, connector and voltage-drop requirements.

PCA and combined bridge systems

Power and pre-conditioned air equipment routes where cable movement, storage and service access must be coordinated.

Cable reels and retrievers

Repeated winding duty defined by drum diameter, cable weight, layers, speed, bend radius and pull force.

Hangar and maintenance areas

Ground power and grounding routes for indoor or semi-exposed maintenance positions and service equipment.

Define the conditions that control cable life

Airport ground power cable is a system component. Voltage drop, connector temperature, cable handling and the reel or retriever can be as important as the nominal 400Hz or 28VDC rating.

Current and voltage drop

Confirm aircraft load, cable length, conductor size, phase balance, sense wires and allowable voltage at the connector.

Handling and storage

Define dragging, banded or single-jacket construction, reel, basket, retriever and minimum bend radius.

Connector interface

State aircraft plug type, molded or replaceable design, control contacts, interlock and termination arrangement.

Apron environment

Check fuel, oil, abrasion, UV, water, cold, heat, vehicle traffic and visibility or marking needs.

Compare suitable cable-family routes

Select AC or DC service first, then define the cable geometry, connector, handling system, control conductors and environmental resistance.

400Hz aircraft GPU cables

Flexible AC ground power routes from mobile or fixed converters to aircraft, checked for load, length and connector interface.

View 400Hz aircraft cable

28VDC ground power cables

High-current DC service cable for aircraft and GSE, selected around voltage drop, conductor size and connector temperature.

View 28VDC cable

Cable assemblies and connectors

Complete cable-and-plug routes with specified length, aircraft connector, control contacts and field service needs.

View GPU cable assembly

Banded and single-jacket cable

Alternative handling constructions selected by flexibility, repair strategy, weight, abrasion and airport operating practice.

View Tripleflex cable

Drum and retriever cables

Cable constructions for repeated reel or retriever cycles on bridges and fixed ground power equipment.

View retriever cable

Feeder and static installation

Fixed or semi-fixed routes between electrical equipment and service points, separated from the flexible aircraft connection.

View 400Hz feeder cable

Turn the application into a cable selection route

Use the matrix to identify the next technical route. Final construction follows the complete project schedule and operating inputs.

Equipment or RouteCable SystemInputs to ConfirmSelection Route
Mobile aircraft GPU400Hz or 28VDC flexible service cableAC/DC, aircraft load, cable length, plug, dragging, fuel and weatherGPU cable family
Passenger boarding bridge400Hz assembly with retrieverBridge travel, retriever force, connector, storage, length and control contactsDrum/retriever cable
Fixed ground power systemFeeder plus aircraft service cableConverter location, feeder route, voltage drop, service length and connectorFEGP cable system
400Hz cable assemblyComplete cable and aircraft connectorCurrent, phase/core arrangement, plug style, molded end, controls and length400Hz assembly
28VDC aircraft serviceHeavy-current DC cableCurrent, length, conductor size, polarity, connector and heat rise28VDC cable
Aircraft groundingGrounding or refueling cableConductor, clamp, reel, length, abrasion and site procedureGrounding cable

Engineering and test references

References are selected for the confirmed construction and project duty. The quotation and inspection plan define the applicable methods, conditions and acceptance values.

Reference 1

Aircraft and GSE interface requirements checked against the connector, converter and airport equipment specification.

Reference 2

400Hz conductor layout, control contacts and voltage-drop limits confirmed with the system designer or tender.

Reference 3

Flame, low-smoke, oil, abrasion and weather requirements applied only where the exact cable construction supports them.

Reference 4

Inspection, marking, connector and assembly test documents agreed before production.

From operating data to an agreed cable schedule

The process keeps equipment, cable construction, interfaces and documentation aligned before production.

Share the operating duty

Provide the equipment, electrical or transmission services, movement, route and environment.

Review the cable route

Separate circuit functions and compare the constructions that fit the operating duty.

Confirm the technical schedule

Agree the construction, dimensions, interfaces, standards, inspection stages and document list.

Manufacture and inspect

Production, marking, packing and agreed inspection follow the confirmed order specification.

Frequently asked questions

Short answers to common questions before a project-specific cable review.

Is a 400 Hz aircraft cable the same as a 28 VDC ground cable?

No. They serve different electrical systems and are selected around the aircraft interface, voltage, current, conductor arrangement, length, connector and handling method.

Why does cable length matter for aircraft ground power?

Cable length affects voltage drop, resistance, weight and handling. The current, conductor size, ambient conditions, bundling and connection interfaces should be reviewed together.

How do reels and retrievers affect cable construction?

Drum diameter, bend radius, winding layers, travel, tension and repeated handling influence conductor flexibility, reinforcement and jacket selection.

What should be sent for a GPU or FEGP cable review?

Provide the aircraft or equipment interface, 400 Hz or DC service, voltage, current, cable length, conductor arrangement, connector, reel or bridge system, temperature, abrasion and fluid exposure, quantity and required documents.

Send the inputs needed for a useful cable review

Include the information available now. Drawings, old cable markings, cross-section photos and project specifications can be attached through the enquiry form.

  • Service: 400Hz AC, 28VDC or another specified aircraft ground power system
  • Aircraft load, voltage, current, allowable voltage drop and duty cycle
  • Cable length, conductor size, core arrangement, control cores and sense wires
  • Configuration: single jacket, banded, symmetrical, feeder, reel or retriever
  • Aircraft connector or plug type, molded or replaceable end and control contacts
  • GPU cart, bridge, FEGP, PCA, apron, hangar, reel or drum installation
  • PUR, rubber, LSOH, fuel, oil, abrasion, UV, water and temperature requirements
  • Quantity, assembly test, marking, packing, delivery country and document list