RM-Series & EOM Torque-Balanced Steel-Armoured Work-Class ROV Main-Lift Umbilical Cable (1–4.5 kV)
RM-Series and EOM torque-balanced steel-armoured ROV main-lift umbilical cables (RM0049, RM0066, RM0037, RM0067, RM0060 and A304-series, 17.3 to 45.5 mm OD) integrate 1.0 to 4.5 kV medium-voltage copper power triads, shielded control pairs and hermetically sealed stainless-steel FIMT optical tubes beneath 2- or 3-layer contra-helical high-tensile galvanized steel wire armour rated 185 to 880 kN minimum breaking load.
RM-Series and EOM torque-balanced steel-armoured ROV main-lift umbilical cables (spanning RM0049 at 17.3 mm / 185 kN through RM0060 at 41.2 mm / 880 kN and A304562 at 45.5 mm / 845 kN) serve as the primary electro-opto-mechanical lifting line between vessel Launch and Recovery Systems (LARS) and deepwater Tether Management Systems (TMS) or free-swimming work-class vehicles down to 4,000–6,000 m.
In vertical deployment through harsh splash zones and active heave compensation (AHC) sheave cycling, an uncompensated single-lay wire rope spins under load, hockling conductors and snapping optical fibres when tension relaxes on the seabed. Each TEBAOFLEX EOM main-lift cable balances helical torque across opposing left- and right-hand layers of high-tensile galvanized improved plow steel (GIPS) or Zn-5Al alloy wire, pressure-injected with marine bitumen/grease blocking compound over a water-blocked polymeric inner jacket housing 3 to 20 medium-voltage copper power cores, shielded instrumentation pairs/quads and gel-filled stainless-steel Fiber-In-Metal-Tube (FIMT) assemblies.
Choose RM-Series and EOM bare steel-armoured main-lift umbilicals for high-tension traction or Lebus storage winches supporting heavy work-class ROV garages, subsea ploughs and salvage spreads. Where a companion flame-retardant topside jumper is also needed see our RS726 / FMBP Umbilical & Deck Cable page, or for neutral-buoyancy cage-to-vehicle excursion tethers select our GAX / Synthetic ROV Tether series.
Explore the marine, offshore and shipboard cable range for related configurations.
EOM RM-Series Torque-Balanced Steel-Armoured Main-Lift Construction
Every EOM main-lift umbilical combines void-free water-blocked electrical-optical core stranding with computer-balanced contra-helical high-tensile steel armour layers engineered to prevent birdcaging and torsional spin during deepwater AHC cycling.

| Component | Material and construction |
|---|---|
| 1. Medium-Voltage Power Conductors | Fine-stranded tinned annealed copper (IEC 60228 Class 5, 3.0 to 16.0 mm² / 12 to 6 AWG) insulated with thin-wall cross-linked polyolefin, EPR or polypropylene for 1.0 kV, 3.0 kV or 4.5 kV 3-phase vehicle and TMS motor supply. |
| 2. Control, Telemetry & Auxiliary Cores | Insulated tinned copper control singles, shielded twisted pairs or star quads (0.50 to 2.5 mm², 600/1000 V) with aluminium/PET or tinned copper braid screening for sonar, valve packs and TMS sensors. |
| 3. Hermetic Stainless-Steel Optical Element (FIMT) | One or two laser-welded 316L stainless-steel tubes (1.5 to 3.2 mm tube OD, thixotropic hydrogen-scavenging gel) over-sheathed in polyolefin, protecting 4 to 12 single-mode (G.652.D / G.657.A1) or multimode fibres to 60 MPa. |
| 4. Water-Blocked Interstices & Inner Sheath | Elastomeric water-blocking compound and synthetic fillers eliminating internal compression voids, enclosed by a tough seamless HDPE, thermoplastic polyester or polyurethane inner bedding jacket. |
| 5. Inner & Outer Contra-Helical Steel Wire Armour | Two (or three) opposing helical layers of preformed galvanized improved plow steel (GIPS, 1,770 to 2,160 MPa tensile grade) or Zn-5Al coated steel wires engineered for near-zero net torque across 10% to 50% MBL. |
| 6. Pressure-Injected Corrosion & Wear Matrix | Marine-grade anti-corrosive wire-rope lubricant pressure-injected across every armour interstice to cut inter-wire fretting over AHC sheaves (optional extruded HDPE or PUR outer jacket available for corrosive/abrasive winches). |

EOM & RM-Series Main-Lift Umbilical Code & Layer Breakdown
- EOM: Electro-Opto-Mechanical umbilical combining medium-voltage electrical power, optical fibre telemetry and load-bearing steel armour in one dynamic lift line
- RM0037 / RM0049 / RM0060 / RM0066 / RM0067: standardized ROV main-lift umbilical configurations spanning 17.3 mm (185 kN) light work-class to 41.2 mm (880 kN) ultra-heavy work-class builds
- FIMT (1x6SM / 2x4SM): Fiber-In-Metal-Tube: laser-welded 316L stainless-steel micro-tube filled with hydrogen-scavenging gel housing 4 to 12 single-mode optical fibres
- GIPS / Zn-5Al Contra-Helical SWA: two or three opposing helical layers of Galvanized Improved Plow Steel or zinc-5% aluminium coated high-tensile wire balanced for near-zero torque
EOM Work-Class ROV, AHC LARS Winch & Trenching Main-Lift Applications
Specify RM-Series and EOM torque-balanced steel-armoured umbilicals on offshore construction vessels, drillships and subsea intervention spreads operating heavy LARS winches.

