RS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable (3.3–4.5 kV)

RS726 and RS935 electro-optical umbilical and companion FMBP deck cables combine 1.8/3.0 (3.3) kV or 2.4/4.2 (4.5) kV medium-voltage power cores, low-voltage auxiliary/quad control circuits and laser-welded stainless-steel tube single-mode optical fibres inside either contra-helical Zn-5Al steel wire armour (41.0 mm / 670 kN; 28.6 mm / 340 kN) or galvanized steel-tape flame-retardant PVC deck armour (35.0 mm / 25.4 mm OD).

Product information
SKU
TF-RS726-UMB-DECK
Brand
TEBAOFLEX
Product overview

RS726 and RS935 electro-optical umbilical and FMBP deck cables deliver medium-voltage 3-phase hydraulic power (1.8/3.0 kV Um 3.3 kV or 2.4/4.2 kV Um 4.5 kV), vehicle/cage auxiliary power, screened telemetry quads and 8 to 12 single-mode optical fibres between topside power distribution, launch-and-recovery winches, floating pontoons and 150 to 250 HP work-class ROV spreads.

Offshore pontoon installations and ROV handling spreads require two mechanically distinct cables built around one electrically identical inner core. In the RS726 system (Gs(12)+9x16mm²+5x4mm²+A2-0.35mm²), nine 16 mm² HPU/TMS power cores, five 4 mm² vehicle/cage cores, a central 4×0.35 mm² screened quad and a 12-fibre laser-welded stainless-steel FIMT element are laid inside an orange 31.0 mm thermoplastic polyester inner sheath. Adding two contra-helical Zn-5Al steel wire layers (36×2.6 mm + 46×2.4 mm) produces the 41.0 mm, 670 kN dynamic umbilical (FMV-RP2.6/2.4), while wrapping dual 0.2 mm galvanized steel tapes and a black flame-retardant PVC jacket produces the 35.0 mm topside deck jumper (RS726-DC FMBP) linking deck HPU transformers to winch slip-ring junction boxes.

Specify RS726 or RS935 whenever replacing a damaged pontoon umbilical, commissioning a topside deck jumper or ordering a 50 to 1,000 m spare drum that must match existing Lebus drum grooves, A-frame sheaves and stuffing-tube glands without re-machining hardware. For bare deepwater main-lift cables up to 880 kN see our RM-Series EOM ROV Main-Lift Umbilicals, or for hose-integrated reels select our OMB Subsea Electro-Hydraulic Umbilicals.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

RS726 & RS935 Companion Umbilical (FMV-RP) & Deck Cable (FMBP) Construction

The RS726 family shares a precision 31.0 mm orange thermoplastic polyester inner electro-optical core (with 16 kV DC / 5 min factory routine test on all 1.8/3.0 kV power cores) finished with either dual contra-helical Zn-5Al steel wire armour for dynamic submerged lifting or dual galvanized steel tape plus flame-retardant PVC outer sheathing for topside deck routing.

