SEOOW Cable 600 V TPE Portable Power Cord
600 V portable cord with Class K copper conductors, TPE insulation and an oil-resistant TPE jacket. Size schedule covers 18–10 AWG with two- to six-conductor configurations.
SEOOW cable is a 600 V flexible portable power cord with thermoplastic elastomer insulation and an overall TPE jacket. It supplies portable tools, small motors, appliances and industrial equipment where the cable must combine flexible handling with resistance to oil, moisture and abrasion.
The conductor construction uses Class K stranded bare copper. The size schedule covers 18–10 AWG, including two-, three-, four- and five-conductor arrangements, plus a six-conductor 12 AWG configuration. Conductor colours identify the circuit functions, with a green grounding conductor in the configurations of three or more conductors shown.
The selected construction has a temperature range of -50°C to +105°C. TPE insulation and sheathing distinguish SEOOW from thermoset-rubber SOOW portable cable. Compare the materials and operating conditions together when choosing between the two families, especially where the route includes repeated handling, oil exposure or outdoor use.
Use the nominal diameter and weight table to check connection space and cable handling, and use the stated current-rating conditions when sizing the circuit. Severe quarry or mining duty calls for a dedicated heavy-duty cable selection. Send the AWG size, conductor count, cable length, jacket colour and equipment conditions for a TEBAOFLEX quotation tailored to the connection.
Explore the industrial cable range for related configurations.
When comparing 600 V SEOOW thermoplastic elastomer (TPE) portable cord with thermoset rubber North American cords, evaluate these options: SOOW Cable 600V for Heavy-Duty Portable Power (600 V EPDM-insulated, CPE-jacketed thermoset cord for high-heat and heavy abrasion); SJOOW Cable 300V Portable Power Cable (300 V junior-service EPDM/CPE rubber cord for lighter portable hand tools and appliances). Match voltage rating, cold-temperature flexibility, and jacket material to your operating duty.
Construction
SEOOW uses TPE for both core insulation and the outer jacket. The illustration shows a representative three-conductor cord.

| Component | Material and construction |
|---|---|
| Conductor | Class K stranded soft-drawn bare copper to ASTM B174. |
| Insulation | Colour-coded thermoplastic elastomer (TPE). |
| Core colours | 2C: black/white. 3C: black/white/green. 4C: black/white/red/green. 5C: black/white/red/orange/green. 6C: black/white/red/orange/blue/green. |
| Outer jacket | Oil-, water-, moisture- and abrasion-resistant TPE; black, white or yellow. |
Applications
SEOOW portable cord is used for flexible equipment leads and temporary power connections within its electrical and environmental ratings.

- Portable tools, appliances and small motors.
- Industrial equipment and temporary indoor or outdoor power.
- Oil- and moisture-exposed equipment leads.
- For severe quarry or mining service, select a cable designed for that mechanical environment.
For portable cord letter nomenclature and European harmonized equivalents to 600 V SEOOW cordage, review these references: SOOW vs SJOOW vs SEOOW: What the Cord Letters Mean and Which to Specify (side-by-side breakdown of voltage class, TPE vs EPDM/CPE compounds, and temperature ratings); H05RN-F / H05RR-F Cable 300/500 V (300/500 V European harmonized rubber cable for export machinery and light portable equipment). Check AWG vs metric cross-section and plug compatibility before specifying.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage | 600 V |
| Temperature range | -50°C to +105°C |
| Conductor size schedule | 18–10 AWG |
| Conductor arrangements | 2, 3, 4 or 5 conductors; 6-conductor option at 12 AWG. |
| Insulation and jacket | TPE |
| Standard jacket colours | Black, white or yellow |
| Model and configuration | Stranding (No./AWG) | Nominal insulation thickness (mm) | Nominal jacket thickness (mm) | Nominal OD (mm) | Approx. weight (lb/1000 ft) | Reference current (A) |
|---|---|---|---|---|---|---|
| SEOOW 2C × 18 AWG | 16/30 | 0.76 | 1.52 | 8.69 | 54 | 10 |
| SEOOW 3C × 18 AWG | 16/30 | 0.76 | 1.52 | 9.19 | 64 | 10 |
| SEOOW 4C × 18 AWG | 16/30 | 0.76 | 1.52 | 9.83 | 79 | 7 |
| SEOOW 5C × 18 AWG | 16/30 | 0.76 | 2.03 | 11.73 | 108 | 7 |
| SEOOW 2C × 16 AWG | 26/30 | 0.76 | 1.52 | 9.32 | 62 | 13 |
| SEOOW 3C × 16 AWG | 26/30 | 0.76 | 1.52 | 9.83 | 77 | 13 |
| SEOOW 4C × 16 AWG | 26/30 | 0.76 | 1.52 | 10.54 | 91 | 10 |
| SEOOW 5C × 16 AWG | 26/30 | 0.76 | 2.03 | 12.50 | 128 | 8 |
| SEOOW 2C × 14 AWG | 41/30 | 1.14 | 2.03 | 12.62 | 114 | 18 |
| SEOOW 3C × 14 AWG | 41/30 | 1.14 | 2.03 | 13.26 | 140 | 18 |
| SEOOW 4C × 14 AWG | 41/30 | 1.14 | 2.03 | 14.35 | 166 | 15 |
| SEOOW 5C × 14 AWG | 41/30 | 1.14 | 2.41 | 16.31 | 214 | 12 |
| SEOOW 2C × 12 AWG | 65/30 | 1.14 | 2.41 | 14.48 | 153 | 25 |
| SEOOW 3C × 12 AWG | 65/30 | 1.14 | 2.41 | 15.04 | 185 | 25 |
| SEOOW 4C × 12 AWG | 65/30 | 1.14 | 2.41 | 16.31 | 227 | 20 |
| SEOOW 5C × 12 AWG | 65/30 | 1.14 | 2.41 | 17.96 | 280 | 16 |
| SEOOW 6C × 12 AWG | 65/30 | 1.14 | 2.41 | 18.92 | 335 | 14 |
| SEOOW 2C × 10 AWG | 104/30 | 1.14 | 2.41 | 15.67 | 196 | 30 |
| SEOOW 3C × 10 AWG | 104/30 | 1.14 | 2.41 | 16.56 | 245 | 30 |
| SEOOW 4C × 10 AWG | 104/30 | 1.14 | 2.41 | 17.83 | 301 | 25 |
| SEOOW 5C × 10 AWG | 104/30 | 1.14 | 2.41 | 19.35 | 358 | 20 |
Reference currents apply at 30°C ambient according to NEC Table 400.5(A) and CEC Table 12. A grounding conductor, or a conductor carrying only the unbalanced current of other conductors, is not counted as a current-carrying conductor.
Dimensions, thicknesses and weights are nominal. Weight is stated in lb/1000 ft. Specify AWG, conductor count, jacket colour and cable length for the required configuration.
Standards
| Standard or specification | Application |
|---|---|
| UL 62 | Flexible-cord construction reference. |
| CSA C22.2 No. 49 | Flexible cords and cables reference. |
| ASTM B174 | Class K copper conductor stranding. |
| ICEA S-58-679, Method 1, Table 1 | Conductor colour-code reference. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
SOOW Cable 600V for Heavy-Duty Portable Power
A related cable option for a different application or duty profile.
View productSJOOW Cable 300V Portable Power Cable
A related cable option for a different application or duty profile.
View productH05RN-F / H05RR-F Cable 300/500 V
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.