UL 3645 Covered Silicone Wire, 200°C 1000V
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
- Voltage: 1000 V AC
- Temperature: 150°C or 200°C by construction
- Insulation / covering: silicone rubber with a supplied glass-braid covering
- Size selection: 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG
- Certification: UL-certified AWM; UL 758
UL 3645 wire selection
UL 3645 is a UL-certified covered silicone wire rated 1000 V AC, with 150°C and 200°C constructions. The version shown here adds a fiberglass braid over the silicone insulation for internal appliance or electronic equipment wiring.
The 19-row size table spans 30 AWG through 4/0 AWG and identifies the nominal silicone wall, 0.16 mm glass covering and finished diameter for each listed construction. The outer braid is part of the finished size, so it must be included when checking sleeves, clamps and terminal entries. The separate style schedule covers additional conductor groups up to 750 kcmil without assigning unverified finished diameters to them.
Select the temperature grade and covering before comparing this wire with an uncovered silicone lead. The same AWG and voltage can still lead to a different outside diameter and stripping procedure. For the listed constructions, allow a bend radius of 10 times finished diameter and support the lead so the braid does not rub against sharp equipment edges.
See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare bare UL 3644 and the lower-voltage braided silicone wire family.
Construction
UL 3645 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Component | Construction detail |
|---|---|
| Conductor | Solid or stranded copper; dimensioned examples are stranded |
| Insulation | Extruded silicone rubber |
| Outer covering | Fiberglass braid; 0.16 mm in dimensioned examples |
Applications
UL 3645 is used for internal appliance and electronic equipment wiring that specifies a covering over silicone insulation. Review the braid finish and termination arrangement where the covering ends near a connector.

UL 3645 replacement selection
For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.
Specifications
| Parameter | Specification |
|---|---|
| UL style | UL 3645 |
| Voltage rating | 1000 V AC |
| Temperature rating | 150°C or 200°C by construction |
| Insulation / covering | silicone rubber with a supplied glass-braid covering |
| Conductor size coverage | 30 AWG–750 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Model and conductor size | Stranding (No./mm) | Nominal silicone wall (mm) | Glass covering (mm) | Nominal OD / tolerance (mm) |
|---|---|---|---|---|
| UL 3645 4/0 AWG | 2146/0.254 | 2.09 | 0.16 | 18.09 ±0.15 |
| UL 3645 3/0 AWG | 1615/0.254 | 2.09 | 0.16 | 16.30 ±0.15 |
| UL 3645 2/0 AWG | 1330/0.254 | 2.09 | 0.16 | 15.20 ±0.15 |
| UL 3645 1/0 AWG | 1026/0.254 | 2.09 | 0.16 | 13.90 ±0.15 |
| UL 3645 2 AWG | 665/0.254 | 1.58 | 0.16 | 11.05 ±0.15 |
| UL 3645 4 AWG | 420/0.254 | 1.58 | 0.16 | 9.50 ±0.15 |
| UL 3645 6 AWG | 259/0.254 | 1.58 | 0.16 | 8.21 ±0.15 |
| UL 3645 8 AWG | 161/0.254 | 1.58 | 0.16 | 7.20 ±0.15 |
| UL 3645 10 AWG | 105/0.254 | 1.20 | 0.16 | 5.73 ±0.15 |
| UL 3645 12 AWG | 65/0.254 | 1.20 | 0.16 | 5.09 ±0.15 |
| UL 3645 14 AWG | 41/0.254 | 1.20 | 0.16 | 4.60 ±0.15 |
| UL 3645 16 AWG | 26/0.254 | 1.20 | 0.16 | 4.22 ±0.15 |
| UL 3645 18 AWG | 34/0.18 | 1.20 | 0.16 | 3.94 ±0.15 |
| UL 3645 20 AWG | 21/0.18 | 1.20 | 0.16 | 3.68 ±0.15 |
| UL 3645 22 AWG | 17/0.16 | 1.20 | 0.16 | 3.49 ±0.15 |
| UL 3645 24 AWG | 11/0.16 | 1.20 | 0.16 | 3.34 ±0.15 |
| UL 3645 26 AWG | 7/0.16 | 1.20 | 0.16 | 3.21 ±0.15 |
| UL 3645 28 AWG | 7/0.127 | 1.20 | 0.16 | 3.11 ±0.15 |
| UL 3645 30 AWG | 7/0.10 | 1.20 | 0.16 | 3.03 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3645 30–10 AWG | 45 | 40 |
| UL 3645 8–2 AWG | 60 | 54 |
| UL 3645 1–4/0 AWG | 80 | 72 |
| UL 3645 250–500 kcmil | 95 | 85 |
| UL 3645 501–750 kcmil | 110 | 99 |
Selecting the specified construction
Specify UL 3645 with size, temperature grade and fiberglass covering. Match the covered finished diameter to clamps and sleeves instead of using a bare-silicone dimension.
Standards
TEBAOFLEX UL 3645 wire is UL-certified appliance wiring material.
| Item | Requirement or reference |
|---|---|
| Certification | UL-certified AWM |
| Style designation | UL 3645 |
| Construction standard | UL 758 — Appliance Wiring Material |
| Style flame classification | Horizontal flame |
Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.