Get a Quote
Port & Festoon Cables TEBAOFLEX

(N)GRDGCGOEU-J 0.6/1 kV Screened Festoon Cable

(N)GRDGCGOEU-J screened festoon cable is a 0.6/1 kV overall-screened round rubber cable for crane festoon systems and flexible motor connections where power-cable emissions can interfere with nearby data circuits.

  • Conductor: flexible bare copper; split protective-earth conductors from 16 mm²
  • Insulation: high-grade EPR compound
  • Overall screen: tinned-copper wire braid with more than 80% coverage
  • Outer sheath: black PCP rubber compound 5GM3
  • Converter connection: source reference up to 690 V AC
  • Festoon speed: source reference up to 240 m/min

Send the exact core arrangement, route geometry, drive data, length and required documentation for quotation.

Product information
Brand
TEBAOFLEX
Product overview

(N)GRDGCGOEU-J Screened Festoon Cable for FC and VFD Drives

(N)GRDGCGOEU-J is a 0.6/1 kV overall-screened round festoon cable for moving power connections on gantry cranes, indoor cranes, material-handling equipment, transport systems and machine tools. Buyers also search the model as NGRDGCGOEU-J and NGRDGCGÖU-J. Its tinned-copper braid surrounds the inner sheath, providing an EMC-oriented construction where motor-power routes can disturb adjacent control or data cables.

The family covers four-core sizes up to 10 mm² and three main-conductor layouts with split protective-earth conductors from 16 mm². TEBAOFLEX can manufacture the listed configurations after the application, cable route and final production drawing have been technically confirmed.

  • Best fit: supported festoon loops and flexible motor-supply routes requiring an overall copper screen.
  • Confirm the earth layout: four-core construction is used through 10 mm²; larger sizes use three main cores with the protective conductor divided into three parts.
  • Check the complete EMC route: screen termination, bonding and gland arrangement affect system performance.
  • Choose another cable when: the route involves continuous torsion, powered-drum reeling or an unscreened control circuit.

Compare other options in the Port & Festoon Cable range, or use the crane cable selection guide to distinguish festoon, reeling and spreader duty.

Construction

(N)GRDGCGOEU-J Cable Construction

The overall-screened construction combines flexible rubber-insulated power conductors with a copper braid over the inner sheath. This arrangement separates the screen from the individual power cores and provides a continuous EMC layer around the cable assembly.

(N)GRDGCGOEU-J cable cross-section showing three power cores, split PE conductors and tinned-copper braid
Flat cross-section illustrating the large-size three-power-core and split-PE arrangement; final dimensions follow the approved drawing.
Verified (N)GRDGCGOEU-J construction
ElementConstructionBuyer relevance
Main conductorBare electrolytic copper, finely stranded, class 5Flexible conductor construction for repeated festoon bending.
Protective-earth conductorTinned, extremely finely stranded copper, class FS; green/yellow identificationConfirm the earth cross-section and termination arrangement with the selected size.
InsulationHigh-grade EPR compound, source-listed as at least GI3Rubber insulation for the verified low-voltage construction.
Core arrangementUp to 10 mm²: four-core design. From 16 mm²: three main conductors with the protective conductor split into three parts in the intersticesPrevents a shorthand “3C” enquiry from omitting the required split earth conductors.
Inner sheathBlack EPR rubber compound GM1bForms the bedding below the overall screen.
Overall screenTinned-copper wire braid, more than 80% surface coverage; transfer impedance below 100 mΩ/m at frequencies up to 30 MHzRequires a compatible screen-bonding and gland plan.
Outer sheathBlack PCP rubber compound 5GM3Source-listed for outdoor and industrial festoon service.
Applications

Applications for (N)GRDGCGOEU-J Screened Festoon Cable

The cable is intended for supported festoon systems exposed to frequent bending and high mechanical stress, particularly where a nearby data or control route could be affected by emissions from the motor-power cable.

(N)GRDGCGOEU-J screened festoon cable used on a gantry crane cable-trolley system
Supported round-cable festoon loops on a gantry crane; trolley layout, loop geometry and movement data must be confirmed for each system.
  • Gantry and hall-crane trolley power systems
  • Rack and general material-handling equipment
  • Transportation systems and movable machine tools
  • Flexible motor power supplies connected to frequency converters
  • Festoon routes requiring an overall copper screen for EMC control

Route and EMC checks before ordering

Confirm the trolley system, loop length, available space, supported cable weight, speed, acceleration and minimum bend radius. The screen must be coordinated with the gland, bonding and protective-earth design. Torsional stress is not allowed. For unscreened power, multicore control or screened-pair bus configurations, compare the (N)GRDGOEU-J/-O round festoon cable. For festoon operation, the source specifically advises against using cross-sections above 3 × 50 mm² without application review.