Clean 2D engineering cross-section of RS726 41.0 mm electro-optical umbilical cable showing central 4x0.35 mm² screened quad, inner ring of five 4 mm² cores and one 12-fibre stainless-steel FIMT tube, outer ring of nine 16 mm² power cores, orange polyester inner sheath and two contra-helical steel wire armour layers
RS726 41.0 mm cross-section: central 4x0.35 mm² quad, 1st layer 5x4 mm² + Gs(12) FIMT, 2nd layer 9x16 mm² MV power cores, orange inner sheath and 36+46 steel armour wires.
RS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable (3.3–4.5 kV) construction
ComponentMaterial and construction
1. Central Screened Quad (UNIT-SQ)Four 0.35 mm² stranded copper conductors (7x0.25 mm, PP insulated to 1.4 mm: Blue/Red and White/Green pairs), jelly-filled with PET tape, 8x0.2 mm drain wires, Al/PET screen and natural PP sheath (4.6 mm OD; loop resistance <= 118 Ω/km).
2. First Layer — 5x4 mm² Auxiliary Power + Gs(12) FIMTFive 4 mm² power cores (7x0.88 mm Cu, semiconducting PP + colour-coded insulating PP to 4.0 mm, rated 1.8/3.0 kV Um 3.3 kV) laid right-hand with one Gs(12) 2.3 mm laser-welded stainless-steel tube housing 12 single-mode 9/125 µm fibres sheathed to 4.0 mm, 6x0.5 mm² screen wires and natural PP sheath (13.9 mm OD).
3. Second Layer — 9x16 mm² Main HPU & TMS PowerNine 16 mm² stranded copper conductors (7x1.78 mm, 4.8 mm conductor OD, semiconducting PP + colour-coded PP insulation to 6.5 mm for Forward HPU, Aft HPU and Cage TMS 3-phase groups) laid right-hand with 9x1.0 mm² screen wires and screen tape to 27.1 mm.
4. Shared Inner Sheath (31.0 mm Nominal OD)Extruded high-strength orange thermoplastic polyester elastomer inner sheath sealing the electrical-optical core bundle against radial crush and moisture ingress.
5A. Umbilical Armour Package (FMV-RP2.6/2.4 — 41.0 mm OD)PUR bedding tape, 1st armour layer of 36 x 2.6 mm Zn-5Al alloy-coated steel wires (right lay, 36.2 mm), corrosion-blocking lubricant, PUR separator tape and 2nd armour layer of 46 x 2.4 mm Zn-5Al steel wires (left lay, 41.0 ± 0.5 mm OD).
5B. Companion Deck Package (FMBP — 35.0 mm OD)Dual 0.2 mm galvanized steel tapes (< 20% gap, 32.0 mm OD) covered by a 1.5 mm black flame-retardant, oil- and UV-resistant PVC outer sheath (35.0 ± 1.0 mm OD) for fixed topside tray and pontoon deck runs.
Factory workshop macro sample photograph of TEBAOFLEX double contra-helical galvanized steel wire armoured subsea composite umbilical cable cut end showing two dense steel armour rings, black polymeric inner bedding, outer ring of heavy insulated copper power cores and central multi-core control and optical bundle
TEBAOFLEX workshop production sample: precision double contra-helical steel wire armour over multi-core power and central control/optical subsea core.

RS726 / FMV-RP / FMBP Designation & Core Code Breakdown

  • Gs(12) / 2xGs(4): gel-filled laser-welded stainless-steel tube optical element containing 12 single-mode fibres (RS726) or two tubes of 4 single-mode fibres (RS935)
  • 9x16mm² + 5x4mm²: nine 16 mm² 3-phase main HPU/TMS power conductors plus five 4 mm² vehicle/cage auxiliary power conductors (rated 1.8/3.0 kV, Um 3.3 kV)
  • A2-0.35mm² (4x0.34): central screened telecommunications quad comprising two pairs (4 x 0.35 mm² / ~22 AWG) with drain wires and Al/PET foil shield
  • FMV-RP2.6/2.4: subsea dynamic umbilical finish with thermoplastic polyester inner sheath and contra-helical 2.6 mm inner / 2.4 mm outer Zn-5Al steel wire armour
  • FMBP: companion topside deck cable finish applying dual 0.2 mm galvanized steel tapes and black flame-retardant PVC outer sheath over the identical inner core
Applications

RS726 & RS935 Pontoon, Work-Class ROV Winch & Topside Deck Applications

Deploy RS726 and RS935 electro-optical umbilicals and companion FMBP deck cables across offshore support vessels, floating pontoons, barge-mounted work-class ROV spreads and topside winch-to-transformer interconnections.

Heavy-duty steel-wire-armoured electro-optical umbilical cable paying out from an offshore pontoon and vessel LARS traction winch Drum alongside a topside black PVC deck jumper cable connected to a slip-ring junction box
Offshore pontoon and work-class ROV LARS winch routing armoured FMV-RP umbilical overboard with companion FMBP deck cable feeding the slip-ring box.
  • Floating pontoon, linkspan barge and nearshore marine construction projects requiring exact-OD spare electro-optical umbilical cables in 100 to 600 m cut lengths.
  • 150 to 250 HP work-class ROV and Tether Management System (TMS) main deployment winches supplying dual 3-phase HPU motors plus cage power at 3.0 to 4.5 kV.
  • Topside FMBP armoured deck jumper cables connecting HV transformer containers and HPU control vans to LARS winch slip-ring junction boxes with identical core colour coding.
  • Drop-in 1:1 outer-diameter replacement of aged RS726, RS379 and RS935 cables without changing Lebus drum shells, overboarding sheaves or mechanical socket terminations.

