MINING & TUNNELING CABLES TEBAOFLEX

NTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable

NTSCGEWÖU-TR (NTSCGEWOEU-TR) is a medium-voltage open-pit trailing cable built with reference to DIN VDE 0250-813 across six voltage classes from 3.6/6 kV up to 18/30 kV (3×25+3×25/3 to 3×185+3×95/3 mm²), featuring an embedded tear-resistant reinforcing grid tape between heavy-duty black 5GM5 rubber sheaths for ±100 °/m torsion and -35 °C flexible (-50 °C fixed) bench dragging.

Product information
SKU
TF-NTSCGEWOEU-TR
Brand
TEBAOFLEX
Product overview

NTSCGEWÖU-TR / NTSCGEWOEU-TR open-pit trailing cable supplies 3.6/6 kV through 18/30 kV power (Umax up to 20.8/36 kV AC) to electric rope shovels, walking draglines, hydraulic face excavators and mobile pit crushers, combining class 5 tinned-copper 3GI3 EPR phases, three semiconductive-elastomer split earth cores, a tear-resistant reinforcing grid tape and a black 5GM5 rubber sheath.

When a 70 to 100 mm medium-voltage cable is dragged across blasted granite, iron-ore or overburden benches by cable-handler tractors or slewing shovel booms, sharp rock edges initiate surface nicks that propagate rapidly under ±100 °/m torsional twist and 8 kN drawbar pull. Unlike unreinforced trailing builds where a rock gash can peel open the outer jacket, NTSCGEWÖU-TR bonds a high-tenacity reinforcing grid tape between the inner and outer 5GM5 elastomer layers. The open-mesh grid locks both rubber sheaths into one composite wall, arresting longitudinal tear propagation and preventing core corkscrewing without sacrificing cold-weather flexibility down to -35 °C dynamic (-50 °C fixed).

Specify NTSCGEWÖU-TR whenever medium-voltage cables are dragged directly on rough pit floors or hauled on slewing excavators. For motorised bucket-wheel excavator or crane drums use R-(N)TSCGEWÖU reeling cable, for North American metallic-shielded couplers use SHD-GC, and for underground monorail festoons use (N)TSKCGECWÖU-FN.

Explore the mining and tunneling cable range for related configurations.

Construction

NTSCGEWÖU-TR Grid-Reinforced Trailing Cable Construction

NTSCGEWÖU-TR is manufactured on catenary continuous vulcanization (CCV) triple-extrusion and heavy-sheath lines with reference to DIN VDE 0250-813.

Clean 2D engineering cross-section of NTSCGEWÖU-TR cable showing three tinned-copper phase cores with inner semiconductive, thick EPR and outer semiconductive layers, three semiconductive-covered earth cores in the interstices, inner 5GM5 sheath, reinforcing grid ring and black outer 5GM5 sheath
NTSCGEWÖU-TR cross-section: 3 semiconductive-screened EPR phases + 3 split earths inside a grid-reinforced double 5GM5 sheath.
NTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable construction
ComponentMaterial and construction
1. Phase conductorsFinely stranded tinned copper wires, class 5 to IEC 60228 (25 to 185 mm²).
2. MV stress control & insulationCo-extruded inner semiconductive layer, EPR compound type 3GI3 to DIN VDE 0207-20, and outer semiconductive insulation shield.
3. Split protective earthThree class 5 tinned copper earth conductors enclosed in semiconductive rubber, laid symmetrically in the three outer interstices.
4. Inner sheathHeavy-duty rubber compound type 5GM5 to DIN VDE 0207-21.
5. Anti-tear grid reinforcementHigh-strength tear-resistant reinforcing grid tape locking the inner and outer sheaths against transverse cuts and axial sheath creep.
6. Outer sheathAbrasion- and tear-enhanced black 5GM5 rubber sheath to DIN VDE 0207-21 (LOI above 29), oil, UV and ozone resistant, inkjet marked.

