MINING & TUNNELING CABLES TEBAOFLEX

UGF & UGEFP High-Voltage Open-Pit Mining Trailing Cable (3.6/6–6/10 kV)

High-voltage flexible rubber trailing cables (UGF 3.6/6 kV, UGF 6/10 kV, UGEFP 3.6/6 kV and UGEFP 6/10 kV) engineered for open-pit mining electric rope shovels, hydraulic excavators, bucket-wheel excavators, rotary blast-hole drills and mobile transformers. Built with Class 5 tinned copper conductors, triple-extruded +90 °C EPR insulation, semiconductive or tinned-copper composite phase shields, an interstitial grounding core and a weather-, oil- and cold-resistant (-40 °C) chloroprene/CPE outer sheath.

Product information
Brand
TEBAOFLEX
Product overview

UGF and UGEFP high-voltage mining trailing cables are designed for surface and open-pit mining machinery operating on 3.6/6 kV and 6/10 kV three-phase distribution networks.Dragged over blasted haul-road rock, wound onto mobile cable skids or guided over boom sheaves on electric rope shovels and large blast-hole drills, these cables combine medium-voltage dielectric integrity with extreme mechanical impact, abrasion and cold-bend resilience.

In the standard UGF construction (3+1 cores, 16 mm² to 150 mm²), three Class 5 flexible tinned-copper power cores are insulated with +90 °C ethylene-propylene rubber (EPR) between extruded inner and outer semiconductive elastomer screens, laid up around a semiconductive rubber center cradle with an uninsulated flexible tinned-copper earth conductor in direct contact with the three phase screens.

In the metallic-shielded UGEFP construction, each power core adds an individual tinned-copper wire and synthetic-fibre composite metallic shield over the outer semiconductive layer, providing enhanced fault-current capacity and electrostatic screening for long open-pit feeder runs and variable-frequency shovel drives. Standard and cold-climate formulations operate across ambient temperatures down to -40 °C while resisting solar UV, ozone, oil and acid pit water.

Provide the rated voltage (3.6/6 kV or 6/10 kV), model (UGF or UGEFP), conductor cross-section, minimum ambient site temperature and coupler requirement with your enquiry. TEBAOFLEX manufactures custom lengths from a 50 m minimum order quantity with a standard lead time of 7–45 working days.

Explore the mining and tunneling cable range for related configurations.

For North American ICEA S-75-381 and Chinese MT 818 medium-voltage mining trailing cables, compare these constructions: SHD-GC Cable 2kV-25kV Mining Power Cable (for 2 kV to 25 kV braided-copper-shielded portable power feeds on open-pit shovels and draglines); MYPTJ Monitored Medium-Voltage Mining Trailing Cable (3.6/6–8.7/10 kV) (for 3.6/6 kV to 8.7/10 kV underground coal mining trailing service with semi-conductive screening and ground monitoring). Confirm rated voltage, minimum ambient operating temperature (-25°C vs -40°C), and earth-check architecture before ordering.

Construction

Construction

The representative construction illustrates UGEFP 6/10 kV 3×70 + 1×25 mm²: three equal Class 5 flexible tinned-copper power cores with inner semiconductive screen, +90 °C EPR medium-voltage insulation, outer semiconductive screen and tinned-copper composite metallic shield, plus one flexible tinned-copper earth conductor in the interstitial valley, cabled around a semiconductive profile center and enclosed in a light-grey inner bedding, reinforcing braid and heavy-duty black cold- and weather-resistant chloroprene/CPE outer sheath.

Cross-section of UGF and UGEFP 3.6/6–6/10 kV open-pit mining trailing cable with three triple-extruded screened EPR power cores, one interstitial tinned-copper ground wire and a braid-reinforced rubber outer sheath
Representative cable construction.
UGF & UGEFP High-Voltage Open-Pit Mining Trailing Cable (3.6/6–6/10 kV) construction
ComponentMaterial and construction
Power conductorsThree Class 5 flexible rope-lay stranded tinned copper conductors per GB/T 3956 / IEC 60228 (16 mm² to 150 mm²).
Conductor & insulation screensExtruded inner and outer semiconductive elastomer layers vulcanized integrally with the EPR dielectric.
High-voltage insulationOzone- and corona-resistant +90 °C ethylene-propylene rubber (EPR), 4.5 mm nominal wall thickness for 3.6/6 kV and 5.5 mm for 6/10 kV.
Phase shield (UGF vs. UGEFP)UGF: semiconductive elastomer phase screen in continuous contact with the interstitial earth conductor. UGEFP: tinned-copper wire and synthetic-yarn composite metallic shield over each power core.
Earth / grounding conductorOne flexible stranded tinned-copper grounding conductor (10 mm² to 50 mm²) laid in the interstitial valley.
Reinforcement & outer jacketElastomeric inner bedding, open-weave reinforcing braid and heavy-duty black polychloroprene (PCP/CR) or chlorinated polyethylene (CPE) outer jacket rated for -40 °C to +90 °C open-pit service.
Applications

Applications

Choose UGF for standard semiconductive-screened open-pit trailing service or UGEFP where individual metallic phase shielding is required by high-voltage earth-fault protection relays.