RS726 FMV-RP Umbilical vs FMBP Deck Cable vs Synthetic Tether Boundary

RS726 / RS935 FMV-RP Umbilical vs FMBP Companion Deck Cable vs Synthetic ROV Tether Selection Boundary
Cable TypeOuter ProtectionOuter Diameter & WeightWhere to Specify
RS726 FMV-RP2.6/2.4 Umbilical (this page)2-layer contra-helical Zn-5Al steel wire armour41.0 mm OD | 5,800 kg/km airSubmerged ROV main lift, floating pontoon catenary & LARS winch drum
RS726-DC FMBP Deck Cable (this page)2x0.2 mm galv. steel tape + black FR-PVC sheath35.0 mm OD | 2,800 kg/km airTopside deck tray jumper from HPU/transformer van to winch slip-ring box
RS935 FMV-RP (2- or 3-Layer SWA, this page)2- or 3-layer Zn-5Al steel wire armour (4.5 kV)28.6 mm OD | 2,600 kg/km airCompact 4.5 kV work-class ROV winches requiring smaller 850 mm bend diameter
Synthetic Aramid/LCP ROV Tether (ID 6024)Braided synthetic strength member + PUR jacket18 to 38 mm OD | neutrally or lightly negative in waterTMS cage-to-ROV horizontal excursion tether where steel weight is prohibitive

Never spool PVC-sheathed FMBP deck cable onto dynamic overboarding sheaves, and avoid running bare greased FMV-RP steel wire armour across enclosed topside accommodation cable trays where flame-retardant PVC jacketing is required.

RS726 & RS935 Spare Umbilical & Deck Cable RFQ Ordering Checklist

  • Cable duty & model code: submerged armoured umbilical (RS726 FMV-RP2.6/2.4 or RS935 FMV-RP), topside deck jumper (FMBP), or matched umbilical + deck pair.
  • Target outer diameter & tolerance (for example 41.0 ± 0.5 mm or custom groove-matched OD) plus existing Lebus winch groove pitch and minimum sheave root diameter.
  • Electrical core count, conductor cross-sections (such as 9x16 + 5x4 + 4x0.35 mm²) and rated phase-to-earth / phase-to-phase voltage (1.8/3.0 kV, 2.4/4.2 kV or custom).
  • Optical fibre count, mode (ITU-T G.652.D SM or OM2/OM3 MM) and stainless-steel FIMT tube count (1x12SM, 2x4SM or redundant dual tubes).
  • Required minimum breaking load (kN), safe working load at copper yield (kN) and maximum operating water depth.
  • Continuous drum cut length (MOQ 50 m; lead time 7 to 45 working days), shipping reel flange limits and factory test / third-party witness requirements.

Related selection resources

RS726 & RS935 Umbilical and Deck Cable Frequently Asked Questions

Can TEBAOFLEX manufacture a 300 m spare RS726 umbilical cable matching the exact 41.0 mm outer diameter?

Yes. TEBAOFLEX manufactures custom and replacement RS726-class electro-optical umbilicals (Gs(12)+9x16+5x4+A2-0.35 / 9x16+5x4+4x0.34+12FO) from a 50 m minimum order quantity with outer diameter controlled to 41.0 ± 0.5 mm so 100 to 500 m pontoon or ROV spare lengths fit existing Lebus winch grooves, sheaves and mechanical terminations without hardware modification.

What is the difference between RS726 FMV-RP2.6/2.4 umbilical cable and RS726-DC FMBP deck cable?

6.0 mm in outer diameter and 670 kN vs 1 kN tensile rating. Both cables share the identical 31.0 mm orange polyester electro-optical core (9x16 + 5x4 + 4x0.35 mm² + 12SM), but FMV-RP2.6/2.4 adds two contra-helical Zn-5Al steel wire armour layers (41.0 mm OD, 5.8 kg/m, 670 kN breaking strength) for dynamic subsea lifting, whereas FMBP applies dual 0.2 mm galvanized steel tapes and a black flame-retardant PVC jacket (35.0 mm OD, 2.8 kg/m) for static topside deck routing.

Is 9x16+5x4+4x0.34+12FO the same core configuration as Gs(12)+9x16mm²+5x4mm²+A2-0.35mm² in RS726?

Yes. In RS726 engineering documentation, A2-0.35mm² denotes one screened star-quad of four 0.35 mm² (7x0.25 mm, ~22 AWG / 0.34 mm² nominal) signal conductors and Gs(12) denotes 12 single-mode optical fibres inside a gel-filled laser-welded stainless-steel tube, combined with nine 16 mm² and five 4 mm² 1.8/3.0 (3.3) kV power conductors.

When should 3-layer armoured RS935 (FMV-RP1.0/1.2/1.4) be chosen over 2-layer RS935 (FMV-RP2.0/1.6)?