NTSCGEWÖU-TR Designation Breakdown

  • NT: Flexible medium-voltage rubber trailing cable built with reference to DIN VDE 0250-813
  • SC: Semiconductive elastomer field-control screens over the phase insulation and split earth cores
  • GE: 3GI3 ethylene-propylene rubber (EPR) medium-voltage core insulation
  • WÖU: Weather, oil (Ö) and flame-retardant (U) heavy-duty 5GM5 rubber sheath
  • -TR: Tear-resistant open-pit design with reinforcing grid tape embedded between inner and outer sheaths
Applications

NTSCGEWÖU-TR Open-Pit Shovel and Dragline Applications

NTSCGEWÖU-TR is built for extreme mechanical dragging, rock abrasion and sub-zero ambient conditions in surface mines.

Open-pit mine rocky bench with a heavy black NTSCGEWÖU-TR medium-voltage trailing cable routed across blasted rock behind an electric mining shovel
Typical duty: bench-dragged MV trailing feeder behind an open-pit electric rope shovel.
  • Bench-trailing feeder cables for electric rope shovels, walking draglines and heavy hydraulic mining excavators (3.6/6 to 18/30 kV).
  • Open-pit copper, iron-ore, gold, coal and lignite mines using skid substations and tire-mounted cable-handling equipment.
  • Mobile in-pit crushing and conveying (IPCC) hoppers, blast-hole drills and overburden spreaders.
  • Cold-climate surface mines requiring -35 °C flexible trailing and -50 °C fixed cold withstand.

NTSCGEWÖU-TR vs Reeling, Conveyor and SHD-GC Cables

NTSCGEWÖU-TR vs R-(N)TSCGEWÖU vs F-(N)TSCGEWÖU vs SHD-GC
Cable familyMechanical dutyReinforcement & earth screenVoltage span
NTSCGEWÖU-TR (this page)Open-pit shovel & dragline bench trailing (±100 °/m)Anti-tear grid tape + 3 semiconductive split earths3.6/6 to 18/30 kV
R-(N)TSCGEWÖUMotorised reeling drums on BWEs & stackersAnti-torsion textile braid between sheaths3.6/6 to 18/30 kV
F-(N)TSCGEWÖUShiftable pit conveyors & semi-fixed feedersStandard trailing sheath without grid reinforcement3.6/6 to 18/30 kV
Type SHD-GC (ICEA)North American coupler-connected shovel trailingMetallic copper braid/tape phase shields + ground-check2 kV to 25 kV

ASCII search equivalents: NTSCGEWOEU-TR 6/10 kV 3x70+3x35/3; (N)TSCGEWOEU-TR 8.7/15 kV; NTSCGEWOU-TR 12/20 kV; NTSCGEWOEU-TR 18/30 kV shovel cable.

NTSCGEWÖU-TR Open-Pit Trailing Cable RFQ Checklist

  • Rated voltage class (3.6/6, 6/10, 8.7/15, 12/20, 14/25 or 18/30 kV) and system maximum voltage.
  • Phase and split-earth cross-section (3x25+3x25/3 up to 3x185+3x95/3 mm², including 3x50+3x50/3 or 3x150+3x50/3 options).
  • Equipment type (rope shovel, dragline, hydraulic excavator, drill) and coupler gland entry diameter range.
  • Minimum winter bench ambient temperature, altitude and continuous pit-piece length per reel.
  • Total order quantity and delivery target (MOQ 50 m; manufacturing lead time 7 to 45 working days).

Related selection resources

NTSCGEWÖU-TR Trailing Cable FAQ

What does the -TR suffix add to NTSCGEWÖU-TR?

1 embedded high-strength tear-resistant reinforcing grid tape between the inner and outer 5GM5 rubber sheaths, stopping rock cuts from tearing open the jacket and rated for ±100 °/m torsion.

Which voltage ratings are covered by NTSCGEWÖU-TR?

6 medium-voltage ratings: 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 14/25 kV and 18/30 kV (with 50 Hz factory AC test voltages of 11, 17, 24, 29, 36 and 43 kV).

How cold can NTSCGEWÖU-TR operate in open-pit mines?

-35 °C to +80 °C during flexible trailing movement and -50 °C to +90 °C in fixed installation, with a 90 °C continuous conductor rating.