- Deepwater work-class ROV + top-hat or side-entry Tether Management System (TMS) main-lift winches rated 1,500 to 4,000 m.
- Active Heave Compensation (AHC) traction and storage winch systems demanding torque-neutral steel armour over flag and overboarding sheaves.
- High-power subsea pipeline trenchers, cable-burial ploughs and salvage tool skids drawing 100 to 400 kVA over minimal umbilical diameter.
- Scheduled drum re-roping and emergency short-lead replacement of RM0037, RM0049, RM0060, RM0066, RM0067 and A304-class main-lift cables.
EOM Steel-Armoured Main-Lift vs Synthetic Lift vs Excursion Tether Boundary
| Umbilical Architecture | Strength Member | Seawater Weight & Depth Advantage | Primary ROV Role |
|---|---|---|---|
| RM-Series / EOM Steel-Armoured (this page) | 2- or 3-layer contra-helical GIPS / Zn-5Al steel wire | 815 to 5,193 kg/km | high crush resistance on multi-layer drums | 100 to 4,000 m work-class ROV + heavy TMS cage main lift |
| Synthetic-Armoured Lift Umbilical (ID 6024) | Contra-helical LCP / aramid yarn under PUR jacket | Near-neutral to light negative | eliminates steel self-weight | Ultra-deepwater (> 3,500 m) or weight-limited portable LARS winches |
| Neutrally Buoyant ROV Tether (ID 6016 / 6018) | Braided aramid fibre + foamed buoyancy TPR/PUR jacket | Zero / slightly positive buoyancy in seawater | 150 to 1,000 m horizontal excursion from TMS garage to free-flying ROV |
| RS726-DC FMBP Deck Jumper (UMB01) | Dual galvanized steel tape + flame-retardant PVC | Topside tray routing only (not for submerged winching) | Static deck interconnect between HPU van and winch slip-ring box |
In 500 to 3,500 m work-class ROV operations with heavy TMS cages, bare contra-helical steel wire armour remains the offshore workhorse because its radial stiffness resists multi-layer drum crushing and conducts heat rapidly into seawater.
EOM ROV Main-Lift Umbilical RFQ Engineering & Winch Specification Checklist
- Reference model (such as RM0049, RM0066, RM0037, RM0067, RM0060 or A304562) or custom core count + target outer diameter (mm).
- Operating water depth (m), ROV + TMS wet weight (kg), AHC dynamic load factor and required Minimum Breaking Load (kN).
- Power circuit voltage (for example 3,000 V or 4,160 V 3-phase), apparent power (kVA), acceptable voltage drop (%) and control pair/quad count.
- Optical fibre count (SM 9/125 µm or MM 50/125 µm) and whether redundant dual stainless-steel FIMT tubes are required.
- Existing LARS drum core diameter, Lebus groove pitch, traction/overboarding sheave root diameter and slip-ring/socket interface.
- Continuous length per reel (MOQ 50 m; lead time 7 to 45 working days) and export steel drum dimensional/weight limits.