Specifications

(N)GRDGCGOEU-J Specifications and Exact Sizes

The following ratings and dimensions are the common values confirmed across the matching screened festoon references. Every size row includes the complete model designation so that a buyer can distinguish the orderable construction from a shorthand such as “3C × 25 mm²”.

General electrical, mechanical and thermal data
ParameterVerified value
Rated voltage U₀/U0.6/1 kV
Maximum permissible operating voltage, AC0.7/1.2 kV
Maximum permissible operating voltage, DC0.9/1.8 kV
AC test voltage5 kV for 5 minutes
Peak voltage2400 V
Maximum AC voltage for frequency-converter connection690 V
Maximum conductor temperature+90 °C
Maximum short-circuit conductor temperature+250 °C
Ambient temperature, fixed installation−50 to +80 °C
Ambient temperature, fully flexible operation−35 to +80 °C
Maximum tensile load on conductor15 N/mm²
Torsional stressNot allowed
Minimum bending radiusAccording to DIN VDE 0298-3
Festoon travel speedUp to 240 m/min; review the complete system above this speed

Dimensions and EMC reference data

(N)GRDGCGOEU-J exact screened festoon cable configurations
Exact model and configurationOuter Ø min.–max. (mm)Min. free-moving bend radius (mm)Approx. weight (kg/km)Operating capacitance (µF/km)Nominal inductance (mH/km)Current capacity in free air (A)Transfer impedance at 1 / 10 / 30 MHz (mΩ/m)
(N)GRDGCGOEU-J 4 × 2.5 mm²13.0–15.0753400.1700.58032Not listed
(N)GRDGCGOEU-J 4 × 4 mm²14.8–17.8894800.1800.55043Not listed
(N)GRDGCGOEU-J 4 × 6 mm²16.2–19.2966400.1900.53056Not listed
(N)GRDGCGOEU-J 4 × 10 mm²19.6–22.61138900.2300.510780.4 / 1.3 / 3.5
(N)GRDGCGOEU-J 3 × 16 + 3 × 2.5 mm²22.4–25.412711500.2250.4801040.2 / 0.6 / 1.5
(N)GRDGCGOEU-J 3 × 25 + 3 × 4 mm²25.4–28.414215900.2750.4501380.2 / 0.4 / 1.3
(N)GRDGCGOEU-J 3 × 35 + 3 × 6 mm²29.3–32.316221600.3250.4301700.1 / 0.4 / 0.9
(N)GRDGCGOEU-J 3 × 50 + 3 × 10 mm²35.4–38.419230600.4000.4102120.1 / 0.2 / 0.7
(N)GRDGCGOEU-J 3 × 70 + 3 × 10 mm²40.8–43.821939600.4750.3902630.1 / 0.2 / 0.5
(N)GRDGCGOEU-J 3 × 95 + 3 × 16 mm²43.4–46.423248400.6000.3753160.1 / 0.2 / 0.4
(N)GRDGCGOEU-J 3 × 120 + 3 × 16 mm²47.8–50.825459100.7000.3603700.1 / 0.1 / 0.3
(N)GRDGCGOEU-J 3 × 150 + 3 × 25 mm²54.6–57.62887540Not listedNot listed424Not listed

Current capacities are source-listed references for rubber cables installed free in air at 30 °C ambient. Dimensions and weights are approximate. For festoon use, configurations above 3 × 50 mm² require specific application review.

Standards

Standards and Reference Performance

The matching source catalogues list the following standards, test methods and approval references for the (N)GRDGCGOEU-J construction.

(N)GRDGCGOEU-J standards and test references
ItemSource-listed reference
Product designBased on DIN VDE 0250-814
Current-carrying capacityDIN VDE 0298-4
Minimum bending radiusDIN VDE 0298-3
Oil resistanceDIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10
EMC application referencePower-cable emission control in installations evaluated against EN 55011 / EN 55022
Approvals listed in matching referenceVDE Reg. No. 7841; GOST-R
Additional source-listed testBending test

Include the required standard edition, approval documentation, test scope, cable marking and inspection requirements in the purchase enquiry.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.