Open-pit surface mine bench showing a large electric mining shovel supplied by a heavy-duty black round UGF high-voltage trailing cable routed over a cable skid
Application illustration.
  • Open-pit mining electric rope shovels, walking draglines and large hydraulic face shovels operating at 6 kV or 10 kV.
  • High-voltage rotary blast-hole drill rigs, bucket-wheel excavators and mobile crusher units on surface mine benches.
  • Mobile skid-mounted substations and open-pit ring-main trailing feeders dragged across rock benches and haul-road cable bridges.
  • Cold-region surface mining operations down to -40 °C ambient temperature with minimum dynamic bending radius of 6 × D (UGF) to 10 × D (UGEFP).

When evaluating shielded high-voltage trailing cables for surface mines and quarries, consult these pages: What Does Type SHD Mean in Mining Cables? (for metallic shield construction, ground-check conductor placement, and voltage stress control principles); Type SHD-CGC 5 kV Shielded Portable Mining Power Cable (for 5 kV heavy-duty portable mining power feeds with a central ground-check conductor). Verify drag tension, rock impact exposure, and splice kit compatibility for your pit layout.

Specifications

Specifications

UGF & UGEFP High-Voltage Open-Pit Mining Trailing Cable (3.6/6–6/10 kV) technical data
ParameterValue
Rated voltage (U0/U)3.6/6 kV and 6/10 kV
Maximum continuous conductor temperature+90 °C (+250 °C short-circuit, 5 s max.)
Ambient operating temperature range-40 °C to +50 °C (cold-resistant open-pit compound)
Core configuration3 screened power cores + 1 interstitial grounding core (3+1)
Power frequency AC test voltage11 kV / 5 min (3.6/6 kV); 15 kV / 5 min (6/10 kV)
Minimum dynamic bending radius6 × cable outside diameter (UGF); 10 × cable outside diameter (UGEFP)
Sunlight, ozone and oil resistanceUV-stabilized, ozone-resistant and mineral-oil-resistant heavy-duty thermosetting rubber outer sheath
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7–45 working days
UGF & UGEFP 3.6/6 kV and 6/10 kV high-voltage open-pit mining trailing cable specifications
Model & voltage ratingNominal cross-section (power + earth, mm²)Nominal EPR insulation thickness (mm)Nominal outer sheath thickness (mm)Nominal outside diameter min–max (mm)Continuous ampacity at 25 °C ambient (A)Approx. weight — UGF / UGEFP (kg/km)
UGF / UGEFP-3.6/6 kV3×16 + 1×104.54.540.2 – 44.5852,180 / 2,390
UGF / UGEFP-3.6/6 kV3×25 + 1×164.54.543.6 – 48.21132,720 / 2,960
UGF / UGEFP-3.6/6 kV3×35 + 1×164.54.546.2 – 51.01383,210 / 3,480
UGF / UGEFP-3.6/6 kV3×50 + 1×164.55.050.8 – 56.01734,020 / 4,340
UGF / UGEFP-3.6/6 kV3×70 + 1×254.55.055.2 – 60.82155,040 / 5,410
UGF / UGEFP-3.6/6 kV3×95 + 1×254.55.560.8 – 66.82606,280 / 6,710
UGF / UGEFP-3.6/6 kV3×120 + 1×354.55.564.6 – 71.03007,450 / 7,920
UGF / UGEFP-3.6/6 kV3×150 + 1×504.56.070.2 – 77.03458,960 / 9,490
UGF / UGEFP-6/10 kV3×16 + 1×105.55.045.4 – 50.2852,640 / 2,880
UGF / UGEFP-6/10 kV3×25 + 1×165.55.048.8 – 53.81133,210 / 3,490
UGF / UGEFP-6/10 kV3×35 + 1×165.55.051.4 – 56.61383,740 / 4,050
UGF / UGEFP-6/10 kV3×50 + 1×165.55.556.2 – 61.81734,610 / 4,960
UGF / UGEFP-6/10 kV3×70 + 1×255.55.560.6 – 66.62155,680 / 6,090
UGF / UGEFP-6/10 kV3×95 + 1×255.56.066.2 – 72.82606,980 / 7,450
UGF / UGEFP-6/10 kV3×120 + 1×355.56.070.0 – 77.03008,190 / 8,710
UGF / UGEFP-6/10 kV3×150 + 1×505.56.575.6 – 83.23459,780 / 10,360

Continuous ampacities are stated for +90 °C conductor temperature at +25 °C ambient air; apply ambient temperature and solar radiation derating for exposed summer bench runs.

When UGF or UGEFP cables are operated on multi-layer mobile cable reels, apply standard wound-layer ampacity derating factors.

Custom split-earth (3+3) or integrated pilot-core variants can be manufactured to project specification.

Standards

Standards

UGF & UGEFP High-Voltage Open-Pit Mining Trailing Cable (3.6/6–6/10 kV) standards and test references
Standard or specificationApplication
JB/T 8137 / GB/T 12972High-voltage flexible rubber-sheathed trailing cables for open-pit mining shovels and mobile machinery (Types UGF and UGEFP).
GB/T 3956 / IEC 60228Class 5 flexible tinned copper conductors for mobile trailing cables.
IEC 60502-2Extruded solid dielectric (EPR) and semiconductive screening system reference for 6 kV and 10 kV cables.

IEC 60502-2 Medium-Voltage Cable Standard Reference

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.