Related selection resources
- Marine, offshore and subsea cable product catalog
- Custom subsea and ROV umbilical manufacturing capabilities
- RS726 & RS935 Companion ROV/Pontoon Umbilical & Topside FMBP Deck Cable
- Synthetic-Armoured ROV Tether & Seabed Trencher Umbilical Cable
- CTD Profiling, Sonar Array & Deep-Ocean Oceanographic Cable
- Selection guide: ROV main-lift umbilical vs excursion tether vs topside deck cable
- Engineering guide: LARS sheave pitch ratio and Lebus winch groove matching
EOM Steel-Armoured ROV Main-Lift Umbilical Frequently Asked Questions
What minimum breaking load do RM-Series and EOM steel-armoured ROV main-lift umbilicals provide?
185 kN to 880 kN across standard builds: EOM RM0049 (17.3 mm OD) provides 185 kN, EOM RM0037 (35.1 mm) provides 680 kN, EOM RM0066 (34.1 mm) provides 695 kN, and heavy work-class EOM RM0067 (39.7 mm) and EOM RM0060 (41.2 mm) each deliver 880 kN minimum breaking load.
Why do EOM ROV main-lift umbilicals use contra-helical steel wire armour instead of single-layer armour?
2 or 3 opposing helical layers cancel rotational torque under tension. A single armour layer acts like a torsion spring that twists the ROV/TMS during descent and forms destructive kinks (hockles) if tension drops on the seafloor; contra-helical EOM armour keeps rotation within ±2 degrees per meter.
How are optical fibres protected against 4,000 m hydrostatic pressure inside an EOM ROV umbilical?
Laser-welded 316L stainless-steel Fiber-In-Metal-Tube (FIMT) construction protects the fibres. Single-mode or multimode fibres are cushioned in hydrogen-absorbing thixotropic gel with 0.15% to 0.25% excess fibre length inside a seamless steel micro-tube before polymeric over-sheathing, isolating the glass from 40 to 60 MPa water pressure and axial stretch.
Can TEBAOFLEX custom-match an EOM main-lift umbilical outer diameter to an existing Lebus winch shell?
Yes. TEBAOFLEX engineers power conductor insulation wall, filler geometry and contra-helical armour wire gauges to hold nominal outer diameter within ±0.5 to ±0.8 mm of your existing Lebus groove pitch, starting from a 50 m minimum order quantity.
What are the minimum order quantity and delivery lead time for EOM steel-armoured ROV main-lift cables?
50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days depending on continuous drum length (up to 5,000 m+) and FIMT/armour specification.
EOM RM-Series & A304-Series Dimensional, Weight & Breaking-Load Schedule
EOM ROV Main-Lift Key Mechanical, Electrical & Optical Summary
- Breaking strength envelope: 185 kN (17.3 mm inspection/light work-class) up to 680–880 kN (35.1–45.5 mm heavy work-class and trenching main lift)
- Torque-balanced SWA: Contra-helical 2- or 3-layer galvanized improved plow steel (GIPS) or Zn-5Al wire armour holding rotation within ±2 deg/m
- Deepwater FIMT optics: 1 or 2 laser-welded 316L stainless-steel tubes (4 to 12 SM/MM fibres) qualified for 3,000 to 6,000 m hydrostatic pressure
- Low-loss HV power delivery: 1.0 to 4.5 kV thin-wall XLPE/EPR/PP insulated tinned copper power cores minimizing voltage drop across 3,000 to 5,000 m winches
- Custom winch replacement: Engineered to match existing traction winch sheave ratios and drum core diameters; MOQ 50 m, 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 1.0 kV to 4.5 kV AC 3-phase main power cores with 600 to 1000 V auxiliary and instrumentation circuits |
| Reference model range | RM0049 (17.3 mm), RM0066 (34.1 mm), RM0037 (35.1 mm), A304472 (36.3 mm), RM0067 (39.7 mm), RM0060 (41.2 mm), A304562 (45.5 mm) |
