(N)GRDGCGOEU-J 0.6/1 kV Screened Festoon Cable
(N)GRDGCGOEU-J screened festoon cable is a 0.6/1 kV overall-screened round rubber cable for crane festoon systems and flexible motor connections where power-cable emissions can interfere with nearby data circuits.
- Conductor: flexible bare copper; split protective-earth conductors from 16 mm²
- Insulation: high-grade EPR compound
- Overall screen: tinned-copper wire braid with more than 80% coverage
- Outer sheath: black PCP rubber compound 5GM3
- Converter connection: source reference up to 690 V AC
- Festoon speed: source reference up to 240 m/min
Send the exact core arrangement, route geometry, drive data, length and required documentation for quotation.
(N)GRDGCGOEU-J Screened Festoon Cable for FC and VFD Drives
(N)GRDGCGOEU-J is a 0.6/1 kV overall-screened round festoon cable for moving power connections on gantry cranes, indoor cranes, material-handling equipment, transport systems and machine tools. Buyers also search the model as NGRDGCGOEU-J and NGRDGCGÖU-J. Its tinned-copper braid surrounds the inner sheath, providing an EMC-oriented construction where motor-power routes can disturb adjacent control or data cables.
The family covers four-core sizes up to 10 mm² and three main-conductor layouts with split protective-earth conductors from 16 mm². TEBAOFLEX can manufacture the listed configurations after the application, cable route and final production drawing have been technically confirmed.
- Best fit: supported festoon loops and flexible motor-supply routes requiring an overall copper screen.
- Confirm the earth layout: four-core construction is used through 10 mm²; larger sizes use three main cores with the protective conductor divided into three parts.
- Check the complete EMC route: screen termination, bonding and gland arrangement affect system performance.
- Choose another cable when: the route involves continuous torsion, powered-drum reeling or an unscreened control circuit.
Compare other options in the Port & Festoon Cable range, or use the crane cable selection guide to distinguish festoon, reeling and spreader duty.
(N)GRDGCGOEU-J Cable Construction
The overall-screened construction combines flexible rubber-insulated power conductors with a copper braid over the inner sheath. This arrangement separates the screen from the individual power cores and provides a continuous EMC layer around the cable assembly.

| Element | Construction | Buyer relevance |
|---|---|---|
| Main conductor | Bare electrolytic copper, finely stranded, class 5 | Flexible conductor construction for repeated festoon bending. |
| Protective-earth conductor | Tinned, extremely finely stranded copper, class FS; green/yellow identification | Confirm the earth cross-section and termination arrangement with the selected size. |
| Insulation | High-grade EPR compound, source-listed as at least GI3 | Rubber insulation for the verified low-voltage construction. |
| Core arrangement | Up to 10 mm²: four-core design. From 16 mm²: three main conductors with the protective conductor split into three parts in the interstices | Prevents a shorthand “3C” enquiry from omitting the required split earth conductors. |
| Inner sheath | Black EPR rubber compound GM1b | Forms the bedding below the overall screen. |
| Overall screen | Tinned-copper wire braid, more than 80% surface coverage; transfer impedance below 100 mΩ/m at frequencies up to 30 MHz | Requires a compatible screen-bonding and gland plan. |
| Outer sheath | Black PCP rubber compound 5GM3 | Source-listed for outdoor and industrial festoon service. |
Applications for (N)GRDGCGOEU-J Screened Festoon Cable
The cable is intended for supported festoon systems exposed to frequent bending and high mechanical stress, particularly where a nearby data or control route could be affected by emissions from the motor-power cable.

- Gantry and hall-crane trolley power systems
- Rack and general material-handling equipment
- Transportation systems and movable machine tools
- Flexible motor power supplies connected to frequency converters
- Festoon routes requiring an overall copper screen for EMC control
Route and EMC checks before ordering
Confirm the trolley system, loop length, available space, supported cable weight, speed, acceleration and minimum bend radius. The screen must be coordinated with the gland, bonding and protective-earth design. Torsional stress is not allowed. For unscreened power, multicore control or screened-pair bus configurations, compare the (N)GRDGOEU-J/-O round festoon cable. For festoon operation, the source specifically advises against using cross-sections above 3 × 50 mm² without application review.