28.6 mm OD and 340 kN breaking strength are identical on both RS935 options, but the 3-layer armour build (65x1.0 + 59x1.2 + 56x1.4 mm wires) uses finer wire diameters to achieve superior torque balance under high-cycle active heave compensation (AHC) flexing, whereas 2-layer 34x2.0 + 48x1.6 mm provides thicker outer wires against external seabed and pontoon chafe.

What are the minimum order quantity and production lead time for RS726 and RS935 umbilical and deck cables?

50 m minimum order quantity (MOQ), with a factory manufacturing lead time of 7 to 45 working days depending on stainless-steel FIMT fibre count and Zn-5Al armour wire stranding schedule.

Specifications

RS726 & RS935 Dimensional, Electrical, Optical & Tensile Specifications

RS726 & RS935 Key Mechanical, Voltage & Replacement Summary

  • Companion twin-build system: Shared 31.0 mm (RS726) or 21.4 mm (RS935) inner core finished as FMV-RP steel-wire umbilical or FMBP topside deck cable
  • Exact 1:1 spare OD matching: 41.0 ± 0.5 mm (RS726), 35.0 ± 1.0 mm (RS726-DC) and 28.6 ± 1.0 mm (RS935) to fit existing Lebus winch grooves and sheaves
  • Composite core architecture: 9x16 + 5x4 + 4x0.35 mm² + Gs(12) 12SM FIMT on RS726; 6x8 + 4x1 mm² + 2xGs(4) 8SM FIMT on RS935
  • Mechanical lift ratings: 670 kN breaking / 190 kN yield load on RS726 (600 mm dynamic bend radius); 340 kN breaking / 100 kN yield on RS935
  • Short-run replacement supply: Minimum order quantity 50 m (including 100 to 500 m pontoon and deck spares) manufactured in 7 to 45 working days
RS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable (3.3–4.5 kV) technical data
ParameterValue
Rated voltage1.8/3.0 kV (Um 3.3 kV) on RS726 power cores and 2.4/4.2 kV (Um 4.5 kV) on RS935 power cores
Composite core architecture9x16 + 5x4 + 4x0.35 mm² + 12SM FIMT (RS726) or 6x8 + 4x1 mm² + 2x4SM FIMT (RS935)
Armour and jacket optionsContra-helical Zn-5Al steel wire armour (FMV-RP) for subsea lift or galvanized steel tape + PVC (FMBP) for deck
Outer diameter and tensile rating41.0 mm OD / 670 kN breaking load (RS726 umbilical), 35.0 mm OD (RS726 deck), 28.6 mm OD / 340 kN (RS935)
Dynamic bend radius and supply600 mm (RS726), 350 mm (RS726-DC), 425 mm (RS935) minimum bend radius with MOQ 50 m in 7 to 45 working days
Optical fibre performanceITU-T G.652.D 9/125 µm single-mode fibres in gel-filled laser-welded stainless-steel tube (<= 0.6 dB/km at 1310 nm, <= 0.4 dB/km at 1550 nm)
Routine factory dielectric tests16 kV DC / 5 min on 16 mm² and 4 mm² MV cores; 2.5 kV DC / 10 s on 0.35 mm² quad; insulation resistance > 5 GΩ·km

RS726 & RS935 Umbilical and Companion FMBP Deck Cable Schedule

RS726 & RS935 Electro-Optical Umbilical (FMV-RP) and Companion Deck Cable (FMBP) — Dimensional & Mechanical Schedule
Model & Core ConfigurationNominal Outer Diameter (mm)Power Voltage Rating (kV)Armour / Outer ProtectionWeight Air | Seawater (kg/km)Min. Dynamic Bend Radius (mm)Breaking | Yield Load (kN)Next step
RS726 FMV-RP2.6/2.4 (Gs(12)+9x16+5x4+A2-0.35)41.0 ± 0.51.8/3.0 (3.3)36x2.6 + 46x2.4 mm Zn-5Al SWA5800 | 4400600670 | 190Request this size
RS726-DC FMBP Deck (Gs(12)+9x16+5x4+A2-0.35)35.0 ± 1.01.8/3.0 (3.3)2x0.2 mm Galv. Steel Tape + FR-PVC2800 | N/A (Deck)350N/A | 1.0 SWLRequest this size
FMV-RP2.0/1.6 RS935 (2xGs(4)+6x8+4x1)28.6 ± 1.02.4/4.2 (4.5)34x2.0 + 48x1.6 mm Zn-5Al SWA2600 | 2000425340 | 100Request this size
FMV-RP1.0/1.2/1.4 RS935-3A (2xGs(4)+6x8+4x1)28.6 ± 1.02.4/4.2 (4.5)65x1.0 + 59x1.2 + 56x1.4 mm 3-Layer SWA2600 | 2000425340 | 100Request this size
FMV-DC RS935 FMBP Deck (2xGs(4)+6x8+4x1)25.4 ± 1.02.4/4.2 (4.5)2x0.2 mm Galv. Steel Tape + FR-PVC1350 | N/A (Deck)260N/A | 1.0 SWLRequest this size