| Breaking strength envelope | 185 kN to 880 kN minimum breaking load (MBL) with torque-balanced 2-layer or 3-layer GIPS / Zn-5Al steel wire armour |
| Optical telemetry package | 4 to 12 single-mode or hybrid SM/MM optical fibres sealed in gel-filled 316L stainless-steel FIMT tubes (4,000 to 6,000 m depth) |
| Bend radius and commercial terms | 355 to 790 mm minimum bend radius depending on OD with MOQ 50 m and 7 to 45 working days manufacturing lead time |
| Operating temperature range | -20 °C to +60 °C dynamic seawater operation; -30 °C to +75 °C topside winch drum storage (verify top-layer solar/I²R derating) |
| Torsional stability | Opposing helical armour lay angles engineered to keep cable rotation within ±2 degrees per meter across working tension |
EOM RM-Series & A304-Series Work-Class ROV Main-Lift Umbilical Schedule
| Model & Core Layout | Nominal Outer Diameter (mm) | Power + Control + Fibre Count | Weight in Air (kg/km) | Weight in Seawater (kg/km) | Min. Bend Radius (mm) | Min. Breaking Load MBL (kN) | Next step |
|---|---|---|---|---|---|---|---|
| EOM RM0029 (5x4+1x0.22STQ+6SM) | 17.3 | 5x4 mm² + 1x0.22 mm² STQ + 6 SM FIMT | 1050 | 810 | 280 | 140 | Request this size |
| EOM RM0049 (3x5+2x0.5+1x6SM) | 17.3 | 3x5 mm² + 2x0.5 mm² + 6 SM FIMT | 1060 | 815 | 355 | 185 | Request this size |
| EOM RM0026 (3x4+2x2.5+5SM/1MM) | 19.1 | 3x4 mm² + 2x2.5 mm² + 5 SM / 1 MM FIMT | 1220 | 920 | 260 | 200 | Request this size |
| EOM RM0035 (6x6.5+4x1.2+6SM) | 28.5 | 6x6.5 mm² + 4x1.2 mm² + 6 SM FIMT | 2910 | 2260 | 400 | 480 | Request this size |
| EOM RM0045 (9x10AWG+13x18AWG+7SM) | 33.2 | 9x10 AWG + 13x18 AWG + 7 SM FIMT | 4100 | 3270 | 750 | 659 | Request this size |
| EOM RM0053 (3x8.4+2x1.34STP+6SM) | 34.1 | 3x8.4 mm² + 2x1.34 mm² STP + 6 SM FIMT | 4100 | 3150 | 750 | 695 | Request this size |
| EOM RM0066 (3x8.4+4x1.34+1x6SM) | 34.1 | 3x8.4 mm² + 4x1.34 mm² + 6 SM FIMT | 4100 | 3150 | 750 | 695 | Request this size |
| EOM RM0015 (11x4+8x1.5+1STQ+8FO) | 35.1 | 11x4 + 8x1.5 mm² + 0.6 STQ + 4SM/4MM (2 FIMT) | 4200 | 3200 | 480 | 680 | Request this size |
| EOM RM0037 (11x4+8x1.5+4x0.6+2x4SM) | 35.1 | 11x4 + 8x1.5 + 4x0.6 mm² + 8 SM (2 FIMT) | 4200 | 3200 | 480 | 680 | Request this size |
| EOM A304472 (13P+4S+6SM) | 36.3 | 13 Power + 4 Signal + 6 SM FIMT | 3750 | 2838 | 725 | 449 | Request this size |
| EOM A302467 (6P+3S+6SM) | 38.1 | 6 Power + 3 Signal + 6 SM FIMT | 1890 | 746 | 760 | 498 | Request this size |
| EOM RM0067 (9x8.4+5x2.5+1x6SM) | 39.7 | 9x8.4 mm² + 5x2.5 mm² + 6 SM FIMT | 5600 | 4350 | 790 | 880 | Request this size |
| EOM RM0042 (41x2+1x1.5STP+12SM) | 39.8 | 41x2 mm² + 1x1.5 mm² STP + 12 SM FIMT | 4960 | 3700 | 600 | 720 | Request this size |
| EOM RM0060 (12x5+5x3+2x1+4x0.6+1x6SM) | 41.2 | 12x5 + 5x3 + 2x1 + 4x0.6 mm² + 6 SM FIMT | 5700 | 4350 | 700 | 880 | Request this size |
| EOM A304562 (20P+4S+1Coax+7SM) | 45.5 | 20 Power + 4 Signal + 1 Coax + 7 SM FIMT | 6680 | 5193 | 910 | 845 | Request this size |
| EOM RM0005 (18x10+1x1.34STQ+12SM) | 58.0 | 18x10.0 mm² + 1x1.34 mm² STQ + 12 SM (3 FIMT) | 12650 | 9950 | 800 | 1975 | Request this size |
EOM Steel Armour Safe Working Load & LARS Sheave Integration Parameters
| Engineering Parameter | 2-Layer Contra-Helical SWA | 3-Layer Contra-Helical SWA | LARS Winch & Integration Rule |
|---|---|---|---|
| Typical Safe Working Load (SWL) | 20% to 25% of MBL (dynamic factor 4:1 to 5:1) | 22% to 28% of MBL with reduced wire bending stress | Sum submerged cable weight + ROV/TMS wet weight + AHC snatch load |