Does NTSCGEWÖU-TR use metallic phase screens or semiconductive elastomer screens?

3 semiconductive elastomer phase insulation shields in radial contact with 3 semiconductive-covered tinned-copper earth cores in the interstices, per DIN VDE 0250-813.

What are the MOQ and lead time for NTSCGEWÖU-TR?

50 m minimum order quantity across all 6 voltage classes, with a factory lead time of 7 to 45 working days.

Specifications

NTSCGEWÖU-TR 3.6/6–18/30 kV Technical Data and Size Schedule

NTSCGEWÖU-TR Key Voltage, Torsion and Sub-Zero Ratings

  • 6 MV voltage classes: Full schedule covering 3.6/6, 6/10, 8.7/15, 12/20, 14/25 and 18/30 kV (AC test 11 to 43 kV)
  • Tear-resistant grid (-TR): Reinforcing grid tape embedded between the inner and outer 5GM5 sheaths stops transverse cuts and sheath slip
  • ±100 °/m torsional rating: Withstands ±100 °/m twist plus 15 N/mm² phase pull when dragged behind slewing electric rope shovels and draglines
  • Sub-zero bench service: -35 °C to +80 °C flexible operation and -50 °C to +90 °C fixed installation with UV, ozone and oil resistance
  • Custom pit lengths: 3x25 to 3x185 mm² across all 6 voltage levels manufactured from MOQ 50 m in 7 to 45 working days
NTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable technical data
ParameterValue
Rated voltage3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 14/25 kV and 18/30 kV U0/U
Conductor range3x25+3x25/3 mm² to 3x185+3x95/3 mm² class 5 tinned copper
Reinforcement and sheathTear-resistant reinforcing grid tape between black 5GM5 inner and outer rubber sheaths
Torsion and tensionUp to 100 deg/m bidirectional torsion and 15 N/mm² phase tensile load (1,125 to 8,325 N)
Temperature envelope-35 °C to +80 °C flexible trailing, -50 °C to +90 °C fixed, 90 °C conductor (250 °C short-circuit)
AC test voltages11 kV (3.6/6), 17 kV (6/10), 24 kV (8.7/15), 29 kV (12/20), 36 kV (14/25), 43 kV (18/30 kV)
Supply termsMOQ 50 m; manufacturing lead time 7 to 45 working days