RS726 Sub-Element Electrical, Dielectric & Optical Test Data

RS726 Shared 31.0 mm Electro-Optical Inner Core — Sub-Component Electrical, Dielectric & Optical Verification
Internal Element CodeCount & Cross-SectionStranding & Core OD (mm)Circuit Allocation & Colour CodeMax. DC Resistance at 20 °C (Ω/km)Routine HV Test & Optical Limit
UNIT-P16 (2nd Layer)9 x 16 mm²7x1.78 Cu | 6.5 mm PPFwd HPU (Bu/Rd/Aq), Aft HPU (Wh/Gy/Pk), TMS (Gn/Ye/Og)1.2716 kV DC / 5 min; IR > 5 GΩ·km
UNIT-P4 (1st Layer)5 x 4 mm²7x0.88 Cu | 4.0 mm PPCage 1 (Bu), Veh 1 (Wh), Spare (Gn), Cage 2 (Rd), Veh 2 (Og)5.2016 kV DC / 5 min; IR > 5 GΩ·km
UNIT-SQ (Centre Quad)4 x 0.35 mm² (2 Pairs)7x0.25 Cu | 4.6 mm SheathPair 1 (Blue/Red), Pair 2 (White/Green) + Al/PET screen118.0 (loop)2.5 kV DC / 10 s; IR > 5 GΩ·km
UNIT-FO Gs(12) FIMT12 x SM 9/125 µm2.3 mm SS Tube | 4.0 mm PP12 colour-coded SM fibres (#1-#6 25 mm ring, #7-#12 50 mm)N/A (Optical)<= 0.6 dB/km (1310 nm) | <= 0.4 dB/km (1550 nm)

Minimum dynamic bending diameter is 1,200 mm (600 mm bend radius, approximately 14.6 x OD) for RS726 FMV-RP2.6/2.4 under tension over A-frame and traction sheaves, and 700 mm (350 mm bend radius) for the companion RS726-DC FMBP topside deck cable.

In customer BOMs where the central screened quad is rounded by wire gauge conversion, Gs(12)+9x16mm²+5x4mm²+A2-0.35mm² is frequently written as 9x16+5x4+4x0.34+12FO — both designations share the exact 31.0 mm inner core and 41.0 mm armoured outer diameter.

Minimum order quantity is 50 m with a production lead time of 7 to 45 working days on export steel or reinforced wooden drums, enabling economical 150 to 500 m pontoon and deck spares without 2,000 m mill minimums.

ASCII part references: RS726; RS726-TD-02E; RS726-DC; RS379-TD-10E; RS935; FMV-RP2.6/2.4; FMV-RP2.0/1.6; FMV-RP1.0/1.2/1.4; FMBP; Gs(12)+9x16+5x4+A2-0.35; 9x16+5x4+4x0.34+12FO.

Standards

RS726 & RS935 Subsea Umbilical Standards & Routine Factory Test References

RS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable (3.3–4.5 kV) standards and test references
Standard or specificationApplication
ISO 13628-5 / API Spec 17EDesign, contra-helical armour load-sharing, torque-balance and verification architecture for subsea electro-optical control and ROV umbilicals.
IEC 60228 & Semiconducting PP MV Core DesignStranded copper conductors with extruded semiconducting stress-control and polypropylene insulation tested at 16 kV DC for 5 minutes.
ITU-T G.652.D & Laser-Welded FIMTSingle-mode 9/125 µm optical fibres housed in gel-filled 316L stainless-steel tubing (0.2 mm wall) resisting hydrostatic crush and hydrogen ingress.
IEC 60332-1-2 (FMBP Deck Sheath)Flame-retardant black PVC outer jacket over dual galvanized steel tapes for topside deck cable runs between HPU containers and winch slip rings.

Certifications and document support

TEBAOFLEX ISO quality management, 16 kV DC dielectric and OTDR optical test documentation

ISO 13628-5 — Petroleum and natural gas industries: Subsea umbilicals design and testing reference

ITU-T G.652 — Characteristics of single-mode optical fibre and cable for FIMT subsea telemetry

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.