| Recommended Dynamic Sheave Diameter | 35 x to 40 x Cable OD (min. 20 x OD bend radius) | 30 x to 36 x Cable OD for compact LARS A-frames | Match sheave groove radius to 0.525–0.55 x nominal cable OD |
| Optical Fibre Excess Fiber Length (EFL) | 0.15% to 0.25% positive EFL inside gelled SS tube | 0.15% to 0.25% positive EFL inside gelled SS tube | Prevents tensile strain on G.652.D fibres up to copper yield load |
| Winch Drum Dead-Wraps Cooling | Derate current on > 3 uncooled drum layers | Derate current on > 3 uncooled drum layers | Maintain forced air/water drum cooling during topside deck testing |
Safe Working Load (SWL) in dynamic offshore sea states must account for total suspended seawater mass (for example, 3,000 m of EOM RM0060 adds 3 x 4,350 kg = 13,050 kg / ~128 kN static self-weight before TMS/ROV payload and vessel heave acceleration).
Do not energize full medium-voltage HPU current for extended periods while multiple layers remain coiled in air on an uncooled storage drum; submarine heat dissipation in seawater is 8 to 12 times higher than stagnant multi-layer drum wraps.
Minimum order quantity is 50 m (supporting both short test/termination qualification lengths and continuous 1,500 to 5,000 m production winch lengths), with a lead time of 7 to 45 working days.
ASCII part references: EOM RM0049; EOM RM0066; EOM RM0037; EOM RM0067; EOM RM0060; A304472; A302467; A304835; A304562; ROV main lift EOM umbilical.
Full 13-model RM main-lift & heavy trencher cross-reference coverage: RM0005 (58.0 mm, 1975 kN heavy trencher / deep-ocean research), RM0015 (35.1 mm, 680 kN), RM0026 (19.1 mm, 200 kN), RM0029 (17.3 mm, 140 kN), RM0035 (28.5 mm, 480 kN), RM0037 (35.1 mm, 680 kN), RM0042 (39.8 mm, 720 kN), RM0045 (33.2 mm, 659 kN), RM0049 (17.3 mm, 185 kN), RM0053 (34.1 mm, 695 kN), RM0060 (41.2 mm, 880 kN), RM0066 (34.1 mm, 695 kN) and RM0067 (39.7 mm, 880 kN).
EOM Subsea Main-Lift Umbilical Standards & Routine Factory Test References
| Standard or specification | Application |
|---|---|
| ISO 13628-5 (Subsea Umbilicals) | Mechanical load-sharing, torque-balance verification, hydrostatic pressure integrity and factory electrical/optical acceptance framework. |
| DNV-ST-E402 / Offshore LARS Practice | Design alignment for dynamic umbilical safety factors, minimum overboarding sheave ratios and mechanical socket termination interfaces (project witness testing available on request). |
| IEC 60228 & High-Voltage DC/AC Routine Tests | Class 5 tinned copper conductor resistance and high-voltage dielectric withstand verification across every insulated power and control circuit. |
| ITU-T G.652.D / G.657.A1 Optical Telemetry | 1310 nm and 1550 nm OTDR attenuation profiling before and after contra-helical steel wire armouring (typical attenuation <= 0.40 dB/km at 1310 nm, <= 0.25 dB/km at 1550 nm). |
Certifications and document support
TEBAOFLEX quality system, HV dielectric withstand and OTDR routine test reports
ISO 13628-5 — Design and operation of subsea production and ROV umbilicals
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-RT Work-Class ROV TMS Excursion Tether & Subsea Intervention Cable (RT0084–RT0173 & 45XM301 Series)
A related cable option for a different application or duty profile.
View productRS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable (3.3–4.5 kV)
A related cable option for a different application or duty profile.
View productTF-OWIND Offshore Wind Monopile, Jacket & Mooring Chain Cleaning & NDT Crawler Dynamic Umbilical Cable (690 V–3.3 kV)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.