NTSCGEWÖU-TR 3.6/6 kV to 18/30 kV Multi-Voltage Schedule

NTSCGEWÖU-TR 3.6/6 kV to 18/30 kV open-pit trailing cable — representative size schedule across all 6 voltage classes (intermediate sizes 3x35, 3x50, 3x70, 3x95, 3x120, 3x150 and 3x185 mm² available in every voltage class)
Model, voltage and sizeRated U0/UOuter diameter min–max (mm)Max. DC resistance at 20 °C (Ω/km)Current at 30 °C (A)Approx. weight (kg/km)Max. tensile load (N)Next step
NTSCGEWOEU-TR 3.6/6 kV 3x25+3x25/33.6/6 kV44–470.7951312,8551,125Request this size
NTSCGEWOEU-TR 3.6/6 kV 3x50+3x25/33.6/6 kV51–540.3932023,9632,250Request this size
NTSCGEWOEU-TR 3.6/6 kV 3x95+3x50/33.6/6 kV60–630.2103016,2144,275Request this size
NTSCGEWOEU-TR 3.6/6 kV 3x150+3x70/33.6/6 kV68–710.1324048,4846,750Request this size
NTSCGEWOEU-TR 6/10 kV 3x35+3x25/36/10 kV49–520.5651623,5031,575Request this size
NTSCGEWOEU-TR 6/10 kV 3x70+3x35/36/10 kV58–610.2772505,3703,150Request this size
NTSCGEWOEU-TR 6/10 kV 3x120+3x70/36/10 kV65–680.1643527,5925,400Request this size
NTSCGEWOEU-TR 6/10 kV 3x185+3x95/36/10 kV76–790.10846110,6218,325Request this size
NTSCGEWOEU-TR 8.7/15 kV 3x35+3x25/38.7/15 kV54–570.5651724,1131,575Request this size
NTSCGEWOEU-TR 8.7/15 kV 3x70+3x35/38.7/15 kV63–660.2772656,0863,150Request this size
NTSCGEWOEU-TR 8.7/15 kV 3x120+3x70/38.7/15 kV71–740.1643718,4265,400Request this size
NTSCGEWOEU-TR 8.7/15 kV 3x185+3x95/38.7/15 kV82–850.10848811,5918,325Request this size
NTSCGEWOEU-TR 12/20 kV 3x35+3x25/312/20 kV60–630.5651724,7621,575Request this size
NTSCGEWOEU-TR 12/20 kV 3x70+3x35/312/20 kV69–720.2772656,8363,150Request this size
NTSCGEWOEU-TR 12/20 kV 3x120+3x70/312/20 kV76–790.1643719,2265,400Request this size
NTSCGEWOEU-TR 12/20 kV 3x185+3x95/312/20 kV87–900.10848812,4738,325Request this size
NTSCGEWOEU-TR 14/25 kV 3x50+3x25/314/25 kV71–740.3932156,5532,250Request this size
NTSCGEWOEU-TR 14/25 kV 3x95+3x50/314/25 kV80–830.2103199,2044,275Request this size
NTSCGEWOEU-TR 14/25 kV 3x150+3x70/314/25 kV88–910.13242811,8026,750Request this size
NTSCGEWOEU-TR 18/30 kV 3x35+3x25/318/30 kV72–750.5651726,5331,575Request this size
NTSCGEWOEU-TR 18/30 kV 3x70+3x35/318/30 kV81–840.2772658,8473,150Request this size
NTSCGEWOEU-TR 18/30 kV 3x120+3x70/318/30 kV89–920.16437111,4315,400Request this size
NTSCGEWOEU-TR 18/30 kV 3x185+3x95/318/30 kV100–1030.10848815,0148,325Request this size

All eight phase cross-sections (25, 35, 50, 70, 95, 120, 150 and 185 mm², plus 3x50+3x50/3, 3x150+3x50/3 and 3x185+3x50/3 in 6/10 kV) are manufactured across every voltage class from 3.6/6 kV to 18/30 kV.

1-second phase short-circuit current ratings are 3.20 kA (25 mm²), 4.48 kA (35 mm²), 6.40 kA (50 mm²), 8.96 kA (70 mm²), 12.16 kA (95 mm²), 15.36 kA (120 mm²), 19.20 kA (150 mm²) and 23.68 kA (185 mm²).

ASCII part references: NTSCGEWOEU-TR 3.6/6 kV 3x50+3x25/3; NTSCGEWOEU-TR 6/10 kV 3x70+3x35/3; NTSCGEWOEU-TR 8.7/15 kV 3x120+3x70/3; NTSCGEWOEU-TR 12/20 kV; NTSCGEWOEU-TR 18/30 kV 3x185+3x95/3.

Standards

NTSCGEWÖU-TR Standards and Test References

NTSCGEWÖU-TR / NTSCGEWOEU-TR 3.6/6–18/30 kV Tear-Resistant Open-Pit Shovel & Dragline Trailing Cable standards and test references
Standard or specificationApplication
DIN VDE 0250-813 (reference)Construction and high-voltage AC withstand test reference (11 kV to 43 kV) for MV trailing cables.
IEC 60228Class 5 finely stranded tinned copper phase and split protective-earth conductors.
DIN VDE 0207-20 / 0207-213GI3 EPR MV dielectric and tear-improved 5GM5 inner/outer heavy rubber compounds.
DIN EN / IEC 60332-1-2Flame retardance verification (sheath oxygen index LOI above 29).
DIN EN / IEC 60811-404Oil resistance test for elastomer outer sheaths.
DIN VDE 0298-3 / 0298-4Minimum trailing bend radius and ambient/drum current derating tables.

Certifications and document support

TEBAOFLEX ISO quality assurance and routine factory test reports

DIN Media — DIN VDE 0250-813 / 0298-3 / 0298-4 standards reference

IEC Webstore — IEC 60228 conductor, IEC 60332 flame and IEC 60811 oil test references

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.