(N)GRDGCGOEU-J Specifications and Exact Sizes
The following ratings and dimensions are the common values confirmed across the matching screened festoon references. Every size row includes the complete model designation so that a buyer can distinguish the orderable construction from a shorthand such as “3C × 25 mm²”.
| Parameter | Verified value |
|---|---|
| Rated voltage U₀/U | 0.6/1 kV |
| Maximum permissible operating voltage, AC | 0.7/1.2 kV |
| Maximum permissible operating voltage, DC | 0.9/1.8 kV |
| AC test voltage | 5 kV for 5 minutes |
| Peak voltage | 2400 V |
| Maximum AC voltage for frequency-converter connection | 690 V |
| Maximum conductor temperature | +90 °C |
| Maximum short-circuit conductor temperature | +250 °C |
| Ambient temperature, fixed installation | −50 to +80 °C |
| Ambient temperature, fully flexible operation | −35 to +80 °C |
| Maximum tensile load on conductor | 15 N/mm² |
| Torsional stress | Not allowed |
| Minimum bending radius | According to DIN VDE 0298-3 |
| Festoon travel speed | Up to 240 m/min; review the complete system above this speed |
Dimensions and EMC reference data
| Exact model and configuration | Outer Ø min.–max. (mm) | Min. free-moving bend radius (mm) | Approx. weight (kg/km) | Operating capacitance (µF/km) | Nominal inductance (mH/km) | Current capacity in free air (A) | Transfer impedance at 1 / 10 / 30 MHz (mΩ/m) |
|---|---|---|---|---|---|---|---|
| (N)GRDGCGOEU-J 4 × 2.5 mm² | 13.0–15.0 | 75 | 340 | 0.170 | 0.580 | 32 | Not listed |
| (N)GRDGCGOEU-J 4 × 4 mm² | 14.8–17.8 | 89 | 480 | 0.180 | 0.550 | 43 | Not listed |
| (N)GRDGCGOEU-J 4 × 6 mm² | 16.2–19.2 | 96 | 640 | 0.190 | 0.530 | 56 | Not listed |
| (N)GRDGCGOEU-J 4 × 10 mm² | 19.6–22.6 | 113 | 890 | 0.230 | 0.510 | 78 | 0.4 / 1.3 / 3.5 |
| (N)GRDGCGOEU-J 3 × 16 + 3 × 2.5 mm² | 22.4–25.4 | 127 | 1150 | 0.225 | 0.480 | 104 | 0.2 / 0.6 / 1.5 |
| (N)GRDGCGOEU-J 3 × 25 + 3 × 4 mm² | 25.4–28.4 | 142 | 1590 | 0.275 | 0.450 | 138 | 0.2 / 0.4 / 1.3 |
| (N)GRDGCGOEU-J 3 × 35 + 3 × 6 mm² | 29.3–32.3 | 162 | 2160 | 0.325 | 0.430 | 170 | 0.1 / 0.4 / 0.9 |
| (N)GRDGCGOEU-J 3 × 50 + 3 × 10 mm² | 35.4–38.4 | 192 | 3060 | 0.400 | 0.410 | 212 | 0.1 / 0.2 / 0.7 |
| (N)GRDGCGOEU-J 3 × 70 + 3 × 10 mm² | 40.8–43.8 | 219 | 3960 | 0.475 | 0.390 | 263 | 0.1 / 0.2 / 0.5 |
| (N)GRDGCGOEU-J 3 × 95 + 3 × 16 mm² | 43.4–46.4 | 232 | 4840 | 0.600 | 0.375 | 316 | 0.1 / 0.2 / 0.4 |
| (N)GRDGCGOEU-J 3 × 120 + 3 × 16 mm² | 47.8–50.8 | 254 | 5910 | 0.700 | 0.360 | 370 | 0.1 / 0.1 / 0.3 |
| (N)GRDGCGOEU-J 3 × 150 + 3 × 25 mm² | 54.6–57.6 | 288 | 7540 | Not listed | Not listed | 424 | Not listed |
Current capacities are source-listed references for rubber cables installed free in air at 30 °C ambient. Dimensions and weights are approximate. For festoon use, configurations above 3 × 50 mm² require specific application review.
Standards and Reference Performance
The matching source catalogues list the following standards, test methods and approval references for the (N)GRDGCGOEU-J construction.
| Item | Source-listed reference |
|---|---|
| Product design | Based on DIN VDE 0250-814 |
| Current-carrying capacity | DIN VDE 0298-4 |
| Minimum bending radius | DIN VDE 0298-3 |
| Oil resistance | DIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10 |
| EMC application reference | Power-cable emission control in installations evaluated against EN 55011 / EN 55022 |
| Approvals listed in matching reference | VDE Reg. No. 7841; GOST-R |
| Additional source-listed test | Bending test |
Include the required standard edition, approval documentation, test scope, cable marking and inspection requirements in the purchase enquiry.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)GRDGOEU-J/-O 0.6/1 kV Round Festoon Cable
A related cable option for a different application or duty profile.
View productNGFLGOEU Flat Festoon Cable 300/500V
A related cable option for a different application or duty profile.
View productFestoonflex PUR-HF Cable 0.6/1 kV for Cranes and Moving Equipment
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.